• Title/Summary/Keyword: 비모세관공극

Search Result 26, Processing Time 0.02 seconds

Autogenous Shrinkage and Engineering Properties of the High Strength Concrete Using Soybean and Waste Edible Oil (식물성 유지 및 폐식용유를 사용한 고강도 콘크리트의 자기수축 및 공학적 특성)

  • Han, Min-Cheol;Lee, Dong-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.110-117
    • /
    • 2011
  • This study investigated possibilities for a new reducing shrinkage method of soybean oil(SO) and waste oil(WO) to compare with shrinkage reducing agent(RS) and expansion additive(EA). There was no big difference to flow, air contents, and compressive strength of plain to use SO and WO. For the reducing shrinkage performance, SO and WO was more effective than RS and EA, because their fatty acid reacted with calcium hydroxide of concrete to turn soap. For the pore distribution by porosimter, $0.01{\sim}0.1{\mu}m$ pores of SO and WO were 0 ml/g, and $10{\sim}100{\mu}m$ also remarkably lower than any others. In these results, it inferred that they filled up capillary pore and mitigated autogenous shrinkage by their saponification of their fatty acid and calcium hydroxide.

  • PDF

Capillary Hysteresis Model in Unsaturated Flow : State of The Art (비포화 흐름에서 모세관 이력현상 모형의 고찰 : State of The Art)

  • 박창근;선우중호
    • Water for future
    • /
    • v.25 no.3
    • /
    • pp.65-77
    • /
    • 1992
  • The purpose of this study is to analyse existing hysteresis models and to propose a new type of model. The existing hysteresis models are classified by three types: interpolation model, scaling model and domain model, of which the domain model is based on the theoretical approach. Models which need one branch of hysteresis loop for calibration are developed based on the independent domain concept, however, they are not successful to accurately simulate the real data and Rubicon Sandy Loam and Dune Sand. There is a possibility that a new model is based on the dependent domain model considering the pore blockage effect against air entry for homogeneous porous media(modelIII-1, Mualem, 1984). Concludingly, a new type of hysteresis model is proposed by simplifying ModelIII-1 using a proper assumption.

  • PDF

Development of Polymer-Concrete Composite(I) - Physical Properties of Polymer-Cement Concrete Composites - (폴리머-콘크리트 복합재료 개발(I) - 폴리머-시멘트 콘크리트의 물성 -)

  • Hwang, Eui-Hwan;Kil, Deog-Soo;Oh, In-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.979-984
    • /
    • 1997
  • Test specimens of polymer-cement concrete composites were prepared using styrene-butadiene rubber(SBR) latex, ethylenevinyl acetate(EVA) and polyacrylic ester(PAE) emulsions as polymer dispersions in cement modified system at constant slump($10{\pm}0.5cm$), then compressive and flexural strengths water absorption, pore size distribution, and microstructures were investigated. Compressive and flexural strengths of these composites were remarkably improved with an increase of polymer-cement ratio. These composites had a desirable pore size distribution against frost damage due to a small capillary pore volume. Continuous polymer film was able to form in higher than 15% of polymer cement ratio.

  • PDF

Resistance In Chloride ion Penetration and Pore Structure of Concrete Containing Pozzolanic Admixtures (포졸란재 함유 콘크리트의 세공구조와 염화물이온 침투 저항성)

  • 소양섭;소형석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.100-109
    • /
    • 2002
  • Significant damage to concrete results from the intrusion of corrosive solutions, for example, dissolved chlorides corrode reinforcing steel and cause spatting. Effectively blocks the penetration of these solutions will eliminate or greatly reduce this damage and lead to increased durability. This study is to investigate the effects of pozzolanic admixtures, fly ash and silica fume, and a blast furnace slag on the chloride ion penetration of concretes. The main experimental variables wore the water-cementitious material ratios, the types and amount of admixtures, and the curing time. And it is tested for the porosity and pore size distributions of cement paste, chloride ion permeability based on electrical conductance, and 180-day ponding test for chloride intrusion. The results show that the resistance of concrete to the penetration of chloride ions increases as the w/c was decreased, and the increasing of curing time. Also, concrete with pozzolans exhibited higher resistance to chloride ion penetration than the plain concrete. The significant reduction in chloride ion permeability(charge passed) of concrete with pozzolans due to formation of a discontinuous macro-pore system which inhibits flow. It is shown that there is a relationship between chloride ion permeability and depth of chloride ion penetration of concrete, based on the pore structure (porosity and pore size distributions) of cement paste.

Evaluation of Hydrogeologic Seal Capacity of Mudstone in the Yeongil Group, Pohang Basin, Korea: Focusing on Mercury Intrusion Capillary Pressure Analysis (포항분지 영일층군 이암층의 수리지질학적 차폐능 평가: 수은 모세관 압입 시험의 결과 분석을 중심으로)

  • Kim, Seon-Ok;Wang, Sookyun;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Geological CO2 sequestration is a global warming response technology to limit atmospheric emissions by injecting CO2 captured on a large scale into deep geological formations. The presented results concern mineralogical and hydrogeological investigations (FE-SEM, XRD, XRF, and MICP) of mudstone samples from drilling cores of the Pohang basin, which is the research area for the first demonstration-scale CO2 storage project in Korea. They aim to identify the mineral properties of the mudstone constituting the caprock and to quantitatively evaluate the hydrogeologic sealing capacity that directly affects the stability and reliability of geological CO2 storage. Mineralogical analysis showed that the mudstone samples are mainly composed of quartz, K-feldspar, plagioclase and a small amount of pyrite, calcite, clay minerals, etc. Mercury intrusion capillary pressure analysis also showed that the samples generally had uniform particle configurations and pore distribution and there was no distinct correlation between the estimated porosity and air permeability. The allowable CO2 column heights based on the estimated pore-entry pressures and breakthrough pressures were found to be significantly higher than the thickness of the targeting CO2 injection layer. These results showed that the mudstone layers in the Yeongil group, Pohang basin, Korea have sufficient sealing capacity to suppress the leakage of CO2 injected during the demonstration-scale CO2 storage project. It should be noticed, however, that the applicability of results and analyses in this study is limited by the lack of available samples. For rigorous assessment of the sealing efficiency for geological CO2 storage operations, significant efforts on collection and multi-aspect evaluation for core samples over entire caprock formations should be accompanied.

Gas Hydrate Phase Equilibria of $CO_2+H_2$ Mixture in Silica Gel Pores for the Development of Pre-combustion Capture (연소 전 이산화탄소 회수기술을 위한 실리카겔 공극 내에서의 이산화탄소+수소 혼합가스 하이드레이트의 상평형)

  • Kang, Seong-Pil;Jang, Won-Ho;Jo, Wan-Keun
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.258-264
    • /
    • 2009
  • Thermodynamic measurements were performed to show the possibility of recovering $CO_2$ from fuel gas (the mixture of $CO_2$ and $H_2$) by forming gas hydrates with water where water was dispersed in the pores of silica gel particles having nominal 100 nm of pore diameter. The hydrate-phase equilibria for the ternary $CO_2+H_2$+water in pores were measured and $CO_2$ concentrations in vapor and hydrate phase were determined under the hydrate-vapor two phase region at constant 274.15 K. It was shown that the inhibition effect appeared due to silica gel pores, and the corresponding equilibrium dissociation pressures became higher than those of bulk water hydrates at a specific temperature. In addition, direct measurement of $CO_2$ content in the hydrate phase showed that the retrieved gas from the dissociation of hydrate contained more than 95 mol% of $CO_2$ when 42 mol% of $CO_2$ and balanced Hz mixture was applied. Compared with data obtained in case of bulk water hydrates, which showed just 83 mol% of $CO_2$ where 2-stage hydrate slurry reactor was intended to utilize this property, the hydrate formation in porous silica gel has enhanced the feasibility of $CO_2$ separation process. Hydrate formation as not for slurry but solid particle makes it possible to used fixed bed reactor, and can be a merit of well-understood technologies in the industrial field.

Carbonation Assessment of High-Strength Concrete Using Polypropylene Fiber after Fire Damage (폴리프로필렌 섬유를 혼입한 고강도 콘크리트의 화재피해 후 중성화 평가)

  • Byun, Yong-Hyun;Ryu, Dong-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.235-243
    • /
    • 2020
  • In recent years, the use of high-strength concrete has increased with increasing height and enlarging scale of the buildings However, it has been pointed out that the use of high-strength concrete is the most serious problem compared to ordinary concrete in terms of the spalling of concrete cross sections caused by fires. For this reason, fiber cocktail methods, which are made of polypropylene fibers, nylon fibers, etc., are mainly used to improve the fire resistance performance. However, the majority of research on high-strength concrete to which the fiber cocktail method was applied is mainly focused on the effect of reducing spalling, and few studies have investigated and analyzed the effect of micropores produced by melting PP fibers on the long-term durability of high-strength concrete after a fire. Therefore, in this study, the effect of micropores on the depth of carbonation was examined through carbonation tests and microstructure analysis, assuming high-strength concrete to which fiber-mixed construction method was applied, which caused fire damage.

Pratical Use of Capillarity in Nutrient Solution Trickle Supply (점적 양액공급에 있어서 모세관 현상의 이용)

  • 장전익;김우일
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.122-127
    • /
    • 1998
  • (1) 급액천의 규격별 양액공급량 $\bigcirc$ 합섬(비스코스+레이온) : 시간당 소(12.6ml), 중(21.2ml), 대(57.5ml)의 순으로 유입되었으며 중과 대의 급액천의 유입은 거의 같아 급액천의 규격간에 공급량은 비례하지 않았다. $\bigcirc$ 합섬(폴리에스텔) : 소(4.3ml), 중(20ml), 대(57.5ml)순으로 양액이 유출되었으며, $\bigcirc$ 합섬(인견) : 소(2.9ml), 중(23.7ml), 대(32.3ml)순으로 유입되었으나 소(급액천)의 유출량은 적어 급액천 재질로서 부적합하다고 생각되었으며, $\bigcirc$ 실(cotton) : 소(0.2ml), 중(3.0ml), 대(2.7ml)순으로 규격간에 유입은 차이가 없었으며 전체적으로 유출이 적어 급액천으로서는 부적합하였다. (2) 배지의 규격(종류)별 양액의 유입량 $\bigcirc$ 송이(Ф6.0mm~12.0mm이상) : 배지의 입자가 굵은 배지일수록 급액초기 1~2시간이 유입이 급격히 증가하였으나 시간이 경과할수록 일정한 량을 보였으며 유입량은 다른 배지에 비하여 많았고 급액천의 규격이 클수록 유입되는 량이 많았으나 시간이 경과함에 따라 감소하는 경향을 보였다. $\bigcirc$ 송이(Ф1~5mm) : 합섬A(비스코스+레이온)과 합섬B(폴리에스텔)에서는 시간당 15.0~50.1ml가 유입되었으나 합섬C(인견)과 실에서는 시간당 10ml이하로 토출량이 적었다. $\bigcirc$ 송이(Ф1~12mm) : 합섬A와 합섬B 급액천에서는 17.0~53.8ml가 유입되었으나 합섬C와 실에서는 시간당 평균 4.0~21.2ml가 흘러나와 배지의 공극이 일정하지 않아 시간당 통과하는 양이 일정하지 않았다고 생각되었다. $\bigcirc$ 펄라이트 : 합섬A(비스코스+레이온)급액천의 유입은 소(1$\times$60cm)에서 21.8ml, 중(2$\times$60cm) 33.5ml, 대(3$\times$60cm) 43.4ml가 통과되었고 합섬(폴리에스텔)에서는 19.0~30.7ml로서 급액천의 규격에 따라 통과되는 차이가 있었다. 배지가 규격화되어 있어 급액천의 규격별로 일정하게 유입되었으며 급액천의 재질이 유입에 영향을 미친 것으로 사료되었다. (2) 급액관과 베드상과의 높이에 따른 유출양 : 급액과 베드상과의 낙차가 클수록 유출이 증가함을 알수 있었으나 합섬C(인견)실험구에서는 낙차가 유출에 영향을 미치지 않았다. (4) 급액된 양액의 EC 및 pH조사 : 급액된 양액의 EC 및 pH에 전혀 변화가 없어 재배 적응에 문제가 없을것으로 사료되었다.

  • PDF

Effect of Phosphate-to-binder and Water-to-binder Ratio on Magnesia-potassium Phosphate Cement (마그네시아-인산칼륨 시멘트에 대한 인산염 비 및 물-결합재비의 영향)

  • Lee, Kyung-Ho;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.275-281
    • /
    • 2017
  • This study examined the effect of water-to-binder ratio (W/B) and phosphate-to-binder ratio (P/B) on the flow, setting time, compressive strength development, and pH variation of magnesium-potassium phosphate composites, MKPC mortars. Ten mortars mixtures were prepared with the W/B varying from 20% to 40% at each P/B of 0.3 or 0.5. The hydration products and microstructural pore distribution of the MKPC pastes were investigated using X-ray diffraction (XRD), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP). The initial flow and setting time of MKPC mortars tended to decrease with an increase of P/B, indicating that the final setting time was shortened by approximately 24% when P/B increased from 0.3 to 0.5. The slope of the early-strength development measured in the MKPC mortars was considerably higher than that of cement concrete specified in code provisions. For obtaining a relatively good 28-day strength (above 30 MPa) and a near neutral pH (below 9.0) in MKPC mortars, the P/B and W/B need to be selected as 0.5 and 30%, respectively. The strubite-K crystal increased with the increases of P/B and W/B, which leads to the decrease of the macro-capillary pores.

Resistance to Sulfate Attack of Concrete Containing LCD glass powder Using Industrial By-products (산업부산물을 활용한 LCD 유리 미분말 혼입 콘크리트의 황산염침식 저항성)

  • Kim, Seong-Kyum;Song, Jae-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.239-248
    • /
    • 2019
  • Purpose: This study aims to enhance the resistance against sulfate attack compared to ordinary Portland cement (OPC) concrete by using liquid crystal display (LCD) as binder. Method: The fundamental properties including compressive strength and porosity of concrete replaced by LCD up to 15% at increments of 5% and in turn, the weight, volume, and strength loss of LCD-mixed concrete was analyzed. Results: For the concrete substituted by 5% of LCD, it showed the highest compressive strength at 28 days of curing, and particular at immersion of $Na_2SO_4$ solution, it was achieved the lowest loss of weight, volume and strength due to an decreased porosity at capillaries. In contrast, there is no distinct difference of the sulfate attack resistance between LCD-mixed concretes under exposure of $MgSO_4$ solution, excepted for OPC concrete. Conclusion: In this study, comparison of resistance to sulfate attack between LCD-mixed concretes, and it would be proposed the possibility of LCD usage as binder through long-term verification with extended replacement ratio and identification of changes of hydrates in the cement matrix.