• Title/Summary/Keyword: 비쌍극자 효과

Search Result 34, Processing Time 0.021 seconds

Behavior of Normalized Voltage Curves in the Resistivity Method (전기비저항 탐사에서 전위감쇠곡선의 거동특성)

  • Cho, In-Ky;Lee, Keun-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.364-369
    • /
    • 2010
  • Resistivity data should be edited before the inversion because resistivity data are contaminated by a lot of noise. Generally, outlier or data violating pants-leg effect in dipole-dipole array were used to be rejected in the apparent resistivity pseudo-section. For more precise data editing, normalized voltage curves are used. In this study, we analyzed the behavior of normalized voltage curves for pole-pole, pole-dipole and dipole-dipole arrays in the presence of threedimensional inhomogeneities, and finally re-examined the validity of normalized voltage curves in the editing process of resistivity data.

Interpretation of Finite HMD Source EM Data using Cagniard Impedance (Cagniard 임피던스를 이용한 수평 자기쌍극자 송신원 전자탐사 자료의 해석)

  • Kwon Hyoung-Seok;Song Yoonho;Seol Soon-Jee;Son Jeong-Sul;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.108-117
    • /
    • 2002
  • We have introduced a new approach to obtain the conductivity information of subsurface using Cagniard impedance over two-dimensional (2-D) model in the presence of horizontal magnetic dipole source with the frequency range of $1\;kHz\~1\;MHz$. Firstly, we designed the method to calculate the apparent resistivity from the ratio between horizontal electric and magnetic fields, Cagniard impedance, considering the source effects when the plane wave assumption is failed in finite source EM problem, and applied it to several numerical models such as homogeneous half-space or layered-earth model. It successfully provided subsurface information even though it is still rough, while the one with plane wave assumption is hard to give useful information. Next, through analyzing Cagniard impedance and apparent resistivity considering source effect over 2-D models containing conductive- or resistive-block, we showed that the possibility of obtaining conductivities of background media and anomaly using this approach. In addition, the apparent resistivity considering source effect and phase pseudosections constructed from Cagniard impedance over the isolated conductive- and resistive block model well demonstrated outlines of anomalies and conductivity distribution even though there were some distortions came from sidelobes caused by 2-D body.

$-{\rho}a$ by One Steel Casing Borehole near Resistivity Survey Line (비저항 측선 근처 철케이싱 시추공 한개에 의한 $-{\rho}a$)

  • Jung, Hyun-Key
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.83-86
    • /
    • 2006
  • From numerical modeling test $-{\rho}a$ by one steel casing borehole near resistivity survey line can be acquired. Negative apparent resistivities even in the flat area are surely subsurface information. Inversion technique for those need to be developed in the near future.

  • PDF

Analysis of Highschool Students' Misconception Textbooks Related to the Declination (편각과 관련된 고등학생들의 오개념 및 교과서 분석)

  • Lee, Gyu-Ho
    • Journal of the Korean earth science society
    • /
    • v.32 no.6
    • /
    • pp.687-703
    • /
    • 2011
  • The declination is an important concept because it is the underlying concept to understand the plate tectonics and also is used to decide one's location by using the compass and the map in real life. So this study surveys the description of declination being used in six of the seventh curriculum earth science II textbooks followed by the investigation of the possible of misconceptions that the highschool students might have. Utilizing an inventory of key concept, this study examines the actual misconceptions of highschool students, and investigates the relationship between misconceptions and textbooks. As a result, highschool students possess some misconceptions particularly with respect to the magnetic north pole which is caused by a lack of explanation about declination and by a wrong illustration. Therefore we suggest that detailed explanations of declination with non-dipole effect and precise illustrations be provided in the textbook for students th have a better understanding about declination.

Electrical resistivity and seismic reflection mapping for the southeastern part of the Yongdong basin (Cretaceous), Korea (영동분지(백악기) 남동부의 전기비저항 및 탄성파탐사자료 해석)

  • Kim, Ji-Su;Han, Su-Hyeong;Lee, Cheol-U;Kim, Bok-Cheol;Yang, U-Heon;Son, Ho-Ung;Son, Yeong-Gwan
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.77-90
    • /
    • 2000
  • Five electrical resistivity dipole-dipole and two seismic reflection surveys were performed in the southeastern margin of the Yongdong basin to delineate the shallow basin architecture. To investigate the intra-basin structure, twenty four resistivity sounding points and three dipole-dipole lines were selected especially in the vicinity of volcanic masses. The basin-fault boundaries are identified in electrical dipole-dipole resistivity section as high resistivity-contrast of approximately $1,500\;{\Omega}{\cdot}m$, characterized as a band of high standard-deviation. They are also effectively clarified in the seismic reflection data: amplitude and continuity contrasts in the common shot gather, first-arrival profiles, complex attribute plots. The intra-basin resistivity structures are constructed by interpolating vertical electrical sounding data and dipole-dipole profiles. The high-resistivity anomalies most likely originate from the northsouth-trending and northeast-dipping volcanic masses, which are to be further quantitatively investigated with geomagnetic and magnetotelluric surveys.

  • PDF

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Application of Depth Resolution and Sensitivity Distribution of Electrical Resistivity Tomography to Modeling Weathered Zones and Land Creeping (전기비저항 깊이분해능 및 감도분포: 풍화층 및 땅밀림 모델에 대한 적용)

  • Kim, Jeong-In;Kim, Ji-Soo;Ahn, Young-Don;Kim, Won-Ki
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.157-171
    • /
    • 2022
  • Electrical resistivity tomography (ERT) is a traditional and representative geophysical method for determining the resistivity distributions of surrounding soil and rock volumes. Depth resolution profiles and sensitivity distribution sections of the resistivities with respect to various electrode configurations are calculated and investigated using numerical model data. Shallow vertical resolution decreases in the order of Wenner, Schlumberger, and dipole-dipole arrays. A high investigable depth in homogeneous medium is calculated to be 0.11-0.19 times the active electrode spacing, but is counterbalanced by a low vertical resolution. For the application of ERT depth resolution profiles and sensitivity distributions, we provide subsurface structure models for two types of land-creping failure (planar and curved), subvertical fracture, and weathered layer over felsic and mafic igneous rocks. The dipole-dipole configuration appears to be most effective for mapping land-creeping failure planes (especially for curved planes), whereas the Wenner array gives the best resolution of soil horizons and shallow structures in the weathered zone.

A Bayesian Approach to Geophysical Inverse Problems (베이지안 방식에 의한 지구물리 역산 문제의 접근)

  • Oh Seokhoon;Chung Seung-Hwan;Kwon Byung-Doo;Lee Heuisoon;Jung Ho Jun;Lee Duk Kee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.262-271
    • /
    • 2002
  • This study presents a practical procedure for the Bayesian inversion of geophysical data. We have applied geostatistical techniques for the acquisition of prior model information, then the Markov Chain Monte Carlo (MCMC) method was adopted to infer the characteristics of the marginal distributions of model parameters. For the Bayesian inversion of dipole-dipole array resistivity data, we have used the indicator kriging and simulation techniques to generate cumulative density functions from Schlumberger array resistivity data and well logging data, and obtained prior information by cokriging and simulations from covariogram models. The indicator approach makes it possible to incorporate non-parametric information into the probabilistic density function. We have also adopted the MCMC approach, based on Gibbs sampling, to examine the characteristics of a posteriori probability density function and the marginal distribution of each parameter.

Analysis on Permittivity of Soil to Evaluate Pore Water Contamination

  • Oh Myoung-Hak;Kim Yong-Sung;Yoo Dong-Ju;Park Jun-Boum
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.249-252
    • /
    • 2005
  • 저주파수에서 유전상수 측정시 100kHz 이하의 주파수 영역에서는 전극분극효과가 발생하므로 100kHz이상의 주파수에서 유전상수가 평가되어야 한다. 유전상수는 쌍극자모멘트의 수에 비례하기 때문에 흙의 유전상수는 체적함수비에 따른 선형적인 증가경향을 나타내었다. 용액에 이온성분이 존재하는 경우에는 수화작용에 의한 물분자의 배향분극 발현의 감소로 인하여 유전상수가 감소한다. 흙과 중금속 혼합시료의 경우 함수비가 큰 시료에서는 용액의 유전특성이 발현되지만, 함수비가 작은 경우에는 공간전하분극의 영향으로 유전상수가 10-20%정도 증가하는 경향을 나타내었다. 현장에서의 정확한 오염도 평가를 위해서는 토양의 함수비에 대한 평가가 반드시 수행되어야 한다.

  • PDF