Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members (송전철탑 부재 부식열화 검사장비 개발)

  • Woo, Sang-Kyun;Youn, Byong-Don;Kim, Ki-Jung;Chu, In-Yeop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.77-83
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

Corrosion Measurement Method Using Thermographical Information (열화상 정보를 이용한 부식률 예측기법)

  • Yun, Ju-Young;Chung, Lan;Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.142-147
    • /
    • 2007
  • In order to measure corrosion level of steel reinforcement rebar which is inside reinforced concrete structure, infrared thermographic technique was employed. Experimental test parameters were four different ambient temperatures and various levels of corrosion states (0, 1, 3, 5, 7 and 10% of weight loss). After analysis of temperature distributions of concrete surface, the amount of heat flux from the concrete surface is directly proportional to the corrosion level which is inside of concrete.

Material Degradation and Life Assessment in Mechanical Equipment and Structure (기계.구조물의 경년열화와 수명평가기술)

  • Kim, K.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.129-144
    • /
    • 1999
  • 플랜트와 같은 장치산업은 내구성 구조물이므로 사용중에 열화가 발생하는 것은 필연적이다. 특히 고온, 고압의 부식환경하에서 사용되는 설비는 손상이 심하므로 가동중에 돌발적인 고장이 발생하여 플랜트의 가동을 중지하거나 파손사고가 일어나 생산손실은 물론 경우에 따라서는 안전사고의 발생, 환경오염 등 사회적인 문제를 일으키므로 이들 설비의 경년열화 실체를 충분히 이해하고 대책을 수립하는 것은 대단히 중요하다. 따라서 본고에서는 장치산업에서 발생하는 열화현상(재료의 연화, 경화 및 취화, 크리프, 피로, 부식, 마모 등)중 손상의 주류를 이루는 연화, 경화 및 취화, 크리프 피로에 대하여 기본적인 손상기구(damage mechanism)와 비파괴적 진단 및 평가 방법에 주안점을 두어, 현재 국내의 각종 플랜트 진단에 실용화된 기술을 해설하여 이 분야에 종사하는 관계자 여러분의 이해에 조금이라도 기여코자 한다.

  • PDF

Corrosion Level Measurement Technique for RC Reinforcement Using Non-Destructive Test Methods (비파괴기법을 이용한 철근 콘크리트 벽체 철근의 부식률 예측기법)

  • Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux.

An Experimental Study on a Solenoid Eddy Current Sensor to inspect Deteriorations in Overhead Distribution Lines (가공 배전선의 열화를 검출하기 위한 솔레노이드 와전류 센서의 실험적 연구)

  • 김성덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 1999
  • This paper deals with an experirrental study of a nondestructive testing system using a solenoid eddy currnet sensor to inspect deteriorations in overhead distribution lines, such as broken wires, severe local corrosion or zinc loss. Corrosion rrechanisrn for ACSR and ACSR-OC is discussed and characteristics for a solenoid sensor to insprt the georretrical pararreters of the coil and testing materials impOOance are briefly analyzed. A measurement system having a constant current source, a signal processing unit and a motor driver is impIemented. This instrument has such capabilities as detecting the sensor output and estimating dinHlsions of the testing conductors, continuously. As a result, it was shown that the eddy current sensor with an encircling coil could effectively estimate the diatreter change due to deteriorations in overhead distribution lines. lines.

  • PDF

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Assessment of Pipe Wall Loss Using Guided Wave Testing (유도초음파기술을 이용한 배관 감육 평가)

  • Joo, Kyung-Mun;Jin, Seuk-Hong;Moon, Yong-Sig
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.295-301
    • /
    • 2010
  • Flow accelerated corrosion(FAC) of carbon steel pipes in nuclear power plants has been known as one of the major degradation mechanisms. It could have bad influence on the plant reliability and safety. Also detection of FAC is a significant cost to the nuclear power plant because of the need to remove and replace insulation. Recently, the interest of the guided wave testing(GWT) has grown because it allows long range inspection without removing insulation of the pipe except at the probe position. If GWT can be applied to detection of FAC damages, it will can significantly reduce the cost for the inspection of the pipes. The objective of this study was to determine the capability of GWT to identify location of FAC damages. In this paper, three kinds of techniques were used to measure the amplitude ratio between the first and the second welds at the elbow area of mock-ups that contain real FAC damages. As a result, optimal inspection technique and minimum detectability to detect FAC damages drew a conclusion.

Evaluation of Corrosion Fatigue Characteristics of 12Cr Steel Using Backward Radiated Ultrasound (후방복사된 초음파를 이용한 12Cr강 부식 피로특성 평가)

  • Kwon, Sung-Duk;Yoon, Seok-Soo;Song, Sung-Jin;Bae, Dong-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.397-401
    • /
    • 2000
  • The corrosion-fatigue characteristics of the 12Cr steel, which is widely used in fossil power plants as a turbine blade material, are evaluated nondestructively by use of the Rayleigh surface wave. In this study, the frequency dependency of the Rayleigh surface wave is investigated indirectly by measuring the angular dependency of the backward radiation of the incident ultrasonic wave in the aged specimens, and then compared to the corrosion-fatigue characteristics. The width of the backward radiation profile decreases as the increase of the aging temperature, which seems to result from the increase of the effective degrading layer thickness. This parameter also shows an inversely proportionality to the exponent, m, in the Paris law which predicts the crack size increasement due to fatigue. The result observed in this study demonstrates high potential of the backward radiated ultrasound as a tool for the nondestructive evaluation of the corrosion-fatigue characteristics of the aged materials.

  • PDF

PWSCC of Alloy 600 components in PWRs-Part 2 (원자력 발전소 Alloy 600 부품의 PWSCC-Part 2)

  • Hwang, Seong Sik
    • CORROSION AND PROTECTION
    • /
    • v.12 no.1
    • /
    • pp.12-23
    • /
    • 2013
  • 원자력 발전소 주요 부품에 사용되는 Alloy 600의 PWSCC 개시와 전파기구를 살펴보고 그 억제 기술을 소개하였다. ○ 균열은 경화된 표면 산화층이 깨질 경우, 입계부식, 공식(pitting), 열처리 또는 물속에 노출되었을 때 일어나는 선택부식(selective corrosion), MnS등 게재물의 용출등에 의해 시작된다. ○ 균열의 전파는 '느린 성장'과 '빠른 성장'으로 구별해 볼 수 있는데 빠른 균열성장은 균열 선단에서의 응력확대 계수(KI)가 균열이 전파하는 임계값(KIscc)을 넘는 경우에 일어난다. ○ Slip Dissolution/Film Rupture Model, Enhanced surface mobility model, Hydrogen assisted creep rupture, Internal oxidation 등의 모델이 제시되어 있으며 Internal oxidation 모델이 여러 실험자료로 잘 뒷 받침되고 있다. ○ PWSCC 억제 방안으로는 부식환경과의 격리 및 보수용접이 대표적이며 부품의 교체를 통한 안전 확보의 방안도 있다. 수소량 조절을 통한 억제 방안도 제시되어 있다. ○ Alloy 600 PWSCC열화 관리 전략프로그램은 결함 발생 가능성이 높은 부위 선정, 우선 순위에 따른 계획적인 검사, 결함이 발견될 경우 완화조치를 취하거나 필요시 교체/보수를 실시하고 그 운영프로그램을 지속적으로 갱신관리하는 방안으로 유지되어야 한다.

25년 장기간 동작된 태양전지 모듈의 열화모드 및 열화메커니즘 분석

  • Park, No-Chang;Han, Chang-Un;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.34.2-34.2
    • /
    • 2011
  • 본 연구에서는 1986년에 국내 섬 지역에 설치된 태양전지 모듈을 대상으로 전기적 특성값의 열화 및 열화 원인에 대한 분석을 실시하였다. 태양전지 모듈의 초기 최대 출력값은 50 W였고, 5인치 단결정 실리콘 태양전지 36개로 구성되어 있었다. 첫째로, 육안 검사를 통해서 태양전지 모듈의 열화 현상을 관찰하였다. 태양전지 모듈의 절연성은 IEC 61215의 기준으로 측정하였다. 태양전지 모듈의 전기적 특성평가를 통해서 최대 출력값의 변화량을 측정하였고, EL(Electroluminescence) 측정을 통해서 태양전지의 열화를 분석하였다. 이를 통해 분석된 주요 열화 모드는 봉지재 (Encapsulant)의 변색(Discoloration) 및 박리(Delamination)현상이었다. 봉지재의 변색된 부분 및 변색되지 않은 부분의 태양광 반사도를 측정한 결과 변색된 부위의 반사도가 증가한 것을 확인하였다. 두번째로 최대 출력전압을 태양전지 모듈에 인가한 상태에서 태양전지 각각의 온도를 T.C (Thermocouple)을 이용하여 측정하였고, 이를 통해서 태양전지의 열화와 온도와의 관계를 분석하였다. 마지막으로 태양전지 모듈의 단면분석을 통해서 봉지재의 박리현상 및 리본와이어의 솔더 접합계면을 관찰하였다. 또한, 봉지재를 제거한 후에 SEM&EDX를 통해서 리본와이어 및 금속전극의 부식현상을 분석하였다.

  • PDF