• Title/Summary/Keyword: 부식전류

Search Result 266, Processing Time 0.024 seconds

Evaluation of Rail Leakage Current and Potential in DC Railway (직류철도의 레일누설전류 밑 전위평가)

  • Han, Moon-Seob;Jung, Ho-Sung;Kim, Ju-Rak;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.161-166
    • /
    • 2009
  • DC feeding system is mainly floating but rail potential and leakage current are due to long parallelism between rails and ground, namely rail resistance and rail to ground conductance. Rail potential causes electric shock to human and rail leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important in recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized. Monitoring and controlling rail leakage current is proposed in order to maintain rail resistance and rail to ground conductance.

Effect of steel fibers on surface electric resistivity of steel fiber reinforced concrete for shield segment (강섬유보강 콘크리트 세그먼트의 강섬유가 표면전기저항에 미치는 영향)

  • Moon, Do-Young;Lee, Gyu-Phil;Chang, Soo-Ho;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.557-569
    • /
    • 2011
  • Steel Fiber Reinforced Concrete (SFRC) is widely used for tunnel structures such as shotcrete and segments. Corrosion of steel fibers and steel reinforcements may affect on the long-term durability of the concrete structures with steel fibers and reinforcement. Therefore, a study on the feasible method to evaluate corrosion possibility and permeability of the concrete structures is required. This experimental study examines the effect of steel fibers and internal reinforcement on the surface resistivity. Steel fiber mix ratio and corrosion of internal reinforcement were considered as variables. In the results, steel fibers significantly reduce the surface resistivity due to those conductive characteristic. In the case of 3% mix ratio, it was difficult to evaluate rate and permeability of corrosion due to the great reduction of resistivity by mixing of steel fibers.

Corrosion Resistance of Cr-bearing Rebar to Macrocell Corrosion Caused by Concrete with Crack (피복 콘크리트의 균열 발생에 기인한 매크로셀 부식 환경하에서의 Cr강방식철근의 방식성)

  • Tae, Sung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.79-86
    • /
    • 2006
  • This study was investigated to corrosion resistance of Cr-bearing rebars to macrocell corrosion caused by concrete with crack. Ten types of steel bars having different Cr contents were embedded in concretes with imitation crack. The corrosion resistance of the Cr-bearing rebar was examined by measuring half-cell potential, macrocell corrosion current, corrosion area and weight loss up to 105 cycles of salt spray testing. The results revealed that the Cr content required for corrosion resistance in a macrocell corrosion environment caused by chloride ion gap of $3kg/m^3$ was 9% or more. The corrosion-resisting performance of Cr-bearing rebar was particularly noticeable with a Cr content of 11% or more.

Atmospheric Effects on Corrosion of Iron in Borate Buffer Solution (Borate 완충용액에서 철의 부식에 대한 대기의 영향)

  • Kim, Hyun-Chul;Kim, Younkyoo
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.6
    • /
    • pp.673-678
    • /
    • 2012
  • Using potentiodynamic and linear polarization method, the atmospheric effect on the corrosion of iron in borate buffer solution was investigated. The corrosion of iron was heavily influenced by the degree of oxygen concentration. The supply of reduction current was increased by the reduction of dissolved oxygen, and the corrosion potential of iron was shifted to the positive side. The $OH^-$ ion, which was produced through the reduction of either water or oxygen, significantly increased the $OH^-$ ion concentration inside of the electrical double layers of iron electrode, and facilitated the adsorption of $OH^-$ ion on the surface of the iron electrode. The adsorption of $OH^-$ ion on the iron electrode can be explained either by Langmuir isotherm or by Temkin logarithmic isotherm.

Effect of Si on the Corrosion Properties of Mg-Li-Al Light Alloy (경량화 Mg-Li-Al합금의 내식성에 미치는 Si의 영향)

  • 김순호
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.52-57
    • /
    • 1998
  • Effect of Si in the electrochemical corrosion characteristics of Mg-Li-Al light alloy has been investigated by means of potentiodynamic polarization study. The elecrochemical behaviors were evaluated in 003% NaCl solution and the solution buffered with KH$_{2}PO_{5}{\cdot}$NaOH at room temperature. It was found that the addition of very small quantity of Si (0.48 wt%) in Mg-Li-Al light alloy increased corrosion rates and amount of corrosion products and decreated the pitting resistance of the alloy. From the results it was concluded that Si which is added to increase the strength of Mg-Li-Al alloy is harmful to corrosion properties of the alloy.

  • PDF

Anodic Dissolution of Electrodeposited Iron Group Elements in Phthalate Buffer Solution (Phthalate 완충용액에서 전해 석출한 철족 원소의 산화 용해 반응)

  • Chon, Jung-Kyoon;Kim, Youn-Kyoo
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.14-20
    • /
    • 2007
  • The anodic dissolution of electrodeposited iron group elements (Fe, Co, Ni) were studied in phthalate buffer solution. The pH dependence of the corrosion potential, the corrosion current and Tafel slope was measured for each element. Based on the electrochemical parameters including Tafel slopes, we proposed the redox mechanism of the corrosion and the passivation. The adsorption of various phthalate species on the electrodeposited iron group elements seemed to be affected the corrosion mechanisms.

An Electrochemical Evaluation on the Crevice Corrosion of 430 Stainless Steel with Variation of Crevice Wide by Micro Capillary Tubing Method (Micro Capillary Tube 방법을 이용한 430 스테인레스강 틈의 폭변화에 따른 틈부식의 전기화학적 평가)

  • Na, Eun-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.250-254
    • /
    • 2003
  • In this study, the IR drop theory was adopted to explain the initiation of crevice corrosion in the framework of IR drop in crevice electrolyte. Furthermore, the electrochemical polarization was measured to study the mechanism of crevice corrosion for type STS430 stainless steel. lest method adopts under condition that the size of specimen is $10\times20\times5mm,\;in\;1N\;H_2SO_4+0.1N\;NaCl$ solution, and the artificial crevice gap sizes are three kinds, the Micro capillary tube size is inner diameter 0.04 mm, outer diameter 0.08 mm. Crevice corrosion is measured under the applied voltage of passivation potential -200mV/SCE, resulted from anodic potentio-dynamic polarization to the external surface along the crevice. The potential difference was measured by depth profile by Micro capillary tube which inserted in the crevice. The obtained results of this study showed that 1) As artificial crevice gap size became narrow, the current density was increased, whereas no crevice corrosion was found in the crevice gap size $3\times0.5\times16mm\;in\;1N\;H_2SO_4+0.1N\;NaCl\;solution\;at\;20^{\circ}C$ 2) potential of the crevice was about from -220 to -358mV which is lower than that of external surface potential of -200mV The results so far confirmes that the potential drop(so-called IR drop) in the crevice is one of the major mechanisms the process of crevice corrosion for 430 stainless steel.

The Inhibitive Effect of Electrochemical Treatment Applied to Fresh/hardened Concrete (철근 부식 방식을 위한 굳지 않은/굳은 콘크리트의 전기방식 적용에 관한 연구)

  • Kim, Sung-Wook;Moon, Jae-Heum;Ann, Ki-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.67-76
    • /
    • 2013
  • In this study, the inhibitive effect of electrochemical treatment subjected to fresh and hardened concrete and literature reviews in terms of the treatment were performed. In hardened concrete, chloride ions are mixed during casting to destroy the passivity of steel, and then the current was provided for 2 weeks with 250, 500 and $750mA/m^2$. After completion of electrochemical treatment, the extraction of chloride ions was quantified and repassivation of steel was observed. Simultaneously, the equated levels of current density for 2 weeks were applied to fresh concrete. Steel-concrete interface in concrete was observed by BSE image analysis and the concrete properties in terms of the diffusivity of chloride ions and the resistance of steel corrosion was measured. As the result, electrochemical treatment is very effectiveness to rehabilitate the passive film on the steel surface and 63-73% of chloride ions in concrete were extracted by the treatment. As the treatment was applied to fresh concrete, the resistance of steel corrosion was improved due to the densification of $Ca(OH)_2$ layers in the vicinity of steel. However, an increase in the current density resulted in an increase in surface chloride content of concrete.

The Effect of Current on Characteristics of Stellite 12 Alloy Overlayer by PTA Process (PTA법에 의한 스텔라이트 12 합금 육성층의 특성에 미치는 전류의 영향)

  • Jung, B.H.;Kim, M.K.;Ahan, Y.S.;Kim, M.Y.;Lee, S.Y.
    • Journal of Power System Engineering
    • /
    • v.5 no.3
    • /
    • pp.88-94
    • /
    • 2001
  • Stellite 12 alloy-powders were overlaid on 410 stainless steel valve seat using plasma transferred arc(PTA) process. Variation of the microstructure, hardness, wear and corrosion of overlaid deposit with current change was investigated. The deposit showed hypoeutectic microstructure, which was consisted of primary cobalt dendrite and networked $M_7C_3$ type eutectic carbides. As current increased, the amount of eutectic carbide decreased and its dendritic secondary arm spacing increased. Hardness of the deposit was decreased with increase of current. Stress relief heat treatment at $600^{\circ}C$ for two hours resulted in slight increase of hardness in the deposit and showed uniform hardness distribution in base metal without any hardened layer in HAZ. Specific wear decreased with increase of sliding distance. The deposit of high hardness with a lot of eutectic carbide showed relatively low specific wear. Initial corrosion current density of the deposit in 0.1N sulfuric acid was lower than those of 410 stainless steel, and showed a little variation with PTA current.

  • PDF

고온고습 환경에서 태양전지 모듈의 성능 향상을 위한 연구

  • Kim, Ju-Hui;O, Won-Uk;Bae, Su-Hyeon;Kim, Dong-Hwan;Park, No-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.494.1-494.1
    • /
    • 2014
  • 태양광은 세계적으로 유망한 에너지 중의 하나이며, 태양광 모듈은 실제 옥외 조건에 따라 다르지만 장기 신뢰성과 수명을 보장하기 위해 최소 20년 이상을 안정적으로 작동될 필요성이 있다. 하지만 실제 태양전지는 옥외에 장기 노출됨에 따라 성능이 저하되며, 그 원인으로는 셀 균열, 부식, 접착 강도 손실 및 박리, 그리고 변색 등이 있다. 본 논문에서는 부식으로 인한 성능 저하를 완화하기 위해 희생금속을 이용하여 태양전지 모듈의 성능 향상에 대해 연구하였다. 태양전지는 4 cell 결정질 실리콘 태양전지 미니 모듈을 이용하였고, 희생금속의 영향을 확인하기 위해 두 종류의 시료를 준비하였다. 한 시료에는 Al 희생금속을 태양전지 리본 위에 부착하였으며, 나머지 한 시료는 비교 시료로 Al 희생금속을 부착하지 않았다. 시료는 $85^{\circ}C$ 85%의 상대습도인 고온고습 조건에서 2500시간을 진행하였다. 그리고 2500시간의 고온고습 시험이 진행된 시료의 전기적 특성을 분석하였다. 시험 결과, 희생금속이 없을 경우 28.8%의 출력 저하가 있었으며, 희생금속이 있을 경우 19.3%의 출력 저하가 확인되었다. 또한, 희생금속이 없을 경우, 충실도는 21.5% 감소하였으며, 단락전류 역시 약 6% 정도 감소하였다. 반면, 희생금속이 있을 경우, 충실도는 16.1%로 감소하였고, 단락전류는 거의 변화가 없었다.

  • PDF