• Title/Summary/Keyword: 비방사능

Search Result 393, Processing Time 0.025 seconds

Optogalvanic Spectroscopy of U, Th and Rb using Diode Lasers (반도체 다이오드 레이저를 사용한 U, Th 및 Rb 의 Optogalvanic Spectroscopy 에 관한 연구)

  • Lee, Sang Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.1
    • /
    • pp.34-40
    • /
    • 1994
  • First observation of uranium using a diode laser was published recently. The experiment was performed by the optogalvanic spectroscopy using diode lasers. A laser source causes the current change in a hollow cathode discharge lamp when metal atoms in plasma absorb the diode laser light. The optogalvanic signal is collected by detecting the current change. This work is the extended investigation of our previous research, the uranium detection using a diode laser. New electronic transitions of uranium and thorium in 775∼850 nm were investigated using diode lasers. In addition, the Rb(Ⅰ) optogalvanic spectra at 780.02 nm and 794.76 nm were studied. The Rb(Ⅰ) spectrum at 780.02 nm showed the isotopic features and hyperfine splittings. This work provides a key idea that the diode lasers are useful in the specrochemical analysis of the radioactive actinides that have a rich spectrum with transitions which can be easily reached with AlGaAs diode lasers. Also, this study shows that the diode lasers can be an important tool to find the spectroscopic parameters of actinides and rare earth elements which have not known.

  • PDF

Development of $^{169}Yb$ Low-Energy Sealed Source for Nondestructive Testing Applications Utilizing HANARO (하나로를 이용한 비파괴검사용 $^{169}Yb$ 저에너지 밀봉선원 개발)

  • Son, K.J.;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Seo, K.S.;Han, I.S.;Cho, W.K.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • [ $^{169}Yb$ ] industrial NDT sealed sources were developed by using $Yb_2O_3$ pellets as the target and demonstrated for their performance. To produce the pellets, optimal compacting and sintering conditions were determined experimentally. Source holders for $^{169}Yb$ were designed and fabricated. After assembling an active source produced from HANARO with the developed source holder, a demonstration experiment was performed to compare the quality of the radiographs from $^{192}Ir$ and soft X-rays. This demonstration study showed that the developed $^{169}Yb$ produced better radiographs than $^{192}Ir$ for a carbon steel with less than a 4 mm thickness.

Determination of Transuranic Elements in Radwaste Samples from Nuclear Power Plant (원전발생 방사성폐기물 시료 중 초우란원소의 정량)

  • 조기수;김태현;전영신;지광용;김원호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.351-357
    • /
    • 2003
  • Transuranic elements such as Pu, Am and Cm in synthetic solution of spent nuclear fuel samples were determined by electrodeposition followed by alpha-spectrometry after separation using anion exchange and extraction chromatography in order to determine the transuranic elements in radwaste samples from nuclear power plants. Plutonium was separated by 12M HC1-0.1M HI as an eluent on anion exchange column. As a second step Am and Cm were separated in a group by DTPA-Lactic acid as the eluent on HDEHP coated column. The nuclides of $^{239}Pu$, $^{241}Am$$^{244}Cm$ separated were determined by alpha-spectrometry after electrodeposition in 0.1M $NaHSo_4$-0.53M $Na_2SO_4$buffer solution as an electrolyte. The recovery yields of $^{239}Pu$, $^{241}Am$$^{244}Cm$ were 83.8%, 85.2% and 86.3%, respectively, from the synthetic solution containing uranium and non-radioactive metal elements.

  • PDF

A Study on the Shielding Analysis in Vitrification Facility of Low-and Intermediate Level Radioactive Wastes ($\cdot$저준위 방사성폐기물 유리화 시설의 차폐해석에 관한 연구)

  • 이창민;이건재;지평국;박종길;하종현;송명재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.524-531
    • /
    • 2003
  • The usefulness of vitrification technology for low- and intermediate- level radioactive wastes was demonstrated because of high volume reduction, mechanical and chemical stability of final waste forms. Thus, a construction of the commercial vitrification plant Is currently promoted. Due to the high radiation level of the waste, shielding analysis has to be carried out for safe design in a vitrification facility. Because there has been no experience in the construction and operation of the vitrification facility in Korea, in this study, in order to get some information for help the detailed design and plan for operation in vitrification facility, shielding analysis for each facility in pilot plant is carried out by using source term from established study. For the selection of the shielding material, concrete was chosen compared to the lead because of economic advantage, weight consideration, and thermal resistance.

  • PDF

Assessment of the Models for Predicting the Thermal Conductivity of Saturated Kaolinite (포화된 카올리나이트를 이용한 열전도계수 예측모델의 신뢰성 검토)

  • Lee, Jangguen;Kim, Hakseung;Kang, Jaemo;Kim, Youngseok;Bae, Gyujin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.21-27
    • /
    • 2012
  • Estimating the thermal conductivity of clayey soils is important for enhancing the performance of geoengineering structures in cold regions and clay barriers for nuclear waste repositories, but specimen disturbance, saturation, and heat boundary conditions of the test apparatus hinder reliable measurements of the thermal conductivity of saturated clayey soils. This paper presents the results of an experimental study carried out using modified consolidation tests with the needle probe method to measure thermal conductivity. Experimental consolidation tests with saturated kaolinite were performed to investigate the effect of effective stress and dry density on thermal conductivity for saturated kaolinite. In addition, thermal conductivity of soil particles were thoroughly investigated and experimental results were used to evaluate the accuracy of the models to predict thermal conductivity.

Immunological Studies on the Surface Antigens of Tumor Cells (종양세포 표면항원에 대한 분자면역학적 연구)

  • 김한도;김규원
    • The Korean Journal of Zoology
    • /
    • v.32 no.2
    • /
    • pp.142-152
    • /
    • 1989
  • We have produced a new monoclonal antibody detecting common acute lymphoblastic leukemia antigen (CALLA) and designated as KP-22. CALIA detected by KP-22 is expressed on the all of the various cefl lines examined including common ALL. Burkitt's lymphoma, human fibroblasts and cultured normal human fibroblasts. However out of cell lines tested, a fraction of J-ALL and all of myelocytic leukemia and all other nonleukemia cell lines except for fibroblast are CALIA negative. Immunoprecipitation of solubilized 125 I-labeled membrane proteins from cultured human fibroblasts and leukemia cell lines with KP-22 revealed a major polypeptide chain with an apparent molecular weight of approximately 100 Kd and 95 Kd, respectively. Even though a microheterogeneity in terms of molecular weight between two CALLAs, the peptide mapping patterns of them &e identical indicating that such a microheterogeneity seems to be partly due to heterogeneous terminal sialic acid compositions added by a posttranslational modification process.

  • PDF

Thermal Release of LiCl Waste Salt from Pyroprocessing (파이로프로세싱 발생 LiCl염폐기물의 열발생)

  • Kim, Jeong-Guk;Kim, Kwang-Rag;Kim, In-Tae;Ahn, Do-Hee;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.73-78
    • /
    • 2009
  • The decay heat of Cs and Sr contained in a LiCl waste salt, generated from an electrolytic reduction process in pyroprocessing of spent nuclear fuel, has been calculated. The calculation has been carried out under some assumptions that most of the LiCl waste is purified and recycled to main process, and the residual is fabricated to make a waste form. As a result, the decay heat from daughter nuclides such as Ba and Y seems to be maximum 4.6 times higher than that from their parent nuclides such as Cs and Sr. The thermal release from Cs and Sr in the LiCl waste is the maximum around the first one month, so an cooling system operation for some time at the beginning would be suggested to control a rapid increase in the temperature of the LiCl waste salt.

  • PDF

The system design for contents measurement of density and moisture in compaction (성토의 밀도 및 수분 함량을 측정하기 위한 시스템 설계)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2002
  • In this study, to measure the density and moisture of compaction, it is designed to use the 2 neutron and 5 gamma-ray detectors. Also, it can be know that Co-60 gamma-ray and Cf-252 neutron source are more useful for this system, because discharge of radiation are better than other sources. They are more profitable to improve their accuracy. Especially, to remove the interference of their reciprocal action between neutron and gamma-ray detectors it is designed shield materials with lead between 2 neutron and 5 gamma-ray detectors each other. It is performed the optimal design to shield under the suggested values completely. Because this system will use portable, so decrease of their weight are so important. For this reason, it can be decrease their weight of 5.2[kg] with shield material between each detectors and it can be think mote easy to carry and use on the industrial Spot.

  • PDF

Implementation of 3D Video using Time-Shortening Algorithm (시간단축 알고리즘을 통한 3D 동영상 구현)

  • Shin, Jin-Seob;Jeong, Chan-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.123-128
    • /
    • 2020
  • In this paper, we presents a new cone beam computerized tomography (CBCT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time. And we showed the Rotation-based method was good rather than existing reconstruction technique for 3D images, also found weakness and a solution for it.

Evaluation of Liver Function Using $^{99m}-Lactosylated$ Serum Albumin Liver Scintigraphy in Rat with Acute Hepatic Injury Induced by Dimethylnitrosamine (Dimethylnitrosamine 유발 급성 간 손상 흰쥐에서 $^{99m}-Lactosylated$ Serum Albumin을 이용한 간 기능의 평가)

  • Jeong, Shin-Young;Seo, Myung-Rang;Yoo, Jeong-Ah;Bae, Jin-Ho;Ahn, Byeong-Cheol;Hwang, Jae-Seok;Jeong, Jae-Min;Ha, Jeong-Hee;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.418-427
    • /
    • 2003
  • Objects: $^{99m}-lactosylated$ human serum albumin (LSA) is a newly synthesized radiopharmaceutical that binds to asialoglycoprotein receptors, which are specifically presented on the hepatocyte membrane. Hepatic uptake and blood clearance of LSA were evaluated in rat with acute hepatic injury induced by dimethylnitrosamine (DMN) and results were compared with corresponding findings of liver enzyme profile and these of histologic changes. Materials and Methods: DMN (27 mg/kg) was injected intraperitoneally in Sprague-Dawley rat to induce acute hepatic injury. At 3(DMN-3), 8(DMN-8), and 21 (DMN-21) days after injection of DMN, LSA injected intravenously, and dynamic images of the liver and heart were recorded for 30 minutes. Time-activity curves of the heart and liver were generated from regions of interest drawn over liver and heart area. Degree of hepatic uptake and blood clearance of LSA were evaluated with visual interpretation and semiquantitative analysis using parameters (receptor index : LHL3 and index of blood clearance : HH3), analysis of time-activity curve was also performed with curve fitting using Prism program. Results: Visual assessment of LSA images revealed decreased hepatic uptake in DMN treated rat, compared to control group. In semiquantitative analysis, LHL3 was significantly lower in DMN treated rat group than control rat group (DMN-3: 0.842, DMN-8: 0.898, DMN-21: 0.91, Control: 0.96, p<0.05), whereas HH3 was significantly higher than control rat group (DMN-3: 0.731,.DMN-8: 0.654, DMN-21: 0.604, Control: 0.473, p<0.05). AST and ALT were significantly higher in DMN-3 group than those of control group. Centrilobular necrosis and infiltration of inflammatory cells were most prominent in DMN-3 group, and were decreased over time. Conclusion: The degree of hepatic uptake of LSA was inversely correlated with liver transaminase and degree of histologic liver injury in rat with acute hepatic injury.