• Title/Summary/Keyword: 부하 곡선 생성

Search Result 69, Processing Time 0.03 seconds

Vessel Tracking Algorithm using Multiple Local Smooth Paths (지역적 다수의 경로를 이용한 혈관 추적 알고리즘)

  • Jeon, Byunghwan;Jang, Yeonggul;Han, Dongjin;Shim, Hackjoon;Park, Hyungbok;Chang, Hyuk-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.137-145
    • /
    • 2016
  • A novel tracking method is proposed to find coronary artery using high-order curve model in coronary CTA(Computed Tomography Angiography). The proposed method quickly generates numerous artificial trajectories represented by high-order curves, and each trajectory has its own cost. The only high-ranked trajectories, located in the target structure, are selected depending on their costs, and then an optimal curve as the centerline will be found. After tracking, each optimal curve segment is connected, where optimal curve segments share the same point, to a single curve and it is a piecewise smooth curve. We demonstrated the high-order curve is a proper model for classification of coronary artery. The experimental results on public data set sho that the proposed method is comparable at both accuracy and running time to the state-of-the-art methods.

Fatigue Failure Behavior of Pipe Bends with Local Wall-Thinning Under Cyclic Bending Condition (반복굽힘 조건에서 감육 곡관의 피로손상 거동)

  • Yoon, Min-Soo;Kim, Jin-Weon;Kim, Jong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1227-1234
    • /
    • 2012
  • In this study, fatigue tests were carried out using real-scale pipe bend specimens with wall-thinning defects under a cyclic bending load together with a constant internal pressure of 10 MPa. The wall-thinning defect was located at the extrados and the intrados of the pipe bend specimens. A fully reversed cyclic in-plane bending displacement was applied to the specimens. For the pipe bends with wall thinning at the extrados, an axial crack occurred at the crown of the pipe bend rather than at the extrados where the defect was located. In addition, the fatigue life was longer than that of a sound pipe bend predicted from the design fatigue curve in ASME Sec.III, and it was less dependent on the axial length of the wall-thinning defect. For the pipe bends with wall thinning at the intrados, a circumferential crack occurred at the intrados. In this case, the fatigue life was much shorter than that of a sound pipe bend predicted from the design fatigue curve, and it clearly decreased with decreasing axial length of the wall-thinning defect.

Analysis and MPPT scheme of series connected small wind turbine system (직렬운전 소형풍력발전시스템의 해석 및 MPPT 기법)

  • Kim, Chang-Ha;Ku, Hyun-Keun;Choi, Sung-Uk;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.472-473
    • /
    • 2014
  • 본 논문에서는 직렬운전 소형풍력발전시스템의 해석 방법과 최대 파워를 추종하는 MPPT(Maximum Power Point Tracking)기법을 제안한다. 소형풍력 발전시스템은 개별 발전기에서 생성되는 역기전력이 낮아 배터리 충전과 같은 독립적인 부하에 전원을 공급하는 용도로 쓰이나 발전기를 N개 직렬연결하면 계통연계가 가능하다. 일반적인 풍력발전 시스템에서의 블레이드 출력은 출력 계수($C_p$) 곡선의 형태에 의해서 결정되고, 출력계수 곡선은 주속비(${\lambda}$)의 함수로 표현된다. N개의 발전기를 직렬연결 하는 경우 각기 다른 풍속에 대하여 출력파워 해석이 곤란하므로, 직렬 운전 시 발전기토크를 기준으로 한 해석과 이에 적합한 MPPT 방법을 제안한다.

  • PDF

Indirect discharge estimation using K-River and Monte Carlo simulation at the Confluence of the Seomjin River and Yocheon (K-River와 Monte Carlo Simulation을 이용한 섬진강 요천 합류부의 간접유량 산정)

  • Kang, Han Sol;Kim, Yeon Su;Noh, Joon Woo;Byeon, Ji-Seon;An, Hyun Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.113-113
    • /
    • 2022
  • 기후 변화에 따른 집중호우의 증가로 유례없는 홍수가 발생하기도 한다. 홍수 대비를 위한 수리구조물 설계 및 홍수 예측을 위해서는 기초자료인 유량 자료가 중요하며, 이는 Rating-curve를이용하여 산정하는 것이 일반적이다. 하지만, 이를 기왕의 데이터가 부족한 지역과 적용수위 이상에 대해 적용하는 것에 한계가 있다. 2020년 8월 섬진강에 발생한 홍수는 홍수량의 추정이 어려울 뿐 아니라 기존의 Rating curve를 활용하여 홍수량을 추정하는데 한계가 있다. 섬진강 하천정비기본계획(2021)에 따르면 섬진강 남원(신덕리) 관측소는 100년 빈도 홍수량이 7,470m3/s인 반면, 선형 보간을 통한 Rating curve 외삽 결과 약 23,000m3/s로 많은 차이 나는 것을 확인할 수 있다. 따라서, 본 연구에서는 외삽의 불확실성과 직접 측량에 어려움이 있는 홍수기 유량 추정을 위해 수리학적 해석 방법을 이용한 간접유량 산정기법을 제시하였다. 수치해석모형을 이용하여 홍수사상을 재현하고, 이를 역으로 이용하여 관측 수위와 근접한 계산 결과를 보인 입력 자료로부터 대상 지역의 유량을 간접적으로 산정하였다. 상류단 유량자료의 생성을 위하여 Rating curve의 변수에 대하여 무작위 조합을 생성하였고, K-River(1차원 수리해석 모형)를 이용하여 MCS(Monte Carlo Simulation)를 수행하였다. 계산된 수위와 관측 수위간 수위 재현성 평가(NSE, RSR)를 통해 최적 결과를 나타낸 Rating Curve의 변수들로부터 경계조건의 Rating Curve를 산정하였다. 방법론의 검증을 위해 요천 합류부에 적용하였으며, 그 결과 기존 곡선식의 외삽에 따른 유량 자료의 수위 재현성과 비교하여 개선된 것을 확인하였다. 이를 활용하여 수자원 유량 자료의 신뢰도 개선에 활용이 가능할 것으로 판단된다.

  • PDF

Comparison of MPPT Efficiency between Duty - Cycle Control and Current Control (Duty 제어와 전류 제어 방식의 MPPT 효율 비교)

  • Lee, Jaehyun;Jo, Jongmin;Lee, Jaedo;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.132-134
    • /
    • 2018
  • 본 논문은 태양광발전 시스템에서 P&O 방식 기반의 제어 기법인 duty 제어와 전류 제어 방식의 최대전력점 추종특성을 동일모드 조건에서 비교하였으며, 시뮬레이션 및 실험을 통해 검증하였다. Duty 제어 방식은 P-V 특성곡선을 이용하여 전력과 전압의 변화량을 통해 duty 증감을 결정함으로써 동작점을 결정한다. 이와 달리, 전류 제어 방식은 P-I 특성곡선을 이용하여 전력과 전류의 변화량을 통해 전류 지령치를 생성하고 비례-적분제어기를 통해 전류제어를 수행하여 동작점을 결정한다. 두 가지 제어 방식의 정확한 비교를 위해 등가의 ${\Delta}duty$${\Delta}I_{ref}$의 값을 선정하여 모드 변화에 따른 ${\Delta}V$의 변화를 동일하게 맞추었다. DC - DC 부스트 컨버터를 이용하여 시뮬레이션과 실험에 두 제어 방식의 태양광발전 시스템을 구성하여 태양광 전압과 전류, 에너지 측면에서 특성을 비교하였다. 최대 전력점이 1.7kW인 특성곡선 조건 하에서, 시뮬레이션과 실험의 결과로 두 방식은 동일 MPPT 모드 시 동일한 동작점에 존재하며, 같은 값의 전력을 출력하여 동일한 성능의 효율을 보임을 검증하였다.

  • PDF

Analysis of Shallow Water Flow in Curved Channel Using Dispersion Stresses Method (분산응력법을 이용한 곡선수로에서의 천수흐름 해석)

  • Song, Chang Geun;Seo, Il Won;Kim, Tae Won;Ahn, Jungkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1785-1795
    • /
    • 2013
  • Most of the previous models for analysis of shallow water flow assumed the uniform velocity distributions over the flow depth so that they produced incorrect velocity prediction at meandering part due to the ignorance of secondary current. In this study, the vertical velocity profiles in longitudinal and transverse direction were decomposed as the mean and variation components, which resulted in additional dispersion stresses terms in momentum equations. The proposed model were applied at the channels with $30^{\circ}$, $90^{\circ}$, $270^{\circ}$ bends, and shallow water flow in curved channel was analyzed using dispersion stresses. The dispersion stresses acted as a sink or source in the momentum equations, which caused the transverse convection of momentum to shift from the inner bank to the outer bank.

$H_2$ gas flow rate가 비정질 실리콘 박막 태양전지의 i-layer에 미치는 영향에 대한 simulation

  • Park, Seung-Man;Gong, Dae-Yeong;Lee, Won-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.303-303
    • /
    • 2010
  • 비정질 실리콘 박막 태양전지의 수광부인 i-layer는 비정질의 특성 상 많은 defect을 함유하고 있다. 이러한 defect들은 빛에 의하여 생성된 전자정공 재결합에 있어서 주도적으로 작용하게 된다. $H_2$는 이러한 defect들의 생성을 줄여주어 박막의 특성을 향상시켜주는 것으로 알려져 있다. 본 논문에서는 비정질 박막 태양전지의 수광부로 사용되어지는 i-layer의 $H_2$ gas flow rate의 변화에 따른 태양전지의 특성을 simulation해 보았다. $H_2$는 1:0에 1:5까지 변화시켰고 그에 따른 태양전지의 QE, LIV, DIV 곡선을 통하여 특성을 알아보았다. 또한 추가적으로 i-layer의 두께에 따른 효율의 변화도 simulation해 보았다.

  • PDF

Research on the Design Methods of Appendages to Reduce Vortex Flows Around Underwater Vehicles (수중운동체 주위 와류유동 저감을 위한 부가물 형상 설계기법 연구)

  • Sang-Jae Yeo;Suk-Yoon Hong;Jee-Hun Song
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.252-261
    • /
    • 2024
  • This research establishes design standards for vortex reduction devices (VRDs) aimed at minimizing underwater radiated noise by mitigating horseshoe vortex (HSV) and root vortex (RV) generated at the junction of appendages and the hull of underwater vehicles. Initial analysis replaced the influence of appendage dimensions and flow velocity with the Reynolds number by verifying the Reynolds similarity of vortex flows. The three-dimensional surfaces of VRDs were parameterized using Bezier curves. Optimal length-to-height ratios were identified by evaluating the vortex reduction performances of VRDs with various dimensions. Ultimately, non-dimensional design standards were derived for VRDs, ensuring effective vortex reduction across any appendage, thereby enhancing stealth performance.

Probabilistic External Flood Hazard Assessment at Major National Facilities (국가주요시설물에 대한 확률론적 외부 침수 재해도 평가)

  • Kim, Beom Jin;Kim, Byunghyun;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.387-387
    • /
    • 2020
  • 본 연구에서는 LIP에 의한 극한강우로부터 발생되는 극한홍수량을 산정한다. Huff 형 강우시간 분포를 기후변화 시나리오별로 적용하고, 원전주변지역에서의 상세한 토지이용조건의 변화를 고려하여 빈도별 홍수량을 산정한다. 외부침수해석의 정교화를 위한 상세 지형자료를 구축하고, 원자력발전소 부지의 상세 DEM 자료를 생성한다. 이를 위해서 원자력발전소 부지에서 건물, 연석, 도로 등의 영향을 분석하고 토지이용상황에 따른 조도계수를 산정한다. 또한 원전지역에서의 외부침수재해도 분석을 위해서 국립해양조사원에서 검토한 기후변화를 고려한 조위분석 자료를 외부경계조건으로 설정한 후 부지에 대한 2차원 수리분석을 실시한다. 침수심, 침수유속, 침수시간, 침수동압력 분석 등 2차원 침수해석결과를 바탕으로 발생빈도별 침수심, 침수강도 등의 정량적인 분석을 통해서 빈도별 재해도 곡선을 개발한다. 그리고 원전지역에서의 외부 침수에 대한 대표적인 재해도 곡선을 산정하기 위하여 재현기간별 지속시간에 따른 침수심을 분석하고 정리한다. 재현기간별 침수심에 대해 확률 분포형을 적용하기 위해서 AIC검증을 통한 분포형의 적합성을 분석을 실시한다. 또한 재현기간별 지속시간에 따른 침수심들 간의 상관관계를 분석하여 분포형에 적용한다. 적용된 분포형을 몬테칼로 시뮬레이션을 통한 대표적인 확률론적 외부 침수 재해도 곡선을 산정한다. 본 연구를 바탕으로 원전 부지 및 그 부속 시설물(SSC)의 홍수방지 기능과 홍수 대비 시설물에 대한 적용 절차의 신뢰성, 홍수 저감 및 대응 전략에 대한 정량화가 가능하여 원전 홍수 위험에 대한 정량적인 평가 지원이 가능하겠다. 고려할 외부 홍수와 관련된 원전 내부시설 및 장비에 대한 상세한 모델링 절차, 특정 시나리오에 대한 홍수 방지 및 예방과 관련한 SSC의 정량화, 홍수저감 활동과 관련된 통제실 외부 시설물에 대한 수동 조작에 대한 평가가 이루어질 수 있겠다.

  • PDF

Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis (N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화)

  • Choi, Yong;Kim, Joon-Young;Im, Ki-Chun;Kim, Jong-Ho;Woo, Sang-Keun;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.316-326
    • /
    • 1999
  • Purpose: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. Materials and Methods: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. Results: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope = 0.84, r = 0.91), Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 ($0{\sim}1min$), 0.98 ($0{\sim}2min$), 0.86 ($1{\sim}2min$)). Conclusion: The results of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction.

  • PDF