• Title/Summary/Keyword: 비침습식 센서

Search Result 10, Processing Time 0.02 seconds

Implementation of a Non-Invasive Sensor System for Differentiating Human Motions on a Bed (침대에서 동작 식별을 위한 비침습식 센서 시스템의 구현)

  • Cho, Seung Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.39-48
    • /
    • 2014
  • In this paper, we propose an efficient dynamic workload balancing strategy which improves the performance of high-performance computing system. The key idea of this dynamic workload balancing strategy is to minimize execution time of each job and to maximize the system throughput by effectively using system resource such as CPU, memory. Also, this strategy dynamically allocates job by considering demanded memory size of executing job and workload status of each node. If an overload node occurs due to allocated job, the proposed scheme migrates job, executing in overload nodes, to another free nodes and reduces the waiting time and execution time of job by balancing workload of each node. Through simulation, we show that the proposed dynamic workload balancing strategy based on CPU, memory improves the performance of high-performance computing system compared to previous strategies.

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

Research on a Non-invasive Blood Glucose level Estimation Algorithm based on Near- infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 수치 추정 알고리즘 연구)

  • Young-Man Kang;Soon-Hee Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1353-1362
    • /
    • 2023
  • Various methods are being attempted to resolve the inconvenience of blood glucose meters used to check blood sugar levels. In this paper, we attempted to estimate blood sugar levels non-invasively using machine learning technology from spectral data acquired using a near-infrared sensor. The non-invasive blood glucose meter used in the study has a total of six near-infrared ray emitters, including visible rays, and a light receiver that receives them. It is a device created to collect spectral data on specific parts of the human body, such as the fingers. To verify whether there was a significant difference depending on blood sugar level, we attempted to estimate blood sugar level through machine learning algorithms. As a result of applying five machine learning algorithm techniques to the collected data and adjusting various hyper parameters, it was confirmed that the support vector regression algorithm showed the best performance.

Ring type non-invasive glucose sensor (민감도가 향상된 링 형태의 비 침습식 혈당 센서)

  • Lee, Ki-Hyuck;Lee, Kook-Joo;Lee, Dong-Ho;Kim, Moon-Il;Park, Gil-Hong
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.293-296
    • /
    • 2007
  • A novel sensitive and non-invasive ring-type glucose probe was designed and measured. The magnitude and phase of return loss change with different concentration of the glucose solution inside the loop structure. Ring type probe is more advantageous than open ended probe to measure electrical characteristics under the skin. The maximum difference of return loss was 0.94 for the concentration difference of 0% and 20% at 285MHz and more sensitive in low frequency.

  • PDF

Ring-Shaped Inductive Sensor Design and Application to Pressure Sensing (환형 인덕티브 센서의 설계 및 압력센서로의 적용)

  • Noh, Myounggyu;Kim, Sunyoung;Baek, Seongki;Park, Young-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.995-999
    • /
    • 2015
  • Inductive sensors are versatile and economical devices that are widely used to measure a wide variety of physical variables, such as displacement, force, and pressure. In this paper, we propose a simple inductive sensor consisting of a thin partial ring and a coil set. The self-inductance of the sensor was estimated using magnetic circuit analysis and validated through finite element analysis (FEA). The natural frequency of the ring was estimated using Castigliano's theorem and the method of equivalent mass. The estimation was validated through experiments and FEA. A prototype sensor with a signal processing circuit is built and applied to noninvasively sense the pressure inside a flexible tube. The obtained sensor outputs show quadratic behavior with respect to the pressure. When fitted to a quadratic equation, the least-square measurement error was less than 2%. The results confirm the feasibility of pressure sensing using the proposed inductive sensor.

Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor (FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포)

  • Shin, Ki-Young;Lee, Sang-Sik;Joo, Su-Bin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • Since many blood pressure pulse analyzer made to measurement of a pulse wave in quantitative way has been started, some sorts of pressure sensors are being developed. The result could differ and this cause either type of sensor or module shape, when pulse wave is measured. In this paper, calculate and compare the pressure sensor's stress distribution according to thickness of PDMS coating and existence of guide through Finite Element Method. As a result, the center of pressure sensor's stress increase as much as 24% as it is reduced as much as 0.3 mm that the PDMS coating thichness of pulse diagnostic sensor module, on the other hand the surrouding censor of center sensor's stress is reduced as much as 4.9%, and transmissive proportion of stress is small as little as 2.7%, When coating has guide.

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

Development of a Photoplethysmographic method using a CMOS image sensor for Smartphone (스마트폰의 CMOS 영상센서를 이용한 광용적맥파 측정방법 개발)

  • Kim, Ho Chul;Jung, Wonsik;Lee, Kwonhee;Nam, Ki Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4021-4030
    • /
    • 2015
  • Pulse wave is the physiological responses through the autonomic nervous system such as ECG. It is relatively convenient because it can measure the signal just by applying a sensor on a finger. So, it can be usefully employed in the field of U-Healthcare. The objects of this study are acquiring the PPG (Photoplethysmography) one of the way of measuring the pulse waves in non-invasive way using the CMOS image sensor on a smartphone camera, developing the portable system judging stressful or not, and confirming the applicability in the field of u-Healthcare. PPG was acquired by using image data from smartphone camera without separate sensors and analyzed. Also, with that image signal data, HRV (Heart Rate Variability) and stress index were offered users by just using smartphone without separate host equipment. In addition, the reliability and accuracy of acquired data were improved by developing additional hardware device. From these experiments, we can confirm that measuring heart rate through the PPG, and the stress index for analysis the stress degree using the image of a smartphone camera are possible. In this study, we used a smartphone camera, not commercialized product or standardized sensor, so it has low resolution than those of using commercialized external sensor. However, despite this disadvantage, it can be usefully employed as the u-Healthcare device because it can obtain the promising data by developing additional external device for improvement reliability of result and optimization algorithm.

Classifying Finger Flexing Motions with Surface EMG Using Entropy and The Maximum Likelihood Method (엔트로피 및 최대우도추정법을 이용한 표면 근전도 기반 손가락 동작 인식)

  • You, Kyung-Jin;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.38-43
    • /
    • 2009
  • We provide a method to infer finger flexing motions using a 4-channel surface electromyogram (sEMG). Surface EMGs are harmless to the human body and easily acquired. However, they do not reflect the activity of specific nerves or muscles, unlike invasive EMGs. On the other hand, the non-invasive type is difficult to use for discriminating various motions while using only a small number of electrodes. Surface EMG data in this study were obtained from four electrodes placed around the forearm. The motions were the flexion of the thumb, index, middle, ring, and little linger. One subject was trained with these motions and another left was untrained. The maximum likelihood estimation was used to infer the finger motion. Experimental results have showed that this method could be useful for recognizing finger motions. The average accuracy was as high as 95%.

A Study on Domestic Applicability for the Korean Cosmic-Ray Soil Moisture Observing System (한국형 코즈믹 레이 토양수분 관측 시스템을 위한 국내 적용성 연구)

  • Jaehwan Jeong;Seongkeun Cho;Seulchan Lee;Kiyoung Kim;Yongjun Lee;Chung Dae Lee;Sinjae Lee;Minha Choi
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.233-246
    • /
    • 2023
  • In terms of understanding the water cycle and efficient water resource management, the importance of soil moisture has been highlighted. However, in Korea, the lack of qualified in-situ soil moisture data results in very limited utility. Even if satellite-based data are applied, the absence of ground reference data makes objective evaluation and correction difficult. The cosmic-ray neutron probe (CRNP) can play a key role in producing data for satellite data calibration. The installation of CRNP is non-invasive, minimizing damage to the soil and vegetation environment, and has the advantage of having a spatial representative for the intermediate scale. These characteristics are advantageous to establish an observation network in Korea which has lots of mountainous areas with dense vegetation. Therefore, this study was conducted to evaluate the applicability of the CRNP soil moisture observatory in Korea as part of the establishment of a Korean cOsmic-ray Soil Moisture Observing System (KOSMOS). The CRNP observation station was installed with the Gunup-ri observation station, considering the ease of securing power and installation sites and the efficient use of other hydro-meteorological factors. In order to evaluate the CRNP soil moisture data, 12 additional in-situ soil moisture sensors were installed, and spatial representativeness was evaluated through a temporal stability analysis. The neutrons generated by CRNP were found to be about 1,087 counts per hour on average, which was lower than that of the Solmacheon observation station, indicating that the Hongcheon observation station has a more humid environment. Soil moisture was estimated through neutron correction and early-stage calibration of the observed neutron data. The CRNP soil moisture data showed a high correlation with r=0.82 and high accuracy with root mean square error=0.02 m3/m3 in validation with in-situ data, even in a short calibration period. It is expected that higher quality soil moisture data production with greater accuracy will be possible after recalibration with the accumulation of annual data reflecting seasonal patterns. These results, together with previous studies that verified the excellence of CRNP soil moisture data, suggest that high-quality soil moisture data can be produced when constructing KOSMOS.