• Title/Summary/Keyword: 분사 노즐

Search Result 538, Processing Time 0.029 seconds

Numerical Analysis of the Flow Characteristics of High-Pressure Injection Nozzle for Machine Tools (공작기계용 HP Holder 분사노즐 유동특성에 관한 수치해석)

  • Yi, Chung-Seob;Yun, Ji-Hun;Jeong, In-Guk;Song, Chul-Ki;Suh, Jeong-Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1061-1066
    • /
    • 2011
  • In this study, the flow characteristics of an injection nozzle installed in a high-pressure holder for improving productivity were determined. The inlet velocity, nozzle inflow angle, and nozzle outlet diameter were selected as design factors having an influence on the flow characteristics, and numerical analysis was conducted for these factors. As the inlet velocity is high and the nozzle outlet diameter is small, the pressure and velocity of the injected flow are high. In the case of the nozzle inflow angle, the variation of flow characteristics according to angle was slight, but the highest pressure and velocity were found at $15^{\circ}$. In addition, the possibility of chip elimination by the injected flow was analyzed on the basis of the numerical results.

축소 노즐에서의 슬롯 막냉각 열전달 특성에 관한 연구

  • 조용일;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.33-33
    • /
    • 2000
  • 고온의 연소가스로부터 노즐 표면을 보호하기 위하여 슬롯을 통하여 냉각 유체를 분사하는 슬롯 막냉각에 대하여 연구하였다. 냉각효율 및 열전달 특성은 주유동과 2차 유동의 분사율에 따라 크게 달라지며, 형상변화 및 유동가속에 의해서도 냉각 효과의 변화를 가져오게 된다. 따라서 본 연구에서는 실험을 통하여 면적비가 16:1인 축소노즐에서 압축성 효과를 배제할 수 있는 유동속도 범위 내에서 분사율 변화(0.5 $\leq$ M $\leq$ 3.0)에 따른 슬롯 막냉각 열전달 특성을 고찰하고, 평판 슬롯 막냉각 경험식의 결과와 비교하였으며, 수치해석을 통하여 축소노즐과 원형관에서의 냉각효율 및 열전달 특성을 비교함으로서 이를 검증하였다. 축소노즐에서의 슬롯 막냉각 열전달 특성은 단열벽면조건을 형성하여 노즐 표면을 따라 설치된 열전대를 이용하여 측정하였다. 그 결과 상대적으로 낮은 분사율(M=0.5, 1.0)에서 분사율 증가에 따른 냉각효율의 증가가 크게 나타났으며, 분사율이 높아짐(M $\geq$ 2.0)에 따라 냉각효율의 증가폭이 점점 감소하고, 일정 분사율 이상에서는 냉각 효율의 증가가 크게 둔화되었다. 분사율이 낮을 경우 평판 슬롯 막냉각 경험식으로 주어진 결과보다 상류에서는 높으나 하류로 진행하면 비슷한 냉각효율을 보였고, 분사율이 높은 경우 평판보다 전 범위에서 약간 높은 냉각효율을 나타냈다. 수치해석 결과에서는 분사율이 낮을 경우 축소노즐의 냉각효율이 원형관에서의 냉각효율 보다 낮거나 비슷하게 나타났으며, 분사율이 높아짐에 따라 축소노즐에서의 냉각효율이 오히려 높아지는 것으로 나타났다.타내었다. 액체 제트의 속도는 처음에는 일정하게 유지되다가 운동량을 보존하기 위해 가스로부터 운동량을 받아 점차 가속되어지는 것으로 나타났다.본 규격은 키, 총장, 어깨길이, 등길이, 머리길이, 머리둘레, 진동둘레, 목둘레, 가슴둘레, 허리둘레, 배둘레, 엉덩이둘레, 앞품, 뒤품, drop치를 포함하고 있고, 각 규격에서 호칭간 치수 간격도 함께 제시하고 있다. 본 연구 결과에서 보듯, 현행 8규격의 무진복의 각 호칭간 적정 허용범위를 고려해 합리적인 치수체계를 정립한다면 치수에 대한 적합도가 상당히 증가할 뿐 아니라 생산비용도 상당히 감축할 것으로 생각된다.나타났다. 4) 호감적 서비스능력 차원에서 세 독립변수간에 유의한 3원 상호작용이 존재하는 것으로 나타나( $F_{2,228}$=15.62, P<.001) 20대에 적합한 의복 착용시( $F_{2,228}$=3.98, P<.05)와 60대에 적합한 의복 착용시( $F_{2,228}$=16.55, P<.001) 점포유형과 격식차림간에는 유의한 상호작용이 존재하는 것으로 나타났다. 5) 호감을 구성하는 세 요인들이 구매의도에 미치는 영향을 조사한 결과 호감적 인상차원은 29%(P<.001), 호감적 서비스능력차원은 6%(P<.001)의 구매의도를 설명해 주는 것으로 나타났다. 본 연구결과 노년 소비자에게 호감을 주는 판매원의 외모는 구매의도에 영향을 주어 실버의류산업의 이익증대와 밀접한 연관을 갖는 서비스품질의 중요한 요인으로 밝혀졌다.중요한 요인으로 밝혀졌다.로운 단백질 EPSPS가 다른 여러 식물에 이미 존재하고 있는 단백질로서 우리가 이미 이러

  • PDF

Experimental Analysis on Hydroplaning Inhibition by Air Jetting Devices (공기 분사 장치에 의한 수막 형성 억제 특성 분석)

  • Ko, Kwangsoo;Moon, Jungwoo;Yoon, Hyungon;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • 매년 장마철에는 수막현상으로 인한 교통사고가 빈번하게 발생한다. 본 연구는 수막 형성 억제를 위해 타이어 앞부분에 설치되는 공기 분사 장치의 성능을 평가하는 것으로서, 공기 분사에 의한 수막 형성 억제를 모사할 수 있는 실험 장치를 제작하고, 수막 형성 억제 과정을 가시화하여 공기 분사 장치의 성능을 파악하고자 한다. 실험 변수로서 노즐의 형상 3가지와 수막에 대한 분사각 3가지에 대해 상세히 그 영향을 조사하였으며, 그 결과 분사각은 10도(지면에 대해서는 80도), 노즐 형상은 일자형일 때 수막 억제 효과가 가장 큰 것으로 파악되었다.

Spray characteristics on mixing region scale of twin fluid atomizer (이류체 분사노즐의 혼합영역 형상에 따른 분무특성)

  • 김병문;김혁주;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2147-2159
    • /
    • 1991
  • The effects of principal dimensions of internal mixing twin-fluid atomized and operating conditions on the atomizing characteristics are experimentally investigated. The tests are conducted over the wide range of air/liquid ratio to predict influences of the diameter and length of nozzle, contacting angle between air and liquid in the mixing chamber, and air orifice diameter on the mean drop size(SMD), spray angle, distribution of drop size, and spray dispersion, And also, initial distribution of liquid column by air stream within the mixing chamber are observed through the transparent nozzles. A He-Ne laser particle sizer(MALVERN Model 2604) was used to measure the Sauter.s mean diameter( $D_{321}$) and droplet sizes distribution. In this experiment the air/liquid ratio, mixing length and nozzle diameter have a great influence on SMD, spray angle, droplet sizes distribution and spray dispersion.

Effect of Nozzle Shape and Injection Pressure on Performance of Hybrid Nozzle (노즐 형상 및 분사 압력이 하이브리드 노즐 성능에 미치는 영향 연구)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.74-79
    • /
    • 2017
  • The fire extinguishing performance of hybrid nozzle systems is improved by injecting an extinguishing agent concentrically into the target site and, in this study, water mist is used as a water curtain to confine the droplets of the agent. In this study, we numerically investigated the effect of the foundation angle and injection pressure on the performance of a hybrid nozzle by evaluating the mean radius of the volume fractions of the agent and water mists. An experiment involving a water mist nozzle was carried out to validate the numerical method and then the droplet behaviors, e.g., stochastic collision, coalescence and breakup, were calculated with 2-way interaction Discrete Particle Modeling (DPM) in the steady state for the hybrid nozzle system. The mean radius of the water mists increased by about 40 %, whereas that of the agent decreased by about 21 %, when the injection pressure was increased from 30 bar to 60 bar. In addition, the mean radius of the agent increased by about 24 % as the foundation angle of the hybrid nozzle head increased from $30^{\circ}$ to $60^{\circ}$. As a result, it can be inferred that the injection angle and pressure are important factors for hybrid water mist designs.

Effect of injection pressure on the atomization characteristics of a liquid sheet-type swirl injector for Urea-SCR system (Urea-SCR시스템 액막형 선회분사기의 분사압력변화에 따른 무특성에 관한 연구)

  • Kim, Duckjin;Yang, Donguk;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.510-519
    • /
    • 2013
  • In this study, the spray characteristics of a pressure swirl atomizer classified into a liquid sheet-type swirl nozzle for Urea-SCR system were investigated experimentally with the variation of injection pressure. The length to diameter ratio ($l_o/d$) of the nozzle was 3.1, and the swirler was set inside the nozzle tip to give injecting fluid angular momentum. The injection duration of the nozzle was controlled by PWM (pulse width modulation) modes. The development processes of the spray were imaged by a 2-D PIV system, and the change of spray angle was measured. The atomization characteristics, including axial velocity and SMD, were measured using a 2-D PDA system with the injection pressures at room temperature and ambient pressure conditions. As the experimental results, the injection pressure had a significant impact on the spray structure showing a different shape around the spray leading edge, and the smaller SMD was observed with increasing injection pressures, which was similar to that of the previous work.

Development on the Auto Showering system of Bed type for Elderly (고령자를 위한 와상형 자동 샤워링 시스템 개발)

  • Hong, Jae-Soo;Kim, Jong-Hyun;Chun, Keyoung-Jin;Lee, Young-Sig
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.318-321
    • /
    • 2011
  • 한국은 급격한 고령화가 진행 중에 있다. 세계적으로도 유례가 없는 급격한 고령화에 노인시설 및 병원에서 생활하는 고령자의 수 역시 증가하고 있는 추세이다. 시설이나 병원에서 고령자의 샤워수발은 수발자에게는 매우 힘든 노동이 되고 있다. 따라서 본 연구에서는 샤워 수발자의 불편함을 해소할 수 있는 와상형 자동 샤워링 시스템을 개발하는 것을 연구목적으로 한다. 와상형 자동 샤워링 시스템을 개발하기 위하여 본 연구에서는 기존 국외제품의 노즐위치 문제점을 분석하고, 수발자의 수발행위가 최적화될 수 있는 최적노즐위치 구현을 위한 샤워링 테스트, 샤워링시뮬레이션 등을 사용하여 최적노즐위치를 구현하였다. 또한 적은 노즐 수로 넓은 범위를 효과적으로 세정할 수 있는 스윙노즐을 개발하여 시제품에 적용하였다. 샤워링 테스트의 노즐위치 최적화결과를 샤워링 시뮬레이션에 적용하여 노즐위치 및 분사각의 최적화를 수행하였고, 이를 실제 시제품 설계에 적용하였다. 본 연구에서는 와상형 샤워링 시스템의 개발에 있어 사용자의 수발부담을 경감할 수 있는 가장 중요한 설계요소를 노즐위치 및 분사각으로 정의하고, 노즐위치 및 분사각도의 최적화를 중심으로 와상형 자동샤워링 시스템 개발 연구를 수행하였다. 본 연구의 사용자 중심 제품개발과정은 앞으로 다양한 고령친화제품을 개발하는데 있어 수발자의 부담을 감소시키고, 고령사용자의 자립생활을 지원하는데 있어 적용 가능할 것으로 사료된다.

  • PDF

2차 유동 분사에 의한 추력 방향 제어(TVC)에 관한 2차원 및 3차원 유동해석

  • 오대환;구상모;손창현;이중원
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.15-15
    • /
    • 1999
  • 2차 유동 분사에 의한 추력 방향 제어 방법은 복잡한 기계적 작동장치와 이에 따른 무게의 증가를 배제할 수 있다. 본 연구에서는 유동 해석을 통하여 2차원 및 3차원 초음속 수축-팽창 노즐 유동에 2차 유동을 분사하여, 2차 유동의 분사 위치, 분사 유량 및 분사 각도 등이 추력의 방향 및 크기에 미치는 영향을 밝혀 추력 방향 제어를 위한 최적의 2차 분사 조건을 제시하였다. 유동 해석 결과 2차 유동의 분사 위치는 생성된 경가 충격파가 노즐 출구까지 분포되는 지점이 최대 전향각과 횡추력을 가지는 분사위치임을 알 수 있었고, 분사 각도는 주 유동의 역방향으로 분사하는 것이 수직방향으로 분사하는 것보다 더 큰 전향각을 얻을 수 있었다. 또한 2차원의 경우보다 3차원 유동에서 큰 전향각이 생김을 알 수 있었다.

  • PDF

Performance Analysis of Secondary Gas Injection for a Conical Rocket Nozzle TVC(II) (2차 가스분사에 의한 원추형 로켓노즐 추력벡터제어 성능해석 (II))

  • Song, Bong-Ha;Ko, Hyun;Yoon, Woong-Sup;Lee, Sang-Kil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.18-25
    • /
    • 2001
  • The results of systematic numerical experiments of secondary gas injection thrust vector control are presented. The effects of secondary injection system such as injection location and nozzle divergent cone angle onto the overall performance parameters such as thrust ratio, specific impulse ratio and axial thrust augmentation, are investigated. Complex nozzle exhaust flows induced by the secondary jet penetration is numerically analyzed by solving unsteady three-dimensional Reynolds-averaged Navier-Stokes equations with Baldwin-Lomax turbulence model for closure. Numerical simulations compared with the experiments of secondary air injection into the rocket nozzle of $9.6^{\cire}$ divergent half angle showed good agreement. The results obtained in terms of overall performance parameters showed that locating the secondary injection orifice further downstream of primary nozzle ensures the prevention of occurrence of reflected shock wave, therefore is suitable for efficient and stable thrust vectoring over a wide range of use.

  • PDF