• Title/Summary/Keyword: 블로워 모터

Search Result 9, Processing Time 0.024 seconds

Development of diagnosis index for tick/click and tone noise of blower motor using vibration signals (진동 신호를 이용한 블로워 모터 틱/클릭과 톤 소음의 진단 지수 개발)

  • Lee, Songjune;Cheong, Cheolung;Lee, In-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.363-369
    • /
    • 2019
  • Various studies have been conducted for the diagnosis of noise condition of complex rotary machines. In this study, diagnosis index using vibration signal is developed for the efficient and objective assessment of noise condition of a blower motor. The noise most commonly caused by the abnormal blower motor are Tick/Click noise and Tone noise. According to cause and noise characteristics, time-frequency analysis is used to diagnose Tick/Click noise, and smoothing in frequency domain is used to diagnose tone noise condition. The noise condition of the blower motors were diagnosed using the developed index and these results are compared with the diagnostic results by the experts. As a result, the agreement rate was about 95 %.

A Study of 50W High Speed BLDC Motor for Air Blower Drive (에어 블로워 구동용 50W급 고속 BLDC 모터에 관한 연구)

  • Baek, Chan-Wook;Seo, Jung-Moo;Yoo, Ji-Yoon;Jung, In-Soung
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.110-112
    • /
    • 2006
  • 본 연구는 소형, 고효율 3kW급 고분자 전해질 연료공급 모듈용 에어블로워 개발에 있어 필수요소인 BLDC형 블로워 모터에 관한 것이다. 에어블로워의 목표출력(50W)에 최적화된 BLDC모터를 설계하기위하여 등가자기회로법과 유한요소법을 이용하였고, 모터를 제작하여 해석결과와 비교 검증하였다.

  • PDF

DC 블로워 모터의 이상소음 및 진동 진단 시스템 개발

  • 김정욱;김성렬;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.280-280
    • /
    • 2004
  • 기계의 소음 및 진동은 환경요인과 함께 기계의 정밀도 향상 및 고장진단과 관련하여 가장 중요한 분야중 하나이다. 특히 기계의 구동원으로 가장 많이 사용되고 모터는 기계설비이면서도 전기적인 현상으로 작동하기 때문에 설비보전의 사각지대로 나타나고 있다. 또한, 진동으로 모터의 전기적인 결함을 분석하기에는 미흡한 부분이 나타나기 때문에 모터 전용분석 기법을 사용하여 전동기의 전기적 결함을 분석하면 보다 정확한 진단이 가능하다. 현재 일부 생산 현장에서는 모터를 진단하기 위해 진동, 온도, 전류 등의 측정기법 들을 이용하여 분석하고 있다.(중략)

  • PDF

Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation (우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Ahn, Sungmin;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.833-839
    • /
    • 2013
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in a harsh space environment which is represented by extremely cold temperatures and vacuum conditions. A thermal vacuum chamber which consists of a vacuum vessel, a pumping system, and a thermal control system are used to perform thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the closed loop thermal control system for thermal vacuum chambers. This paper describes the fan design of the cryogenic blower, the design of the thermal protection interface between the driving part and the fluid part, which were verified by thermal and structural analyses. The performance of the cryogenic blower is confirmed by similarity test on the test bench.

Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber (열진공 챔버용 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.11
    • /
    • pp.1008-1015
    • /
    • 2015
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in extremely cold/hot temperatures and vacuum conditions. A thermal vacuum chamber used to perform the thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the gaseous nitrogen (GN2) closed loop thermal control system for thermal vacuum chambers. A final goal of this research is development of cryogenic blower. Design requirements of a blower are 150 CFM flow rate, 0.5 bara pressure difference, hot and cold temperatures. This paper describes the performance analysis of impeller by 1D, CFD commercial software, the design of the thermal protection interface between the driving part and the fluid part. The performance of the cryogenic blower is confirmed by test at the standard air condition and is verified by on the thermal vacuum chamber at the real operating condition.

A Study on the Worst Stress Condition Test Evaluation of Blowers for Small Stationary Fuel Cell System (소용량 건물용 연료전지시스템 블로워의 가혹조건 평가에 관한 연구)

  • Kim, Kangsoo;Lee, Deokkwon;Lee, Jungwoon;Kim, Eunjung;Kim, Inchan;Kim, Younggyu;Shin, Hunyong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.34-40
    • /
    • 2012
  • The fuel cell is one of the renewable energy sources. And it is a new source of energy that can be applied to various fuels and continuously supported by the excellent city-gas infrastructure. It is important to improve performances and reliabilities, and reduce the cost of fuel cell systems for commercialization. And, some safety performances of blower domestically produced are evaluated and some improvements are researched to save the cost of fuel cell systems. In this paper, the performance and worst stress condition of blowers are evaluated in operating environment similar to the fuel cell systems. Actually, the correlation of flow, leakage and thermal behavior are evaluated in the worst stress condition at $70^{\circ}C$ and, some major factors of blower degradation such as a motor deterioration, material and structures of the outlet are examined.

Experimental verification of inverter's optimal controller for driving 150kW SPMSM of EGR blower of Green-ships (친환경 선박 EGR 블로워용 150kW SPMSM 구동 인버터 최적제어기의 실험적 검증)

  • Sehwan, Kim;Yeonwoo, Kim;Minjae, Kim;Uihyung, Yi;Sungwon, Lee
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.596-601
    • /
    • 2022
  • The application of the EGR system is increasing according to the recent trend of conversion to green-ships. EGR blower, one of the core parts of the EGR, consists of aerodynamic system and e-motor and inverter and etc. For the e-motor, a permanent magnet type synchronous motor with high energy density and excellent efficiency is applied recently. Small and medium-sized enterprises trying to develop the e-motors, however, for marine inverters mostly developed by global advanced companies due to the rigid classification certification and technical difficulties. One of disadvantage of universal inverters is that when optimal control fails, it is difficult to find the cause from user's point of view. Therefore, in this study, optimal controllers(Current vector contol and Tracking observer) for SPMSM for EGR blower was designed and verified to analyze the causes of failure of optimal control of universal inverter.

Durability Study of Blower Motor Noise (블로워 모터 소음의 내구성 고찰)

  • Lee, Myung-Han;Ih, Kang-Duck;Hwang, Dong-Woo;Lee, Hyeon-Heui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1115-1119
    • /
    • 2007
  • As in many of the vehicle NVH issues, blower motor noise has been improved over the years through intensive R&D and production process improvement. Durability of motors, however, still has room for improvement according to customer surveys such as VDS. To investigate the noise issues of blower motors in view of durability, current production motors along with major competitor motors are tested. The noise after accelerated durability test shows that production motors are competitive in noise level with similar noise performance compared to initial measurement. The test result also provided guidelines to the durability development process.

  • PDF

Commercial Development of a High Pressure Turbo Blower "Greenpressor" (고압 터보 Blower "Greenpressor" 개발)

  • Choi, Moon;Petrosyants, Vartan;Zakharova, Natalia
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.323-323
    • /
    • 2003
  • Many recent development activities suggest the possibility of a high-speed turbo(centrifugal) compressor or blower for the industrial application of compressed air supplying system when used with the most advanced high-speed motor, inverter technology, and advanced bearing for high rotational speed. The problems to be overcome are of reliability, the application of mass production methods, cost effective manufacture and competitive running costs. This presentation is not focused on a specific technology advances but on an overall review of our recent experiences while we have developed the high pressure turbo blower for the commercial purpose.

  • PDF