• Title/Summary/Keyword: 분극처리

Search Result 144, Processing Time 0.035 seconds

Evaluation of water permeability of forward osmosis membranes using osmotically driven membrane test (랩스케일 정삼투실험을 통한 정삼투막의 수투과도 평가)

  • Lee, Junseo;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.417-425
    • /
    • 2016
  • Desalination is a key technology to overcome water shortage problem in a near future. High energy consumption is an Achilles' heel in desalination technology. Osmotically driven membrane processes like forward osmosis(FO) was introduced to address this energy issue. Characterizing membrane properties such as water permeability(A), salt permeability(B), and the resistance to salt diffusion within the support layer($K_{ICP}$) are very important to predict the performance of scaled-up FO processes. Currently, most of researches reported that the water permeability of FO membrane was measured by reverse osmosis(RO) type test. Permeating direction of RO and FO are different and RO test needs hydraulic pressure so that several problems can be occurred(i.e. membrane deformation, compaction and effect of concentration polarization). This study focuses on measuring water permeability of FO membrane by FO type test results in various experimental conditions. A statistical approach was developed to evaluate the three FO membrane properties(A, B, and $K_{ICP}$) and it predicted test result by the internal and external concentration polarization model.

Change in the Fractrue Toughness of Pb (Zr, Ti)$O_3$ Ceramics before and after Poling Treatment (분극처리 전후의 Pb(Zr, Ti)$O_3$ 세라믹스의 파괴인성의 변화)

  • Tae, Won-Pil;Kim, Song-Lee
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.546-552
    • /
    • 1993
  • 본 연구에서는 입계의 성질을 이용한 PTCR 재료에 입계 modifier로서 $Bi_{2}$$O_{3}$와 BN을 첨가하고 입계의 미세구조와 결함농도를 변화시켜 이에 따른 소결 및 전기적 특성변화를 TMA, XRD, 복합 임피던스방법 등을 이용하여 해석하였다. 실험 결과 Y이 도우핑된 BaT$iO_{3}$ PTCR 재료에 $Bi_{2}$$O_{3}$를 첨가하였을때 약 0.1mol%까지 고용이 되는 것으로 밝혀졌다. $Bi_{2}$$O_{3}$를 고용한계 이하로 첨가시에는 생성되는 vacancy등의 결함으로 말미암아 Y-BaT$iO_{3}$의 치밀화가 촉진되었으나, 그 이상 첨가하면 치밀화 뿐만 아니라 결정립 성장도 억제되었다.$Bi_{2}$$O_{3}$ 결정립 내부에 Ba와 Ti vacancy가 동시에 생길 수 있어 고온저항이 높아짐을 알 수 있었다. BN은 BaT$iO_{3}$에 고용이 되지 않는 것으로 밝혀졌으며 $B_{2}$O/wub/3를 주성분으로한 액상형성으로 인하여 저온에서의 급격한 치밀화가 관찰되었다. 또 Ba-Y-Ti-B-O의 비정질 상이 tripie junction에 존재함으로서 상온저항이 크게 변화하였으며, PTCR jump도 높아졌다.

  • PDF

Cryo-Electron Microscopy of Microstructures of Emulsions (동결처리 전자현미경을 이용한 에멀젼 미세구조 분석)

  • 이은주;강윤석;윤명석;랑문정
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.1
    • /
    • pp.53-58
    • /
    • 2004
  • In this study, we describe the application of electron microscopes that incorporate freeze treatments or cryo systems to achieve the characterization of the microstuctures of emulsions. We confirmed that the preparations of freezing replica method and with cryo systems were useful to clarify the microstuctures of the emulsions. This methodology will be able to contribute to understanding the relation between microstuctures and rheology of emulsions.

합금 600 및 합금 690의 가성 응력 부식 균열에 미치는 합금 원소 및 부식 조건의 영향

  • 김택준;박용수;김영식;국일현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.481-486
    • /
    • 1996
  • 원자력 발전소의 증기 발생기 전열관으로 사용되는 합금 600MA는 미세 구조에 관계없이 가성 용액에서 입계 균열이 발생한다. 본 연구에서는 합금 600 2종과 합금 690 2종의 이음매없는 관 및 진공 용해한 합금 690M 2종의 MA 및 TT재에 대한 부식 조건의 변화에 응력 부식 균열 특성을 일정연신율법(CERT) 및 C-ring법으로 평가하였다. 가성 응력 부식 균열 저항성에 미치는 TT처리의 효과는 용액 조건에 관계없이 TT처리를 행하게 되면 응력 부식 균열에 대한 저항성이 증가하는 것으로 나타났으며, 분극 저항성과는 직접적인 관계가 나타나지 않고 다른 미세 조직 등에 의한 영향을 더 크게 받고 있는 것으로 판단된다. 가성 용액에서의 응력 부식 균열 저항성에 미치는 SO$_4$$^{=}$ 이온의 첨가 효과는 TT처리의 유무에 관계없이 응력 부식 균열 저항성을 크게 감소시키고 있다. 한편 합금 690의 가성 응력부식 균열 저항성에 미치는 Mo의 효과는 Mo이 첨가될수록 응력 부식 균열 저항성이 증가하는 것으로 나타났다.

  • PDF

Characteristics of Flux Decline in Forward Osmosis Process for Asymmetric Cellulose Membrane (정삼투 공정에 있어 비대칭 셀룰로오즈 막의 투과유속 감소특성)

  • Lee, Keun-Woo;Han, Myeong-Jin;Nam, Suk-Tae
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.328-334
    • /
    • 2014
  • This study examined the effect of concentration polarization on permeate flux in forward osmosis (FO) membrane process for saline and sucrose solution. The reduction in permeate flux during the FO membrane process is largely due to the formation of concentration polarization on membrane surfaces. The flux reduction due to internal concentration polarization formed on the porous support layer was larger than that due to the external concentration polarization on the active membrane surface. Water permeate flux through the FO membrane increased nonlinearly with the increase in osmotic pressure. The water permeability coefficient was $1.8081{\times}10^{-7}m/s{\cdot}atm$ for draw solution on active layer (DS-AL) mode and $1.0957{\times}10^{-7}m/s{\cdot}atm$ for draw solution on support layer (DS-SL) mode in NaCl solution system. The corresponding membrane resistance was $5.5306{\times}10^6$ and $9.1266{\times}10^6s{\cdot}atm/m$, respectively. With respect to the sucrose solution, the permeate flux for DS-AL mode was 1.33~1.90 times higher than that for DS-SL mode. The corresponding variation in the permeation flux (J) due to osmotic pressure (${\pi}$) would be expressed as $J=-0.0177+0.4506{\pi}-0.0032{\pi}^2$ for the forward and $J=0.0948+0.3292{\pi}-0.0037{\pi}^2$ for the latter.

A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process (질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon;Song, Su-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • This study was performed under four operational conditions for nitrogen removal in metal finishing wastewater. The conditions include electrode gap, reducing agent, the recycling of treated wastewater in 1st step and the simultaneous treatment of nitrate and other materials. Result showed that the removal efficiency of $NO_3{^-}-N$ was highest at the electrode gap of 10 mm. As the electrode gap was shorter than 10 mm, the removal efficiency of $NO_3{^-}-N$ decreased due to increasing in concentration polarization on electrode. And, in case that the electrode gap was longer than 10 mm, the removal efficiency of $NO_3{^-}-N$ increased with an increase in energy consumption. Because hydrogen ions are consumed when nitrate is reduced, reducing reaction of nitrate was effected more in acid solution. As 1.2 excess amount of zinc was injected, the removal efficiency of $NO_3{^-}-N$ increased due to increasing in amount of reaction with nitrate. As the effluent from 1st step in the reactor was recycled into the 1st step, the removal efficiency of $NO_3{^-}-N$ increased. Because the zinc were detached from the cathode and concentration-polarization was decreased due to formation of turbulence in the reactor. The presence of $NH_4{^+}-N$ did not affect the removal efficiency of $NO_3{^-}-N$ but the addition of heavy metal decreased the removal efficiency of $NO_3{^-}-N$. As chlorine is enough in wastewater, the simultaneous treatment of nitrate and ammonia nitrogen may be possible. The problem that heavy metal decrease the removal efficiency of $NO_3{^-}-N$ may be solved by increasing current density or using front step of electrochemical process for heavy metal removal.

Experimental Study on the Backflushing for Ultrafiltration Treatment of Alkaline Cleaner Containing Cutting Oils (오일 함유 세척수의 한외여과 처리에서의 역세척에 관한 실험연구)

  • 김종표;정명석;김재진;정건용;전성덕
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.94-101
    • /
    • 1998
  • The oil separation is effectively performed from the oil containing alkaline cleaner solution by using a backflushed ultrafiltration system, where hollow fibers commercially made by polyacrylonitrile copolymer are bundled. Backflushing to reduce membrane fouling during crossflow ultrafiltration is investigated. Experimental observations allow us to understand the behavior of permeate flux according to the relative operating conditions, and determine the optimum condition of normal operation and backflushing. The maximum improvement of net permeate flux owing to backflushing was found to be about 23 % with the condition of 10 min/40 sec for the cycle of normal/backflushing operations. Note that, however, the maintenance of stable permeate flux is lost as the duration of normal operation is increased. The permeate flux depends on both the backflushing pressure and the feed flow rate. It is obvious that there is a critical velocity of feed flow, in which permeate flux is practically independent of backflushing pressure. Above this critical value, the permeate flux is proportional to an appropriate power of the backflushing pressure, $\Delta P_{back}^n$, where exponent n is enhanced with increasing feed velocity.

  • PDF

Study on the Improvement of Nitrate Removal Efficiency in Multi-Step Electro-chemical Process (전기화학적공정에서 질산성질소 제거효율 향상에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.155-160
    • /
    • 2008
  • In this study, the nitrate removal efficiency was examined under a variety of operating conditions, such as different doses of the reducing agent, different electrode types, different HRTs(hydraulic retention times), and different current densities, using the multistep electrochemical process. The nitrate removal efficiency increased and the input energy decreased when the reducing agent was used, and almost no difference was found between the electrode types in terms of their nitrate removal efficiency and current efficiency. So that the Zn reducing agent could be recovered, though, the B-type electrode was chosen(step 1: Pt-Zn; step 2: Pt-Zn; step 3: Pt-Zn; step 4: Pt-Zn). HRT experiments were carried out on constant electric current density unrelated HRTs and various electric current density related HRTs: the constant amount of electric current per unit volume. As a result, HRT and the electric current density caused concentration polarization and the lack of an applied current. That is to say,the lower the HRT, the greater the decrease in concentration polarization and in the amount of applied current per unit volume. Therefore, optimal conditions were found through the experiments that were conducted on HRT and electric current density. When a spacer was installed in the process, the nitrate removal efficiency and energy efficiency increased even more because the diffusion likewise increased.

Effects of Metalized Al-2%Zn Layer on the Corrosion Behavior of Al 5083 Alloy (Al 5083 합금의 부식거동에 미치는 Al-2%Zn 용사 코팅층의 영향)

  • 김용철;김영근;이성민;고영태
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.2-2
    • /
    • 1999
  • 금속재료의 표면 특성을 높이기 위해서 여러 표면처리 방법들이 사용되어져 오고 있다. 그 중 용사법에 의한 코팅방법이 최근의 현저한 기술적인 진보와 새로운 용사재료의 개발 등에 의해 여러 분야에 널리 응흉되고 있다. 일반적으로 이 용사법에 의한 코팅층은 다리, 선박 등의 대형 구조물에 대한 내식성 향상뿐만 아니라 자동차 및 항공기 부품, 핵 반응기 등의 코팅부에 널리 이용되고 였다. 특히 해수분위기에서 주로 사용되는 설비의 내식성을 향상시킬 목적으로 사용되 는 알루마늄 및 아연 합금의 용사 코팅층은 대부분의 경우 건조한 분위기보다는 수분이 많은 수용액 환경 하에서 사용되므로, 사용 환경 중에서 용사피막의 내식성을 조사하는 연구가 요구되고 있다. 사용되는 환경하에서의 침지시험에 의한 방법도 중요하지만, 가속화된 전기화학측정에 의한 방법 또한 이용된다. 열용사법에 의한 코팅층의 전기화학적 특성을 알아보기 위해서 3.5 % NaCI 수용액 내에서 AI 5 5083 모재와 Al-2%Zn 합금의 용사 코팅층 각각에 대한, 그리고 AI 5083 모재 위 AI-2%Zn 용사층이 코팅된 경우에 대한 분극거동과 침지시간에 따른 부식전위 및 분극저항성의 특성변화, 표면의 임피던스특성 변화 등을 측정하였다. 이 결과 모재에 대한 코팅층의 희생양극성올 판단할 수 있고, 모재/코팅 사스템의 분극거동은 혼성전위이론(mixed-potential theory)에 의해 결정되었다. 용사 코팅층이 박리되어 모재가 일부 드러난 경우를 모사한 시험편올 제작하고, 시험편 표면의 각 위치에 따라 부식전위 분포를 측정하였다. 그리고 측정 데이터를 기초로 표면의 상태변화를 모사하여 용사코팅에 의한 표면에서의 방식전위분포를 시율레이션하였다. 이와 같은 표면에서의 방식전위분포 해석을 통하여, 코팅층의 희생양극성에 의한 모재의 방식범위를 판단할 수 있다.의 비저 항을 갖는 철 박막에서도 99.9% 순도의 철을 타켓으로 하여 증착된 막은 일반 저탄소 강을 타켓으로 하여 증착된 막보다 훨씬 낮은 부식속도를 보였다.TEX>$He/O_2/Ar/N_2$의 gas를 사용 한 atmospheric pressure plasma cleaning 과 $Ar/O_2$의 gas를 사용한 ICP cleaning에서 이 차전자방출계수(SEEC)가 약 1.5~2.5배 증가된 것을 알 수 있었다. 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorne

  • PDF

Influence of the Mesophyll on the Change of electrical Potential Difference of Guard Cells Induced by Red-light and CO2 in Commelina communis L. and Tradescantia virginiana L. (닭의장풀과 자주달개비에서 적색광과 이산화탄소에 의해 유도된 공변세포의 전위차 변화에 미치는 엽육세포의 영향)

  • 이준상
    • Journal of Plant Biology
    • /
    • v.36 no.4
    • /
    • pp.383-389
    • /
    • 1993
  • The effects of light and $CO_2$ on the electrophysiological characteristics of guard cells in the intact leaf and in the detached epidermis have been investigated. Guard cells in intact leaves showed the membrane hyperpolarization in response to light. The biggest induced change of the membrane potential difference (PD) in the guard cells of the intact leaf was 13 m V by light and 42 mV by $CO_2$ in Commelina communis. Similar results were obtained with Tradescantia virginiana. However, there were no changes of membrane PD in detached epidermis. In order to determine the influence of the mesophyll on the changes of membrane PD, infiltration of the mesophyll cells with photosynthetic inhibitors was performed. In CCCP infiltrated leaf discs the guard cell membrane was depolarized slightly by red-light and hyperpolarized by $CO_2$, but in leaf discs infiltrated with DCCD and DCMU the guard cell membrane was hyperpolrized by both red-light and $CO_2$ as the control leaf discs. In azide infiltrated leaf discs the guard cell membrane showed no response to light and there was a much reduced membrane hyperpolarization by $CO_2$ compared to other responses. It was likely that azide caused leaf damage and the activity of cell metabolism was decreased greatly, resulting in small membrane PD changes by $CO_2$ and no changes by redlight. Therefore, it can be suggested that red light was sensed by the mesophyll and the light induced guard cell membrane hyperpolarization was related to energy produced by cyclic-photophosphorylation, but ${CO_2}-induced$ guard cell membrane hyperpolarization was not related to photosynthesis. Alkalisation of the vacuole was observed when the intact leaf was exposed to $CO_2$, indicating that membrane hyperpolarization was mainly the result of proton efflux.efflux.

  • PDF