• Title/Summary/Keyword: 분무 화염

Search Result 128, Processing Time 0.027 seconds

Flow Characteristics of Propane Premixed Flame on AC Electric Field (교류 전기장 인가에 따른 프로판 예혼합 화염의 유동 특성)

  • Boyun Kim;Minseok Kim;Taehun Kim;Ilsong Kweon;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • This study investigates the flow characteristics of propane-air premixed flames on AC electric field using the Schlieren method. A voltage was applied to the ring electrode and the burner was grounded to form an electric field, and the applied voltage was fixed at 16 kV (Vpp). Results show that under the application of AC electric fields, flow around the flame oscillated only at frequencies below 50 Hz, and no oscillation was observed above this frequency range. Flame height oscillated with frequency in the range of 25 to 300 Hz, with frequency doubling observed in the range of 25 to 150 Hz. The flammability limit increased with frequency up to 250 Hz, but in the high-frequency range above 250 Hz, the flammability limit did not increased and converged.

Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire (분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향)

  • Kim, Ho-Young;Oh, Sang-Youp;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

Synthesis of $LiCoO_{2}$ Nanoparticles From Leach Liquor of Lithium Ion Battery Wastes by Flame Spray Pyrolysis

  • Lee Churl Kyoung;Chang Hankwon;Jang Hee Dong;Sohn Jeong-Soo
    • Resources Recycling
    • /
    • v.14 no.6 s.68
    • /
    • pp.37-43
    • /
    • 2005
  • [ $LiCoO_{2}$ ] nanoparticles were synthesized from leach liquor of lithium ion battery waste using flame spray pyrolysis. Electrode Materials containing lithium and cobalt could be concentrated with thermal and mechanical treatment. After dissolution of used cathode materials of the lithium battery with nitric acid, the molar ratio of Li/Co in the leach liquor was adjusted at 1.0 by adding a fresh $LiNO_{3}$ solution. The nanoparticles synthesized by the flame spray pyrolysis showed clear crystallinity and were nearly spherical, and their average primary particle diameters ranged from 11 to 35 nm. The average particle diameter increased with an increase in the molar concentration of the precursor. Raising the maximum flame temperature by controlling the gas flow rates also led to an increase in the average diameter of the particles. The $LiCoO_{2}$ powder was proved to have good characteristics as cathode active materials in charge/discharge capacity and cyclic performance.

Effect of Injection Pressure and Injection Timing on Spray and Flame Characteristics of Spray-Guided Direct-Injection Spark-Ignition Engine under Lean Stratified Combustion Operation (성층희박연소 운전조건에서 분사시기에 따른 분무유도식 직접분사 가솔린엔진의 분무 및 화염특성)

  • Oh, Heechang;Lee, Minsuk;Park, Jungseo;Bae, hoongsik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.221-228
    • /
    • 2013
  • An experimental study was carried out to investigate the effects of the injection timing on the spray and combustion characteristics in a spray-guided direct-injection spark-ignition (DISI) engine under lean stratified operation. An in-cylinder pressure analysis, exhaust emissions measurement, and visualization of the spray and combustion were employed in this study. The combustion in a stratified DISI engine was found to have both lean premixed and diffusion controlled flame combustion characteristics. The injection timing condition corresponding to the stratified mixture characteristics was verified to be a dominant factor for these flame characteristics. For the early injection timing, a non-luminous blue flame and low combustion efficiency were observed as a result of the lean homogeneous mixture formation. On the other hand, a luminous sooting flame was shown at the late injection timing because of an under-mixed mixture formation. In addition, the smoke emission and incomplete combustion products were increased at the late injection timing as a result of the increased locally rich area. On the other hand, the NOx emissions decreased and IMEP increased as the injection timing retarded. The combustion phasing produced by the injection timing was verified as the reason for this observation.

Evaluation of Combustion Mechanism of Droplet Cluster in Premixed Spray Flame by Simultaneous Time-Series Measurement (동시 시계열 계측에 의한 예혼합 분무화염 내 유적군 연소기구의 평가)

  • Hwang, Seung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.442-448
    • /
    • 2009
  • To evaluate the combustion mechanism of each droplet cluster downstream of the premixed spray flame, the simultaneous time-series measurements were conducted by using optical measurement system consisting of laser tomography, multi-color integrated Cassegrain receiving optics (MICRO) and phase Doppler anemometer (PDA). Furthermore, the group combustion number of droplet cluster was estimated experimentally, and the combustion mechanism of droplet cluster was examined applying the theoretical analysis. The group combustion number, $G_c$, was experimentally estimated about all droplet cluster verified by planar images, and it was classified into the internal group combustion mode and the external group combustion mode according to the theoretical analysis. It is found that there are cases in which the group combustion number estimated experimentally for droplet cluster agree or disagree with the classification by theoretical analysis. The reason of disagreement is considered due to that the group combustion number was only estimated by the geometrical arrangement of droplets in cluster, and that the actual phenomenon is three-dimensional but the measurement system is two-dimensional.

A study on the spray and flame by optically accessible D.I. diesel engine : analysis by Schlieren method and diffused background illumination method (가시용 직분식 디젤기관의 분무와 화염에 관한 연구)

  • 안수길;이덕보;라진홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.9-23
    • /
    • 1995
  • To analyze the spray and flame in D.I. diesel engine, the visualizing methods by schlieren photograph and diffused background illumination photograph with high speed camera are applied to optically accessible D.I.diesel engine. Wcaporating spray, spray droplets and brightness flame are taken with high speed camera by visuallizing method in accordance with various suction air temperature and injection time. The spray and flame image on the film was analyzed by image analyzer. The optically accessible D.I. diesel engine had the similar pressure characteristic to the real D.I. diesel engine. Experimental results showed that shadow areas of the evaporating spray were extended at higher suction air temperature, spray droplets had a max. Penetration length and their penetrating patterns were dependent on the surrounding gas temperature, and flame size after ignition was largely governed by the evaporated fuel quantity at ignition point and by the surrounding gas condition due to piston motion.

  • PDF

Numerical Study on the Characteristics of Spray Combustion Processes in the DME and n-heptane Fueled Diesel-like Engine Conditions (DME 및 n-Heptane 연료의 디젤엔진 조건에서 분무연소특성 해석)

  • Yu, Yong-Wook;Suk, Jun-Ho;Lee, Sang-Kil;Kim, Yong-Mo
    • Journal of ILASS-Korea
    • /
    • v.13 no.2
    • /
    • pp.91-98
    • /
    • 2008
  • In the present study, in order to understand the overall spray combustion characteristics of DME fuel as well as to identify the distinctive differences of DME combustion processes against the conventional hydrocarbon liquid fuels, the sequence of the comparative analysis have been systematically made for DME and n-heptane liquid fuels. To realistically represent the physical processes involved in the spray combustion, this studyemploys the hybrid breakup model, the stochastic droplet tracking model, collision model, high-pressure evaporation model, and transient flamelet model with detailed chemistry. Based on numerical results, the detailed discussions are made in terms of the autoignition, spray combustion processes, flame structure, and turbulence-chemistry interaction in the n-heptane and DME fueled spray combustion processes.

  • PDF

Effect of Water on Continuos Spray and Flame in Emulsified Fuel made by Ultrasonic Energy (초음파 에너지로 제조된 유화연료의 수액이 분무 및 화염에 미치는 영향)

  • Lee, Seung-Jin;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 2005
  • To investigate spray and combustion of emulsified fuel of W/O type, we mixed water with light oil by using ultrasonic energy adding system. We measured the SMD of sprayed droplet to find atomization characteristics of emulsified fuel with using the Malvern 2600D system. Major parameters are the weight ratio of water($0{\sim}30%$ by 10%) in emulsified fuel injection pressure(lobar), and the measurement distance($10{\sim}100mm$ by 10mm). Combustion visualizing system is made up commonly used boiler system and digital camera 1/500s to investigate combustion phenomena. As a result, the more water contents increased, the more SMD increased. The water particle of emulsified fuel made short flame in continuos spray combustion phenomena because of micro explosion.

  • PDF