Search Result 1,871, Processing Time 0.037 seconds

A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires (전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구)

  • Hwang, Jin-Kwon
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Several electrical loads such as inrush current, normal operation arcing and non-sinusoidal loads have normal current waveforms similar to arc waveforms. To detect arcs in such loads, therefore, it is necessary to analyze difference between current waveforms with or without arcs. In this paper, using apparatuses of arc generation in UL 1699, arcs are generated in these loads and, then, arc current waveforms are investigated in both the time and the frequency domains to find arc characteristics. This investigation shows that arc current signals have shoulders at some zero current points in the time domain and increment of spectrum magnitude in all over frequency domain. It also shows that the arc characteristics at normal operation arcing and non-sinusoidal loads are detected more easily in the frequency domain than in the time domain. This investigated arc characteristics are expected to be utilized as the basis of development of arc-fault circuit interrupters.

Analysis of Transformer Losses Caused by Current Harmonics from Non-linear Load (비선형 부하 연결시 발생하는 전류 고조파에 의한 변압기 손실 해석)

  • Jang, Seungyong;Han, Sanghoon;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.171-172
    • /
    • 2015
  • 본 논문은 변압기에 부하가 연결 되었을 때 발생하는 전류 고조파에 의한 변압기 손실을 분석한다. 3상 변압기에 대해서 선형 부하와 비선형 부하가 연결되었을 경우 변압기 손실 값을 계산한다. PSIM을 이용하여 부하를 모델링하고 시뮬레이션 수행한다. 시뮬레이션을 통하여 얻어진 데이터를 이용하여 변압기의 손실값을 계산한다.

  • PDF

Fault current limiting technology to protect DC distribution systems (직류배전계통의 보호를 위한 고장전류제한기술)

  • Lee, Sungmin;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.1-2
    • /
    • 2012
  • 본 논문에서는 직류배전의 보호를 위한 고장전류제한기술을 제안한다. 제안된 전류제한기는 PWM스위칭 방식으로 동작하며 차동증폭기, 비교기, MOSFET스위치와 게이트드라이버로 구성되어 있다. 전류제한기는 부하 측의 단락사고나 돌입전류를 제어하기 위한 목적으로 직류리액터 $L_f$에 흐르는 전류를 센싱하여 기준전류 $L_{ref}$보다 높게 흐르려는 경우 MOSFET은 ON/OFF스위칭 하여 기준전류 $L_{ref}$이상으로 흐르지 못하게 함으로써 과전류가 흐르는 것을 방지한다. 제안된 전류제한기의 성능을 실험을 통하여 검증 한다.

  • PDF

무부하운전시의 철극동기기의 3상단락

  • 이면영
    • 전기의세계
    • /
    • v.10
    • /
    • pp.55-61
    • /
    • 1963
  • 본 논문에서 취급한 제동권선이 없는 철극선의 3상단락현상을 해명하는데 있어 우선 임의력율의 전류를 횡축분과 직축분으로 분리해서 취급하는 소위 Blonde의 2반작용법(two reaction method)를 썼고, 각종 Reactance를 표시하는데는 편리한 단위법(perunit notation)을 사용했으며, 전기자의 1상저항은 각종 Reactance ( $X_{x}$, $X_{q}$ )의 어느것 보담도 극소치임으로 실제계산에는 무시했으나 과도전류의 변화를 좌우하는 감쇠정수[decrement factor)에는 큰 영향을 준다는 것이 규명되었다. 해석결과로서 3상단락전류의 초기치는 특수치보다 훨씬 큰 이유로서 단락전류가 계자자속을 약하게 만들어 그 반동으로 계자회로에 일정자속을 유지하기 위하여 부문적으로 개자전류가 증대함을 알게되었고, 단락전류의 직축분과 횡축분의 구성분이 규명검토되었고, 발전기의 돌발단락저류는 일반적으로 직류분, 기본파교류분 및 제2조파등을 포함하나 그 전부가 시정수의 역수인 감쇠정수에 지배되어서 지수함수곡선에 따라 감쇠되어 결국에는 지속단락전류에 귀착한다는 사실과 3상단락은 평형단락사고임으로 영상전류는 영이며 각상과도전류의 위상차가 120.deg.라는 것엔 변함이 없다는 것과 끝으로 철극기를 정격속도로 운전해 놓고 이것을 여자해서 무부하전압을 수기시켜 그의 3상전단자를 돌연 단락해서 그의 과도전류의 파형을 Oscillograph로 촬영하면 본론에서 해석한 결과식의 그것과 일치하게 됨을 알 수 있을 것이다.것이다.

  • PDF

Development of Numerical Analysis Technology on Dynamic Characteristics of Trip Units in MCCBs (배선용차단기 트립부의 동특성 해석기술 개발)

  • Kang, Jong-Sung;Baek, Byung-San;Kwak, Chul-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1290-1291
    • /
    • 2011
  • 본 연구에서는 배선용차단기의 트립부 동작 신뢰성 향상과 트립부의 구조 최적화를 위하여 트립부 동작 특성을 정량적으로 예측할 수 있는 자계-동역학 연성해석기술을 연구하였다. 먼저 전류와 트립부 가동자 변위에 따라 가동자에 유기되는 전자기력을 예측할 수 있는 수식을 도출하였으며, 전자기력 수식과 가동자의 회전운동방정식을 시간에 따라 과도해석하여 가동자의 변위와 동작전류, 트립하중을 정량적으로 예측할 수 있는 트립부 동특성 해석기술을 개발하였다. 그리고 개발된 해석기술을 검증하기 위하여 양산 배선용차단기를 이용하여 트립실험을 실시하였으며 동작전류의 실험값과 해석값이 비교적 일치함을 확인하였다. 또한 본 연구에서는 개발된 해석기술의 활용성을 제고하기 위하여 윈도우즈 환경의 트립부 동특성 해석 프로그램을 개발하였으며, 이를 활용하여 트립부 설계변수별 동작 특성을 분석하였다.

  • PDF

Comparative Analysis of Current Controls for Boost PFC Converter under Light Load

  • Juil Kim;Yeong-Jun Choi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.143-151
    • /
    • 2024
  • In this paper, the inductor current distortion in a boost PFC (Power Factor Correction) converter under light load is mathematically analyzed, and its reasons are defined. In the average current mode control under light load, the inductor current is discontinuous, resulting in an inaccurate inductor current average value being reflected in the current control. In predictive current mode control, the current ripple is relatively large compared to the inductor current, leading to severe current distortion. In addition, the switch is turned off near the peak of the inductor current when model predictive current control is applied. Inductor current distortion must be addressed because it leads to an increase in total harmonic distortion and a decrease in power factor. In this paper, the design procedure to mitigate the light load current distortion in boost PFC converter is selected based on the mathematical analysis. Finally, a comparative analysis of control methods under light load is performed using hardware-in-the-loop simulation.

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (전력기술.정보-22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • 전명수
    • Electric Engineers Magazine
    • /
    • s.304
    • /
    • pp.22-25
    • /
    • 2007
  • 우리 나라의 전력 계통에 있어 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간 마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전위 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A, B, C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)-51.6%(관로)의 동심 중성선 순환 전류가발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실 전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • Jeon, Myung-Soo;Song, Joong-Ho;Gu, Sung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.431-433
    • /
    • 2006
  • 우리나라의 전력 계통에 있어, 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해, 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전의 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A,B,C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)$\sim$51.6%(관로)의 동심 중성선 순환 전류가 발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF

The Elimination of ion Implantation Damage at the Source/Drain Junction of Poly-Si TFTs (이온주입에 의한 소오스/드레인 접합부 결함을 제거한 다결정 실리콘 박막 트렌지스터)

  • Kang, Su-Hyuk;Jung, Sang-Hoon;Lee, Min-Cheol;Park, Kee-Chan;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1410-1412
    • /
    • 2002
  • TFT의 게이트 전극을 형성하기 전에 소오스/드레인 이온 주입과 ELA를 수행함으로써 이온 주입에 의해 발생하는 결정 결함을 줄이는 새로운 poly-Si TFT를 제안한다. 한번의 ELA 공정을 통해서 채널 실리콘 박막의 결정화와 소오스/드레인의 불순물 활성화를 동시에 이루어 접합부의 결함을 치유하였고, 이온 주입에 의해서 비정질화된 소오스/드레인 실리콘과 채널 비정질 실리콘의 용융조건 차이를 이용하여 소오스/드레인 접합부에 실리콘 그레인의 수평성장을 유도하였다. 제안된 소자는 기존의 소자(이동도 : 86 $cm^2/V{\cdot}S$, ON/OFF 전류비 $6.1{\times}10^6$)에 비해 우수한 특성(이동도 : 171 $cm^2/V{\cdot}S$, ON/OFF 전류비 $4.1{\times}10^7$)을 나타내었다. LDD나 off-set 구조 없이도 소오스/드레인 접합부의 결함이 완전히 제거되어 누설전류가 감소하였고 소오스/드레인 접합부 결함이 있던 자리에 1 ${\mu}m$ 이상의 수평성장 그레인이 위치함으로써 ON 전류도 증가하여 ON/OFF 전류비가 크게 개선되었다.

  • PDF

WS시리즈 누설전류표시부 차단기

  • KOREA ELECTRIC ASSOCIATION KOREA ELECTRIC ASSOCIATION
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.307
    • /
    • pp.68-73
    • /
    • 2002
  • 감전보호$\cdot$누전화재보호로서 누전차단기가 일반적으로 사용되고 있는데 이 누전차단기가 누전으로 트립되었을 경우 (1) 누전트립이 재현되지 않는다. (2) 누설전류치가 고조파의 영향 때문에 측정이 곤란하다는 등의 이유로 원인조사가 어려운 경우가 많다. 그래서 누전차단기의 동작원인조사를 지원하는 기기로서 WS시리즈의 노퓨즈차단기 및 누전차단기에 각종 누설전류치의 액정표시유닛을 탑재한 $''$누설전류표시부 노퓨즈차단기$\cdot$누전차단기$''$를 제품화하였다. 이에 의하여 전로에 영상변류기(ZCT)와 계측기 등을 설치하지 않고 전로의 절연열화상태나 누전사고 상황을 간단하게 파악할 수가 있다. 또 액정표시유닛의 제어전원은 차단기 내부에 포함하고 있기 때문에 특별배선작업은 불필요하다. 이 제어전원은 차단기가 오프상태 또는 트립상태에서는 끊어지나 내부에 전기이중충 콘덴서를 내장하고 있기 때문에 각종 누설전류 정보를 표시할 수가 있다(정전보상시간 100시간). 주요특징은 다음과 같다. (1)각종 누설전류의 계측과 표시(현재치, 최대치, 이동평균치, 이동평균의 최대치, 각 최대치의 발생경과시간) (2) 누전경보의 설정 감도를 세분화하여 설정가능 또한 접점경보출력 표준탑재 (3) 누전트립 발생시의 누전사고전류치 및 누전사고 발생으로부터의 경과시간 표시(누전차단기만) (4) 미쓰비시전기 누전차단기의 액티브필터와 같은 특성의 필터를 내장하고 있으며 누전차단기의 동작특성에 맞는 누설전류치 표시가능 (5) 누전경보만으로 누전트립 동작을 하지 않는 누설전류표시부 노퓨즈차단기 라인업