• Title/Summary/Keyword: 비선형 관성

Search Result 84, Processing Time 0.022 seconds

Nonlinear Filtering Approaches to In-flight Alignment of SDINS with Large Initial Attitude Error (큰 초기 자세 오차를 가진 관성항법장치의 운항중 정렬을 위한 비선형 필터 연구)

  • Yu, Haesung;Choi, Sang Wook;Lee, Sang Jeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.4
    • /
    • pp.468-473
    • /
    • 2014
  • This paper describes the in-flight alignment of SDINS (Strapdown Inertial Navigation Systems) using an EKF (Extended Kalman Filter) and a UKF (Unscented Kalam Filter), which allow large initial attitude error uncertainty. Regardless of the inertial sensors, there are nonlinear error dynamics of SDINS in cases of large initial attitude errors. A UKF that is one of the nonlinear filtering approaches for IFA (In-Flight Alignment) are used to estimate the attitude errors. Even though the EKF linearized model makes velocity errors when predicting incorrectly in case of large attitude errors, a UKF can represent correctly the velocity errors variations of attitude errors with nonlinear attitude error components. Simulation results and analyses show that a UKF works well to handle large initial attitude errors of SDINS and the alignment error attitude estimation performance are quite improved.

Position Control for AC Servo Motor Using a Sliding Mode Control (슬라이딩 모드제어에 의한 교류 서보 전동기의 위치제어에 관한 연구)

  • 홍정표;홍순일
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.3
    • /
    • pp.210-215
    • /
    • 2004
  • The dynamic model of ac servo motor is influenced very much due to rotor resistance change and nonlinear characteristic. By using the sliding mode control the dynamic behavior of system can be made insensitive to plant parameter change and external disturbance. This paper describes the application of the sliding mode control for position control of ac servo motor. The control scheme is derived and designed. A design method based on external load parameters has been developed for the robust control of ac induction servo drive. The proposed control scheme are given based on the variable structure controller and slip frequency vector control. Simulated results are given to verify the proposed design method by adoption of sliding mode and show robust control for a change of shaft initial J, viscous friction B and torque disturbance.

  • PDF

Performance Analysis of an Electro-Hydrostatic Actuator (Electro-Hydrostatic Actuator의 성능해석)

  • Kim, Do-Hyun;Kim, Doo-Man;Hong, Yeh-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.316-322
    • /
    • 2007
  • The EHA(Electro-hydrostatic Actuator) reveals completely different characteristics from the conventional valve-controlled Electro-hydraulic actuators. In this paper, its mathematical model including nonlinear elements was derived to be verified by experiments. Based on this, a simulation program was developed for the EHAs consisting of an electric motor driven hydraulic pump, pipe lines and a cylinder. The influence of important design parameters such as peak motor torque and rotational inertia moment of the hydraulic pump on control performance was investigated, where the test condition was intentionally selected so that the motor torque was saturated during the transient phase. As a result, design requirements for improving the control accuracy under full speed operation conditions of the EHAs were investigated.

Research of Synthetic Resonance Characteristics for Electrohydraulic Thrust Vector Control Actuation System (전기-유압식 추력벡터제어 구동장치시스템의 합성공진 특성 연구)

  • Min, Byeong-Joo;Choi, Hyung-Don;Kang, E-Sok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.151-160
    • /
    • 2008
  • In this paper, the analysis results of synthetic resonance characteristics are described for the electrohydraulic thrust vector control actuation system. The synthetic resonance is induced by integration of position servo actuation system on the flexible launch vehicle mounting structure. The new resonance mode is synthesized due to composition of hydraulic resonance for electrohydraulic position servo system with inertia load condition and structural resonance for flexible mounting structure. This synthetic resonance can make stability of control system worse by feedback and amplification of control system. The exact nonlinear analysis model of this phenomenon is developed to predict and design a control algorithm for improvement characteristics. The DPF (Dynamic Pressure Feedback) control algorithm has been designed and has excellent resonance suppression capability.

  • PDF

Earthquake Simulation Tests on a 1:5 Scale 10-Story R.C. Residential Building Model (1:5 축소 10층 내력벽식 R.C. 공동주택의 지진모의실험)

  • Lee, Han-Seon;Hwang, Seong-Jun;Lee, Kyung-Bo;Kang, Chang-Bum;Lee, Sang-Ho;Oh, Sang-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.67-80
    • /
    • 2011
  • This paper presents the results of shaking table tests on a 1:5 scale 10-story R.C. wall-type residential building model. The following conclusions are drawn based on the test results. (1) The model responded linear elastically under the excitations simulating an earthquake with a return period of 50 years, and showed a nonlinear response under the excitations simulating the design earthquake of Korea. (2) The model showed a significant strength drop under the maximum considered earthquake, with a return period of 2400 years. (3) The major portion of the resistance to lateral inertia forces came from the walls used for the elevator and stair case. (4) Finally, the damage and failure modes appear to be due to the flexural behavior of walls and slabs. A significant deterioration of stiffness and an elongation of the fundamental periods were observed under increased earthquake excitations.

Parametric Study of Dynamic Soil-pile-structure Interaction in Dry Sand by 3D Numerical Model (3차원 수치 모델을 이용한 건조사질토 지반-말뚝-구조물 동적 상호작용의 매개변수 연구)

  • Kwon, Sun-Yong;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.9
    • /
    • pp.51-62
    • /
    • 2016
  • Parametric studies for various site conditions by using 3d numerical model were carried out in order to estimate dynamic behavior of soil-pile-structure system in dry soil deposits. Proposed model was analyzed in time domain using FLAC3D which is commercial finite difference code to properly simulate nonlinear response of soil under strong earthquake. Mohr-Coulomb criterion was adopted as soil constitutive model. Soil nonlinearity was considered by adopting the hysteretic damping model, and an interface model which can simulate separation and slip between soil and pile was adopted. Simplified continuum modeling was used as boundary condition to reduce analysis time. Also, initial shear modulus and yield depth were appropriately determined for accurate simulation of system's nonlinear behavior. Parametric study was performed by varying weight of superstructure, pile length, pile head fixity, soil relative density with proposed numerical model. From the results of parametric study, it is identified that inertial force induced by superstructure is dominant on dynamic behavior of soil-pile-structure system and effect of kinematic force induced by soil movement was relatively small. Difference in dynamic behavior according to the pile length and pile head fixity was also numerically investigated.

Topology Optimization of Incompressible Flow Using P1 Nonconforming Finite Elements (P1 비순응 요소를 이용한 비압축성 유동 문제의 위상최적화)

  • Jang, Gang-Won;Chang, Se-Myong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1139-1146
    • /
    • 2012
  • An alternative approach for topology optimization of steady incompressible Navier-Stokes flow problems is presented by using P1 nonconforming finite elements. This study is the extended research of the earlier application of P1 nonconforming elements to topology optimization of Stokes problems. The advantages of the P1 nonconforming elements for topology optimization of incompressible materials based on locking-free property and linear shape functions are investigated if they are also valid in fluid equations with the inertia term. Compared with a mixed finite element formulation, the number of degrees of freedom of P1 nonconforming elements is reduced by using the discrete divergence-free property; the continuity equation of incompressible flow can be imposed by using the penalty method into the momentum equation. The effect of penalty parameters on the solution accuracy and proper bounds will be investigated. While nodes of most quadrilateral nonconforming elements are located at the midpoints of element edges and higher order shape functions are used, the present P1 nonconforming elements have P1, {1, x, y}, shape functions and vertex-wisely defined degrees of freedom. So its implentation is as simple as in the standard bilinear conforming elements. The effectiveness of the proposed formulation is verified by showing examples with various Reynolds numbers.

Optimum Subband Quantization Filter Design for Image Compression (영상압축을 위한 최적의 서브밴드 양자화 필터 설계)

  • Park, Kyu-Sik;Park, Jae-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.12B no.4 s.100
    • /
    • pp.379-386
    • /
    • 2005
  • This paper provides a rigorous theory for analysis of quantization effects and optimum filter bank design in quantized multidimensional subband filter banks. Even though subband filter design has been a hot topic for last decades, a few results have been reported on the subband filter with a quantizer. Each pdf-optimized quantizer is modeled by a nonlinear gain-plus-additive uncorrelated noise and embedded into the subband structure. Using polyphase decomposition of the analysis/synthesis filter banks, we derive the exact expression for the output mean square quantization error. Based on the minimization of the output mean square error, the technique for optimal filter design methodology is developed. Numerical design examples for optimum nonseparable paraunitary and biorthogonal filter banks are presented with a quincunx subsampling lattice. Through the simulation, $10\~20\;\%$ decreases in MSE have been observed compared with subband filter with no quantizers especially for low bit rate cases.

압전형 가속도계의 설계, 제작 및 보정 I

  • 이종원;구경회
    • Journal of the KSME
    • /
    • v.29 no.2
    • /
    • pp.175-183
    • /
    • 1989
  • 오늘날 널리 연구되고 있고 공학자들에게 많은 관심을 끌고있는 압전 세라믹(ceramic)을 이용 하여 자연계에서 일어나는 각종 진동현상을 측정하고 해석하기 위한 센서(sensor)의 설계, 제작은 이미 선진국에서도 보편화된지 오래이다. 특히 압전형 가속도계(piezo type accelerometer)는 진동의 절대 측정에 가장 유용한 센서로 널리 알려져 있다. (1) 아주 넓은 사용 주파수 범위 (2) 넓은 동적범위(dynamic range)에 걸친 뛰어난 선형성(linearity) (3) 측정된 가속도 신호를 전기적으로 적분하여 속도와 변위에 대한 자료 제공 용이 (4) 높은 정확성 (5) 자발 전(self-generating)이므로 외부 전원 공급이 불필요 (6) 수명과 뛰어난 내구성 (7) 작은 크기와 가벼운 무게 등이다. 현재 기계 구조물 진동 측정에 이용되고 있는 스트레인 게이지 형(strain gage-type)의 가속도계는 감도가 좋고 저주파 진동 측정에는 편리한 반면 충격이나 높은 주파수 전동 측정에는 적합하지 않으며 내부 구조가 다소 복잡하다(2). 반면에 압전형 가 속도계는 압전 소자와 관성 질량의 조합 설계로서 저주파 진동 측정에 적합한 고감도의 가속도 계와, 감도는 떨어지나 아주 높은 주파수 범위의 진동까지 측정이 가능한 가속도계를 손쉽게 설계, 제작할 수 있다. 본 글에서는 선진국에 비해 낙후된 국내의 센서 설계, 제작 기술을 고 양시키고자 최근 한국과학기술원에서 시도된 압전형 가속도계의 개발 연구 사례를 중심으로 설계 및 제작시 고려 사항과 보정 문제를 소개하고자 한다.

  • PDF

Free Vibrations of Elastica Shaped Arches (Elastica형 아치의 자유진동)

  • Lee, Byoung Koo;Oh, Sang Jin;Lee, Tae Eun;Kim, Gwon Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.827-833
    • /
    • 2008
  • This paper deals with the free vibrations of elastica shaped arches. The elastica shaped arches are formed by the post-buckled column whose arc length is always constant. The equations governing free, planar vibration of general arch in open literature are modified for applying the free vibrations of elastica shaped arch and solved numerically to obtain frequencies and mode shapes for hinged-hinged, clamped-hinged and clamped-clamped end constraints. The effects of rotatory inertia, rise ratio and slenderness ratio on natural frequencies are presented. The frequencies of elastica shaped arches are greater than those of parabolic shaped ones. Also, typical mode shapes are presented in figures.