• Title/Summary/Keyword: 비선형 초음파

Search Result 138, Processing Time 0.03 seconds

An Experimental Study of the Synthetic Sinc Wave in Ultrasonic Imaging (초음파 의료 영상에서 합성 Sinc 음장 집속방법의 실험적 고찰)

  • 이광주;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.243-251
    • /
    • 2002
  • Synthetic zinc wave employs Pulsed plane wave as transmit beam with linear time delay curve. The received echoes in different transmit directions at different transmit times are superposed at imaging Points with Proper time delay compensation using synthetic focusing scheme. This scheme. which uses full aperture in transmit, obtains a high SNR image, and also features high lateral resolution by using two way dynamic focusing at all imaging depths. In this Paper, we consider the Problems in realization of synthetic zinc wave. Also. we have applied the scheme to obtain phantom and in-vivo images using a linear array of 5 MHz. In phantom test. experimental images show high resolution over a more extended imaging depth than conventional fixed Point transmit and receive dynamic focusing schemes In-vivo images show that the resolution could not overcome conventional focusing systems because of motion blurring and(or) aberration of tissue. but the frame rate tan be increased by a factor of more than 5 compared to conventional focusing schemes. with competitive resolution at all imaging depths .

Ultrasonic Nondestructive Evaluation of Creep-Induced Cavities (크리프 기공의 초음파 비파괴평가에 관한 연구)

  • Jang, Young-Su;Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.110-117
    • /
    • 1999
  • In order to ultrasonically evaluate creep cavities pure copper samples were subjected to creep test and their microstructures were examined. Ultrasonic velocities. frequency-dependent magnitude spectra and attenuations were measured on a series of copper samples obtained from the different stages of creep test. Velocities measured in three directions with respect to the loading axis decreased and their anisotropy increased as a function of the creep-induced porosity. The anisotropic behavior could be attributed to the progressive change of pore shape and preferred orientation as the creep advanced. The 2% porosity by volume decreased the longitudinal and shear wave velocities by 11% and 4%, respectively. Furthermore, both velocities decreased nonlinearly with the porosity. As the creep damage developed, the magnitude spectra lost high frequency components and their central frequencies shifted to lower values. The attenuation showed almost linear behavior in the frequency range used. Normalized velocity, central frequency shift and attenuation slope were selected as nondestructive evaluation parameters. These results were presented and showed good relations with the porosity content.

  • PDF

Merkel Cell Carcinoma of the Trunk: Two Case Reports and Imaging Review (몸통에 생긴 메르켈 세포암종: 2예 증례 보고 및 영상 소견 고찰)

  • Ha Yun Oh;Donghan Kim;Yun Sun Choi;EunKyung Kim;Tae Eun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1134-1139
    • /
    • 2023
  • Merkel cell carcinoma (MCC) is a rare malignant cutaneous tumor primarily located in the head and neck. We report the imaging features of pathologically confirmed MCC in the trunk. On US, MCC showed heterogeneous echogenicity with perpendicular hypoechoic linear bands that resembled "columns of smoke" in the skin and subcutaneous layers as well as prominent vascularity. On MRI, the tumor showed hypointensity on T1-weighted images and hyperintensity on proton density and T2-weighted images with linear low-signal bands in the skin and subcutaneous layers as well as intense enhancement on T1-enhanced images. Although MCC has nonspecific imaging features, these characteristics may be helpful for the early diagnosis of this disease.

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique (램파 혼합 기법을 이용한 알루미늄 합금의 부식 결함 검출에 대한 실험 연구)

  • Choi, Heeung;Lee, Jaesun;Cho, Younho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.919-925
    • /
    • 2016
  • In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

An Optimization Approach for Localization of an Indoor Mobile Robot (최적화 기법을 사용한 실내 이동 로봇의 위치 인식)

  • Han, Jun Hee;Ko, Nak Yong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.253-258
    • /
    • 2016
  • This paper proposes a method that utilizes optimization approach for localization of an indoor mobile robot. Bayesian filters which have been widely used for localization of a mobile robot use many control parameters to take the uncertainties in measurement and environment into account. The estimation performance depends on the selection of these parameter values. Also, the performance of the Bayesian filters deteriorate as the non-linearity of the motion and measurement increases. On the other hand, the optimization approach uses fewer control parameters and is less influenced by the non-linearity than the Bayesian methods. This paper compares the localization performance of the proposed method with the performance of the extended Kalman filter to verify the feasibility of the proposed method. Measurements of ranges from beacons of ultrasonic satellite to the robot are used for localization. Mahalanobis distance is used for detection and rejection of outlier in the measurements. The optimization method sets performance index as a function of the measured range values, and finds the optimized estimation of the location through iteration. The method can improve the localization performance and reduce the computation time in corporation with Bayesian filter which provides proper initial location for the iteration.

Improvement in the Quality of Ultrasonographic Images Using Wavelet Conversion and a Boundary Detection Filter (Wavelet 변환과 경계선 검출 필터를 이용한 초음파 영상의 화질증대)

  • Han, Dong-Kyun;Rhim, Jae-Dong;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • The present study proposed a method that dissolves ultrasonographic images into multiple resolutions using wavelet conversion and a boundary detection filter and improves the quality of ultrasonographic images through boundary detection filtering. In order to reduce noises and strengthen edges, the proposed method adjusted selectivity coefficient by area step by step from a low resolution image obtained from wavelet converted images to a high resolution image and performed edge filtering in consideration of direction. Through this method, we generated a selective low pass filtering effect in areas except edges by decreasing the wavelet coefficient for pixels in spot areas, improved continuity by smoothing edges in the tangential direction, and enhanced contrast by thinning in the normal direction. Through an experiment, we compared the filtering method using a non linear anisotropic expansion model and the filtering method using wavelet contraction structure in single resolution.

  • PDF

Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle (레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파)

  • Kwon, Sung-D.;Kwon, Yong-G.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The angular dependence (or profile) of backscattered ultrasound was measured for steel specimens with a range of surface roughness, $1{\sim}71{\mu}m$. Backscattering profiles at or near the Rayleigh angle still showed roughness dependence while the assessment of surface roughness via normal profile became impossible due to the paint layer masking the roughness. The peak amplitude directly radiated at the Rayleigh angle was proportional to the surface roughness, while the averaged peak amplitude radiated from the backward propagating Rayleigh wave, produced by reflection at a corner, was inversely proportional. In the painted specimens, the linearity of direct backward radiation with the roughness was observed even at the roughness of less than three hundredths of a wavelength, and the abnormal multiple bark reflection caused by periodic roughness disappeared.

Acoustic Properties of Ultrasonic Transducer Using Piezocomposites (압전복합재료를 이용한 초음파 트랜스듀서의 음향 특성)

  • Lee, Sang-Wook;Ryu, Jeong-Tag;Nam, Hyo-Duk;Kim, Yeon-Bo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.80-86
    • /
    • 2007
  • We have investigated on the development of 2-2 type piezocomposites that have better piezoelectric activity and lower acoustic impedance than those of conventional piezoceramics. In this study, we have investigated the piezoelectric and acoustic properties of 2-2 type piezocomposites sensor which was fabricated using dice-and-fill technique for the different volume fraction of PZT. The specific acoustic impedance of 2-2 type piezocomposites decreased linearly when PZT volume fraction was decreased. The resonance characteristics measured by an impedance analyzer(HP4194A) were similar to the analysis of finite element method (FEM). The resonance characteristics and the electromechanical coupling factor were the best when the volume fraction PZT was 0.6. It also showed the highest result from the standpoint of sensitivity, bandwidth and ring-down property and so on at the same condition. The specific characteristics show that the 2-2 type piezocomposites turned out to be superior to the ultrasonic sensor composed by single phase PZT.