• Title/Summary/Keyword: 부유세균

Search Result 88, Processing Time 0.039 seconds

Bacterial Community of Free-living and Aggregated Bacteria at Thawing Period in Lake Baikal (해빙기 바이칼호에서 부유세균과 Aggregates에 부착한 세균의 군집구조)

  • 홍선희;김옥선;전선옥;유재준;안태석
    • Korean Journal of Microbiology
    • /
    • v.38 no.3
    • /
    • pp.192-197
    • /
    • 2002
  • Fluorescent in situ hybridization (FISH) with rRNA-targeted oligonucleotide probes was used to compare the community structures of free-living and aggregated bacteria at thawing period in Lake Baikal. Targeted groups were Eubacteria, $\alpha$-, $\beta$-, $\gamma$- proteobacteria groups, Cytophaga-Flavobacterium group and Planctomycetales. Total bacterial numbers of free-living bacteria were ranged from $0.2{\times}10^6\cells{\cdot}ml^-1$ to $3.2{\times}10^6\cells{\cdot}ml^-1$, which were decreasing with depth, while the aggregated bacterial numbers were dramatically increasing from $0.4{\times}10^4 to 3.3{\times}10^4 \cells{\cdot}ml^-1$ with depth. The ratios of EUB probe binding cells to DAPI counts were ranged from 52.3 to 74.1% in free-living bacteria, and from 39.6 to 66.7% in the aggregated bacteria, respectively. Community structures of the aggregated bacteria were very different from each free-living bacteria at every depth. At 25 m depth, where the chlorophyll a concentration was highest, both structures were quite different from those of surface layers, rendering the fact that the community structures might be affected by phytoplankton. The vertical profile of community structure of aggregated bacteria is particular. The proportion of $\beta$-proteobacteria group was increasing with depth and it was 51.8% at 100 m, but the dominant group was $\gamma$-pro-teobacteria group at 250 m. Taken together, the biodiversity and succession of aggregated bacteria are quite different from free-living bacteria.

Concentrations of total culturable microorganisms and Its Identification in Public Facilities (다중이용시설의 실내공기 중 총부유세균 농도와 종류)

  • Jeon, Byoung-Hak;Hwang, In Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.868-876
    • /
    • 2015
  • This study was conducted to measure the concentrations of total culturable bacteria (TCB) and to identify the bacteria in thirty public facilities (7 elderly-care facilities, 4 hypermarkets, 4 university hospitals, 7 child care facilities, 4 subway stations and 4 bus terminals) in Seoul and Gyeonggi-Do Province. Although all concentrations measured in these study facilities did not exceed the national maintenance standard, it is believed that elderly-, child-care facilities should be high priority facilities to improve the indoor air quality and it is important to study the health effects and the airborne bacteria concentration of public facilities including non-culturable bacteria or allergen.

Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology (유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험)

  • Su Yeon Lee;Chang Soo Kim;Gyu Ri Kim;Jong Eon Im
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.344-351
    • /
    • 2023
  • Purpose: This study aimed to evaluate the effectiveness of a dielectric barrier discharge (DBD) plasma module for sterilizing airborne bacteria in indoor spaces and measure the concentration of ozone generated during plasma discharge. Method: The DBD plasma module was installed in a 76m3 space, and air samples were collected under various discharge times to compare the reduction of airborne bacteria. Result: The results showed a significant decrease in airborne bacteria, ranging from 92.057% to 99.999%, with an average ozone concentration of 0.04 ppm, below the reference value. Conclusion: The study suggests that plasma discharge can be used as a means of preventing the spread of airborne bacteria and viruses, while ensuring safety for human exposure.

Effect of Mechanical Agitation on Generation of Airborne Bacteria and Endotoxin in Exhaust Gases from Lab-Scale Composting of Sewage Sludge (실험실 규모 하수슬러지 퇴비화공정에서 기계적 교반이 배출가스 내 부유세균과 내독소의 발생특성에 미치는 영향)

  • Kim, Ik-Hyeon;Kim, Ki-Youn;Phae, Chae-Gun;Kim, Dae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.143-148
    • /
    • 2012
  • This study was performed to investigate the concentration variation of airborne bacteria and endotoxin by the temperature in the compost pile in order to identify the generation characteristics of biological factors in the exhaust gases generated from lab-scale sludge compositing reactors (0.06 $m^3$ of total reactor volume). Airborne bacteria showed the highest concentration of generation ($1.03{\times}10^5\;CFU/m^3$) in the composting reactor without mechanical agitation, and similar change tendency to temperature variation of composting, but somewhat lower statistical significance (p>0.05). In the compost reactor with mechanical agitation, endotoxin showed similar generation characteristic to temperature variation of composting (statistical significance; p<0.05) and the highest generation concentration to 1,415 EU/$m^3$. Mechanical agitation of the composting process affected activity of microorganism and positive generation of endotoxin in exhaust gases. Endotoxin and airborne bacteria showed similar tendency of generation, especially the highest statistical correlation was observed in the compost reactor without mechanical agitation (statistical significance: p<0.01).

The Change of Attached Bacterial Community on Aggregates in Lake Paldang (팔당호에서 Aggregates에 부착한 세균군집구조의 변화)

  • 홍선희;오덕화;전선옥;안태석
    • Korean Journal of Microbiology
    • /
    • v.36 no.4
    • /
    • pp.292-298
    • /
    • 2000
  • For scrutinizing the changes of aggregated bacteria in Lake Paldang, the FISH method was applied by using the rhodamine labeled probes, and total bacteria, chloropyll a concentrations and nutrients concentrations were measured. The aggregates were collected with sediment traps. The T-N, T-P, chlorophyll a concentrations of aggregates were higher 5-15 times, 81-140 and 49-66 times than water samples, respectively. Also, the bacterial numbers of aggregates were 200 times higher than those of water smaples. The ratios of each groups of water sample were 2.1-7.4% for $\alpha$-group, 4.5-8.3% for $\beta$-group, 2.1-7.4% for $\gamma$-group, 2.1-6.1% for Cytophaga-Flavobacterium group and 0.1-2.5% for 'other'group, respectively. While, in aggregates, the ratios of $\alpha$-, $\beta$-, $\gamma$- and Cytophaga-Flavobacterium groups were very small and most abundant group was 'other' bacteria. With these results, the aggregated bacteria in Lake Paldang had a particular group composition of bacteria.

  • PDF

The Study of Relationship on Bio-Aerosol with Indoor Temperature Difference (실내 온도차에 따른 부유세균과의 상관관계 연구)

  • Park, Jin-Young;Kim, Sam-Uel;Yun, Jung-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.737-741
    • /
    • 2008
  • The indoor environment has an effect on heath of human in indoor room that they live largely. We will know Bio-Aerosol that causes illness, such as a flu, an asthma and an atopy etc. and see a relationship between Bio-Aerosol and temperature as an experiment in Air-Conditioned room. In the future, this data can use a basic data for an effect of Bio-Aerosol on indoor environment.

  • PDF

A Research to Decrease Airborne Microoganism the Train (전동차내 부유 미생물 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2895-2901
    • /
    • 2011
  • SeoulMetro(line number 1 to 4) for the first half of the year. Therefore air quality in the subway is very important. It is passengers, such as sneezing and respiratory vital activities, Suspended due to skin keratin microbial action, and Microbial contaminants such as viruses. Hypersensitivity disorders, an atopic dermatitis, infectious diseases, allergic diseases, and can cause respiratory diseases. Ministry of Environment and National Institute of Environmental Research is managed so the life bacteria. It is emerging as the occupational health problems. Introduction of an appropriate ventilation system for cooling and dehumidification is needed. In line number 2, commuting and normal trains are measured in-room floating microbes. Suspended bacteria and fungi suspended in 2011 for 85 ~ 385$cfu/m^3$, 67 ~ 98$cfu/m^3$ is lower than baseline. Suspended to prevent microbial contamination and air conditioning equipment performance is a substantial improvement. Suspended micro-organisms and the impact on passenger room ventilation is increased. Electric car how to improve air quality substantially investigated.

  • PDF

Investigation of bacteria in indoor air of a greenhouse for button mushroom cultivation (양송이 재배사 공기 중에 존재하는 세균조사)

  • Kwon, Hyuk Woo;Choi, Min Ah;Oh, Youn-Lee;Kong, Won-Sik;Kim, Seong Hwan
    • Journal of Mushroom
    • /
    • v.13 no.1
    • /
    • pp.26-29
    • /
    • 2015
  • Since button mushroom (Agaricus bisporus) cultivation is performed in closed environment, the understanding of indoor environment becomes essential for the quality and quantitative production of the greenhouse-grown mushroom. To generate information on indoor environmental factors affecting on fruiting body quality, we investigated temperature, humidity, and bacterial concentration and species in a greenhouse located in Buyeo, Chungnam Province. Temperature and humidity were recorded as $19.75{\pm}0.35^{\circ}C$ and $87{\pm}3.67%$, respectively. The total concentration of bacteria was measured as $3.84{\times}10^3CFU/M^3$. Advenella kashmirensis, Bacillus vietnamensism, B. licheniformis, Burkholderia sordidicola, Fictibacillus phosphorivorans, Lysobacter daejeonensis, Microbacterium esteraromaticum, Pseudomonas aeruginosa, P. protegens, P. gessardii, P. mosseli were identified from indoor air of the greenhouse.

Development of air-sterilization purification system of fusion and composite structure using broadband-to-active photocatalyst (광대역대 활성광촉매를 활용한 융·복합 구조 공기살균정화장치 개발)

  • Yoon, Sueng-Bae;Hwang, Yun-Jung;Kim, Seung-Cheon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.147-151
    • /
    • 2019
  • Modern people spend most of their daily lives in their homes, schools, or workplaces, hospitals, shopping malls, subway stations, rooms, and parking lots. According to the survey, air quality management at the multi-use facility is less than 50% satisfied. In this study, a photocatalytic filtration system is developed by utilizing a broadband-to-active photocatalyst that utilizes a media photocatalyst filter that removes airborne germs from indoor air as well as indoor air quality and operates on visible light as well as ultraviolet light.