• Title/Summary/Keyword: 부식저항성

Search Result 313, Processing Time 0.038 seconds

Resistance to Corrosion of Reinforcing Steel and Critical Chloride Content of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 저항성 및 임계 염화물량)

  • Lee, Hyun-Jin;Bae, Su-Ho;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.375-381
    • /
    • 2017
  • Recently, due to the increasing of interest about the eco-friendly concrete, it is being increased to use concretes containing by-products of industry such as fly ash, ground granulated blast furnace slag, silica fume, and etc. Especially, these are well known for improving the resistance to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance to corrosion of reinforcement and critical chloride content of high volume fly ash concrete(HVFAC) which is replaced with fly ash for approximately 50% cement content. For this purpose, corrosion monitoring of reinforcement by half cell potential method was carried out for the cylindrical test specimens that the upper of reinforcement in concrete was exposed to detect the time of corrosion initiation for reinforcement. It was observed from the test result that the the time of corrosion initiation for reinforcement of HVFAC by the accelerated corrosion tests increased 1.2~1.3 times than plain concrete and the critical chloride contents of plain concrete and HVFAC were found to range $0.80{\sim}1.20kg/m^3$, $0.89{\sim}1.60kg/m^3$, respectively.

Effect of Ca and Y combined addition on the corrosion behaviors of die-cast AZ91 magnesium alloy (다이캐스트 AZ91 마그네슘합금의 부식거동에 미치는 Ca과 Y 복합 첨가의 영향)

  • Woo, Sang Kyu;Blawert, Carsten;Yi, Sang bong;Yim, Chang dong;Kim, Young min;You, Bong sun;Scharnagl, Nico;Yasakau, Kiryl
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.123.1-123.1
    • /
    • 2016
  • 마그네슘 및 마그네슘 합금은 차세대 경량 구조 재료로서 많은 각광을 받고 있지만, 상대적으로 높은 반응성과 낮은 부식저항성으로 인해 사용에 제한이 있어왔다. 최근 연구결과에 따르면, 상용으로 널리 쓰이는 AZ91 마그네슘합금에 Ca과 Y을 복합 첨가하였을 경우 마그네슘합금의 발화저항성을 크게 향상시키는 것으로 알려져 있어 마그네슘합금의 적용분야를 확대할 수 있을 것으로 많은 기대를 받고 있다. 그러나 이러한 합금이 실제적으로 적용되기 위해서는 반드시 내식성에 대한 평가와 연구가 수반되어야 하며, 이를 통해 부식거동에 대한 메커니즘을 규명함으로써 고내식 합금 개발을 위한 연구로 이어질 수 있도록 해야 한다. 따라서 본 연구에서는 기존의 AZ91D 합금과 Ca, Y이 복합 첨가된 modified AZ91D 합금 다이캐스트 주조재에 대하여 내식성을 평가 및 비교하고 부식 메커니즘을 규명하기 위한 미세조직 분석 및 부식거동 평가를 실시하였다. 본 연구결과에 따르면, AZ91D 합금 주조재에 Ca과 Y을 복합첨가한 합금은 발화저항성 뿐만 아니라 내식성도 크게 향상되는 것으로 나타났다. 이러한 내식성의 향상은 Ca과 Y의 첨가에 따른 Fe와 같은 불순물의 영향 감소 및 Ca과 Y이 포함된 이차상의 형성으로 인한 상과 기지간의 부식 전위의 차이 감소로 인한 미세 갈바닉 부식 발생의 감소 효과에 기인한 것으로 판단된다.

  • PDF

A Study on the Application of FRP Hybrid Bar to Prevent Corrosion of Reinforcing Bar in Concrete Structure (콘크리트구조물 중의 철근 부식 저감을 위한 FRP Hybrid Bar의 적용성 연구)

  • Lee, Seung-Tae;Park, Kwang-Pil;Park, Ki-Tae;You, Young-Jun;Seo, Dong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.559-568
    • /
    • 2019
  • Recently, the infrastructure of the marine environment has been increasing. Therefore, there has been increasing interest in increasing the durability of structures. The FRP Hybrid Bar with improved durability against corrosion was developed in recent years. On the other hand, studies that evaluate the corrosion resistance are insufficient. In this study, the corrosion resistance according to the type of rebar in concrete was assessed and analyzed. The experiment used steel bars and FRP Hybrid Bar. The corrosion test method was a galvanic current and half-cell potential method. The accelerated corrosion test was carried out by four levels (0%, 1.5%, 3%, and 6%) of chloride added to the concrete. The galvanic current measurements revealed no corrosion current in the FRP Hybrid Bar. The half-cell measurement also showed the corrosion resistance of the FRP Hybrid Bar. Therefore. FHB can be used as an alternative steel for structures where a marine environment and steel corrosion are predicted.

Evaluation on Performance of Surface Protectors for Protecting Reinforced Concrete Structures (철근 콘크리트 구조물을 보호하기 위한 표면 보호재의 성능 평가)

  • An, Young-Ki;Jang, Suk-Hwan;Chung, Young-Jun;Nam, Yong-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.217-223
    • /
    • 2005
  • This study is on the evaluation of three kinds of surface protectors for protecting reinforced concrete against corrosion of reinforcing steel by chloride attack and carbonation. In this study, the test has been carried out on the performance of specimens applied with surface protectors for anti-corrosion and anti-carbonation. The result showed that specimens applied with the three kinds of surface protectors, were excellent in resistance to the corrosion of reinforcing steel and carbonation. Especially the specimen applied with finish coating in conjunction with hydrophobic primer showed great reduction in the corrosion of reinforcing steel and carbonation.

Improvement on the Corrosion Resistance and Stress Corrosion Cracking of Ultra-high Strenght AISI 4340 Steel (초강인 AISI 4340 강의 부식 저항성 향상 및 응력부식균열)

  • Hong, Won-Sik;Park, Gyeong-Sun;Lee, Sang-Yul;Kim, Gwang-Bae
    • Korean Journal of Materials Research
    • /
    • v.6 no.9
    • /
    • pp.885-899
    • /
    • 1996
  • 초강인 AISI 4340강을 85$0^{\circ}C$에서 2시간 동안 오스테나이징 처리 후 수냉하고, 250, 400, $600^{\circ}C$에서 각각 2시간 동안 템퍼링 처리를 하였다. AISI 4340강의 인장 특성은 상온에서 측정되었다. AISI 4340강 위에 니켈 전해도금된 것과 도금되지 않은 시편의 분극 특성이 3.5wt%NaCI 수용액과 인공해수에서 측정되었다. AISI 4340강위에 니켈 전해도금된 시편은 500mV(vs. Ag/AgCI)이하의 전위에서 부식 저항이 크게 향상되었다. 그러나 1A/$\textrm{cm}^2$의 전류밀도에서 30분 이상 니켈 전해도금된 시편은 도금층에 불순물과 기공이 형성되었기 때문에 AISI 4340강의 부식 저항은 감소되었다. AISI 4340강의 수소취화형 응력부식균열을 여러 작용 응력과 음극인가전력에서 U-bend 시편을 이용하여 IN 3.5 wt% NaCI 수용액에서 조사되었고, 수소취화형 응력부식균열 거동은 주사전자현미경으로 조사되었다.

  • PDF

A Study on Corrosion Inhibitors for applying to Iron objects (철제유물의 부식억제를 위한 부식억제제에 관한 연구)

  • Kim, Hye Sun;Hur, Yoon Hyun;Kim, Soo Ki
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • Stabilization of iron artifacts is focused on desalination than corrosion inhibitors. However artifacts are not condition of desalination treatment must be applied to corrosion inhibitors. But iron artifacts is not representative of inhibitors which drug is most effective qualities have not been identified. Therefore in this study validates the effectiveness of existing inhibitors and its purpose is to suggest corrosion inhibitors for iron artifacts. In this study, Comparative experiment of corrosion inhibitors is selected BTA, DAN and MEA, TEA. This study was studied using Corrosion resistance test, Contact angle, XPS. As a result, all the samples treated with corrosion inhibitors was formed hydrophobic coating and was rising corrosion resistance. Also, the concentration of corrosion inhibitors was 3% better than 0.3%. BTA in the XPS experiment, the corrosive material to block the CH bond of the peak concentration was highly. This is considered corrosion potential is very high to see out the effect in the polarization experiment. Ethanolamine was superior to the MEA rather than in the TEA. MEA is likely to be appropriate in an outdoor iron artifacts seem to be suitable as corrosion inhibitors.

[특별세션: 다기능성 나노박막 및 제조 공정] 원자/나노 복합구조 제어에 의한 다기능성 전자저항막기술

  • Sin, Yu-Ri;Gwak, Won-Seop;Gwon, Se-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.504-504
    • /
    • 2011
  • 최근 디지털 프린팅 기술의 핵심기술로 떠오르고 있는 잉크젯 프린팅 기술은 최근 기존의 문서인쇄 뿐 아니라, 직물 인쇄, 태양전지 등의 다양한 반도체 소자 제조에 널리 활용되고 있으며, 점차 그 응용 분야를 넓혀가고 있다. 특히 thermal 방식의 잉크젯 피린팅 기술은 etching, thin film process, lithography등의 반도체 공정 기술을 이용하여 제작할 수 있기 때문에, 현재 잉크젯 프린팅 기술은 대부분 thermal 방식을 체택하고 있다. 이러한 thermal 잉크젯 프린팅 방법에서는 잉크를 토출시키기 위하여, 전기적 에너지를 열에너지로 전환하는 전자저항막층이 필수적으로 필요하게 되는데, 이러한 전자저항막층은 수백도가 넘는 고온 및 잉크와 접촉으로 인한 부식 및 산화 문제가 발생할 수 있는 열악한 환경에서 사용되므로, Ta, SiN과 같은 보호층을 필수적으로 필요로 한다. 그러나 최근 잉크젯 프린터의 고해상도 고속화, 대면적 인쇄성 등과 같은 다양한 요구 증가에 따라, 잉크젯 프린터의 저전력 구동이 이슈로 떠올라 열효율에 방해가 되는 보호층을 제거할 필요성이 제기되고 있다. 지금까지는 Poly-Si, $HfB_2$, TiN, TaAl, TaN 0.8 등의 물질들이 잉크젯 프린터용 전자저항막 물질로 연구되거나 실제로 사용되어져 왔으나, 이러한 물질들을 보호층을 제거하는 경우 쉽게 산화되거나, 부식되는 문제점을 가지고 있다. 따라서, 기존 전자저항막의 기능을 만족시키면서, 산화나 부식에 대한 강한 내성을 가져 보호층을 제거하더라도 안정적으로 구동이 가능한 하이브리드 기능성(히터 + 보호층)을 가지는 잉크젯 프린터용 전자저항막 물질의 개발이 시급한 실정이다. 본 연구에서는 자기조립특성을 가져 정밀제어가 가능한 원자층증착법(Atomic Layer Deposition)을 이용하여 원자/나노 단위의 미세 구조 컨트롤을 통해 내열 내산화 내부식성 저온도저항계수를 동시에 가지는 다기능성 전자저항막을 설계 및 개발하고자 하였다. 전자저항막 개발을 위하여 우수한 내부식 내산화성을 가지고 결정립 크기에 따른 온도저항계수 조절이 가능한 platinum group metal들과 전기 저항 및 내열성 향상을 위한 물질의 복합구조막을 원자증증착법으로 증착하였다. 또한, 전자저항막 증착시 미세구조와 공정 변수가 내부식성, 내산화성, 그리고 온도저항계수에 미치는 영향을 체계적으로 연구하여, proto-type의 inkjet printhead를 구현하였다.

  • PDF

Evaluation of Corrosion Resistance using Electro-chemical Methods for the High-Durability Concrete exposed to Marine Condition (해양환경에 노출된 고내구성 콘크리트의 전기화학적기법을 이용한 부식저항성 평가)

  • Yang, Eun-Ik;Kim, Myung-Yu;Lee, Dong-Gun;Han, Sang-Hun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.320-328
    • /
    • 2007
  • The durability of marine concrete structures is severely degraded by corrosion due to seawater attack and diffusion of chloride in concrete. The deduction of durability causes high repair cost for maintenance of marine concrete structure. So, the applicability of high-durable materials is investigated to improve the durability in marine concrete structures. For these, the characteristics of corrosion prevention of marine concrete structures mixed with the mineral admixtures(SF, FA and BFS), the modified steel(stainless and coating steel), and corrosion inhibitors are evaluated using electro-chemical methods. As a results of this study, it is quantified for the effect of promotion of durability by high-durability materials in marine concrete structures.

Evaluation of Anti-Corrosion Performance of FRP Hybrid Bar with Notch in GGBFS Concrete (GGBFS 콘크리트에 매립된 Notch를 가진 FRP Hybrid Bar의 부식저항성 평가)

  • Oh, Kyeong-Seok;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.51-58
    • /
    • 2016
  • Concrete structure is a construction material with durability and cost-benefit, however the corrosion in embedded steel causes a critical problem in structural safety. This paper presents an evaluation of chloride resistance and pull-off performance with various corrosion level. For the work, OPC(Ordinary Portland Cement) concrete and GGBFS(Ground Granulated Blast Furnace Slag) concrete are prepared with normal steel. Artificially notch induced FRP Hybrid Bar is also prepared and embedded in OPC concrete and accelerated corrosion test is performed. Through the test, FRP Hybrid Bar with notch is evaluated to have insignificant effect on pull-off capacity when corroded steel shows only 21% level of pull-off capacity. Furthermore GGBFS concrete with normal steel shows over 70% level of pull-off capacity due to reduced corrosion currency.