• Title/Summary/Keyword: 비접촉 검사

Search Result 175, Processing Time 0.033 seconds

Variation of Nanoindentation Curve due to Wear of Indenter Apex and Its Correction Method (압입자 첨단마모에 따른 나노압입곡선의 변화 및 이의 보정기법)

  • Lee, Yun-Hee;Kim, Yong-Il;Park, Jong Seo;Kim, Kwang Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.129-137
    • /
    • 2013
  • A force calibration of a nanoindenter and a 3D morphology observation of indenters were carried out in this study. A microbalance calibrated with standard weights was used for measuring the loads generated by a nanoindenter. The indentation load could be calibrated from the ratio of measured and generated loads and the first contact load also could be detected from the microbalance data. By analyzing atomic force microscopy images of two indenters, curvature radii of apexes were determined by $19.71{\pm}3.03$ and $1043.94{\pm}50.91$ nm, respectively, for the nearly new indenter A and the severly worn indenter B. Corresponding bluntness depths were estimated by 1.22 and 64.56 nm for the both indenters by overlapping their profiles on the perfect pyramidal shape. In addition, nanoindentation curves obtained from a fused silica reference material with the both indenters showed a depth difference corresponding to the bluntness depth difference along the indentation depth axis. By shifting amounts of the bluntness depths along the horizontal axis, whole nanoindentation curves overlapped on themselves and resulted in nanohardness values consistent within 1.11 % without considering the complex indenter area function of each indenter.

Evaluation of the Clinical Usefulness of the Xeniss Rapid TB kit for the Diagnosis of Tuberculosis (결핵진단에서 Xeniss Rapid TB kit의 임상적 유용성)

  • Park, Seung-Kyu;Lee, Woo-Chul;Hwang, Soo-Hee;Kwon, Eun-Si;Lee, Hung-Soon;Lee, Duk-Hyoung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.389-400
    • /
    • 2002
  • Background : The rapid diagnostic tests for tuberculosis are needed to facilitate early treatment of tuberculosis and prevention of Mycobacterium tuberculosis transmission. The Xeniss Rapid TB kit is a rapid, card-based immunochromatographic test for the detection of antibodies directed against M. tuberculosis antigens including antigen 5(38-kDa antigen). The objective of this study was to evaluate the performance of the Xeniss Rapid TB kit for the diagnosis of active tuberculosis with serums from patients, asymptomatic healthy and close contact controls. Methods : 188 patients with active tuberculosis were tested; 177 with pulmonary tuberculosis(18 with combined pleurisy), and 11 with extrapulmonary tuberculosis. The control groups were composed of 82 close contacts and 57 healthy adults. Study subject were drawn from one national tuberculosis hospital for patients and close contacts, and another private hospital for healthy adults in Masan city, Korea. The Xeniss Rapid TB kit(Xeniss Life Science Co., Ltd., Seoul, Korea) was evaluated by using serum samples according to the instructions of the manufacturer by an investigator masked to the clinical and microbiological status of the study subjects. Results : The diagnostic sensitivity of the Xeniss Rapid TB kit was 73.9% in patients and specificities were 73.2% and 93.0% in close contact and healthy adults respectively. The positive predictive value in patients was 84.2% and the negative predictive value in controls was 85.8%. Conclusion : This study shows that the Xeniss Rapid TB test is a simple and fast method to diagnose active TB. The results of the sensitivity and specificites suggest that serodiagnosis using this point of care testing(POCT) device would be valuable and advantageous for screening tuberculosis in the clinical field.

Desensitizing Effects of a Nd:YAG Laser Irradiation on Hypersensitive Dentine (지각과민치아에 대한 Nd:YAG 레이저 조사의 효과)

  • Jung, Sung-Yong;Kim, Kyoung-Hee;Ko, Myong-Yun;Ahn, Yong-Woo;Park, Jun-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.465-473
    • /
    • 2005
  • The purpose of this study was to evaluate the desensitizing effects of a Nd:YAG laser (Sunlase, SUNRISE Technologies, Inc., USA) irradiation on cervically exposed hypersensitive dentine. 45 patients was irradiated with pulsed Nd:YAG laser (1.5 W, 20 Hz, 75 mJ/pulse, 4 minutes) as the experimental group, 27 patients was mock irradiated as the control group. The degree of sensitivity to the thermal and tactile stimuli were determined qualitatively with an evaporative stimulus defined as two times air blast at a distance of 3 mm from each site to be tested and with a mechanical stimulus as a slightly scratching the cervical site with a dental explorer. A qualitative registration of the degree of discomfort was determined according to a numerical pain scale(NPS) in an 11-point scale in which 0= "no pain" and 10="most excruciating pain imaginable". Recordings were assessed before treatment, immediately after, 1 and 2 weeks after treatment. Pain tolerance threshold and pulp vitality were evaluated with electric pulp tester before and immediately after treatment. 1. Desensitizing of hypersensitive dentine with Nd:YAG laser irradiation was more effective than that with mock irradiation. 2. The placebo effect of mock irradiation was recognized for severe sensitive teeth($NPS\;{\geqq}\;6$), but not for moderate sensitive teeth(NPS < 6). 3. Laser irradiation did not affect the pain tolerance threshold and pulp vitality of the hypersensitive teeth. 4. Desensitizing effect of laser irradiation for the hypersensitive teeth had been continuing at least 2 weeks. It was concluded that desensitizing of hypersensitive dentine with a Nd:YAG laser is effective and the maintenance of the positive result was more prolonged than the placebo effect.

A Study on Self-Expression Improvement of Children through Orff Activities (유아의 자기표현능력 증진을 위한 오르프 음악활동의 적용)

  • Kwon, Se mi
    • Journal of Music and Human Behavior
    • /
    • v.6 no.1
    • /
    • pp.55-80
    • /
    • 2009
  • The objective of this study was to improve the self-expression of children through Orff activities. In this study, three (3) children from D day care center in Seoul who demonstrated withdrawn behaviors were chosen as research subjects, based on a self-expression test score of 50 points. The activities were conducted for 6 weeks, totaling fourteen (14) sessions, with each session being scheduled for forty (40) minutes. Across 14 sessions, the researcher conducted, analyzed and compared the self-expression scale of subjects, measured during the third and the last session. The researcher then qualitatively analyzed verbal and non-verbal self-expression behaviors of subjects by video recording the session. The analysis results shown by the study are as follows. First, the results of a quantitative analysis of the self-expression scale showed significant changes in self expression. Furthermore, the results of a qualitative analysis of verbal self-expression showed positive changes in self-perception and an increase in feelings of independence and activity than that of initial sessions.

  • PDF

A Study on Smart Factory System Design for Screw Machining Management (나사 가공 관리를 위한 스마트팩토리 시스템 설계에 관한 연구)

  • Lee, Eun-Kyu;Kim, Dong-Wan;Lee, Sang-Wan;Kim, Jae-joong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.329-331
    • /
    • 2018
  • In this paper, we propose a monitoring system that starts with the supply of raw materials for threading, is processed into a lathe machine, and checks for defects of the product are automatically performed by the robot with Smart Factory technology through assembly and disassembly. Completion check according to the production instruction quantity and production instruction is made by checking the production status according to whether or not the raw material is worn by the displacement sensor, and checking the pitch and the contour of the processed female and male to determine OK and NG. The robotic system acts as a relay for loading and unloading of raw materials, pallet transfer, and overall process, and it acts as an intermediary for organically driving. The location information of the threaded products is collected by using the non-contact wireless tag and the energy saving system Production efficiency and utilization rate were checked. The environmental sensor collects the air-conditioning environment data (temperature, humidity), measures the temperature and humidity accurately, and checks the quality of product processing. It monitors and monitors the driving hazard level environment (overheating, humidity) of the product. Controls for CNC and robot module PLC as a heterogeneous system.

  • PDF

Development of Chicken Carcass Segmentation Algorithm using Image Processing System (영상처리 시스템을 이용한 닭 도체 부위 분할 알고리즘 개발)

  • Cho, Sung-Ho;Lee, Hyo-Jai;Hwang, Jung-Ho;Choi, Sun;Lee, Hoyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.446-452
    • /
    • 2021
  • As a higher standard for food consumption is required, the consumption of chicken meat that can satisfy the subdivided food preferences is increasing. In March 2003, the quality criteria for chicken carcasses notified by the Livestock Quality Assessment Service suggested quality grades according to fecal contamination and the size and weight of blood and bruises. On the other hand, it is too difficult for human inspection to qualify mass products, which is key to maintaining consistency for grading thousands of chicken carcasses. This paper proposed the computer vision algorithm as a non-destructive inspection, which can identify chicken carcass parts according to the detailed standards. To inspect the chicken carcasses conveyed at high speed, the image calibration was involved in providing robustness to the side effect of external lighting interference. The separation between chicken and background was achieved by a series of image processing, such as binarization based on Expectation Maximization, Erosion, and Labeling. In terms of shape analysis of chicken carcasses, the features are presented to reveal geometric information. After applying the algorithm to 78 chicken carcass samples, the algorithm was effective in segmenting chicken carcass against a background and analyzing its geometric features.

Comparison of Forcep-biopsy and Cryo-biopsy by a Flexible Bronchoscopy (굴곡성 기관지경을 통한 겸자 생검술과 냉동 생검술의 비교)

  • Kim, Jae Hyun;Choi, Jung Min;Song, Sung Eun;Lee, Eun Mi;Lee, Song Ju;Oak, Chul Ho;Jang, Tae Won;Jung, Man Hong;Jang, Hee Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.2
    • /
    • pp.110-115
    • /
    • 2009
  • Background: A forceps-biopsy is performed to acquire tissue from patients with an endobronchial carcinoma using a flexible bronchoscope. Recently, a cryo-biopsy has also been used to acquire tissue samples. Cryo-biopsy is the diagnostic application of extreme cold for the local destruction of abnormal living tissue. This technique is safe, with no radiation danger, no risk of electrical accidents, and a little risk of bleeding. This study compared a forceps-biopsy with a cryo-biopsy using a flexible bronchoscope, and examined the chemosensitivity and level of VEGF (vascular endothelial growth factor) in the specimens obtained from the cryo-biopsy. Methods: We present a prospective study of 30 consecutive patients who underwent a forceps-biopsy between January 2007 and October 2007 with a mean age of 62.1 years and a male:female ratio of 5 : 1. A flexible bronchoscope was inserted to the area of the abnormal lesions, and a cryo-probe was then applied through the working channel of the flexible bronchoscope. A temperature of approximately -h80 was delivered to the tumor site for 8 seconds. The cryo-biopsy was performed after destroying the tumor mass. Results: The mean size of the tissue from the forceps-biopsy and cryo-biopsy were 2.0${\pm}$1.2 mm and 6.0${\pm}$3.0 mm. A chemosensitivity test was performed on 5 specimens obtained using cryo-biopsy and the level of VEGF was examined in 2 specimens obtained from a cryo-biopsy. There were no side effects in either group. Conclusion: Cryo-biopsy using a flexible bronchoscope is a safe and effective technique for acquiring tissue samples.

The Food Safety of Superfine Powder (Phellinus linteus) Processed by Nanomill in C57BL/6 Mice (C57BL/6 마우스에서 나노밀 가공된 초미세분말(상황버섯)의 식이 안전성 연구)

  • Kim, Dong-Heui;Teng, Yung-Chien;Yoon, Yang-Sook;Qi, Xu-Feng;Jeong, Hyun-Seok;Joo, Kyung-Bok;Lee, Kyu-Jae
    • Applied Microscopy
    • /
    • v.39 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • A officinal mushroom, Phellinus linteus (PL) has been known to exhibit potent biological activities including antioxidative and anticancer effect. PL is consumed as a type of powder or extract for the purpose of health promotion and disease treatment. Recently superfine PL products was commercialized according to the development of pulverizing technology such as nanomill, so the evaluation of food safety is suggested. This study was conducted to evaluate the food safety of superfine PL (SPL) through hematological, biochemical and histological examination in mice as compared with fine PL (FPL). In the particle size distribution in volume after nanomill processing, the mean diameter of SPL and FPL particles was 11.78 ${\mu}m$ and 216.1 ${\mu}m$, and d (0.5), the particle diameter measured at 50% of distribution was 5.5 ${\mu}m$ and 147.9 ${\mu}m$, respectively. As the result of body weight, food intake and the weight of organs, SPL group didn't show any statistical difference compared with FPL group and normal group (N). Hematological and biochemical values were also involved in the normal range, although ALT (N vs. FPL, P<0.001) and BUN (N vs. FPL, P<0.01; N vs. SPL, P<0.01) showed significance compared with N group but there are no significance between FPL and SPL group. In the result of histological examination with liver, kidney, spleen, and small and large intestine, abnormal findings such as inflammatory reaction and histological changes were not observed. Our results suggest that the oral intake of SPL diet is not harmful to the animal in the hematological, biochemical and histological aspects although particle size was reduced to the level of superfine. However, further study will be necessary to confirm the histological safety in relation to the gastrointestinal contact of superfine particles in the case of large amount and long-term intake.

Clinical Aspect of Bovine Abortion in Korea II. Effects of Season, Parity and Gestation Stage on Bovine Abortion (국내 소 유산에 관한 임상학적 고찰 II. 계절, 산차별 및 임신단계에 따른 영향)

  • 이병천;김대용;유한상;김성기;김영찬;구자홍;박봉균;윤희정;윤병일
    • Journal of Embryo Transfer
    • /
    • v.17 no.2
    • /
    • pp.163-168
    • /
    • 2002
  • The objective of this study was to investigate the clinical aspects on bovine abortion and stillbirth in Korea. Three hundred thirty eight bovine fetuses were collected from farms and submitted to the College of Veterinary Medicine, Seoul National University. Submitted fetuses were evaluated for season, parity and gestation stage on abortion during a 3 years period (June, 1999 to April, 2002). Out of four seasons, incidence of bovine abortion was significantly higher in summer than other seasons (P<0.05) due to high temperature and humidity. After surveying of incidence of abortion according to parity, it was concentrated in low parity (1, 2 and 3 parity). However, this result was not caused by parity but because most of surveyed cow was low parity. For surveying the distribution of abortion incidence according to days of gestation, we divided the days of gestation into 3 stages including with early (0∼150 days), middle (151∼250 days) and late (251days∼term). Out of 319 aborted fetuses, incidences of abortion were significantly higher in the middle and late stage than early stage (P<0.05). A high rate (75%) of stock farms did not vaccinate animals, therefore most of cows in Korea were found to have a high risk of becoming infected upon exposure to pathogens. Many of abortions occurred in stock farms where animals of other species were being bred. More studies will be needed to investigate possible linkages between bovine abortion and the breeding of other animal species.

Composting Methods for Pig Sludge and the Stabilized Investigation of Crop Cultivation (돈분의 자원화 퇴비 제조 방법 및 작물 재배 안전성 검정)

  • Oh, Tae-Seok;Kim, Chang-Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.29 no.1
    • /
    • pp.51-62
    • /
    • 2009
  • This study was carried out development a new composting system to lower copper and zinc concentration in plg sludge compost and conduct an inquiry into the possibility of crop cultivation. The concentrations of nitrogen, phosphorus and pH averaged 4.4%, 6.3% and 7.57, respectively, which were higher concentrations than in commercial organic fertilizers, and the concentrations of copper and zinc averaged 805 and 1,704 mg/kg, respectively, which were beyond the heavy metal concentration limit in byproduct compost. Hydrated citric acid I lowered the concentrations of copper and zinc by 58% and 97%, respectively and hydrated oxalic acid II lowered the concentrations of copper and zinc by 48% and 56%, respectively in pig sludge compost. Lower concentrations of copper and zinc in pig sludge resulted from the enhanced hydrated-citric acid concentration in organic acid solution mixed with distilled water. The concentrations of copper and zinc were 330, and 41 mg/kg in the pig sludge treated with 100% hydrated citric acid. Agitation composting system stabilized the compost earlier than the stationary composting system, in which the stabilization condition was confirmed by higher temperature by $4^{\circ}C$ at highest temperature and 7 days earlier cooling down after highest temperature. The levels of germination index (G.I) 80 were obtained 15 and 20 days after composting in agitation and stationary composting system, respectively. The concentrations of copper and zinc were 2.4 and 4.26 mg/kg respectively in soils amended with pig sludge compost after removing process of heavy metals by citric acid, but 8.0 and 22.37 mg/kg, respectively in soils amended with Pig Sludge. The concentrations of heavy metals was highest in com cultivated in soils amended with pig sludge. The copper and zinc concentrations In corn leaves were 75.2 and 50.56 mg/kg respectively, which were 4 and 2 fold higher than the com cultivated in soils amended with pig sludge compost after heavy metal removing process by hydrated citric acid.