• Title/Summary/Keyword: 비방사능

Search Result 393, Processing Time 0.025 seconds

A Modified Protocol for Myocardial Perfusion SPECT Using Natural Plant Extracts for Enhancement of Biliorg Excretion (담즙분비촉진 식물추출물을 이용한 심근관류영상 검사법 개선)

  • Jeong, Hwan-Jeong;Kim, Chang-Guhn
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.364-373
    • /
    • 2003
  • Purpose: For good quality of myocardial perfusion images, an approximately 30 min to 1 hour of waiting time after radiopharmaceutical injection and ingestion of fatty meal are asked of the patients. The aim of this study was to investigate the shortening of waiting time after radiopharmaceutical injection and improvement of image quality using natural plant extracts that promote bile excretion. Materials and Methods: Ten volunteers participated in protocol 1 (7 men, 3 women; mean age, $24.1{\pm}2.4$ years) and protocol 2 (8 men, 2 women; mean age, $26.1{\pm}2.9$ years), respectively. For the modified method of both protocols, subjects took natural plant extracts 15 minutes before the first injection of $^{99m}Tc$ MIBI without laking fatty meals. Control (Conventional) methods were peformed with intake of a fatty meal 20 to 30 minutes after $^{99m}Tc$ MIBI injection. Results: As the results of protocol 1 and 2, the ratio of myocardial to lung ratio were not different between modified and conventional method. Liver to lung ratio of modified method showed significantly lower value than that of conventional method. In modified method, myocardial to liver ratio was higher persistently. In protocol 2, natural plant extracts took before the first injection of $^{99m}Tc$ MIBI exerted accelerating effect of excretion of bile juice into Intestine until the end of examination. Conclusion: These results represent that natural plant extracts for facilitation of bile excretion before injection of $^{99m}Tc$ MIBI may provide better quality of myocardial perfusion images without the need for preparations such as ingestion of fatty meal within the 2 hours compared with conventional method.

Mucociliary Clearance in the Children with Bronchial Asthma (기관지 천식 환아에서의 점액섬모 청소율(Mucociliary Clearance))

  • Lee, Myung-Hyun;Sun, Yong-Han;Nam, Seung-Gon;Koh, Young-Yull;Chung, June-Key
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.173-181
    • /
    • 1996
  • Background : Several studies have suggested that impaired mucociliary clearance plays a role in the pathophysiology of bronchial asthma. Cough productive of mucoid sputum is common, and mucous plugs in the airways are frequently observed. These clinical features are in keeping with the histologic lesions of asthma, which involve primarily the epithelial and mucous-producing structures of the conducting airways. Some studies have shown that the mucociliary clearance is impaired in adult asthma, but it has not been studied in childhood asthma. The objectives of this study were to examine whether the mucociliary clearance is impaired in childhood asthma and to estimate the degree of impairment in comparison with that of immotile cilia syndrome. Method : Thirteen children with mild stable asthma and eight patients with immotile cilia syndrome completed this study. Ten healthy children were recruited as a normal control group. The whole-lung mucociliary clearance was measured by the radioaerosol technique. Aerosols, tin colloid particles tagged with the radionuclide technetium-99m($^{99m}Tc$), were generated by means of nebulizer, and inhaled via a mouthpiece. The retention of radioactivity was measured at 30, 60, 90 and 120 minutes by gamma camera, and mucociliary clearance was calculated as percent retention at each time. Results: 1) In each subject, the percent retention decreased variably with the lapse of time. 2) The percent retention of radionuclide decreased at each time in order of normal control, bronchial asthma and immotile cilia syndrome and the percent retention of immotile cilia syndrome was significantly higher than that of normal control at each time(p<0.05). 3) At two hours, the percent retention of bronchial asthma($65.0{\pm}1.8$(SE)%) was significantly higher than that of the normal control($54.4{\pm}3.5%$, p<0.05), and significantly lower than that of immotile cilia syndrome($73.3{\pm}1.4%$, p<0.01). 4) When the percent retention was analyzed according to $PC_{20}$ in the children with bronchial asthma, they had no relationship with each other. Conclusion: Mucociliary clearance in the children with bronchial asthma was significantly lower than normal control. This finding indicates that impaired mucociliary clearance operates in childhood asthma as well, and suggests that it may be one contributing factor in the pathogenesis of asthma. The degree of impairment, however, was not so severe as immotile cilia syndrome.

  • PDF

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Usefulness of $^{99m}Tc$-MDP Bone Scintigraphy for Assessing Vascular Ingrowth on Hydroxyapatite Ocular Implant ($^{99m}Tc$-MDP 골신티그라피를 이용한 Hydroxyapatite 안구 보충물의 혈관 신생 평가 및 임상적 유용성)

  • Kang, Bong-Joo;Sohn, Hyung-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.484-492
    • /
    • 1999
  • Purpose: This study was to evaluate the clinical usefulness of $^{99m}Tc$-MDP bone scintigraphy for assessing vascular ingrowth into the ocular implants after enucleation or evisceration. Materials and Methods: Twenty-four patients (M:F=7:17, mean age: 36 years), who buried a coralline hydroxyapatite after uncomplicated enucleation or evisceration surgery were studied. Dynamic and static scintigraphy on the orbit fossa were obtained after injection of 740 MBq $^{99m}Tc$-MDP to evaluate the status of vascularization. The study was performed from the 3 to 33 weeks after surgery. According to the visual analysis, activity greater than nasal bridge was graded as 4, equal to the nasal bridge as 3, less than nasal bridge but greater than normal orbit as 2, greater than normal orbit but less than grade 2 as 1. Uptake ratio was also calculated by measuring the implants activity (H) and contralateral orbit activity (N). Grading score and uptake ratio were compared with clinical outcome of vascularization. Additionally, we also analyzed the vascularization status as time lapse between primary surgery and scintigraphic study and surgical methods. Results: Twenty-one patients who had bone scintigraphy at 11 weeks after surgery showed increased uptake above grade 2 and greater H/N ratio than 1.16. Of these, 19 patients who had drilling surgery for permanent peg application showed adequate bleeding during the procedure. The activity grade and uptake ratio were inversely correlated with vascular ingrowth. Higher than grade 2 or greater than 1.56 in H/N ratio seemed to be an indicator for better prognosis. Accomplishment of vascularization was not affected by the surgical way such as enucleation or evisceration. Conclusion: $^{99m}Tc$-MDP bone scintigraphy can be a useful method to evaluate the vascularized status of implants. Adequate time for $^{99m}Tc$-MDP bone scintigraphy may be 11-20 weeks after enucleation or evisceration.

  • PDF

Evaluation of Radioactivity Concentration According to Radioactivity Uptake on Image Acquisition of PET/CT 2D and 3D (PET/CT 2D와 3D 영상 획득에서 방사능 집적에 따른 방사능 농도의 평가)

  • Park, Sun-Myung;Hong, Gun-Chul;Lee, Hyuk;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • Purpose: There has been recent interest in the radioactivity uptake and image acquisition of radioactivity concentration. The degree of uptake is strongly affected by many factors containing $^{18}F$-FDG injection volume, tumor size and the density of blood glucose. Therefore, we investigated how radioactivity uptake in target influences 2D or 3D image analysis and elucidate radioactivity concentration that mediate this effect. This study will show the relationship between the radioactivity uptake and 2D,3D image acquisition on radioactivity concentration. Materials and Methods: We got image with 2D and 3D using 1994 NEMA PET phantom and GE Discovery(GE, U.S.A) STe 16 PET/CT setting the ratio of background and hot sphere's radioactivity concentration as being a standard of 1:2, 1:4, 1:8, 1:10, 1:20, and 1:30 respectively. And we set 10 minutes for CT attenuation correction and acquisition time. For the reconstruction method, we applied iteration method with twice of the iterative and twenty times subset to both 2D and 3D respectively. For analyzing the images, We set the same ROI at the center of hot sphere and the background radioactivity. We measured the radioactivity count of each part of hot sphere and background, and it was comparative analyzed. Results: The ratio of hot sphere's radioactivity density and the background radioactivity with setting ROI was 1:1.93, 1:3.86, 1:7.79, 1:8.04, 1:18.72, and 1:26.90 in 2D, and 1:1.95, 1:3.71, 1:7.10, 1:7.49, 1:15.10, and 1:23.24 in 3D. The differences of percentage were 3.50%, 3.47%, 8.12%, 8.02%, 10.58%, and 11.06% in 2D, the minimum differentiation was 3.47%, and the maximum one was 11.06%. In 3D, the difference of percentage was 3.66%, 4.80%, 8.38%, 23.92%, 23.86%, and 22.69%. Conclusion: The difference of accumulated concentrations is significantly increased following enhancement of radioactivity concentration. The change of radioactivity density in 2D image is affected by less than 3D. For those reasons, when patient is examined as follow up scan with changing the acquisition mode, scan should be conducted considering those things may affect to the quantitative analysis result and take into account these differences at reading.

  • PDF

방사성 폐기물 관리

  • 남장수
    • 전기의세계
    • /
    • v.39 no.11
    • /
    • pp.52-59
    • /
    • 1990
  • 방사성폐기물 관리는 이미 발생된 폐기물에 대하여 처리.처분하는 사후관리라 할 수 있으며 이에 앞서 폐기물의 발생량을 줄이는 방안 즉 사전관리에도 소홀히 해서는 안될 것이다. 사전관리는 방사능 관리구역내 불필요한 물품잔입금지, 소모성자재의 최대한 반복사용(방호복, 제염지등), 공기구동 미소모성자재는 방사능관리구역내 전용화, 제염방법의 개선, 반감기기 극히 짧은 핵종으로만 오염된 폐자재는 방사능이 충분히 감쇄할 때까지 관리구역내에서 보관후 비방사성폐기물로 처리, 폐기물중에서 비방사성폐기물을 분류하여 일반 폐기물 처리, 방사성물질 취급자의 교육등을 통해 방사성폐기물의 발생량을 억제할 수 있을 것이다. 세계 각국은 제각기 현실에 맞는 방사성 폐기물 처리기술을 도입 또는 개발하여 방사성 페기물 처리기술을 도입 또는 개발하여 방사성 폐기물의 양을 감용하거나 최종 폐기물에 대해서는 안전성을 향상시키고 있으며 또 처분은 각국의 지질이나 인문.사회적 환경을 고려하여 최적의 방안을 선택하여 최종처분하고 있다.

  • PDF

Gross-β Level in Dental Ceramic Materials (치과용 세라믹 재료의 전β 방사능 준위)

  • Kim, Sung-Hwan;Jeong, Hyun-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4819-4825
    • /
    • 2010
  • In all of dental ceramics, these materials contained the radio-isotopes with natural abundance ratio. After dental treatment, remained dental ceramics in the oral cavity is caused for human internal dose. In this study, the gross beta activity levels were measured in dental materials including 22 dental ceramics, 1 resin, and 2 cements for estimation of human internal dose. In dental ceramic samples, the obtained results showed that the gross beta activity level varied between 1.317 ~ 2.935 Bq/g and the gross beta activity level was 2.379 Bq/g. And the same level for dentine, opacious dentine, translucent and enamel were 2.479 Bq/g, 2.491 Bq/g, 2.470 Bq/g and 2.069 Bq/g, respectively. The gross beta activity level of temporary resin and cements were negligible, compare to the same level of dental ceramics. The high gross beta activity level observed in opacious dentine code OD-A4 is 2.935 Bq/g thus mainly ascribable to 40K. The reduction of the radiation level of natural radio-isotopes and the improvement of the dental ceramic materials should be required for internal dose reduction.

지하수중의 환경방사능 측정과 응용연구

  • 윤윤열;조수영;이길용;김용제
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.142-146
    • /
    • 2004
  • 지하수중에 존재하는 극미량의 환경방사성 동위원소를 측정하기 위한 방법을 개발하였다. 각 핵종들중 234U, 238U, 222Rn, 226Ra은 섬광액을 포함한 용매추출법을 사용하여 개별분리한 후 액체섬광계수기를 사용하여 각 핵종에서 방출되는 알파선을 검출하였다. 환경방사성 원소인 U과 Th 딸핵종의 비평형에 의한 지하수 특성 연구를 위해서 국내 지하수 중의 234U와 238U의 방사능비 측정을 대전 화강암 지역에서 채취한 지하수 시료를 ICP/MS를 사용하여 U 함량을 결정하고, 지하수에서 U을 용매추출한 후 알파전용 액체섬광계수기를 사용하여 234U와 238U의 방사능을 측정하였다.

  • PDF

Transistor에 의한 고속도계수회로에 관하여

  • 정만영
    • 전기의세계
    • /
    • v.10
    • /
    • pp.62-71
    • /
    • 1963
  • 공업계측분야에 대한 계수기술은 최근획기적인 발전을 거두고있다. 계수화된 계측기는 측정정도에 있어서 개인차나 오산이 없으므로 과거의 눈금식의 계측방식은 이로 대치되어 갈것인데 그 계측 가능한 속도에 있어서 종래의 진공관보다 Transistor식이 되면 훨씬 고속도까지도 계수가 쉽게 되고 장치 및 계수표시용소비전력도 개량되어가고 있다. 이러한것이 되므로서 높은 주파수측정, 짧은 시간측정은 물론이고 전기적인 진폭의 크기를 Analog to Digital 변환기로서 정밀도가 높은 계측을 가능하게 하고 특히 방사능 측정에 있어서 종래의것보다 더 고속화되므로서 방사능의 완전한 성질을 파악할 수 있을 것이다. 그것은 1Cure의 방사능이 3.7*$10^{10}$dps의 붕괴수를 갖고 있으나 현재는 약 2.8*$10^{7}$ cps정도의 계측이 가능할 따름이다. 따라서 계측속도를 더 향상시키므로서 강한 방사능계측도 가능하게 된다. 이러한 고속계수문제의 해결을 하기 위하여 Transistor회로로서 두가지면으로 추구되고 있다. 그 하나는 고속도용 Transistor자체의 개발이며 또하나는 회로적인 개량연구이다. 여기서는 후자에 관해서만 생각하고, 거기에 적합한 Transistor를 얻었을때의 설계기준과 기본적인 실험결과에 관해서 논하기로 한다.

  • PDF