• Title/Summary/Keyword: 비등

Search Result 1,222, Processing Time 0.03 seconds

Numerical Analysis of Natural Convection-Radiation Heat Transfer in an Enclosure Containing Absorbing, emitting and Linear Anisotropic Scattering Medium (흡수,방사 및 선형비등방 산란 매질을 포함하는 밀폐공간내의 자연대류- 복사열전달에 대한 수치해석)

  • 차상명;김종열;박희용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.952-964
    • /
    • 1992
  • The interaction of natural convection and radiation heat transfer in a two dimensional square enclosure containing absorbing, emitting and linear anisotropically scattering gray medium is numerically analyzed. P-1 and P-3 approximation is introduced to calculate radiation heat transfer. The effects of scattering albedo, wall emissivity, scattering anisotropy, and optical thickness on the characteristics of the flow and temperature field and heat transfer are investigated. Temperature and velocity profiles depend a great deal on the scattering albedo, and the importance of this effect increases with decrease in albelo. Planck number is another important parameter in radiation heat transfer. The increase in scattering albedo increases convection heat transfer and decreases radiation heat transfer at hot wall. However, the increase in scattering albedo decreases both convection and radiation heat transfer at cold wall. The increase in optical thickness decreases radiation heat transfer. The scattering anisotropy has important effects on the radiation heat transfer only. The highly forward scattering leads to an increase of radiation heat transfer whereas the highly backward scattering leads to an decrease of radiation heat transfer. The effect of scattering anisotropy decreases when reducing the wall emissivity.

Visualization of Flow Characteristics on Thermosyphon with Immiscible Binary Working Fluid (비 혼합 2유체 열사이폰의 유동 특성에 관한 가시적 연구)

  • Do, Sun Yub;Kang, Hawn Kook;Park, Seung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3022-3029
    • /
    • 2015
  • This study presents experiments to visualize the internal flow and heat transfer characteristics of thermosyphon with immiscible of water-FC40 adopted as binary working fluid. Three different regimes depending on the amount of heat flux applied to the thermosyphon were observed: natural convection, pulse boiling, and continuous boiling. Boiling incipience took place in water, which has lower vapor pressure than FC40. During natural convection water was vaporized in liquid pool while liquid film flows were formed. On the other hand, meanwhile bubbles were generated in the liquid pool during pulse and continuous boiling, the binary working fluid of water-FC40 was observed as the mixture throughout a whole range of the thermosyphon.

Urban Flood Modeling with Anisotropic Porous Shallow Water Model (비등방 다공성 2차원 천수모형을 적용한 도시홍수 모델링)

  • Kim, Byunghyun;Kim, Hyun Il;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.414-414
    • /
    • 2020
  • 고전 천수방정식을 적용한 2차원 도시홍수 모델링에서는 지형의 정확한 반영을 위해 고해상도 격자가 요구되며 이는 많은 계산시간과 노력을 필요로 한다. 최근에는 다공성 천수방정식을 적용한 도시홍수해석으로 많은 계산 노력이 요구되는 도시홍수모델링의 한계를 극복한 연구가 많이 이루어지지고 있다. 이러한 연구는 도시 홍수에서 흐름이 공간적으로 변화할 때 불균일 공극이 존재하므로 격자의 크기를 다르게 하여 이러한 불균일성을 해결하고자 하는 등방성 천수모형의 적용에서 시작되었다. 하지만, 등방성 공극을 고려한 도시홍수 해석모형은 대표요소체적(REV)보다 더 큰 격자의 적용을 해야 하는 제한성을 가진다. 반면, 비등방성 공극은 대표요소체적의 적용이 필요하지 않아 불균일 공극의 크기에 관계없이 이론상으로는 동일한 해상도의 격자가 사용가능하긴 하지만, 실제 도시홍수 해석에서 중요하면서도 도전적인 연구이다. 본 연구에서는 도시홍수의 효율적 계산을 위해 비등방성 공극을 고려한 적분형 다공성 천수방정식을 기반으로 하는 2차원 도시홍수 해석모형을 개발하였다. 모형의 개발을 위해, 적용 격자내에서 도시지역의 건물이 차지하는 길이 및 면적을 산정하고 그 값을 2차원 천수방정식에 적용 가능하도록 체적공극(𝜙j)와 면적공극(𝜓k)을 2차원 고전 천수방정식에 추가하였다. 개발모형은 고전 천수방정식, 등방성 공극 고려(미분형 다공성) 천수방정식 및 비등방성 공극 고려(적분형 다공성) 천수방정식의 적용이 가능하여, 각 모형에 적합한 2차원 격자 생성, 각 모형의 매개변수를 보정 그리고 정확성, 효율성, 적용성이 비교 가능하다. 각 모형의 정확성과 효율성 비교를 위해 3가지의 오차 비교 (구조적 오차, 격자크기 오차, 공극 모형 오차), 계산시간 비교, 공간 변동성 검증을 위한 수심 종단형상 비교하였다.

  • PDF

탄소나노튜브 나노유체의 파울링 현상에 따른 열적 특성에 대한 연구

  • Mun, Ji-Eun;Kim, Yeong-Hun;Kim, Nam-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.383.1-383.1
    • /
    • 2016
  • 열전달 시스템에서 임계 열유속 발생 시 시스템의 물리적 손상을 야기하기 때문에 비등 열전달에서 임계 열유속은 열전달 시스템의 한계 또는 안전성을 나타낸다. 따라서 열전달 시스템의 안정성을 위해서는 임계 열유속 향상이 필수적이다. 최근에는 나노유체를 열전달 시스템에 적용할 경우 임계 열유속이 증가한다고 보고되었다. 하지만 나노유체는 원전 및 각종 열전달 시스템에 적용 시 나노입자가 열전달 표면에 침착되는 파울링 현상을 발생시킬 수 있으며, 이 때문에 시스템의 열효율이 크게 감소할 수 있다. 따라서 본 연구에서는 열전달 시스템에 나노유체를 적용했을 때, 나노유체의 침착현상이 시스템에 미치는 영향을 분석하였다. 그 결과 유속과 코팅시간이 증가할수록 산화처리된 다중벽 탄소나노튜브 나노유체의 임계 열유속이 크게 증가하고 있음을 확인할 수 있다. 하지만 나노입자 침착정도와 유속이 증가할수록 비등 열전달 표면과 유체의 포화온도의 차이인 과열도가 상당히 크게 증가함을 알 수 있었으며, 열전달 계수는 순수 물의 0 m/s의 비등 열전달 계수와 비교하면 감소하는 것을 확인하였다.

  • PDF

A Study on the Characteristics of Frequency Response Functions for Rotor System with Anisotropic Stator and Asymmetric Rotor (비등방 정지부 및 비대칭 회전부를 갖는 회전체의 주파수응답함수 특성에 관한 연구)

  • Han, Dong-Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.42-50
    • /
    • 2005
  • Based upon the derived analytical model and equation of motion for the general rotor system with anisotropic stator and asymmetric rotor treated as a periodically time-varying system, the series of equations are structured by associating with the time modulated coefficients. The frequency response functions (FRFs) expressed by physical parameters are derived in such a convenient way from the direct inverse matrices of the Fourier transformation of those series of equations, from which the characteristics are analyzed and the properties are suggested.

Stydy of Pool Boiling under Steady State using Ultrasonic Measurement (초음파 측정법을 이용한 정상상태의 푸울비등 연구)

  • 장길홍
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.35-40
    • /
    • 1992
  • A recently developed new technique for measuring the fraction of wetted area has applied to pool boiling of water. The basis of the new applied technique of ultrasonic makes use of the reflection of ultrasonic from the vapour surface to measure the fraction of wetted area values. The results are the measured fraction of wetted area values in nucleate and transition boiling and the pool boiling curve for water under steady state conditions. The measurement of this paper shows a fraction of wetted areaf around 0.98 at the critical heat flux for water.

  • PDF

A Study on Saturated Boiling Heat Transfer in Upward Rectangular Impinging Water Jet System (연직상향(鉛直上向) 사각충돌수분류(四角衝突水噴流)의 포화비등 열전달에 관한 연구)

  • Lee, J.S.;Ohm, K.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.395-403
    • /
    • 1991
  • The purpose of this investigation was to characterize nucleate boiling and burn-out heat flux for rectangular free jet with saturated water impinging perpendicularly and upward against a flat uniform heat flux surface. Heat flux measured for Reynolds number based on rectangular nozzle width and for aspect ratio. The result of nucleate boiling heat transfer was presented nondimensional experimental equation including Nusselt, Boiling, Subcooling, Reynolds and Weber number. The effect of aspect ratio of heated surface in the burn-out heat flux had not appeared distinctly. But for the same aspect ratio, burn-out heat flux increased linearly with increment of nozzle exit velocity.

  • PDF

Mathematical Modeling of Two-Dimensional Diffraction Analysis in Anisotropic Media (비등방성 매질에서의 2차원적 회절현상의 수학적 모델링)

  • Chung, Yeong-Jee;Jin,
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.86-97
    • /
    • 1988
  • 본 논문에서는 비등방성 매질에서의 2차원적 회절현상을 수학적으로 모델링하였다. 비등방성 매질의 2차 포물선 근사법과 프레즈넬 근사법을 적용하기 위하여 전파방향에 따른 표면파 속도의 역수를 포물선으로 가정하였다. 128${\circ}$ Rotated $LiNbO_{3}$ 기판을 사용한 SAW IF Bandpass Filter에서의 회절현상을 모의 설계하여 그 결과를 회절현상이 없는 이상적인 경우와 비교하였다. 또한 전산화 모의 설계 결과와 실제로 제작된 SAW Filter 특성결과를 비교하여 $LiNbO_{3}$ 기판을 사용한 SAW Filter에서도 프레즈넬 근사법이 대체적으로 일치하는 것을 알 수 있었다.

  • PDF

R-134a Flow Boiling on a Plain Tube Bundle (평활관군의 R-134a 흐름비등에 관한 연구)

  • 김종원;김정오;김내현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from $8\;kg/m^2s$ to $26\;kg/m^2s$ and heat flux from $10\;kW/m^2s$ to $40\;kW/m^2s$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which satisfactorily () predicted the data. Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

  • PDF

A Study on the Real Quality and Void Fraction of Subcooled Refrigerant Flow (과냉 비등류의 실제건도와 보이드율에 관한 연구)

  • Kim, J.H.;Kim, C.S.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.36-43
    • /
    • 1993
  • Real quality and axial void fraction distribution of subcooled refrigerant flow is very important to predict the heat transfer rate and pressure drop in the design of refrigerating system. In the subcooled boiling region, the liquid bulk temperature is still below the corresponding saturation temperature. But beyond the net vapor generation point, bubble detachment is occured actively from the vapor layer formed on the wall. A reliable method to predict the vapor fraction from the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled R-113 flow is calculated in the range of 261-1239kg/$m^2$s mass velocity and 10-30K subcooling.

  • PDF