• Title/Summary/Keyword: 비상 정지

Search Result 76, Processing Time 0.026 seconds

Deduction of Emergency Stop Situation Factors for Water Electrolysis Facilities (수전해 설비에 대한 비상정지상황 발생 요인 도출)

  • HYEONKI KIM;TAEHUN KIM;KWANGWON RHIE;DOOHYOUN SEO;DONGMIN LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.722-727
    • /
    • 2023
  • There are various types of hydrogen production methods, but among them, the alkaline water electrolysis method produces hydrogen by electrolyzing water, and unlike other methods, it can produce green hydrogen that does not emit pollutants and greenhouse gases. There are many different potential risk factors inherent in the water electrolysis process. So it is necessary to predict an emergency situation in advance and to safely manage and take countermeasures according to the emergency situation. Korea Gas Safety Corporation (KGS) CODE AH271 stipulates legal matters to secure safety, but it is not detalied. Thus it is necessary to take measures to safely control and manage it according to the situation in which an emergency stop is required. In this study, based on KGS CODE and HAZOP for alkaline water electrolysis facilities, factors that can cause emergency situations were derived and countermeasures were prepared.

A Study on the Development of Emergency Stop Safety Manual for Alkaline Water Electrolysis (알칼라인 수전해 설비의 비상정지 안전운전 매뉴얼 개발 연구 )

  • HYEONKI KIM;KWANGWON RHIE;TAEHUN KIM;SUNGCHUL HONG;DONGMIN LEE;DANBEE SHIN;DOOHYOUN SEO
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.460-467
    • /
    • 2024
  • As the hydrogen economy receives attention, much research has been conducted on water electrolysis that can produce green hydrogen. After investigating the various risk factors that exist in the alkaline water electrolysis process through hazard and operability study and job safety analysis, which are risk assessments, measures to ensure safety were prepared and made into a manual. Possible risks that could occur during various emergency stop situations and operations were identified, and leakage of potassium hydroxide (KOH) and hydrogen used as electrolyte appeared to be the main risk. If you utilize a risk assessment for the relevant equipment when writing a manual, you will be able to prepare work procedures that substantially reduce risk factors.

Multi Remote Control of Ship's Emergency Lighting Power Supply (선박 비상조명 전원장치의 다중 원격제어)

  • Lee Sung-Geun;Lim Hyun-Jung
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.859-863
    • /
    • 2005
  • This paper describes the improvement of power control characteristics of ship's emergency lighting power supply(SELPS), by which electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication. Proposed system is composed of step-down converter(SDC), emergency power supply circuit(EPSC), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit, microprocessor control and multi communication circuit. Experimental works confirm that relative system stops when over current is detected and speedy and stable emergency power is supplied when main power source cut-off, and controls input power up to 35[$\%$] by adjusting pulse frequency of the HB inverter, and ON-OFF control of multiple SELS, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PC communication.

Failure Cause Analysis for Loss of Off-site Power Test during Normal Full Power Operation On Wolsong-4 NPP (월성원전 4호기 전 출력 운전시 소외전원상실시험 실패 원인분석)

  • Chang, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.175-181
    • /
    • 2000
  • 월성원자력4호기가 '99.06.09일 11:53분 경 전출력 소외전원상실시험시 주발전기 병입차단기 및 기동용변압기 차단기의 트립과 동시에 예상 밖의 13.8Kv 원자로 냉각재펌프모터#3(9.000HP)이 순시과전류 보호계전기(50Y) 동작으로 트립되어 이로 인한 냉각재 저유량으로 원자로 제1정지계통이 동작되고 원자로가 비상정지 되어 동 시험이 실패되었음. 이 비정상적인 고장은 예비디젤발전기의 수동 기동 병입과 터빈 수동 정지 및 주발전기 트립후 적절한 조치로 소내전원은 정상적으로 복구되었음. 이에 대해 냉각재펌프모터#3의 순시과전류 동작 원인을 유도전동기의 전원상실 후 발생되는 잔류전압(Residual Voltage)과 공급 모선전압(Bus Voltage) 측면에서 분석하며, 모터의 회전속도, 위상각, 잔류전압크기 변화 및 신속개방 절체시 냉각재펌프모터의 돌입 기동전류를 계산하고, PSS/E 프로그램을 사용한 간략한 모의 사례로 검증하였으며 이에 대한 재발방지를 위한 대책을 제시함.

  • PDF

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.

A Study of Analytical Integrity Estimations for the Structure and Rotor System of an Emergency Diesel Generator (비상디젤발전기의 회전체 및 구조물 해석적 건전성 평가에 관한 연구)

  • Kim, Chae-Sil;Choi, Heon-Oh;Jung, Hoon-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.79-86
    • /
    • 2014
  • This paper describes an integrity evaluation method for emergency diesel generator(EDG) and rotor part of EDG. EDG is a very important equipment in the nuclear power plant(NPP). EDG supplies electricity to the safety-related equipments for the safety shut down of NPP in an emergency situation of earthquake. The safety of the rotor part of EDG is also important during seismic impact from earthquake. The finite element modelling of the EDG including rotor part was constructed. The modal analysis of EDG was firstly performed. The first natural frequency was calculated and revealed higher than the cutoff frequency of seismic spectrum. Then the stress analysis was done to compare with the allowable stress. The safety of the rotor part was investigated by the finite element analysis of the rotor and journal bearing interaction to find film thickness and critical speed. The seismic load was applied to rotor part in a manner that the load was a weighted static load. Analysis results showed that the maximum stress was within the range of allowable stress and the film thickness is larger than the permissible minimum thickness, and the critical speed was out of the operating speed. Hence, the structural and dynamic integrity of EDG could be confirmed by the numerical analysis method used in this paper. However, dynamic analysis of a rotating rotor and supporting bearing with the seismic impact needs to be investigated in a more rigorous method since the seismic load to the rotating part complicates the behavior of rotating system.

Vehicle Emergency Lamp Fuzzy Control Systems Using The GPS (GPS를 이용한 자동차 비상등 작동 장치)

  • Kwon, Yunjung;Nam, Sangyep
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.276-281
    • /
    • 2014
  • Necessities of a traffic means work a car in the modern society human to an usability of a life is enjoying. On the other hand, the damage by traffic accident increment the human quotient worked as we were in proportion to the vehicle which increased. Passing an examination moves necessarily on an obstacle to suddenly appear at the fronts if a car travels and the vehicles which stopped suddenly. Dynamic passing an examination about an obstacle turn on Vehicle Emergency Lamp to by hand when is unhurried, and can turn off, but to appear urgently dynamic passing an examination in time human is instinctive, but cannot inform an emergency to a back vehicle, and a rear-end collision occurs. A car we synthesize a speed of a vehicle, and this unit analyzes as we use GPS, and to drive runs Vehicle Emergency Lamp to automatic in the situations that shall turn on emergencies etc. If a speed of a vehicle continuously slows down in too high-speed driving or low-speed driving, or we are stopped, Vehicle Emergency Lamp is always turned on. It was built if we rise again as clearing itself from risk, and a speed of a vehicle judges, and we turn off Vehicle Emergency Lamp to automatic. It runs till rear-end collision sensor operates, and by hand reset does Vehicle Emergency Lamp a driving vehicle collides from behind to a back vehicle or when a driving vehicle was overthrown. It is shortened very much to the chain rear-end collision traffic accident that is a traffic accident of large size if we use this unit. And we did authentication through the experiment which a driver was helpful to unnecessary operation and a relaxed safe driving during drivings.

고리 원전 4호기 - 국내 최장 423일간 한 주기 무정지 안전 운전 달성

  • 전재풍
    • Nuclear industry
    • /
    • v.16 no.5 s.159
    • /
    • pp.30-41
    • /
    • 1996
  • 고리 4호기가 지난 4월 5일 국내 최장인 423일간(95. 2. 8$\~$96. 4. 5)의 한 주기 무정지 안전 운전을 달성하고 계획 예방 정비를 위해 정지했다. 이러한 쾌거는 지속적인 설비 환경 개선과 철저한 계획 예방 정비를 통해 기계고장률을 제로화하고, 각종 훈련을 통해 운전원들의 운전 능력과 비상 대응 능력을 향상시킨 결과라 할 수 있다. 국내 최장 OCTF 달성의 성과 의의와 과정을 들어본다.

  • PDF

Multi-Cutting Machine for TJ Coupler production (TJ 커플러 제작용 멀티 절삭기)

  • Kim, Jae-Jin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.337-338
    • /
    • 2016
  • 본 논문에서는 TJ 커플러 제작용 멀티 절삭기에 대해 제안하였다. TJ 커플러 제작용 멀티 절삭기는 동시에 2개 이상의 커플러를 절삭할 수 있는 기능을 수행하면서 안전성을 확보할 수 있는 절삭기이다. 커플러의 종류에 따른 절삭이 이루어 질 수 있도록 절단석과 연마석을 고정하는 장치를 개발하였다. 또한 작업 환경에 대한 안전성을 확보하기위해 비상정지와 기능상의 정지 기능을 추가하여 안전하면서 빠르게 절삭 작업 수행이 가능하도록 하였다. 절단된 커플러에 대해 반자동으로 수거가 되며 쉽게 새로운 커플러를 고정시킬 수 있도록 고정 및 수거 장치를 포함하여 현재의 절삭기보다 빠르고 효과적인 작업이 가능할 것이다.

  • PDF

A Development of Condition Monitoring System of Pull Cord Switch (풀 코드 스위치 상태 모니터링 시스템 개발)

  • Yang, Chul-Oh;Kim, Jun-Young;Lee, Dae-Sung;Kim, Dae-Hong;Park, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1835-1836
    • /
    • 2008
  • 풀 코드 스위치(Pull Cord Switch)는 컨베이어 벨트를 비상 정지시키기 위한 스위치로, 정지된 스위치 또는 미 복귀 스위치의 위치를 파악하는 문제가 시스템 가동시간과 밀접한 관계를 가지고 있다. 현재 전력선을 이용한 방법, 단방향 무선통신을 이용한 방법 등이 사용되고 있으나, 별도의 유선가설이나 통신장애 등의 문제점을 가지고 있다. 따라서 본 연구에서는 USN(Ubiquitos Sensor Network)을 이용한 상태모니터링시스템을 제안하고 그 가능성을 보였다.

  • PDF