• Title/Summary/Keyword: 붕괴성능평가

Search Result 147, Processing Time 0.023 seconds

Analytical Study on the Fire Resistance of Internally Confined Hollow CFT Column (내부 구속 중공 CFT 기둥의 내화 성능에 대한 해석 연구)

  • Won, Deok Hee;Han, Taek Hee;Park, Jong Sup;Kim, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.461-470
    • /
    • 2009
  • A column resisting axial load and seismic load is one of the main members in a structural system. The heated column by event of a fire can lose its strength and it may damage its structural system or cause the collapse of the entire structural system. In this study, the fire resistance capacity of internally confined hollow concrete filled tube (ICH CFT) column was investigated. In an ICH CFT column, the yield strength of the external tube is important as a concrete filled tube (CFT) column because the external tube confines the filled concrete and the strength of the column depends on the confined effect. A study was performed by finite element analyses considering the confined effect and material nonlinearity as the temperature changes by the fire. The hollow ratio, the thickness of the external tube, and the strength of concrete were selected as the parameters for the analyses. The analyses were performed by using a commercial FEA program (ABAQUS) and nonlinear concrete model program. The analysis results showed that the hollow ratio and the strength of concrete mainly affect the fire resisting capacity of an ICH CFT column.

Survey of Building Structural Elements located at Underground for Improvement of Fire Resistant Performance (건축물 지하 구조부재의 내화성능 개선에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.76-84
    • /
    • 2008
  • Researches on fire resistant performance of primary structural elements such as columns and beams located at above the ground have actively been doing than those located at the below the ground from many researchers. But the structural elements such as columns at underground is very important in aspects of not only structural performance but also fire environment. The columns at the basement carry all the structural loads from the above and that means very critical in fire circumstances than that located at above the grounds. To evaluate the fire resistance performance of primary structural elements located at below the ground we conducted several sorts of surveys that contained fire regulations from several countries and structural types, materials and status of passive fire protection methods.

Seismic Performance Evaluation of Piloti-type low-rise RC apartment buildings using Nonlinear Static Analysis (비선형 정적해석을 이용한 필로티형 저층 RC 집합주택의 내진성능평가)

  • Lee, Jeong-Jae;Lee, Han-Seon;Kim, Hee-Cheul;Lee, Young-Hak;Lee, Ki-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.237-240
    • /
    • 2008
  • The objective of this study is to evaluate the seismic performance of the low-rise RC apartment buildings having piloties at ground level by using nonlinear static analysis with regards to the maximum considered and design earthquakes in Korea. To do this, the target displacement at roof was estimated according to FEMA356 (or ASCE/SEI-41), and the deformations of the critical members were compared with the failure criteria of Life Safety(LS) and Collapse Prevention(CP) given in FEMA356. The conclusions are as follows: (1) columns satisfy criteria of LS and CP, but (2) the shear wall in the longitudinal direction failed to satisfy those of both LS and CP while those in the transverse direction satisfy that of LS, but failed that of CP.

  • PDF

A Study for Structural Stabilities of Beams Built with TMC Fire Resistant Steels by Analytical Method at High Temperatures (해석적 방법에 의한 TMC 건축용 내화강재 적용 보부재의 고온 내력평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.60-66
    • /
    • 2017
  • Steel framed building can be destroyed due to deteriation of structural stabilities in a fire. This leads a TMC Fire Resistant Steels and this study analyzed the structural stabilities such as a deflection and a reduction of maximum load capacity for the structural beams built with a TMC Fire Resistant Steel. In this study the structural stabilities were evaluated using a mechanical properties in high temperatures not only a heat transfer theory but a heat stress anlaysis with a statistically determinated beam and a statistially indeternated one. The results showed that a TMC Fire Resistant Steels demonstrated a little lower those of Fire Resistant Steels.

Development of Performance Based Resistance Capacity Evaluation Method for RC Compression Member under Vehicle Impact Load (차량 충돌하중을 받는 RC 압축부재의 성능기반형 저항성능 평가방법 개발)

  • Kim, Jang-Ho Jay;Yi, Na-Hyun;Phan, Duc-Hung;Kim, Sung-Bae;Lee, Kang-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.535-546
    • /
    • 2010
  • Recently, the probability of collision accident between vehicles or vessels and infrastructures are increasing at alarming rate. Particularly, collision impact load can be detrimental to sub-structures such as piers and columns. The damaged pier from an impact load of a vehicle or a vessel can lead to member damages, which make the member more vulnerable to impact load due to other accidents which. In extreme case, may cause structural collapse. Therefore, in this study, the vehicle impact load on concrete compression member was considered to assess the quantitative design resistance capacity to improve, the existing design method and to setup the new damage assessment method. The case study was carried out using the LS-DYNA, an explicit finite element analysis program. The parameters for the case study were cross-section variation of pier, impact load angle, permanent axial load and axial load ratio, concrete strength, longitudinal and lateral rebar ratios, and slenderness ratio. Using the analysis results, the performance based resistance capacity evaluation method for impact load using satisfaction curve was developed using Bayesian probabilistic method, which can be applied to reinforced concrete column design for impact loads.

Assessment of Lifeline Construction Technology for Buried Alive in Building Collapse (도심지 붕괴사고에 따른 매몰지역 생명선 시공기술 평가)

  • Ryu, Byung-Hyun;Kang, Jae-Mo;Lee, Jangguen;Kim, Young-Sam;Joo, Rak-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.9
    • /
    • pp.47-52
    • /
    • 2016
  • Unusual extreme weather events, which exceed a safe design capacity of the infrastructure, increase the frequency of natural disasters and has also been enlarged damage scale. Aging buildings and rapid urban progress act as weighting factors for the new composite disasters. Technological advances support detecting pre-disaster risk, real-time data analysis, and rapid response to the disaster site, but it is insufficient that emergency relief for buried alive must take advantage of the proven technologies through field tests. This study aims to evaluate directional drilling performance through underground soils and the reinforced concrete structure for primary lifeline installation in order to quickly provide relief supplies for buried alive when urban structures collapse.

Estimation Method of Infiltration Capacity for Assessment of Drainage Capacity I (배수성능 평가를 위한 침투능 산정기법에 관한 연구 I)

  • Jeong, Jisu;Shim, Jeonghoon;Hwang, Youngcheol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.12
    • /
    • pp.49-55
    • /
    • 2019
  • Slope failure analysis entails proper understanding of various factors as well as the characteristics of ground conditions, which are difficult to achieve due to technological limits. Despite a number of past studies to clarify possible factors triggering slope failures, the impact of rainfall characteristics and infiltration rate, which are the key to estimation of slope stability in wet condition, on slope failures still remains unclear. This study has estimated permeability against various unit weights of soil based on constant head permeability tests using Jumunjin standard silica sand. One dimensional infiltration tests were conducted to estimate the infiltration capacity and the amount of infiltration taking into account the permeability and rainfall intensity. The applicability of existing empirical equations for the estimation of infiltration to granular soils was verified on the basis of the test results.

An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting (긴급시공이 가능한 FRP 복합재료 보강재로 보강된 기둥의 내진성능평가)

  • Kim, Jin-Sup;Seo, Hyun-Su;Lim, Jeong-Hee;Kwon, Min-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. In the past, cross-sectional extension method, a steel plate reinforcing method and fiver-reinforced method are applied to Seismic Rehabilitation Technique mainly. However, the reinforcement methods have drawbacks that induce physical damage to structures, large space, long duration time. So, in this study, performance evaluation of previously developed FRP seismic reinforcement which do not induce physical damage and short duration time was enforced. The specimens were constructed with 80% downscale. FRP seismic reinforcement are manufactured of glass fiber or aluminum plate with holes and glass fiber. From the experiment results, seismic performance of specimens which reinforced with FRP seismic reinforcement were increased.

Evaluation and Analysis on the Effects of Flood Damage Mitigation according to Installation on Deep Underground Rainwater Tunnel (대규모 터널형 빗물저류배수시설 설치에 따른 침수피해저감 효과 평가 및 분석)

  • Myung Hoon Lee;Jun Han Bae;Jun Bae Hong;Soo Jin Moon;Ji Hyeok Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.365-365
    • /
    • 2023
  • 우리나라는 지리, 지형 및 기상특성으로 인해 집중호우와 태풍 등으로 자연재해 피해를 입고 있으며, 재해예방사업의 일환으로 1998년부터 자연재해위험개선지구 정비사업을 통해 자연재해로부터 침수, 유실, 붕괴위험 등 피해예방을 위해 노력하고 있다. 서울특별시는 도시화로 인한 우수침투 가능지역 감소와 유역경사 부족에 따른 충분한 관거 경사확보의 어려움으로 저지대에 노면수가 집중되면서 대규모 침수피해(2010. 09, 2011. 07)가 발생되었으며, 신월·신정지구 및 화곡2지구가 자연재해위험개선지구로 선정(2011. 04), 침수방지를 위한 대책으로 국내 최초의 대규모 터널형 빗물저류배수시설(신월빗물저류배수시설)을 준공(2020. 05)하였다. 본 연구에서는 신월빗물저류배수시설 설치에 따른 상습침수구역의 사업 전·후 침수피해 저감효과 검증을 위해 도시유출모형을 구축하여 서울시 방재성능목표 확보여부를 판단하고자 하였다. 기존 설계 당시 서울시 방재성능목표(30년 빈도, 95mm/hr)는 확보되었으나 이를 초과하는 강우(2010. 09, 98.5mm/hr)가 발생함에 따라 수행된 추가 분석(100mm/hr) 결과, 유역의 침수 완전해소를 위해서는 빗물저류배수시설과 더불어 국부적인 간선관거 개량의 필요성이 제시되었다. 이에 따라 본 연구에서는 도시유출모형 구축 시 최근 개선된 하수관로, 지형특성, 홍수량산정표준침(2019, 환경부)등에 따른 수리·수문특성을 반영하고, 신일펌프장(간이)을 추가적으로 고려하여 현재 기준에서의 침수피해 저감 효과를 면밀이 분석하였으며, 그 결과 서울시 방재성능목표 뿐만 아니라 100mm/hr에도 침수가 완전 해소되는 것으로 나타났다. 신월빗물저류배수터널 설치에 따른 침수피해 저감효과 평가 및 분석결과를 통해 자연재해위험개선지구의 해제가 가능할 것으로 판단되며, 지역안전·환경효과, 주민만족도 등 다양한 항목에 대하여 상습침수구역 내 주민설문조사를 수행한 결과 신월빗물저류배수터널에 대한 만족도가 충분히 제고된 만큼 향후 시설의 기능적, 운영적 측면에서의 유지관리가 잘 이루어진다면 침수로부터 안전한 도시를 구현하는데 큰 역할을 할 것으로 기대된다.

  • PDF

Evaluation of Structural Performance for High Strength Rockfall Protection Fence according Reinforcement of H-Beam using Numerical Analysis (수치해석을 통한 지주 보강에 따른 고강도 낙석 방지울타리 구조성능 평가)

  • Hyunwoo Jin;Sanghoon Seo;Duho Lee;Youngcheol Hwang
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.1
    • /
    • pp.25-36
    • /
    • 2023
  • In Korea, the rockfall prevention fence is designed with 50kJ of rockfall kinetic energy in order to prevent damages such as falling rocks and landslides. In the case of rockfall kinetic energy, it is highly dependent on the shape of the slope on which it occurs. As a previous study, a fence performance evaluation was conducted for 100kJ rockfall impact energy using ETAG 27. However, previous studies have focused on newly installed rockfall prevention fences. In this study, a reinforcing materials was installed on the existing rockfall prevention fence through numerical analysis, and the structural performance of the high-strength rockfall prevention fence capable of defending against 120kJ of rockfall kinetic energy was evaluated.