• Title/Summary/Keyword: 분광 광도법

Search Result 54, Processing Time 0.022 seconds

Simultaneous Spectrophotometric Determination of Copper, Nickel, and Zinc Using 1-(2-Thiazolylazo)-2-Naphthol in the Presence of Triton X-100 Using Chemometric Methods (화학계량학적 방법을 사용한 Triton X-100이 함유된 1-(2-Thiazolylazo)-2-Naphthol을 사용한 구리, 니켈과 아연의 동시 분광광도법적 정량)

  • Low, Kah Hin;Zain, Sharifuddin Md.;Abas, Mhd. Radzi;Misran, Misni;Mohd, Mustafa Ali
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.717-726
    • /
    • 2009
  • Multivariate models were developed for the simultaneous spectrophotometric determination of copper (II), nickel (II) and zinc (II) in water with 1-(2-thiazolylazo)-2-naphthol as chromogenic reagent in the presence of Triton X-100. To overcome the drawback of spectral interferences, principal component regression (PCR) and partial least square (PLS) multivariate calibration approaches were applied. Performances were validated with several test sets, and their results were then compared. In general, no significant difference in analytical performance between PLS and PCR models. The root mean square error of prediction (RMSEP) using three components for $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ were 0.018, 0.010, 0.011 ppm, respectively. Figures of merit such as sensitivity, analytical sensitivity, limit of detection (LOD) were also estimated. High reliability was achieved when the proposed procedure was applied to simultaneous determination of $Cu^{2+}$, $Ni^{2+}$ and $Zn^{2+}$ in synthetic mixture and tap water.

Accuracy and Precision of Spectrophotometric Measurement of Clay Content in Soils (분광광도계를 이용한 점토함량 분석의 정확성 및 정밀성 평가)

  • Park, Soon-Nam;Kim, Kye-Hoon;Kang, Ji-Young
    • Applied Biological Chemistry
    • /
    • v.49 no.2
    • /
    • pp.153-157
    • /
    • 2006
  • Accuracy and precision of the spectrophotometeric analysis of clay content in soils were estimated by comparison with the conventional pipet method. Clay contents in 25 soil samples of various physico-chemical properties including texture were determined by spectrophotometry and pipet methods, and the two sets of data an clay content were compared by several statistical analyses. The correlation between clay contents determined by spectrophotometry and pipet methods was highly significant. The regression coefficient was $0.98^{**}$ and the slope of regression equation was close to 1.0. The standard deviation and CV of clay contents measured by spectorphotometry were smaller than those found in the data of clay contents obtained by pipet method. In conclusion, compared to the conventional pipet method, spectrophotometry was a rapid, convenient, accurate and precise method for the measurement of clay content in soils.

Ultraviolet Spectrophotometric Analysis of 2-Aminonaphtalene Sulfonic Acids (2 - 아미노나프탈렌술폰산류의 자외선분광 광도법에 의한 분석)

  • Sohn, Joo-Hwan;Kim, Joo-Youn
    • Journal of the Korean Applied Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.23-28
    • /
    • 1986
  • The sulfuric acid sulfonation mixtures of 2-aminonaphthalene, contained 2-aminonaphthalene, Dahl's acid, Broenner's acid, amino-F-acid and Baden acid, can be determined quantitatively by multicomponent spectrophotometric analysis. The analysis was performed in diluted sodium hydroxide aqueous solution and based on the ultraviolet absorption of the sodium salts of each isomers. The determination of quantity of each isomers was performed by subjection the absorbances of the unknown mixture and of its constituents, gathered at a large number of wavelengths, to a least square treatment by an electronic personer computer. This method provided a rapid analysis of such complex mixture, and the standard deviation was ${\pm}1.65$ mole %.

Development of Active thin Film Optical Waveguide $C^{2+}$ -ion Sensor (능동형 박막 광도파로 칼슘 이온 센서의 개발)

  • Lee, Su-Mi;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.49-54
    • /
    • 2000
  • A new functional organic thin film optical waveguide ion sensor is designed, which can select a specific ion, i.e., $Ca^{2+}$ -ion. The sensing membrane was composed of PVC-PVAC-PVA copolymer matrix based on anionic cation-selective chromoionophor(ETH5294), neutral ionophore(K23El), anionic site and plasticizer and it was coated on the etched glass substrate as embeded type optical waveguide itself. The sensor sensitivity dependence on waveguide length and thickness, contence of chromoionophore, and each mode was investigated. And this sensor could detect $Ca^{2+}$ ion in concentrations ranging from 1$\times$10­6~1M(with 0.05M tris-HCI buffer solution of pH7.4) by measuring the absorbance change at 514nm of light. Utilizing thin film membrane, the fast response time and high sensitivity are obtained. Also, it is expected that this sensor can be applied to various biochemical important ions.ons.

  • PDF

Effects of thickness and background on the masking ability of high-trasnlucent zirconias (고투명도 지르코니아의 두께 및 하부 배경에 따른 색조 차단 효과)

  • Kim, Young-Gon;Jung, Ji-Hye;Kong, Hyun-Jun;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.199-208
    • /
    • 2021
  • Purpose: The purpose of this study was to compare and evaluate the masking ability of three types of high translucent zirconia according to the various thicknesses and backgrounds. Materials and Methods: Using three types of high-translucency zirconia (Ceramill zolid fx white, Ceramill zolid ht+ white, Ceramill zolid ht+ preshade A2), 10 cylindrical specimens were fabricated in 10mm diameter and each with four thicknesses (0.6 mm, 1.0 mm, 1.5 mm, 2.0 mm), respectively by CAD/CAM method. The background was 10 mm in diameter and 10 mm in thickness. A1, A2, A3 flowable resin backgrounds, blue-colored core resin background, and Ni-Cr alloy background were prepared, and black, white backgrounds provided by the spectrophotometer manufacturer (x-rite, Koblach, Austria) were used. zirconia specimens and the background specimen were stacked to measure L, a*, b* with Spectrophotometer (Color i5, x-rite, Koblach, Austria) and the ΔE value with the other background is calculated. The Calculated mean ΔE values were compared based on perceptibility threshold 1.0 and acceptability threshold 3.7. Nonparametric tests such as Kruskal-Wallis test were performed to verify statistical significance (α = 0.05). Results: There was a significant difference in the mean ΔE value according to the zirconia type, background and thickness change (P = 0.000). Conclusion: According to the results of this study, the pre-colored high-translucent zirconia can obtain the desired zirconia shade when it is restored on teeth, composite resins, and abutments except for the blue resin core.

Evaluation of illumination effect for on-board spectrometer system (내장형 분광광도시스템 구성에 따른 조명 영향 평가)

  • Lee, Sangsik;Lee, Choongho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.2
    • /
    • pp.18-24
    • /
    • 2010
  • On-board spectrophotometer has been widely used as a non-contact and non-destructive measurement system in many fields. In this study, we evaluated the effect with respect to the light of on-board spectrophotometer based on a comparison with the standard spectrophotometer and color information coordinate system. Red, yellow, green and blue color paper, which were the standard reflective color paper and Munsell color paper, were used for experiments. In order to compare between a standard spectrophotometer system and an on-board spectrophotometer system, each color paper was measured 20 times. We concluded that it is possible to develop a system regardless the effect of light if the light was supplied consistently and a calibration was performed exactly while we applied an on-board spectrophotometer to non-contact and non-destructive measurement system.

  • PDF

A Simple Method for the Separation of Thorium in the Analysis of Monazite (모나자이트 분석을 위한 간편한 토륨분리법)

  • Lee Chull;Chung Koo Soon
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.5-9
    • /
    • 1971
  • A separation scheme using cation exchange procedure is designed specifically for the rapid determination of thorium in monazite samples. All the coexisting ions in monazite, including rare earth ions, are eluted with 3N hydrochloric acid. The remaining thorium is eluted from the resin column with 5N sulfuric acid prior to spectrophotometric determination with thorin reagent. The radioactive tracers and spectrophotometric methods were used to confirm the quantitative elution of thorium and also the chemical purity of the eluted thorium from the column.

  • PDF

Crystallization of a-Si : H thin films deposited by RF plasma CVD method (플라즈마 화학기상증착법으로 성장시킨 수소화 비정질 규소박막의 결정화)

  • 김용탁;장건익;홍병유;서수정;윤대호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.2
    • /
    • pp.56-59
    • /
    • 2001
  • Thin films of hydrogenated amorphous silicon (a-Si : H) of different compositions were deposited on Si(100) wafer and glass by RF plasma-enhanced chemical vapor deposition (PECVD). In the present work, we have investigated the effect of the If. power on the properties, such as optical band gap, transmittance and crystallinity, of crystalline silicon thin films. Raman data show that the material consists of an amorphous and crystalline phase for the co-presence of two peaks centered at 480 and 520cm$^{-1}$. X-ray spectra confirmed of crystallites with (111) orientation at 300w The transmittance of thin films was measured by UV-VIS spectrophotometer. In addition, Si-H chemical bondings were studied by Fourier Transform Infrared (FT-IR) spectroscopy.

  • PDF

Comparison of Standard and Lend Limit Test of Various Institutes on Lead Limit of Synthetic and Natural Food Additives (합성 및 천연 식품첨가물의 납함량에 대한 여러 기관의 규격기준 및 납시험법 비교)

  • Shin Dong-Hwa;Kim Yong-Suk;Jeong Do-Yeong;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Jang Young-Mi;Hong Ki-Hyoung;Park Sung-Kwan;Park Sung-Kug;Kwon Yong-Kwan
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.2
    • /
    • pp.82-91
    • /
    • 2006
  • Standard and lead limit test in general test method of Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), USA, and EU on synthetic and natural food additives were compared. There were found that the general test methods in 'Korea Food Additives Code' were different from standards of various institutes on lead limit test. For the lead limit test of food additives, Korea used dithizone method, Japan used atomic absorption spectrophotometry, and USA used dithizone method, flame atomic absorption spectrophotometric method, atomic absorption spectrophotometric graphite furnace method, and APDC extraction method. In addition, JECFA and EU used dithizone method and atomic absorption spectrophotometric method. The dithizone methods of Korea, USA, and JECFA were nearly identical. In the case of USA, JECFA, and EU, the analytical methods for lead limit test were shown in individual monograph. Lead limit test against 13 synthetic, such as magnesium stearate and L-cystine, and 12 natural, such as gua gum and diatomaceous earth, food additives distributed in Korea were performed by the analytical method of each institute. Although all institutes use various methods for analysis of lead, contents of lead in food additives tested fell into the standard of each institute.

The Effect of Pressure and Temperature on the Durene-Iodine Charge Transfer Complex in n-Hexane (듀렌과 요오드 사이의 전하이동착물에 대한 압력과 온도의 영향)

  • Oh Cheun Kwun;Jeong Rim Kim
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.1
    • /
    • pp.9-17
    • /
    • 1983
  • The effect of pressures and temperatures on the stabilities of the durene-iodine charge transfer complex have been investigated through ultraviolet spectrophotometric measurements in n-hexane. The stabilities of complexes were measured at 25, 40 and $60^{\circ}C$ under $1{\sim}1600$ bars. The equilibrium constant of the complex was increased with pressure and decreased with temperature raising. The absorption coefficient was increased with both pressure and temperature. Changes of volume, enthalpy, free energy and entropy for the formation of complexes were obtained from the equilibrium constants. The red-shift observed at a higher pressure, the blue-shift at a higher temperature, and the relation between pressure and oscillator strength were discussed by means of thermodynamic functions.

  • PDF