• Title/Summary/Keyword: 불균일보정

Search Result 69, Processing Time 0.028 seconds

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.

A Study on Batch-Type Remote Plasma Dry Cleaning Process for Native Oxide Removal (배치식 플라즈마 세정 설비를 이용한 자연산화막 제거 공정)

  • Park, Jae-Young;Yi, Wook-Yeol;Hyung, Yong-Woo;Nam, Seok-Woo;Lee, Hyeon-Deok;Song, Chang-Lyong;Kang, Ho-Kyu;Roh, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.247-251
    • /
    • 2004
  • 반도체 소자의 제조에 있어 실리콘 표면에 성장한 자연산화막을 제거하기 위해 일반적으로 습식 세정 기술이 이용되어 왔다. 하지만 소자의 최소 선폭(design rule)이 nano급으로 고집적화 됨에 따라 contact hole 바닥의 자연산화막을 깨끗이 제거하는데 있어서 그 한계를 나타나고 있다. 이에 대한 효과적인 대안 공정으로 가스 건식 세정 기술이 연구되고 있다. 본 논문에서는 한 번에 50매 이상의 웨이퍼를 처리함으로써 생산성 측면에서 월등한 배치식 설비에서 원거리 플라즈마(remote plasma) 장치에서 2.450Hz의 마이크로웨이브(${\mu}$-wave)에 의해 형성시킨 수소라디칼과 $NF_3$ 가스를 이용하여 실리콘에 결함을 주지 않고 자연산화막을 선택적으로 제거하는 공정에 대해 고찰하였다. AFM을 이용한 표면분석, TEM을 이용한 물성분석, 그리고 ToF-SIMS 및 XPS를 이용한 화학 분석을 습식 및 건식 세정을 비교 평가한 결과, 건식 세정 공정이 실리콘 표면에 결함을 주지 않고 자연산화막을 제거 할 수 있음을 확인하였다. 산화막$(SiO_2)$, 질화막$(Si_3N_4)$, 그리고 다결정 실리콘(Poly-Si) 등의 각 막질별 식각 특성을 고찰하였으며, $NH_3$의 캐리어 가스인 $N_2$의 주입량을 조절함으로써 수소라디칼 형성 효율의 개선이 가능하였으며, 이로부터 게이트와 소스/드레인 사이를 절연하기 위해 이용되는 질화막의 식각 선택비를 2배 정도 개선할 수 있었다. nano급 소자에 실장하여 평가한 결과에서 불산(HF)에 의한 습식 세정 방식에 비하여 약 $20{\sim}50%$ 정도의 contact 저항 감소 효과가 있음이 확인되었다.두 소자 모두 $40mA/cm^2$ 에서 이상적인 화이트 발란스와 같은(0.33,0.33)의 색좌표를 보였다.epsilon}_0=1345$의 빼어난 압전 및 유전특성과 $330^{\circ}C$의 높은 $T_c$를 보였고 그 조성의 vibration velocity는 약4.5 m/s로 나타났다.한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다. 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만들기, 일반화가 가능한 문제 등으로 보고, 수학적 창의성 중 특히 확산적 사고에 초점을 맞추어 개방형 문제가 확

  • PDF

Surgical Results for Treating Postpneumonectomy Empyema with BPF by Using an Omental Pedicled Flap and Thoracoplasty (전폐절제술 후 기관지 흉막루를 동반한 농흉에서 유경성 대망 이식편과 흉곽성형술을 이용한 수술적 치료에 대한 임상 고찰)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.420-427
    • /
    • 2007
  • Background: Postpneumonectomy empyema (PPE) due to bronchopleural fistula (BPF) can be a surgical challenge for surgeons. We analyzed the follow-up outcomes after performing omentopexy and thoracoplasty for the treatment of PPE with BPF after pneumonectomy. Material and Mehod: Between December 1991 and January 2006, 9 patients underwent BPF closure using an omental pedicled flap for the treatment of PPE with BPF after pneumonectomy. There were 7 males and 2 females (mean age: $45.9{\pm}9$ years). The patients were followed up for a mean of 58 months (median: 28 months, range: $6{\sim}169$). When we performed omentopexy, the surgical procedures for empyema were thoracoplasy for 8 patients and the Clagett procedure for 1 patient. Thoracoplasty was performed for the latter patient due to recurrence of empyema, Result: For the 8 patients who were treated by omentopexy and thoracoplasty, there was 1 operation-related death due to sepsis. During follow up, 1 patient, who was treated by omentopexy and a Clagett procedure, died of acute hepatitis 40 months postoperatively. The early mortality was 11.1% (8/9). Of the 8 patients, including the 1 late death patient, successful closure of the BPF were achieved in all patients (8/9) and the empyema was cured in 7 patients (7/8). Conclusion: The BPF closure using an omental pedicled flap was an effective method for treating PPE with BPF due to 75-destroyed lung, and thoracoplasty with simultaneous omentopexy was effective and safe for removing dead space if the patient was young and in a good general condition.

휴대형 당도판정센서를 이용한 배의 당도 판정

  • 이강진;최규홍;강석원;최완규;손재룡
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.120-121
    • /
    • 2003
  • 과수원에서 재배되는 배는 과수원 내의 위치, 시비, 토양 등의 요인에 따라 다양한 품질을 나타내며, 당도와 숙도의 편차가 크기 때문에 과수농가에서는 경험에 의존하여 적정 숙기로 판단되는 배를 수확하고 있다. 그러나 과학적이지 못한 사실에 기초한 수확 관행은 시장유통되는 배에 대하여 소비자들의 신뢰성 저하를 초래하게 되고 소비 감소와 더불어 농가 소득 감소로 이어지게 된다. 최근, 전국의 청과물 산지유통센터에는 근적외선을 이용하여 과일 내부의 당도, 산도, 결함 등을 실시간으로 판정할 수 있는 비파괴 선별기가 보급되고 있으나 이는 수확이후의 선별.규격화 유통을 위한 것이다. 본 연구에서는 이와는 달리, 수확 이전, 즉 재배 단계에서 배의 당도와 숙도를 판정하여 수확적기를 판단할 수 있도록 나무에 매달린 배에 대하여 가시광선과 근적외선 반사스펙트럼을 측정할 수 있고 이를 이용하여 당도와 숙도가 판정가능한 휴대형 센서를 개발하였으며, 개발된 시작기를 이용하여 당도판정의 가능성을 시험하였다. 휴대형 당도판정센서는 광원과 광섬유프로브, 광검출부, 당도판정부, 전원공급부로 구성된다. 광원은 할로겐램프(6V)를 이용하였고, 광섬유프로브는 동심원 형태로서 외부의 광섬유를 통하여 광원에서 시료로 빛이 조사되게 하고, 내부의 광섬유를 통하여 광검출기로 확산반사되는 광이 전달될 수 있도록 하였다. 전원공급부는 휴대와 충전이 가능한 배터리(12V, 2AH)와 이 배터리에서 정전류가 광원으로 보내어 질 수 있도록 제작된 회로로 구성하였다. 당도 판정을 위하여 518nm에서 1046nm의 파장대역에서의 반사스펙트럼을 이용하였고, 레퍼런스로써 백색 테플론 구를 제작하여 사용하였다. 수원 농산물 도매시장에서 판매중인 2002년산 신고 배를 구매하고, 시작기를 이용하여 총 113개의 배에 대한 반사스펙트럼을 측정하였다. 다음으로 굴절당도계로 당도값을 측정하고 반사스펙트림을 이용하여 당도값을 예측하기 위한 부분최소제곱회귀(PLSR)모델을 개발하였다. 여기서 모델의 정밀도는 교차검정법을 이용하여 검증하였다. 시료 표면과 광섬유프로브와의 접촉상태 불균일, 광원의 시간에 따른 경시 변화, 과일 형상의 차이 등에 의하여 측정된 반사스펙트럼은 상당한 변이를 나타내었으므로 이를 보정하기 위하여 반사 스펙트럼은 다분산보정처리하여 이용하였다. 당도 예측용 PLSR모델 개발의 결과, 모델의 결정계수($R^2$)는 0.67, SEC는 $\pm$0.4brix.로 나타났으며, 교차검정에 의한 미지 시료의 예측에서 총 113개의 미지 시료에 대한 결정계수는 0.57, SEP는 $\pm$ 0.46brix.로 나타났으며, 이는 현장에서 충분히 활용가능할 것으로 판단되었다. 금후, 전체 시스템의 부피와 중량을 줄이고 각 부분품들의 전력소모의 최소화할 수 있도록 개선할 계획이다.

  • PDF

Real-Time Fixed Pattern Noise Suppression using Hardware Neural Networks in Infrared Images Based on DSP & FPGA (DSP & FPGA 기반의 적외선 영상에서 하드웨어 뉴럴 네트워크를 이용한 실시간 고정패턴잡음 제어)

  • Park, Chang-Han;Han, Jung-Soo;Chun, Seung-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.94-101
    • /
    • 2009
  • In this paper, we propose design of hardware based on a high speed digital signal processor (DSP) and a field programmable gate array (FPGA) for real-time suppression of fixed pattern noise (FPN) using hardware neural networks (HNN) in cooled infrared focal plane array (IRFPA) imaging system FPN appears a limited operation by temperature in observable images which applies to non-uniformity correction for infrared detector. These have very important problems because it happen serious problem for other applications as well as degradation for image quality in our system Signal processing architecture for our system operates reference gain and offset values using three tables for low, normal, and high temperatures. Proposed method creates virtual tables to separate for overlapping region in three offset tables. We also choose an optimum tenn of temperature which controls weighted values of HNN using mean values of pixels in three regions. This operates gain and offset tables for low, normal, and high temperatures from mean values of pixels and it recursively don't have to do an offset compensation in operation of our system Based on experimental results, proposed method showed improved quality of image which suppressed FPN by change of temperature distribution from an observational image in real-time system.

The usefulness of Forward IMRT for Head and Neck Cancer (두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰)

  • Baek Geum Mun;Kim Dae Sup;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 2003
  • I. Purpose The dose distribution in normal tissues and target lesions is very important in the treatment planning. To make the uniform dose distribution in target lesions, many methods has been used. Especially in the head and neck, the dose inhomogeneity at the skin surface should be corrected. Conventional methods have a limitation in delivering the enough doses to the planning target volume (PTV) with minimized dose to the parotid gland and spinal cord. In this study, we investigated the feasibility and the practical QA methods of the forward IMRT. II. Material and Methods The treatment plan of the forward IMRT with the partial block technique using the dynamic multi-leaf collimator (dMLC) for the patients with the nasopharyngeal cancer was verified using the dose volume histogram (DVH). The films and pinpoint chamber were used for the accurate dose verification. III. Results As a result of verifying the DVH for the 2-D treatment plan with the forward IMRT, the dose to the both parotid gland and spinal cord were reduced. So the forward IMRT could save the normal tissues and optimize the treatment. Forward IMRT can use the 3-D treatment planning system and easily assure the quality, so it is easily accessible comparing with inverse IMRT IV. Conclusion The forward IMRT could make the uniform dose in the PTV while maintaining under the tolerance dose in the normal tissues comparing with the 2-D treatment.

  • PDF

A study on the dose distribution for total-body & hemibody irradiation using clinical photon beams (광자선을 이용한 전신 및 반신조사의 선량분포에 관한 고찰)

  • 김진기;권형철;김정수;오영기;김기환;신교철;김정홍;박충기;정동혁
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.147-153
    • /
    • 2001
  • We have discussed that the total body irradiation(TBI) dose distribution of 6 and 10 MV photon beams, also differences between calculation dose use of compensator sheet and measurements in humanoid phantom. Total body irradiation and hemi-body irradiation(HBI) can be effectively performed when uniformity of dose distribution is estabilished. The method of TBI and HBI dosimatry requires special considerations related to technique, long distance and very large field, machine parameter, patient positioning. TBI and HBI with megavoltage photon beams requires basic dosimatric data which have to be measured directly or derived from the standard beam data. The semiconductor detector and ion chamber were positioned at a dmax depth, mid depth, and its specific ratio was determined using a scanning data by RFA-7 3-dimensional water phantom and solid phantom. The effective source axis distance 380 cm, the field size from 120 cm to 152 cm, isodose distributions were analyzed as a function of the thickness in phantom. Also, have discussed that the measurement of basic data for clinical photon beams for dosage calculations, data calculation sheet and the use of tissue compensation to improve dose uniformity. We have improved a dose uniformity in the TBI and HBI method.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.