• Title/Summary/Keyword: 분해능 보정

Search Result 90, Processing Time 0.035 seconds

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

Limitations of time resolution and spatial overlap caused by group velocity mismatch in experiments using ultrashort UV and visible optical pulses. (자외선과 가시광선 극초단 펄스 실험의 군속도 차이에 의한 시간 분해능 및 공간 겹침의 제한)

  • 김성규
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.252-259
    • /
    • 1994
  • The method of calculating overlap dispersion caused by group velocity mismatch between uv and visible pulses in ultrafast pump-probe experiments is presented to discuss limitations of the time resolution and signal intensity. The calculations show arrangements using a single focusing lens shall result in undesirable time resolution and low signal intensity. Achromatic doublets result in unrealistic solutions. However, dramatic improvement in the time resolution and signal intensity is expected in the optical arrangements using separate lens for each pulse and in the arrangements using a cutoff secondary lens with a main lens. lens.

  • PDF

Development of Error Compensation Program for the Articulating Probe Calibration (다중 프로브 교정 오차 보정에 관한 연구)

  • 김형주;이동주;정광진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.9-14
    • /
    • 2004
  • 이 논문에서는 다중 프로브 교정 시 발생하는 오차를 측정하여 보정함으로써 측정 정밀도를 향상시킬 수 있는 프로그램을 개발에 대하여 연구하였다. 교정 시와 동일한 조건으로 기준구를 측정하여 오차를 산출한 다음 프로브 파라미터가 기록된 시스템 파일을 수정함으로써 교정 오차를 보정하는 프로그램을 개발하였다. 실험 결과 이론값과 실제값의 차가 CMM 분해능의 2배 이내임을 확인하였으며 프로그램은 CMM 사용자가 직접 작성 및 편집 가능하도록 DMIS 언어를 사용하였다.

  • PDF

표면분석용 Coaxial Impact Collision Ion Scattering Spectroscopy (CAICISS)장치의 제작과 특성

  • 김기석;김용욱;박노길;정광호;황정남;김성수;윤희중;최대선
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.1
    • /
    • pp.8-16
    • /
    • 1994
  • 표면분석용CAICISS장치를 제작하고 He+과 Li+이온을 사용하여 장치의 특성을 조사하였다. 장치 분해능의 평가기준으로 이용할 수 있는 ΔT를 정의하고 Li+ 이온을 사용했을 경우와 비교한 결과 He+ 이온의 경우 ΔT/T=0.034, Li+ 이온의 경우 ΔT/T=0.04로서 Li+이온의 경우가 분해능이 약간 떨어짐을 알았다. 그리고 Ta, Al 표적시료에 대한 실험결과를 보정함수를 이용하여 계산값과 비교한 결과 잘 일 치함을 확인하였고 보정함수는 입사이온의 에너지와 표적원자의 질량에는 무관하고 실험조건에만 의존 함을 알았다. 또한 Si(100) 표면에 He+ 이온을 입사하여 입사각에 따른 산란강도 분포 스펙트럼으로부터 CAICISS 장치로 표면 1∼4 원자층의 Si 원자에 대한 기하학적인 배열을 확인하였다.

  • PDF

NSOM 장치의 제작 및 광특성 연구

  • ;A.K.Viswanath
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.75-75
    • /
    • 1999
  • 100nm 공간 분해능을 갖는 NSOM 장치를 자체 제작하고 computer를 이용하여 측정을 자동화 하였다. 압전소자의 인가된 전압에 대한 이동거리를 x, y, z 축에 따라 측정 및 보정하고 NSOM topography 사진을 얻는데 성공하였다. 이때 이동거리는 x, y 축은 약 20nm/V이고, z 축은 2.5nm/V 이었다. 하지만 압전소자의 인가된 전압에 따른 이동거리의 비선형성에 대한 보정 및 feedback 제어의 안정화 등은 앞으로 해결해야할 문제로 남아 있다. 자체제작된 NSOM을 이용하여 GaAs/AlGaAs MQWs와 InAs/GaAs QDs 시료에 대한 PL, photocurrent 및 reflectance 등 분광 실험을 성공적으로 수행하였다. PL 실험의 경우 첨예한 광 섬유에 보내진 레이저 광의 세기가 매우 미약하기 (수십 nW) 때문에 탐침 크기가 약 500nm 일 때 측정되었다. 하지만 photocurrent 실험에서는 시료를 검출기로 사용하기 때문에 신호대 잡음비가 PL에 비하여 100배 이상 좋아지는 것을 발견하였다. 따라서 NSOM을 이용한 photocurrent 방법은 앞으로 NSOM의 공간 분해능을 높이는데 하나의 돌파구를 마련해 줄 것으로 기대된다.

  • PDF

Construction and Performance Characterization of Time-correlated Single Photon Counting System having Picosecond Resolution (피코초 분해능의 시간 상관 단광자 계수 장치 구성 및 동작 특성)

  • 이민영;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • Picosecond time-correlated single photon counting system and time-resolved luminescence spectrometer were constructed, employing a mode-locked picosecond laser, fast electronics, and microchannel plate tube. It has been shown that the instrument response function critically depends on laser pulse shape, timing jitter and walk of the electronics, and characteristics of detector and amplifier. Correcting time dispersion in the optical system, the best instrument response function obtained appears to be 25 ps, which made it possible to measure the luminescence lifetime with less than 10 ps resolution in the picosecond to microsecond range. range.

  • PDF

DEVELOPMENT OF MAGNETOMETER DIGITAL CIRCUIT FOR KSR-3 ROCKET AND ANALYTICAL STUDY ON CALIBRATION RESULT (KSR-3 과학 로켓용 자력계 디지털 회로 개발 및 검교정시험 결과 분석 연구)

  • 이은석;장민환;황승현;손대락;이동훈;김선미;이선민
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.293-304
    • /
    • 2002
  • This paper describes the re-design and the calibration results of the MAG digital circuit onboard the KSR-3. We enhanced the sampling rate of magnetometer data. Also, we reduced noise and increased authoritativeness of data. We could confirm that AIM resolution was decreased less than InT of analog calibration by a digital calibration of magnetometer. Therefore, we used numerical-program to correct this problem. As a result, we could calculate correction and error of data. These corrections will be applied to magnetometer data after the launch of KSR-3.

Resolution Limits of Cross-Well Seismic Imaging Using Full Waveform Inversion (전파형 역산을 이용한 시추공 영상의 분해능)

  • Cho, Chang-Soo;Lee, Hee-Il;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.1
    • /
    • pp.33-45
    • /
    • 2002
  • It was necessary to devise new techniques to overcome and enhance the resolution limits of traveltime tomography. Waveform inversion has been one of the methods for giving very high resolution result. High resolution image could be acquired because waveform inversion used not only phase but amplitude. But waveform inversion was much time consuming Job because forward and backward modeling was needed at each iteration step. Velocity-stress method was used for effective modeling. Resolution limits of imaging methods such as travel time inversion, acoustic and elastic waveform inversion were investigated with numerical models. it was investigated that Resolution limit of waveform inversion was similar tn resolution limit of migration derived by Schuster. Horizontal resolution limit could be improved with increased coverage by adding VSP data in cross hole that had insufficient coverage. Also, waveform inversion was applied to realistic models to evaluate applicability and using initial guess of travel time tomograms to reduce non-linearity of waveform inversion showed that the better reconstructed image could be acquired.

Off-Axis Illumination (패턴 분해능 및 초점심도 향상에 대한 사입사 조명)

  • 박정보;이성묵
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.453-461
    • /
    • 1999
  • In this paper, we have studied on the effects of annular and quadrupole illuminations by changing their conditions for enhancing the pattern resolution and depth of focus (OaF) in the optical lithography system using KrF Eximer laser 0.248$\mu$m and 0.65 NA. As a result, it is revealed that each illumination condition to optimize the resolution and the OaF for the mask containing the assistance pattern is different under the annular illumination. And in case of quadrupole illumination, we could ascertain that the resolution and the OaF would be enhanced through changing the arrangement of each pole from the conventional X type (45 degrees) to some proper type according to the main pattern direction. ction.

  • PDF

LPG Dispensing Control System (LPG 충전 제어시스템)

  • 이상훈;최병철;박남철
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.113-113
    • /
    • 2000
  • LPG 및 석유류는 온도에 따라서 유량의 변화가 LPG의 경우는 ±0.23%/℃, 무연은 ±0.11%/℃, 등유는 ±0.10%/℃, 경유의 경우는 ±0.09%/℃로 특히 LPG의 경우가 그 변화가 심하므로 정확한 충전량을 계량하는 것이 중요하다. 이는 공정거래 확립의 차원에서 공급자와 소비자 입장에서 반드시 요구되는 사항이다. 이를 위해 본 논문에서는 LPG 충전기의 충전제어 및 자동 온도 보정의 알고리즘을 개발하고 이를 프로그래밍한 후 온도센서와 16-bit 마이크로프로세서(intel 80C196)로 자동 온도 보정이 가능한 LPG 충전기의 충전제어 시스템을 설계 및 제작하였다. 설계 제작된 시스템은 프로세서부, I/O 입ㆍ출력부, VFD(vacuum fluorescent display) 디스플레이 구동부로 구성된다. 충전제어 동작은 LPG 유량계의 encoder로부터의 유량(유속)신호와 기차 보정값 및 15℃를 기준으로 한 온도 센서부의 온도 보정값을 입력받아 솔레노이드 밸브를 제어하여 충전을 제어하게 된다. 온도 보정은 80C196 프로세서의 내부 10-bit A/D 변환기를 사용하여 0.5℃ 분해능으로 온도제어를 할 수 있다. VFD 디스플레이는 유량, 금액, 단가가 표시되며 그 값을 누적시켜 일계, 월계를 알 수 있게 하였다. 그 외에 시스템 진단기능 및 컴퓨터통신, POS 통신이 가능하도록 하였다. 제작된 시스템을 LPG 충전기에 실장하여 시험한 결과 목표한 정확도로 유량이 제어됨을 알 수 있었다.