• Title/Summary/Keyword: 비냉각

Search Result 892, Processing Time 0.025 seconds

Gamma-Ray Spectrometric Determination of Burnup Distribution and Cooling Time of Spent PWR Fuel Assemblies (감마선 분광분석에 의한 조사후 핵연료 집합체(PWR)의 연소분포 및 냉각시간 결정)

  • Young-Gil Lee;Jae-Shik Jun
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 1985
  • Non-destructive gamma-ray spectrometry was carried out on the spent PWR fuel assemblies at the spent fuel pool of reactor-site. Attention was focused on the determination of burnup distribution and cooling time. For the measurement of burnup distribution, the concentration ratio of $^{134}$ Cs$^{137}$ Cs was used and the results showed these ratios varied with the positions of assemblies in the core during their irradiation. For the measurement of cooling time, $^{144}$ Ce$^{137}$ Cs was used and the results were agreed considerably well with the operator declared cooling time.

  • PDF

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

Heat Transfer Enhancement Using Ceramic-Oil Nanofluids for an Airplane Cooling System (세라믹-오일 나노유체를 이용한 항공기 냉각매체의 열전달특성 향상)

  • Jeong, Il-Yeop;Jeong, Mi-Hui;Choe, Cheol;O, Je-Myeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.46-46
    • /
    • 2008
  • 스텔스 기능을 가진 군사용 항공기는 레이다 망의 추적을 피하기 위해 일반 냉각수 대신에 절연유를 냉각매체로 사용한다. 그러나 절연유는 물에 비하여 열전달특성이 매우 낮기 때문에 항공기 전기전자 기기/부품 발열부를 효과적으로 냉각시키지 못하는 한계성을 가지고 있다. 따라서 본 연구에서는 나노유체(Nanofluid) 개념을 이용하여 절연유에 알루미나 및 질화알루미늄 나노분말을 미랑 분산시킨 나노절연유를 제조하고 이것의 열전달특성을 순수 절연유의 그것과 비교 평가함으로써, 냉각특성이 크게 개선된 새로운 냉매로서의 적용 가능성을 확인하고자 하였다. 다만 나노절연유를 제조함에 있어서 가장 큰 장애물은 오일에 대한 분산성 확보에 있기 때문에, 비드밀 및 초음파를 이용한 나노분말 응집체의 습식분산 및 분산제를 이용한 친유성 표면개질을 동시에 수행함으로써 장시간 안정된 분산성을 확보하도록 노력하였다. 나노유체의 열전도도 및 대류열전달계수는 비정상열선법을 이용하여 측정하였으며, 유체 속의 분말 분산 상태는 원심력을 이용한 분산안정성 평가장치 및 cryo FE-SEM을 이용하여 확인하였다. 또한 분말 형상이 대류열전달에 미치는 영향을 조사하기 위하여 알루미나 나노분말은 구상과 침상의 분말을 모두 사용하였고, 질화알루미늄 외에 다이아몬드 나노절연유도 함께 제조, 평가함으로써 냉각 및 절연특성, 그리고 물리화학적 안정성이 우수하고 실적용 가능성이 가장 높은 재료를 도출하고자 하였다.

  • PDF

Influence of the Vertical Flame holder on Heat Transfer Characteristics of Ramjet Combustor (세로축 화염안정기 형상이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Yang, Kang-Mo;Lee, Keon-Woo;Song, Ji-Woon;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.305-309
    • /
    • 2008
  • This experimental study has been conducted to investigate the installation of the vertical flame holder shape in ramjet combustor, which affects on the film cooling effectiveness. All slot position, the film cooling effectiveness decreases because of the shear layer and high turbulence intensity between separated flows and coolant flows. When the flame holder is installed, film cooling effectiveness decreases abruptly on the beginning of the slot exit region due to the mixing effect. As the blowing rate increases, the film cooling effectiveness is increased for all cases due to the augmented momentum of injected coolant from the slot.

  • PDF

Improvement of Cooling Effects of Pylon Injector for Scramjet Combustor (스크램제트 연소기용 파일런 분사기 냉각성능 개선 연구)

  • Lee, Sang-Hyeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.5
    • /
    • pp.10-18
    • /
    • 2011
  • A new film cooling method to protect the pylon injector from aerodynamic heating for a scramjet combustor is proposed and verified with numerical methods. The conditions for the Mach 8 flight at an altitude of 35km are considered. Air is considered as a coolant. Three-dimensional Navier-Stokes equations with $k-{\omega}$ SST turbulence model are used. A downward injection of coolant from the top of the pylon gives higher cooling effects with less mass flow rate of coolant than the upward coolant injection from bottom of the pylon. Also, the downward injection shows little flow separation due to the favorable pressure gradient and does not disturb the flowfields near pylon injector, which results in reduction of pressure losses.

Development Thermal Design Program to Predict Film Cooling Performance in Liquid Rocket Engine (로켓엔진의 막냉각 성능 예측을 위한 열설계 프로그램 개발)

  • Cho Won-Kook;Moon Yoon-Wan;Seol Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.161-164
    • /
    • 2006
  • A design program has been developed to predict film cooling performance in a liquid rocket engine combustion chamber. A thermal protecting effect of low mixture ratio gas has been analysed by CFD. A one-dimensional film cooling model based on the CFD results has been implemented in the previously developed design program of regenerative cooling. The predicted heat flux at the nozzle throat ranges from -16% to +28% when it is compared to the published measured data. The throat heat flux reduces by 36% when film cooling of 10% of fuel mass flow rate is applied.

  • PDF

A Thermal Analysis of Liquid Rocket Combustors using a Modelling of Film Cooling Performance (막냉각 모형을 이용한 액체로켓엔진 연소기의 열해석)

  • Kim, Hong-Jip;Cho, Won-Kook;Moon, Yoon-Wan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2006
  • A design program has been developed to predict film cooling performance of a liquid rocket engine. A thermal protecting effect of low mixture ratio gas layer has been analysed by CFD. A one-dimensional film cooling model based on the CFD results has been implemented to the previously developed design program of regenerative cooling. Satisfactory agreement has been achieved by comparing the predicted maximum heat flux at the throat of a subscale chamber and the average measured value, and the predicted nozzle average heat flux and the measured value for a full scale chamber with film cooling. It is ascertained that the film cooling is effective to reduce the throat heat flux in rocket engine chamber.

Effect of Cooling-rate Dependence on the Magnitude of Thermoremanent Magnetization (냉각률이 자화에 미치는 영향)

  • Yu, Yong-Jae
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2010.10a
    • /
    • pp.43-45
    • /
    • 2010
  • Acquisition of thermoremanent magnetization follows a Boltzman statistics, as such long reaction time in a slowly cooled environment allows more chance to align individual magnetic particles parallel to the external magnetic field. Hence it has been proposed that the slowly cooled rocks often acquire stronger magnetization than the rapidly cooled ones. Such a proposition has been experimentally validated to be true for the fine-grained magnetite- or titanomagnetite bearing basaltic rocks collected from the mid-ocean ridges. However, the effect of cooling-rate on the remanence intensity appears to be insignificant for nominal grain ranges.

  • PDF

Pain reducing effect of vapocoolant spray during injection and heelstick procedure in neonates (신생아에서 근육 주사 및 발뒤꿈치 천자 시 냉각 분사의 통증감소효과: 냉각 분사와 30% 경구 포도당액의 비교)

  • Choi, Eun Kyong;Jung, Ji Mi;Sin, Jong Beom
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.5
    • /
    • pp.481-486
    • /
    • 2008
  • Purpose : The aims of this study were to test the efficacy of vapocoolant spray to decrease the symptoms associated with pain in newborns undergoing heel stick and intramuscular injection and compare the pain relief effect of oral glucose. Methods : Randomized, controlled study including sixty newborns undergoing heel stick and intramuscular injection. Group 1 was heelsticked, Group 2 was intramuscular injected, Group A did not recieve any treatment, Group B recieved 30% glucose solution orally, Group C was applied vapocoolant spray symptoms and signs associated with pain at heel stick and intramuscular injection were measured with the premature Infant Pain Profile (PIPP) scale. Results : There was no significant difference in the PIPP score between intramuscular injected group control and heel stick group control (P=0.07). The mean PIPP score of Group 1A (control) $10.6{\pm}2.4$, Group 1B $5.5{\pm}2.0$, Group 1C $5.2{\pm}1.8$. The mean PIPP score 1B and 1C were significantly lower than control (1B P<0.001, 1C P<0.001). The mean PIPP score of Group 2A (control) $12.5{\pm}1.4$, Group 2B $7.0{\pm}1.7$, Group 2C $6.4{\pm}1.6$. The mean PIPP score 2B and 2C were significantly lower than control (2B P<0.001, 2C P<0.001). Conclusion : The antinociceptive effect of vapocoolant sparay is as effective as 30% oral glucose solution for pain control. So this study support the use of vapocoolant spray for reducing pain during painful procedure in the neonatal intensive care units.

Annealing Effects on VOx Thin Film Deposited by DC Magnetron Sputtering Method

  • Park, Il-Mong;Han, Myeong-Su;Han, Seok-Man;Go, Hang-Ju;Kim, Hyo-Jin;Sin, Jae-Cheol;O, Tae-Seung;Kim, Dong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.223-223
    • /
    • 2011
  • 적외선 감지기로 사용되는 microbolometer 소자재료로 VOx 또는 비정질 Si이 가장 많이 사용된다. 그 중에서 VOx 물질은 온도저항계수 즉, TCR이 높고 감지도가 우수하기 때문에 비냉각 적외선 검출기에 많이 응용된다. Microbolometer 검출기는 그 응답도는 micromachining 공정에 의해 좌우되는 열 고립구조에 의해 좌우된다. 특히 TCR 값이 크고, 열시상수 값이 작을수록 양질의 감지도를 얻을 수 있으므로 재료의 선택 및 공정이 매우 중요하다. 따라서 본 연구에서는 비냉각 적외선 감지소자로 사용되는 VOx 박막을 DC Sputtering을 사용하여 증착하였으며, 그 특성을 조사하였다. MEMS 공정에 의한 센서의 제작은 적외선을 흡수하여 저항변화를 읽어내어 판독하는 Readout IC(ROIC) 위에 행해진다. Monolithic 공정에 의해 이러한 ROIC 위에서 공정이 동시에 행해지므로 공정온도는 매우 중요한 요소로 작용한다. 따라서 증착된 VOx 박막의 열처리 효과를 연구하였다. 열처리 온도는 $250^{\circ}{\sim}420^{\circ}C$, 열처리 시간은 20~80 min 까지 변화시켰다. 갓 증착된 VOx 박막의 저항은 약 200 $k{\Omega}$이였으며, TCR은 -1.5%/$^{\circ}C$로 나타났다. 열처리 온도가 증가함에 따라 TCR 값은 증가하였으며, 열처리 시간이 증가할수록 역시 TCR 값이 증가하는 경향을 보였다. 열처리 온도 320$^{\circ}C$, 열처리 시간 40 min에서 TCR 값은 약 -2%/$^{\circ}C$의 값을 얻을 수 있었다. 이러한 성능의 VOx 박막을 이용하여 비냉각형 microbolometer 검출소자를 열변형없이 공정을 수행할 수 있을 것으로 기대한다.

  • PDF