• Title/Summary/Keyword: 비용절감액

Search Result 78, Processing Time 0.032 seconds

Economic Feasibility Assessment for the Interior Materials Selective Dismantling System Promotion in Buildings (건축물 분별해체 제도 활성화를 위한 경제적 효용성 평가)

  • Ji-Sun Park;Kyung-Pil Jang;Tae-Hyeob Song
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.251-259
    • /
    • 2023
  • In this study, as a foundational research aimed at promoting the efficient recycling and environmentally friendly disposal of construction waste through the activation of a selective dismantling system, our primary objective was to analyze the economic feasibility of implementing selective dismantling. To achieve this, we conducted an assessment on a 5-story residential building with a construction area of 2,400 m2 as a case study. When considering the additional cost of dismantling construction ① the reduction in waste disposal costs due to decreased mixed waste, ② and the potential revenue from recycling through the separation and sorting of waste materials, and ③ we were able to comprehensively confirm that there is an expected cost-saving effect totaling 34,727,000 KRW when compared to conventional demolition methods.

Assessing the willingness to pay for avoiding water pipeline accidents by repairing pipelines (갱생사업의 관로사고 피해저감에 대한 지불의사액 추정)

  • Choi, Hyo Yeon;Ryu, Mun Hyun;Choi, Han Joo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.126-126
    • /
    • 2017
  • 수도권 광역상수도는 관로 매설 이후 30년 이상 경과하여 수도관로 사고 발생빈도가 증가하고 있다. 이에 노후관로를 갱생하여 사고예방과 용수공급 안정성 강화를 도모할 필요가 있으며, 이러한 사업의 수행 여부에 대한 판단을 위해서는 사업 시행으로 발생하는 경제적 편익에 대한 정량적 정보가 필요하다. 노후관로 갱생사업의 경제적 편익은 크게 관로사고 피해저감 편익과 복구비용 절감편익으로 구분되는데 후자는 공학적 접근을 통해 비교적 쉽게 평가할 수 있는 반면에, 전자는 평가가 어렵다. 이에 본 논문에서는 조건부 가치측정법이라는 경제학적 기법을 적용하여 관로사고 피해저감 편익을 추정하고자 한다. 수도권 광역상수도 갱생사업의 수혜지역 주민 600 가구를 무작위로 추출하여 수도권 광역상수도 갱생사업이 시행되지 않을 경우 관로사고가 발생할 수 있음을 설명한 후, 관로사고를 막기 위한 지불의사액을 조사하였다. 분석결과 관로사고 피해 회피를 위한 가구평균 지불의사액은 톤당 약 41.7원이었다. 이 정보는 노후관로 갱생사업에 대한 의사 결정시 활용할 수 있다.

  • PDF

A Feasibility Study on Optimization System of Coagulant Dosing for Total Phosphorous Treatment (총인 처리를 위한 응집제 주입량 최적제어 시스템의 적용성 연구)

  • Seo, Jeong-Mi;Cho, Young-Beom;Choi, Ye-Mook;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, we developed an M-COS (molit coagulant-dosing optimization system), which enables to apply the optimum coagulant dose determined in real time, in order to satisfy the total phosphorus (TP) regulation (0.5 mg/L), and then tested its field applicability. Field tests were conducted at three different periods in 2014 in a pilot plant where the M-COS was installed. Coagulant reduction rate by the M-COS was 10.4%, 15.3%, and 9.0% for each period (average 11.6%), when comparing with a control where coagulants were applied at a constant rate. Total cost for the M-COS or control was estimated by summing up the coagulant cost and sludge treatment cost, and then the resulting cost increase was predicted. Cost reduction rate by the M-COS was 13.8%, 20.0%, and 11.4% for each period (average 15.0%). This study indicates that the M-COS can be an alternative to a conventional system for TP treatment, with a better cost efficiency.

The Cost Effectiveness Analysis of Multi-Water Resources (다중수원의 비용효과 분석 : 스마트워터그리드를 중심으로)

  • Ryu, Mun-Hyun;Choi, Hanju;Suh, Jinsuhk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.119-119
    • /
    • 2015
  • 스마트워터그리드의 목적은 기존 용수부족 문제의 근본적인 해결을 위해 새로운 취수원을 개발하고, 지역 내의 수자원을 효율적으로 활용하는 방안을 강구하는 시스템을 구축하는데 있다. 따라서 운영비용을 최소화하면서 수요처에 적정한 수량과 수질의 용수를 공급할 수 있도록 해야한다. 스마트워터그리드 구축 시 설비 비용에 대한 부담으로 보급 확산에 어려움을 겪을 가능성이 높으므로, 비용 효과적(Cost-effective)인 측면에서 스마트워터그리드의 경제성을 검토할 필요성이 있다. 본 연구에서는 자료의 한계로 인해 기존의 다중수원에 대한 경제성분석 사례를 인용하여 상수도 생산원가 절감액, 댐 건설과 관련된 비용의 감소, 물 오염 감소 등으로 편익을 간접적으로 계산하고, 기술적으로 물량이 충분하다는 가정하에 다중수원들간의 비용효과분석 수행하였다. 분석결과, 현재 공급하고 있는 상수도 시스템이 다른 다중취수원에 비해 비용효과적 우위에 있는 것으로 나타났다. 지하수, 해수담수화 등 새로운 수원을 찾는 노력이 필요하며 지하수는 가장 쉽게 활용할 수 있는 대체 수원이지만, 관정개발에 많은 비용이 들고 대량으로 수원을 공급하기 어렵다는 단점이 있다. 해수담수화는 대체수자원으로서 중요성이 더욱 강조될 것으로 보이지만, 시설의 설치 및 운영에 드는 높은 비용과 함께 육지에서 물을 대량으로 연안에서 멀리 떨어져 있거나 고도가 높은 지역은 해수담수화 기술의 적용이 어려울 것으로 여겨진다.

  • PDF

Economic Evaluation of ATES Heat Pump System (ATES 열펌프 시스템의 경제성 평가)

  • Kim, Namtae;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.199-199
    • /
    • 2011
  • ATES(Aquifer Thermal Energy Storage) 열펌프 시스템은 기존의 다양한 열원 적용 시스템 대비 효율이 우수한 것으로 알려져 유럽과 미국에서 건물 냉난방 시스템으로 적용되고 있다. 특히, ATES 시스템은 기존의 냉난방 시스템 대비 경제성이 우수한 것으로 알려져 있으나 국내에서는 이에 대한 연구 결과는 전무한 실정이다. 본 연구에서는 ATES 열펌프 시스템의 실증 성능 결과를 분석하였으며, LNG 보일러와 에어컨을 사용하는 기존의 냉난방 시스템을 비교시스템으로 ATES 열펌프 시스템의 경제성 평가를 수행하였다. ATES 시스템의 연간 실증 성능 실험결과 ATES 시스템은 외기온도와 무관하게 연중 안정적인 성능을 나타내었다. 경제성 평가시에 생애주기법(Life Cycle Cost)을 적용하여 ATES 열펌프 시스템의 설치 및 운전에 필요한 총 소요비용을 산정하고, 이 결과를 바탕으로 투자회수기간법을 통해 ATES 시스템의 투자회수 기간을 산정하였다. 생애주기법 적용 시에 현재가치법을 사용하였으며, 현재가치법은 수명주기에 발생하는 모든 투자비용과 절감액을 일정한 시점을 기준으로 등가환산하는 방법을 의미한다. 현재가치법에 사용되는 현재가치는 초기비용과 현재가치계수의 곱으로 나타나는데, 여기에서 현재가치계수는 임의의 이자율로 일정기간 동안 정기적인 할부금액이 적립될 때의 현재금액을 구하기 위해 사용하는 계수를 의미한다. 전기와 LNG는 각각 2009년 7월의 (주)한국전력공사와 (주)한국가스공사의 고시요금을 적용하였다. 본 시스템은 실증 설비용량인 20RT를 대상 건물로 가정하였고, 초기투자비는 크게 공사비와 냉난방 설비 구입비로 구성되어 있으며, 기본적인 물가지표는 (사)한국물가정보(KPI)의 고시 데이터를 참조하였다. 각 시스템의 초기투자비는 ATES 시스템이 비교대상 기존 냉난방 시스템 대비 5.7배 높게 나타났다. 일일 8시간 사용기준으로 계절별 전력요금을 고려한 연간운전 비용은 ATES 시스템이 기존 시스템 대비 냉난방 시에 각각 77%와 16%를 나타내어 운전비용이 연간 절감되었고, 난방 운전 시 절감 비율이 냉방시보다 크게 나타났다. 두 시스템에 대한 생애주기비용을 산정하기 위하여 에어컨과 보일러의 기존시스템과 ATES 시스템의 가용연수를 모두 20년으로 설정하였고, 유지보수 비용은 초기투자비용의 2%로 설정하고, 할인율은 은행 예금이자를 기준으로 5%로 설정하였다. 전기와 LNG의 요금 상승률은 (사)한국물가정보를 바탕으로 각각 2%와 8%로 가정하였다. 이러한 조건에서 생애주기법을 이용한 경제성평가는 ATES 시스템의 경우 생애운전비용이 초기투자비용보다 작게 나타났으며, 기존 냉난방 시스템은 생애운전비용이 초기투자비용에 비하여 높게 나타났다. 본 연구 대상 ATES 열펌프 시스템의 실증 성능 데이터와 기존 문헌으로부터 얻은 냉난방 시스템의 성능 결과를 이용하여 생애주기 비용을 적용한 결과 ATES 시스템의 기존 시스템 대비 투자회수 기간은 6.62년으로 나타났다. 특히, 본 연구에서는 ATES 시스템이 국내 최초로 적용됨에 따라 스크린 등의 부품을 다소 고가의 제품으로 시스템에 적용하였으므로 ATES 시스템의 신뢰성과 안정성이 확보되면 초기 투자비 감소가 가능할 것으로 예상되며, 기존 시스템 대비 투자회수 기간은 더욱 감소될 수 있을 것으로 예상된다.

  • PDF

A Study of Complex Distillation Arrangements Using Dividing Wall Columns for Improved Depropanizing, Debutanizing and Deisobutanizing Fractionation of NGL (천연가스액 중 프로판, 부탄, 이소-부탄의 개선된 분리회수를 위한 분리벽형 증류탑을 이용한 복합 증류배열에 관한 연구)

  • Nguyen, Van Duc Long;Jang, Sungkeun;Lee, Moonyong
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.245-249
    • /
    • 2013
  • The depropanizing, debutanizing and deisobutanizing fractionation steps of processing natural gas liquids were improved through studying complex distillation arrangements, including the double dividing wall column arrangement (DDWC), the sequence including a dividing wall column (DWC) and a bottom DWC (BDWC), and the sequence including a DWC and a BDWC with top vapor recompression heat pump. These arrangements offer benefits by decreasing reboiler and condenser power consumption. Reducing the number of columns and their diameters can potentially reduce construction costs. The result also showed that operating cost could be reduced most significantly through novel combinations of internal and external heat integration: bottom dividing wall columns employing a top vapor recompression heat pump.

Analysis of Social Benefit for the Selective Dismantling System in Buildings (건축물 분별해체 제도 도입으로 인한 사회적 편익 분석)

  • Woo-Jin Park;Kyong-Pil Jang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.222-228
    • /
    • 2024
  • This study aims to anal yze the social benefits of introducing a sel ective demol ition system for buil dings. Incremental revenue, incremental cost, and incremental profit for the entire nation were derived based on the calculated costs and revenues of selective demolition for a 2,400 m2 apartment complex. In conducting selective demolition on a 2,400 m2 building, the increase in demolition construction costs, the reduction in waste disposal costs due to the decrease in mixed waste, and the revenue obtained from recycling separated and sorted waste were comprehensively reviewed. It was calculated and analyzed that, compared to general demolition work, a total cost-saving effect of 34,727,000 KRW could be expected. Extrapolating this to the entire nation, based on the year 2020, which had the highest construction waste generation, it is estimated that the social benefits would amount to 746,782,886,000 KRW.

Convergence Study on FTO Film Etchant (FTO 필름 식각액에 관한 융합연구)

  • Han, Doo-Hee;Yang, Ui-Dong
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.43-48
    • /
    • 2018
  • An etchant capable of forming a circuit in an FTO film that can replace ITO, which depends on full imports, was prepared. The etching solution is composed of 1 to 30% by weight of fluoride, 1 to 20% by weight of acid, 0.5 to 5% by weight of surfactant, 5 to 20% by weight of solvent, 0.5 to 10% by weight of corrosion inhibitor and the balance of water. This etchant can be etched using a dry film, thereby reducing the cost, and is free from bubbles and residue of the etchant. The characteristics of the etchant were etched in a time of 2 minute with a 100 nm thick FTO, and the etchant temperature was maintained at $50^{\circ}C$. An undercut of -0.00364% was obtained when put into a 2 minute etching solution. No harmful substances such as Cd, Pb, Hg and Cr components were measured. The use of FTO in Korea where rare earths do not exist can achieve localization and import substitution effect.

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

Development and Economic Effect of Integrated Optimum Operation System using Wide Area Energy (광역에너지이용 통합 최적화 운전 시스템 개발 및 경제적 효과)

  • Lee, Hoon;Kim, Lae-Hyun;Chang, Won-Seok
    • Journal of Energy Engineering
    • /
    • v.18 no.4
    • /
    • pp.221-229
    • /
    • 2009
  • This study develops the optimized operation program which enables effective and economic operation between individual and connected branch offices by analyzing the current status and influential indicators of district heating companies' capital branch offices. Accordingly, the study examines the efficiency of optimized operation program. In doing so, this study has diagnosed and analyzed various factors, such as boilers, pumps, and relevant tags (temperature, pressure, fuel amount) through investigation of individual branch offices, and finally succeeded in developing wide-ranging data base by factor covering one-year time period. Additionally, after running the optimized operation program, different branch offices, optimum preference has turned out "incinerator receiving heat from KEPCO>CHP >PLBs>PLBw." Meantime, except the connected offices, there has been no big difference between actual and optimum operation program in branch offices. Meanwhile, the integrated optimum operation program has made it possible the most optimal result only via the connecting supply and demand heat without changing received Heat from KEPCO which is the same as total productive heat. The result has showed that the reduction percentage per day is 2.45~6.80%, and the reduction cost per day is 22,727~60,077 thousand won given the randomly selected sample days. In particular, winter time shows the highest demand with the largest reduction cost whereas summer time illustrates the lowest demand with the smallest reduction cost. Given this result, reduction cost per year compared to actual heat production cost for one year theoretically would be 84 hundred million won. Also, the economic effect showed that the reduction cost percentage per year is more than 2.74% on heat production cost per year for all capital branch offices.