• Title/Summary/Keyword: 부하전류 측정

Search Result 193, Processing Time 0.024 seconds

Measurements of Load Current of XLPE Cables Installed at the Load Terminal of Turbine Generator in Operation at Thermoelectric Power Station (화력 발전소의 터빈 발전기 부하단에 설치된 XLPE 케이블의 부하전류 측정)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.207-212
    • /
    • 2017
  • The cables installed to deliver high electric power from a generator at a thermoelectric power station are XLPE (or CV) cables. Depending on the installation and usage conditions, the cables in operation start deteriorating from the time of initial operation. Some cables can cause accidents due to faulty construction or other environmental factors. In order to prevent cable accidents, regular auditing of power cables is required. We have invented a measuring device for systematic surveillance and prevention of accidents, and installed the device at Korean Western Power Co. Ltd. which measures load currents through the cables. In this paper, we present the load current measured using our device, analyze the load characteristics by measures current, compare the ampacity defined by IEC standard, and present a basic data to obtain the temperature of cable conductors.

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.

Fault analysis and protection of the DC traction power supply system (전기철도 DC급전시스템의 보호 및 사고전류해석)

  • Chung, S.G.;Lee, B.S.;Jeong, R.K.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.30-33
    • /
    • 2001
  • 도시철도 DC 급전시스템은 부하전류가 사고전류보다 클 수 이는 특징을 가지고 이다. 이러한 이유로 DC 급전시스템에서는 di/dt를 측정하여 사고전류를 부하전류로부터 구분하고 있다. 이것은 사고전류의 di/dt와 부하전류의 di/dt는 서로 다른 상이한 특성을 보이고 있기 때문이다. 본문에서는 DC도시철도급전시스템에서 흔히 사용되는 di/dt 계전기와 이의 설정을 위한 사고전류의 분석 및 설정방법에 대해 알아본다.

  • PDF

A Study on the Detection of Indication of Accident in Electric Equipments with Incandescent Lamps Using Current Monitor (전류 모니터를 이용한 백열등 부하 전기설비에서 사고 징후 검출에 관한 연구)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.109-115
    • /
    • 2009
  • This paper describes an early detection for indication of electric accident using current waveform which is measured in electric equipments consisted incandescent lamps. At first, it analyzes characteristics of current monitor in resistive electric circuit. In second, the electric equipment is consisted of incandescent lamps. And the electric accident is simulation of tracking according to KS C IEC(Korea Standard C International Electrostatic Commission) 60112 at some part of the electric equipment. The indication of the electrical accident is detected to analyzing current waveform measured by current monitor. As the tracking breakdown, electric accident, processes, as current pulse is bigger and ratio of appearance also is increased irrespective of amount of load.

A Study on Control Method of Parallel Single-Phase APF Using Rotating Reference Frames (회전좌표계를 이용한 병렬형 단상능동전력필터의 제어알고리즘에 관한 연구)

  • Heo J.S.;Kim Y.J.;Kim Y.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.208-211
    • /
    • 2003
  • 본 논문에서는 비선형 단상부하에 의해 발생하는 전류 고조파를 보상하기 위한 단상능동전력필터의 제어방법을 제안한다. 측정된 부하전류에 시간지연을 주어 가상의 두 번째 상을 만들어서 단상시스템을 두 축을 갖는 시스템으로 만들어 복소계산이 가능하게 한다 기존의 방법과 달리 저역통과필터의 지연특성을 고려하여 필터를 통과한 지연된 위상을 가진 정현파를 가상의 상으로 이용하였다 두 개 의상이 존재하므로 순시로 무효전력을 구할 수 있게된다. 본 논문에서는 회전좌표계를 사용하여 순시계산을 하였고, 부하전류만을 검출하여 보상전류 지령치를 구하였다. RL부하에 대한 실험을 수행하였고, 이러한 실험을 통하여 제안된 제어법의 유효성을 입증하였다.

  • PDF

Harmonic Current Test of Electric High Speed Train (전기철도차량 고조파 전류 시험)

  • Lee, Tae-Hyung;Kim, Joo-Rak;Jang, Dong-Uk;Lee, Jang-Mu;Park, Chan-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.304-306
    • /
    • 2006
  • 전기철도차량에서 사용한 부하전류는 귀환 회로인 궤도를 통해 변전소로 유입한다. 전기철도차량에서 사용하는 전력변환장치 때문에 부하전류에는 고조파가 함유되고 이 고조파 전류는 외부통신선에 영향을 주지 않아야 한다. 본 논문에서는 한국형 고속열차를 대상으로 고조파 전류를 측정하여 외부통신선 영향을 평가하는 등가방해전류로 환산하고 그 기준으로 평가한 결과를 소개한다.

  • PDF

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

The Life Analysis for the Influence of Output Ripple Current by Frequency applied in a PEMFC (출력 리플전류 주파수에 따른 연료전지 수명 연구)

  • Kim, J.H.;Jang, M.H.;Choi, J.S.;Kim, D.Y.;Tak, Y.S.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.383-384
    • /
    • 2010
  • 본 논문에서는 연료전지에 연결되는 부하가 어떠한 주파수특성을 갖는 것이 바람직한지 알아보기 위해 출력 리플전류 주파수에 따른 연료전지 수명의 영향을 알아보았다. 전자부하를 통해 일정한 크기의 리플전류를 주파수대역을 바꿔가며 단위 셀에 인가하여 장시간 운전한 뒤 연료전지의 전압-전류곡선을 측정하였다. 측정된 전압-전류곡선을 통해 연료전지의 성능을 비교함으로써 어떠한 출력 리플전류 주파수가 연료전지 수명에 더 큰 영향을 주는지 확인하였다.

  • PDF

A Study on Speed Error of Disk Type SPMSM with Eccentric Load (편심 부하를 가지는 Disk Type SPMSM에서 속도오차에 관한 연구)

  • Lee, K.W.;Kim, Y.S.;Lee, H.J.;Ryoo, S.R.;Kwon, Y.A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.109-111
    • /
    • 2002
  • 디스크 형의 회전자를 가지고 있는 영구자석 표면 부착형 동기 전동기에서 회전자가 중력 방향에 직각으로 서있고, 디스크 상에 부하가 존재하는 경우 디스크의 불균일한 질량 분포에 의해 편심이 발생한다. 편심 부하는 합성 무게 중심이 반중력 방향으로 향하면 전동기의 속도는 감소하고, 중력 방향이면 속도가 증가하는 정현적인 부하 토크로 작용하여 정현적 인 속도 오차를 발생시킨다. 이 속도 오차를 감소시키기 위해 q-축 전류와 측정된 속도를 입력으로 가지는 부하 토크 관측기를 설계하여 생성된 보상전류를 피드 포워드 방식으로 q-축 지령 전류에 보상하는 방식을 사용한다. 본 연구에서는 부하 토크 관측기를 사용하는 방식에서 발생하는 속도오차에 관하여 분석하였다.

  • PDF

고속파 전자가열을 시도한 KSTAR 토카막 원형 플라즈마에서의 ICRF 고주파 부하 저항

  • Wang, Seon-Jeong;Kim, Seon-Ho;Gwak, Jong-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.297-297
    • /
    • 2010
  • KSTAR 토카막의 두번째 실험 캠페인 동안 고속파 전자가열 (FWEH)을 위한 ICRF 고주파입사 실험을 실시하였다. 토로이달 자기장은 2 T, 플라즈마 전류는 200-300 kA, 주반경은 1.8 m, 부반경은 0.5 m의 원형 플라즈마가 가열 대상이 되었으며, 네개의 ICRF 안테나 전류띠 가운데 중심부의 두개의 전류띠를 최대 300 kW로 구동하기 위한 운전 주파수는 44.2 MHz가 선택 되었다. 이 주파수는 플라즈마의 모든 영역에서 이온 사이클로트론 공명을 일으키지 않으므로 플라즈마에 흡수되는 대부분의 출력은 전자에게 전달될 것으로 기대되었다. 낮은 고주파-플라즈마 결합으로 인하여 전송선의 최대 고주파 전압이 허용치를 초과하기 때문에 비교적 낮은 최대 출력만이 허용 되었으나, ECE에 의해 관측된 전자의 온도는 국지적으로 최대 150 % 까지 증가하는 것을 확인 할 수 있었다. 낮은 고주파-플라즈마 결합의 첫번째 원인은 FWEH의 효율이 이온을 가열할 때 보다 상대적으로 낮기 때문이다. 플라즈마 내에 이온 사이클로트론 공명층이 형성되면 높은 효율로 고주파를 입사 할 수 있다는 것은 잘 알려진 사실이다. 또다른 원인은 D 형상의 플라즈마에 맞도록 만들어진 안테나와, 원형 플라즈마간의 부조화로 인하여 고속파 차단층이 (Fast Wave Cutt-off Layer) 평균적으로 넓게 형성되기 때문이다. 플라즈마 외곽에 반드시 존재하는 낮은 플라즈마 밀도의 고속파 차단층 내부에서, 중심부로 향하는 고주파의 진폭은 지수함수로 감쇠하므로 가능하면 플라즈마 밀도를 높여 차단층 자체의 폭을 줄이거나, 안테나 전류띠를 플라즈마에 바짝 접근시켜야만 한다. 고주파 진단 장치로는 송출기의 출력과 반사파 측정 장치, 공명루프의 전압 측정 장치가 있는데, 이것들을 이용하여 안테나에 전달되는 출력 및 고주파-플라즈마 결합 효율을 나타내는 플라즈마에 대한 고주파 부하 저항을 구할 수 있다. 측정 결과, 부하 저항의 최소값은 진공시 또는 ICRF만의 방전시의 값 0.25 Ohm 보다 큰 0.5 Ohm을 나타냈으며, 최대값은 플라즈마의 상태에 따라 1 Ohm에서 2 Ohm 사이에서 매우 빠르게 요동하는 것을 확인했다. Mm 파 반사계의 측정에 의하면 플라즈마 언저리의 위치가 약 3 cm 정도의 크기로 요동하는 것으로 나타났는데, 부하 저항과 언저리 위치의 파형이 정확하게 일치하지 않지만 유사한 경향성을 가진 것으로 보인다. 따라서 플라즈마 언저리 위치의 제어를 통하여 가열 효율을 높게 유지할 수 있음을 알 수 있다. 본 발표에서는 실험의 소개와 함께 부하 저항의 관점에서 가열 효율을 높일 방안을 토론하도록 한다.

  • PDF