• Title/Summary/Keyword: 비등 곡선

Search Result 62, Processing Time 0.031 seconds

A Mechanistic Model for Forced Convective Transition Boiling of Subcooled Water in Vertical Tubes (수직관내 미포화수의 강제대류 천이비등에 대한 역학적 모델)

  • Lee, Kwang-Won;Baik, Se-Jun;Han, Sang-Good;Joo, Kyung-Oin;Yang, Jae-Young
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.503-517
    • /
    • 1995
  • A mechanistic model for forced convective transition boiling has been developed to predict transition boiling heat flux realistically. This model is based on a postulated multi­stage boiling process occurring during the passage time of an elongated vapor blanket specified at a critical heat flux condition. Between the departure from nucleate boiling (DNB) and the departure from film boiling (DFB) points, the boiling heat transfer is established through three boiling stages, namely, the macrolayer evaporation and dryout governed by nucleate boiling in a thin liquid film and the unstable film boiling. The total heat transfer rate during the transition boiling is the sum of the heat transfer rates after the DNB weighted by the time fractions of each stage, which are defined as the ratio of each stage duration to the vapor blanket passage time. The model predictions are compared with some available experimental transition boiling data. From these comparisons, it can be seen that the transition boiling heat fluxes including the maximum heat flux and the minimum film boiling heat flux are nil predicted at low qualities/high pressures near 10 bar.

  • PDF

A Study on the Real Quality and Void Fraction of Subcooled Refrigerant Flow (과냉 비등류의 실제건도와 보이드율에 관한 연구)

  • Kim, J.H.;Kim, C.S.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.36-43
    • /
    • 1993
  • Real quality and axial void fraction distribution of subcooled refrigerant flow is very important to predict the heat transfer rate and pressure drop in the design of refrigerating system. In the subcooled boiling region, the liquid bulk temperature is still below the corresponding saturation temperature. But beyond the net vapor generation point, bubble detachment is occured actively from the vapor layer formed on the wall. A reliable method to predict the vapor fraction from the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled R-113 flow is calculated in the range of 261-1239kg/$m^2$s mass velocity and 10-30K subcooling.

  • PDF

The effect of forced convection on boiling heat transfer from a horizontal tube (수평 원관의 비등 열전달에서 강제대류의 영향)

  • 이승홍;이억수;정은행
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.558-568
    • /
    • 1998
  • This paper presents the results of experiments involving external forced convection on boiling heat transfer from electrically heated horizontal tube to water in cross flow. In these experiments, all of the following primary variables were varied: heat flux, cross flow velocity, pressure and degree of subcooling. Local surface temperatures were measured at nine peripheral positions. Surface temperature distributions are classified into four groups as a function of heat flux. The characteristics of the boiling curve at different velocity, degree of subcooling and pressure are examined.

  • PDF

Non-isothermal Crystallization Behaviors of Ethylene-Tetrafluoroethylene Copolymer (에틸렌-테트라플르오르에틸렌 공중합체의 비등온 결정화 거동)

  • Lee, Jaehun;Kim, Hyokap;Kan, Ho-Jong
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.803-809
    • /
    • 2012
  • The non-isothermal crystallization behavior of ethylene-tetrafluoroethylene (ETFE) copolymer was investigated by DSC and imaging FTIR analysis. Modified non-isothermal Avrami analysis was applied to interpret the crystallization behavior of ETFE. It was found that the less linearity in ln[-ln(1-X(t))] vs. ln(t) plot was obtained in thermal analysis comparison with imaging FTIR due to relatively small crystallization enthalpy change in ETFE. It means that imaging FTIR measured by overall IR absorption intensity change due to the crystallization was found to be effective to understand the non-isothermal crystallization kinetics of ETFE. In addition, the optical transmittance of ETFE was studied. The crystallite developed by slow cooling caused the light scattering and resulted in the increase of haze and the lowering of transmittance up to 8%. From our results, it was confirmed that cooling rate is an important processing parameter for maintaining optical transmittance of ETFE as a replacement material for glass.

Shape Extraction Using Inward and Outward Curve Evolution (양방향 곡선 전개를 이용한 형태 추출)

  • 김하형;김성곤;김두영
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.225-228
    • /
    • 2000
  • 본 논문에서는 물체의 경계나 형태 추출을 위하여 레벨 세트 이론을 바탕으로 한 새로운 곡선 전개 방법을 제안한다. 특히 전처리 과정에서 잡음의 효과적 처리를 위하여 기존의 필터 방식들이 가지는 단점인 경계 부분의 blurring 현상을 줄이고 정확한 에지 위치를 보존할 수 있는 비등방성 확산필터(anisotropic diffusion filter)를 사용한다. 기존의 레벨 세트 방식이 수축이나 팽창 중 단지 한가지의 방식만 적용되어지는 반면, 제안한 방법은 물체의 경계 추출시 팽창과 수축이 동시에 가능하므로 특히 초기 곡선이 여러 물체에 걸쳐져 있는 경우에도 정확한 형태 추출이 가능하였다. 아울러 초기 곡선의 설정이 위치나 형태에 거의 제한을 받지 않기 때문에 추출을 원하는 영역이 아주 조금만 포함되어 있어도 정확한 형태 추출이 가능하였다.

  • PDF

Identification of Uncertainty in Fitting Rating Curve with Bayesian Regression (베이지안 회귀분석을 이용한 수위-유량 관계곡선의 불확실성 분석)

  • Kim, Sang-Ug;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.943-958
    • /
    • 2008
  • This study employs Bayesian regression analysis for fitting discharge rating curves. The parameter estimates using the Bayesian regression analysis were compared to ordinary least square method using the t-distribution. In these comparisons, the mean values from the t-distribution and the Bayesian regression are not significantly different. However, the difference between upper and lower limits are remarkably reduced with the Bayesian regression. Therefore, from the point of view of uncertainty analysis, the Bayesian regression is more attractive than the conventional method based on a t-distribution because the data size at the site of interest is typically insufficient to estimate the parameters in rating curve. The merits and demerits of the two types of estimation methods are analyzed through the statistical simulation considering heteroscedasticity. The validation of the Bayesian regression is also performed using real stage-discharge data which were observed at 5 gauges on the Anyangcheon basin. Because the true parameters at 5 gauges are unknown, the quantitative accuracy of the Bayesian regression can not be assessed. However, it can be suggested that the uncertainty in rating curves at 5 gauges be reduced by Bayesian regression.

Secure Scalar Multiplication with Simultaneous Inversion Algorithm in Hyperelliptic Curve Cryptosystem (초 타원 곡선 암호시스템에서 동시 역원 알고리즘을 가진 안전한 스칼라 곱셈)

  • Park, Taek-Jin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.318-326
    • /
    • 2011
  • Public key cryptosystem applications are very difficult in Ubiquitos environments due to computational complexity, memory and power constrains. HECC offers the same of levels of security with much shorter bit-lengths than RSA or ECC. Scalar multiplication is the core operation in HECC. T.Lange proposed inverse free scalar multiplication on genus 2 HECC. However, further coordinate must be access to SCA and need more storage space. This paper developed secure scalar multiplication algorithm with simultaneous inversion algorithm in HECC. To improve the over all performance and security, the proposed algorithm adopt the comparable technique of the simultaneous inversion algorithm. The proposed algorithm is resistant to DPA and SPA.

각종 담금제의 냉각성능에 관한 연구 II

  • 민수홍;구본권;김상열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.419-423
    • /
    • 1989
  • The laboratory quench method used in this study is based on plunging a silver cylinder heated to 800.deg. C in to mineral oil and vegetable at given temperature. Experimental apparatus and measuring method followed Korean Industrial Standard. Colling curves at the boundary of the cylinder measured by a silver-alumel thermocouple is recorded throughout the quenching period. Using the cooling curves, the coolingability of the quenching oils at various temperatures were compared and discussed.

A Study on the Automatic Classification between Contour Elements and Non-Contour Elements in a Contour Map Image (등고선 지도영상에서의 등고 성분과 비등고 성분의 자동 분리에 관한 연구)

  • 김경훈;김준식
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.7-16
    • /
    • 2002
  • En this paper, we propose the algorithm that has analyzed the map Information automatically to extract the contour lines and numbers, symbols from the map image. After converting the input image to binary one, thinned image is obtained by thinning algorithm. The contour elements in the thinned image are classified and the classified elements are analyzed to automatically classify the numbers from symbols. Finally, the broken parts are restored by reconstruction algorithm. The performance of proposed algorithm is verified through the simulation. The proposed one has good performance.

  • PDF

Improvement of Rating Curve Fitting Considering Variance Function with Pseudo-likelihood Estimation (의사우도추정법에 의한 분산함수를 고려한 수위-유량 관계 곡선 산정법 개선)

  • Lee, Woo-Seok;Kim, Sang-Ug;Chung, Eun-Sung;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.807-823
    • /
    • 2008
  • This paper presents a technique for estimating discharge rating curve parameters. In typical practical applications, the original non-linear rating curve is transformed into a simple linear regression model by log-transforming the measurement without examining the effect of log transformation. The model of pseudo-likelihood estimation is developed in this study to deal with heteroscedasticity of residuals in the original non-linear model. The parameters of rating curves and variance functions of errors are simultaneously estimated by the pseudo-likelihood estimation(P-LE) method. Simulated annealing, a global optimization technique, is adapted to minimize the log likelihood of the weighted residuals. The P-LE model was then applied to a hypothetical site where stage-discharge data were generated by incorporating various errors. Results of the P-LE model show reduced error values and narrower confidence intervals than those of the common log-transform linear least squares(LT-LR) model. Also, the limit of water levels for segmentation of discharge rating curve is estimated in the process of P-LE using the Heaviside function. Finally, model performance of the conventional log-transformed linear regression and the developed model, P-LE are computed and compared. After statistical simulation, the developed method is then applied to the real data sets from 5 gauge stations in the Geum River basin. It can be suggested that this developed strategy is applied to real sites to successfully determine weights taking into account error distributions from the observed discharge data.