• Title/Summary/Keyword: 분석법

Search Result 26,323, Processing Time 0.062 seconds

Characteristics of the Continuous Measurement and the Fuel Analysis for Emission Calculation of Carbon Dioxide in a Coal Fired Power Plant (석탄화력발전소 이산화탄소 배출량 산정을 위한 연료분석법과 연속측정법의 특성)

  • Choi, Hyun-Ho;Yoo, HoSeon
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2017
  • This study calculates carbon dioxide emissions using the fuel analysis and the continuous measurement from 500 MW-class coal-fired power plants and evaluates the characteristics of each method. The emissions calculation using fuel analysis was the lowest calculation among the emissions calculation methods. This is because of low net calorific value analysis. When using the low calorific coals, it is beneficial to utilize the fuel analysis. Also it showed the characteristics of the lower calculation emissions when used the as fired coals than the as received coals. However, the difference is negligible to less than 2%. As sample analysis personnel and equipment are limited in the present circumstances, it is also deemed appropriate to use the as received coals to fuel analysis. Continuous measurement showed somewhat higher emissions than the fuel analysis, and lower emissions than calculation method using domestic emission factors. Thus, if the calculated emission using fuel analysis increases with the coal type changes, it is beneficial to using modified flow rate measurement method.

  • PDF

A Studies of Uranium Isotopes Determination in Environmental Samples Using TBP Extraction (TBP 용매추출법을 이용한 토양시료중 우라늄 동위원소 분석법 개선에 대한 연구)

  • Lee, Myung-Ho;Choi, Geun-Sik;Cho, Young-Hyun;Lee, Chang-Woo;Jung, Sung-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • Using the TBP slovent extraction method, a simple and precise method for determining uranium isotopes in the environment samples was developed. The soil sample was decomposed with $HNO_3$ and HF. Uranium isotopes were extracted with 15% TBP in $CCl_4$ from aqueous phase to organic phase, and Th fraction was removed with 8M HCl. Uranium fraction was purified in back extraction step with 1M HCl. Optimized electrode position conditions of uranium Isotopes were set using a new electrode position solution including a DTPA chelating agent. The new method of uranium isotopes determination was validated with a result of application to IAEA Reference Soils.

  • PDF

Characteristics of trace analysis of potential diesel oxygenates using the factorial design in solid-phase microextraction with GC/FID (고체상미량분석법(SPME-GC/FID)에서 요인배치법을 이용한 디젤첨가제의 미량분석의 특성 평가)

  • Park, Jae-Sang;Chang, Soon-Woong
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.370-382
    • /
    • 2007
  • In this study, solid-phase microextraction (SPME) technique using GC/FID was studied as a possible alternative to liquid-liquid extraction for the analysis of EGBE, DGBE, DBM and TGME in water, and an optimization condition of trace analysis of EGBE, DGBE, DBM and TGME using the factorial design was described. Experiments used a fractional factorial design method followed by central composite design allowing optimization of a number of factors as well as statical analysis of results. The response surface analysis showed that the extraction efficiency can be described by a second-order polynomial equation in which the salts concentration, extraction temperature, extraction time and sonication time are the major influences. Using DOE, a new data-dependent method was developed that improved the quantity of confidently analyzed EGBE, DGBE, DBM and TGME in water samples.

A Study oil the Next-bit Test (Next-bit 검정 방법 분석)

  • 강주성;박상우;박춘식
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 1998.12a
    • /
    • pp.345-353
    • /
    • 1998
  • 본 논문에서는 next-bit 검정의 이론적 배경을 고찰하고, 실제적인 검정법으로 구현된 검정방법에 대하여 조사 분석한다. Next-bit 검정 이론은 Schrift와 Shamir가 제시한 다양한 검정방법을 중심으로 소개한다. 그리고 구현된 통계적 검정 방법은 ACISP'96에서 발표된 검정법과 CISC'97에서 제안된 검정법을 비교 분석한다.

  • PDF

The Performance Analyparkof Bandlimited WCDMA Systems (대역이 제한된 광대역 코드분할 다중화 시스템의 성능 분석)

  • Kim, Young-Sam;Park, Joong-Hoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4A
    • /
    • pp.193-199
    • /
    • 2003
  • In this paper, the performance of uplink WCDMA systems was analyzed using the SGA (Standard Gaussian Approximation) method and the SIGA(Simplified Improved Gaussian Approximation) method adopted for the performance analysis in conventional DS-CDMA systems. The performance of bandlimited WCDMA systems was analyzed using the SGA and SIGA method, and computer simulations were performed in AWGN environments having multiple access interference. It was shown that the performance analysis of uplink bandlimited WCDMA systems using the SIGa method may be very efficient through various computer simulations with verying spreading factors, roll-off factors, and signal-to-noise ratios.

Improvement of Transformer Diagnosis Reliability by Head-space Extraction (헤드스페이스 추출에 의한 절연유중 가스 분석방법의 신뢰도 향상)

  • Park, Hyun-Joo;Hwang, Seon-Jin;Lim, Byoung-Hoon;Choi, Byoung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.383-385
    • /
    • 2008
  • 본 논문은 헤드스페이스 추출에 의한 절연유중 가스분석 결과의 정확도 향상을 위해 여러 가지 인자들을 고려하였으며, 진단결과의 신뢰도 향상을 위해 표준절연유를 직접 제조하여 이에 의한 교정을 통해 분석법의 진단 신뢰도 향상을 제고하였다. 기존의 추출율이 높은 토플러 추출방법에 대한 결과와 Headspace 분석법에 의한 결과를 각각 비교하고, Headspace 추출법에 의한 결과의 정확도 향상을 위해 여러가지 인자들을 고려하였다. 향후 최적 조건을 수립하여 수은에 의한 인체 유해성이 없는 Headspace 분석법으로의 전환을 모색하고자 한다.

  • PDF

A study of plasma diagnostics and plasma processing monitoring by using Floating Harmonics Analysis (부유 고조화 분석법을 이용한 플라즈마 진단 및 플라즈마 공정 모니터링 기술 연구)

  • Jeong, Jin-Uk
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.178-179
    • /
    • 2015
  • 량뮤어 탐침 기반의 부유 고조화 분석법이 최근 개발되어서 증착, 식각 공정에서 플라즈마 변수 진단이 가능하게 되었다. 고조화 분석법은 탐침에 교류의 전압을 인가하고, 탐침 전류를 측정하는 방식이다. 탐침 쉬스의 비선형성으로 인해 전류의 고조화 성분들이 생긴다. 이러한 고조화 전류 성분들은 플라즈마 변수인 밀도와 전자온도의 함수로 주어지고, 고조화 전류 성분들로부터 밀도와 전자온도를 추출할 수 있다. 또한 전류와 전압의 위상차를 측정하여 탐침-플라즈마의 임피던스의 리액턴스 성분으로부터 탐침에 증착되는 막의 두께도 모니터링이 가능하다. 이러한 부유 고조화 분석법을 적용하여 공정 플라즈마 진단 모니터링 결과를 소개한다.

  • PDF

Speaker Recognition Based on Robust PCA (강인한 주성분 분석법을 갖는 화자인식)

  • Lee Youn Jeong;Lee Ki Yong
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.225-228
    • /
    • 2002
  • 본 논문에서는 화자인식을 위하여 강인한 주성분 분석법(Robust Principal Component Analysis)을 갖는 화자인식 방법을 제안하였다. 강인한 주성분 분석법은 특징벡터들의 outlier가 존재할 경우 k-차원으로 줄이면서 강인한 화자 모델을 만들기 위하여 사용한다. 기존의 PCA 방법은 순수한 화자의 정보가 잡음 등의 outlier에 의해 손상될 수 있으므로, 강인한 주성분 분석법을 사용하여 outlier의 영향을 감소 시켰다. 화자 별로 k-차원 diagonal GMM 학습시 mixture 수를 적응시켜 데이터 저장 공간을 최소화하였다. 200명의 고립 숫자음을 사용하여 기존의 diagonal GMM 방법과 제안된 방법을 실험한 결과, 제안된 방법에서 약 $1.5\%$더 높은 인증률을 얻을 수 있었다.

  • PDF

Comparison and evaluation of methods for the measurement of total nitrogen in wastewater (고농도 질소함유 폐수의 총질소 분석법 비교·평가)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • The measurement methods for total nitrogen in wastewater containing a high concentration of nitrogen were evaluated. (1) The UV spectrophotometry, (2) reduction-distillation Kjeldahl, (3) total Kjeldahl nitrogen, and (4) ion chromatography methods were applied. The experimental procedure of the UV spectrophotometric method was simple, but it produced large errors deriving from the dilution of samples and calibration standards. While, the reduction-distillation Kjeldahl method didn't need dilution, but the amount of Devarda's alloy and NaOH lead to large errors up to 50 mg/L. The levels of total nitrogen measured by each method were as follows: reduction-distillation Kjeldahl ($568.6{\pm}38.7mg/L$) > UV spectrophotometry ($527.3{\pm}9.6mg/L$) > total Kjeldahl nitrogen method ($494.7{\pm}21.4mg/L$) > ion chromatography method ($417.9{\pm}7.3mg/L$). Therefore, the reduction-distillation Kjeldahl method is preferred for wastewater with the high concentration of nitrogen. Optimal conditions for each experimental procedure, however, are needed to be confirmed, and the Standard Operation Procedure (SOP) for total nitrogen is required for reliable measurements.

Analysis of Applicability of Nonstationary Rainfall Frequency Analysis (강우의 증가경향성을 고려한 확률강우량 산정법의 적용성 분석)

  • Lee, Chang-Hwan;Ahn, Jae-Hyun;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1277-1281
    • /
    • 2009
  • 본 연구에서는 권영문 등(2009)에서 제시한 강우의 증가경향성을 고려한 목표년도 확률강우량 산정법의 적용성을 검토하기 위하여 누적평균강우량 회귀직선의 적합도 분석과 모수와 누적평균강우량의 상관분석을 실시하였다. 서울지점의 1961-2006년 관측 강우자료를 바탕으로 지속기간 24시간 연 최대치 자료계열을 구축하여, 정상성 강우빈도해석법을 이용한 확률강우량과 비정상성 강우빈도해석법에 의한 확률강우량을 비교 분석하였다. 여러 가지 경우의 누적평균강우량에 대해서 분석을 실시한 결과, 비정상성 강우빈도해석법에 의한 확률강우량의 적용성이 우수한 것으로 나타났다.

  • PDF