• Title/Summary/Keyword: 불요 방사

Search Result 122, Processing Time 0.031 seconds

A Study on application of EMC to Digital Selective Calling VHF Transceiver for Maritime mobile service (해상이동업무용 디지털선택호출 VHF 송수신장치의 EMC 적용에 관한 연구)

  • 임종근;이동식;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.529-534
    • /
    • 2002
  • It was recommended for all ship engaged in international voyages to carry the dedicated Digital Selective Calling receiver, DSC equipment, VHF transceiver, etc according to Global Maritime Distress & Safety System. Also International Maritime Organization recommended for navigation and communication equipments to applicate the EMC regulations, therefore most of electronic equipments using in the vessel to be faced with problems to cope with new regulations. This study has applied and analyzed the EMC for an equipment integrated with Ch.70 dedicated DSC receiver, DSC equipment, VHF transceiver and groped for solutions to cope with. The test has applied the electromagnetic interference such as the measurement for unwanted emissions from conductive & radio emission and the electromagnetic susceptibility such as the immunity from voltage, frequency variation and electro static discharge, hence comes to be understand the problems related with the power and the earth.

  • PDF

Development of Program for Ignition Temperature and Its Applications (발화온도 산출 프로그램 개발 및 적용)

  • Park, Won-Hee;Cho, Youngmim;Kwon, Tae-Soom
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.4
    • /
    • pp.243-250
    • /
    • 2017
  • A fire phenomenon of a solid such as wood involves a phenomenon in which solid is heated from the outside and the gas generated through the thermal pyrolysis process of the material is burnt. The thermal pyrolysis phenomenon of the solid is a phenomenon in which the amount of energy incident from the outside, the amount of heat dissipation of the solid material, the heat transfer between the solid material and the surroundings including the amount of heat transfer to the air adjacent to the solid surface, and the fraction of oxygen in the air. In this paper, we calculate the required ignition temperature to simulate the fire phenomenon as simple as possible. By using cone calorimeter, the ignition time was measured by variously controlling the heat flux flowing into the wood specimen by using various wood specimens. The user friendly program is developed for calculation of the ignition temperature. Five different woods such as low density MDF, high density MDF, plywood, douglas fir and PB with various thickness are considered. The ignition temperatures suggested in this paper can be used for fire propagation analysis for woods.

Study on Synthesis of Pyrochlore in Gd-Ti-O and Gd-Zr-O Systems (Gd-Ti-O계 및 Gd-Zr-O 계에서의 파이로클로어 합성연구)

  • ;;;S.V. Yudintsev
    • Economic and Environmental Geology
    • /
    • v.37 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Pyrochlores were known as promising materials for the immobilization of radioactive actinide. Accordingly, we synthesized pyrochlores with Gd$_2$Ti$_2$$O_7$ and Gd$_2$Zr$_2$$O_7$compositions by sintering method, and studied its properties and phase relations in Gd-Ti-O and Gd-Zr-O system. The mixed powders were pressed into pellets under 200-400 kgf/cm$^2$ at room temperature. and then sintered at 1000-1$600^{\circ}C$ for 0.5-40 hours. The synthesized samples were analyzed and were identified with XRD and SEM/EDS analyses. The optimal synthetic conditions of pyrochlores with Gd$_2$Ti$_2$$O_7$composition were at 140$0^{\circ}C$/0.5hrs, 130$0^{\circ}C$/3hrs and 120$0^{\circ}C$/20hrs. Its chemical composition was $Gd_{2.0-2.1}$$Ti_{1.9-2.0}$$O_7$ and similar to the stoichiometric composition without any relationship in temperature and atmosphere. The optimal synthetic conditions of pyrochlores with $Gd_{2}$$Zr_{2}$$O_7$composition were at 155$0^{\circ}C$/40hrs and 1$600^{\circ}C$/30hrs. The compositions of pyrochlore synthesized from these optimal conditions were irregular with $Gd_{1.5-2.4}$$Zr_{1.7-2.4}$$O_7$. Such heterogeneity indicates that the reaction rate of pyrochlore with Gd$_2$Zr$_2$$O_7$composition is very low, and then its equilibrium state could not be attained even for 40 hours which was the longest sintering time in this research.

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.

A Study on the Synthesis, Labeling and Its Biodistribution of Estradiol Derivatives (에스트라디올 유도체의 합성, 표지 및 체내동태에 관한 연구)

  • Kim, Sang-Wook;Yang, Seung-Dae;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Lim, Soo-Jung;Choi, Chang-Woon;Lim, Sang-Moo;Kim, Young-Soon;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.403-409
    • /
    • 2000
  • Objectives: Due to the heterogeneous receptor distribution and changes of receptor status over time, the biochemical measurement of estrogen receptor status of biopsy specimens is not sufficient to diagnose breast cancer. As a result, I-123 labeled estradiols have been applied for the diagnosis. The purpose of this study was to develop a suitable radioligand for imaging estrogen receptor-positive human breast tumors. Methods: Among the various estradiol derivatives, $17{\alpha}-[^{123}I]$iodovinyl estradiol ($[^{123}I]$IVE) has been prepared from $17{\alpha}$-ethynyl estradiol. Labeling of $E-17{\alpha}-[^{123}I]$iodovinyl estradiol (E-$[^{123}I]$IVE) was carried out using peracetic acid with $[^{123}I]NaI\;and\;Z-[^{123}I]IVE$ labelling was archived using chloamine-T/HCl solution with $[^{123}I]$NaI. Labeling yield was determined by silica thin-layer chromatography (TLC) and radiochemical purity was measured by high performance liquid chromatography (HPLC). The biodistribution of E-$[^{123}I]$IVE was measured in immature female rats at 60 min, 120 min and 300 min after injection. Results: The labeling yield of two isomers was 92% and 94% ($E-[^{123}I]IVE\;and\;Z-[^{123}I]IVE$, respectively). The radiochemical purity was more than 98% after purification. The highest uptake was observed at 120 min in uterus (3.11% ID/g for E-$[^{123}I]$IVE). Conclusion: These results suggest the possibility of using E-$[^{123}I]$IVE as an imaging agent for the evaluation of the evaluation of the presence of estrogen receptor in patients with breast cancer.

  • PDF

Hydrochemistry and Distribution of Uranium and Radon in Groundwater of the Nonsan Area (논산지역 지하수중 우라늄과 라돈의 수리지질학적 특성과 정밀함량분포)

  • Cho, Byeong Wook;Kim, Moon Su;Kim, Tae Seung;Han, Jin Seok;Yun, Uk;Lee, Byeong Dae;Hwang, Jae Hong;Choo, Chang Oh
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.427-437
    • /
    • 2012
  • A total of 100 groundwater samples were collected from the Nonsan area and the behaviors of uranium and radon as natural radionuclides were investigated with respect to other physicochemical components in the groundwater in order to understand their occurrence, properties, and origins. Radionuclide levels were used to construct detailed concentration maps. The concentration of uranium ranges from 0 to 378 ${\mu}g/L$, with an average of 8.57 ${\mu}g/L$, standard deviation of 42.88 ${\mu}g/L$, and median of 0.56 ${\mu}g/L$. The correlation coefficient between uranium and radon is 0.42, whereas these radionuclides show no relation with other physicochemical components in groundwater. It is noteworthy that the uranium level in most samples (97% of the samples) is less than 30 ${\mu}g/L$, where the bedrock of the aquifer is granite or complex rocks located along the boundary between granite and metamorphic rocks. In the Okcheon metamorphic belt, the uranium concentration of most groundwater is less than 1 ${\mu}g/L$. Radon levels varies from 128 to 9,140 pCi/L, with an average of 2,186 pCi/L, standard deviation of 1,725 pCi/L, and median of 1,805 pCi/L. High radon levels (> 4,000 pCi/L) are most common in regions of Jurassic granite, whereas low radon areas are found in regions of sedimentary rock. In conclusion, the distribution and occurrence of radionuclides are intimately related to the basic geological characteristics of the rocks in which the radiogenic minerals are primarily contained.

Occurrence of Uranium-238 and Rn-222 in Groundwater and Its Relationship with Helium Isotope (지하수 내 우라늄-238 및 라돈-222 산출과 헬륨 동위원소와의 상관성 연구)

  • Jeong, Chan Ho;Lee, Yu Jin;Lee, Yong Cheon;Hong, Jin Woo;Kim, Cheon Hwan;Nagao, Keisuke;Kim, Young-Seog;Kang, Tae-Seob
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.659-669
    • /
    • 2021
  • The purpose of this study is to elucidate the relationship between occurrence of natural radioactive materials such as 238U and 222Rn and original mixing ratio of helium isotope of groundwater from various geology, and to suggest the underground aquifer environment from helium original mixing data. 9 groundwater samples were collected from five study areas, and 238U, Rn-222 and helium isotope were analyzed. A high 238U content of the range of 218~477 ㎍ /L in the groundwater occurs in the twomica granite. 4He air-crust mixing ratio and the Rn-222 content show a rough relation, that is, Rn-222 content increases according to the increase of 4He crust mixing ratio. Because of helium and radon are an inert gas, their behavior in underground environment is assumed as an analogous. The 238U content and He isotope in groundwater does not show any distinct correlation. The groundwater can be classified as three groups (air, air-crust mixing, crust-mantle mixing origin) on the diagram of 3He/4He vs 4He/20Ne, which is composed of original mixing line from air-crust-mantle end members. This original mixing of helium can provide the information of underground aquifer characteristic such as the connection with surface environment or isolation condition from air environment.

Development of Pilot-Scale Manufacturing Process of SiC Fiber from Polycarbosilane Precursor with Excellent Mechanical Property at Highly Oxidation Condition and High Temperature (폴리카보실란 전구체로부터 고온 산화성분위기서 기계적물성이 우수한 파이롯-규모의 탄화규소섬유 제조공정 개발)

  • Yoon, B.I.;Choi, W.C.;Kim, J.I.;Kim, J.S.;Kang, H.G.;Kim, M.J.
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.116-125
    • /
    • 2017
  • The purpose of this study is to develop silicon carbide fiber showing an excellent mechanical properties under highly oxidative conditions at high temperature. Polycarbosilane(PCS) as a preceramic precursor was used for making the SiC fiber. PCS fiber was taken by melt spinning method followed by melting the PCS at $300{\sim}350^{\circ}C$ in N2 gas. The Curing of PCS fiber was carried out in air oxygen chamber, prior to high temperature pyrolysis. Degree of cure was calculated by characteristic peak's ratio of Si-H to $Si-CH_3$ in FT-IR spectra before and after curing of PCS fiber. The properties of SiC fiber was affected greatly by the degree of cure. The SiC fiber produced by controlling fiber tension during heat treatment showed good properties. The SiC fiber exposed to $1000^{\circ}C$ at air from 1 min. up to maximum 50 hrs showed around 60% reduction in tensile strength. We found that large amount of carbon content on the fiber surface after long-term exposure has resulted in lower tensile strength.

Recurrent ossifying and cemento-ossifying fibroma of the jaws;report of 2 cases (재발된 골섬유종과 백악질골섬유종)

  • Ryu, Sun-Youl;Oh, Hee-Kyun;Kim, Geon-Jung;Yun, Young-Su;Choi, Hong-Ran
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.297-308
    • /
    • 1989
  • These are two case reports of recurrent ossifying and cemento-ossifying fibroma in a year or 5 months following conservative treatment. Ossifying fibroma or cemento-ossifying is a relatively uncommon benign fibro-osseous tumor of the jaws, and is generally believed to originate from periodontal ligaments. In recent, it is not demanded more differentiation of ossifying, cementifying and cemento-ossifying fibroma due to the thought that these lesions represent a spectrum of the same disease process rather than separate entities. The tumor commonly presents as an asymptomatic mass lesion and is usually well-circumscribed clinically so that conservative surgical excision has been the treatment of choice, but on occasion extended surgical procedures may become necessary, especially for those tumors which demonstrate rapid expansions and are poorly encapsulated (either initially or when recurrent) and when tumor growth is progressed aggressively or recurrent. En-bloc resection of mandible with iliac bone and inferior alveolar nerve graft was performed in case 1, recurrent cemento-ossifying fibroma of 32-year old male patient, and extended surgical enucleation of mass including normal marginal bone was done in case 2, recurrent ossifying fibroma of 72-year old female patient. By follow-up check of the patients, we obtained good result without any sings of recurrence.

  • PDF