• Title/Summary/Keyword: 부식액

Search Result 104, Processing Time 0.025 seconds

The Effect of Humic Acids on the Moderation of High Salt Toxicity (부식산(腐植酸)의 식물(植物)에 대한 염분피해(鹽分被害) 완화작용(緩和作用))

  • Lee, Yong-Seok
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.9 no.4
    • /
    • pp.257-260
    • /
    • 1976
  • Corn (Zea may L.) and Algae (Botridium sp.) were grown in the nutrient solution to investestigate the effects of humic substances on the moderation of high salt toxicity. The results are as follows: 1) The addition of small amount of humic substances (5 ppm C) drastically decreased the high salt toxicity of corn growth. 2) The addition of 20ppm humic substances was also decreased the high salt toxicity in algaegrowth. Different concentration of humic substances, however, did not show significant difference in algae yield.

  • PDF

Estimation of Flood-Damage Curve for Evaluating Flood Damage Cost in Downstream Area of Agricultural Reservoir (농업용 저수지 하류의 홍수피해액 산정을 위한 침수피해곡선 산정기법)

  • Kang, Boo-Sik;Ryu, Seung-Yeop;Kim, Seong-Joon;Lee, Joo-Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1827-1831
    • /
    • 2010
  • 국내의 저수지 비상대처계획수립은 저수용량 100만$m^3$이상의 중 대규모의 댐 및 저수지를 대상으로 수립되고 있다. 반면, 전국 14,208개의 시 군 구 지자체관리 저수지 가운데 80% 이상을 차지하고 있는 30만$m^3$ 미만의 중 소규모 저수지에 대해서는 피해규모의 정량화 방안이 체계적으로 구축되어 있지 못한 실정이다. 이에 본 연구는 중 소규모 농업용 저수지의 붕괴로 인하여 하류부에서 발생하는 피해를 산정하고, 잠재적인 피해액을 예측할 수 있는 홍수피해액 산정방법을 연구하고 인명 및 재산피해를 추정하는 기법을 연구하였다. 홍수피해액 산정에 대한 연구는 1970년대에 치수경제성 분석의 필요성이 대두되면서 원단위법(1993, 건설부, 하천시설기준), 회귀분석법(2001, 건설교통부, 치수사업 경제성분석 개선방안 연구), 다차원법(2004, 건설교통부, 치수사업 경제성분석 연구 방법) 순으로 발전되어 왔다. 원단위법과 회귀분석법의 문제점을 보완하기 위하여 다차원법이 제시되었지만 사용하는 자료가 방대하고 실제 가용성이 제한적인 자료를 포함하고 있어서 적용성이 떨어지는 단점을 가지고 있다. 본 연구에서는 중 소규모의 농업용 저수지 붕괴로 인한 홍수범람시의 피해액산정을 위하여 기존의 원단위법과 다차원법의 장점을 취하여 침수피해추정곡선법(IDEM : Inundation Damage Estimation Method)을 적용하였다. 인명손실액, 이재민피해손실액, 건물피해액, 건물내용물 피해액, 농작물 피해액, 농경지피해액, 공공시설물 피해액으로 구분하고 현재 제공되는 통계자료와 GIS 기법을 이용하여 대상 저수지인 창리저수지의 붕괴에 따른 소규모 범람구역의 침수심별 홍수피해액을 산정 후 침수심-피해액 곡선을 작성하였다. 창리저수지의 경우 저수지 붕괴시 0.4m의 침수심부터 제내지의 침수피해가 발생함을 알 수 있었으며, 침수심-피해액 곡선을 이용하여 침수심별 피해규모를 예상할 수 있었다. 향후 다양한 저수지에 적용성을 검토하여 국내 중 소규모 농업용 저수지 붕괴에 따른 홍수피해액 산정에 이용될 수 있을 것으로 판단된다.

  • PDF

A Study on the Crevice Corrosion for Ferritic Stainless Steel (페라이트 스테인리스강의 틈부식에 대한 연구)

  • Baik Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.51-54
    • /
    • 2004
  • In recently days, the breed fish farm is increased in the beach side for farming fish. In such a farm, the heater is requested for preventing freezing in cold season. The heating material are requested high corrosion resistance and strength for endurance high corrosive salt and pressure. In case of low corrosion resistance and/or strength, the heating element shall be broke down and eventually make spillage or leaking contaminated salt. In the most cases, crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. In this study, the crevice corrosion of Ferritic type 430 stainless steel is investigated. The size of specimen is $15{\times}20{\times}3mmt$. Test solution is 1N H2SO4 + 0.05N NaCl. The artificial crevice gap size is $0.24{\times}3{\times}15mmL$. Crevice corrosion is measured under applied voltage 300mV(SCE) to the external surface. the result of this study showed that 1) the induced time for initiation of crevice is 750seconds, 2) potential is dropped in the crevice from the top of gap opening from -320 to -399mV. The result confirmed that the potential drop(IR mechanism) in the crevice is one of mechanism for crevice corrosion.

  • PDF

Electrochemical Corrosion Characteristics of Dental Prostheses High-Palladium Alloys (치과용 고-Pd계 합금의 부식특성)

  • 김기주;이진형
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.511-518
    • /
    • 2001
  • In vitro corrosion resistance of the commercially used 76.5wt.%Pd-17.6%Cu-7.2%Ga and 77.3%Pd-6.0%Ga dental Prostheses high-Palladium system alloys in cast, degassing and porcelain-firing heat treatment conditions were evaluated by the potentiodynamic polarization technique in the de-aerated 0.9%NaCl and a modified Fusayama electrolyte. From the corrosion rate experimental results, we found that there is a small difference in the corrosion resistance depending on the microstructure. However. it was so small that there is no significant problem as a dental material. The 77.3%Pd-6.0%Ga showed better corrosion resistance than the 76.5%Pd-11.6%Cu-7.2%Ga dental Prostheses high-palladium system alloys. These experimental observations in 76.5%Pd-11.6%Cu-7.2%Ga alleys are mainly due to a rapid quenching and Cu in the alloy which accelerate the eutectic reaction with a segregation and Precipitates in the microstructure. On the ocher hand, 77.3%Pd-6.0%Ga alloys, which are solid-solution matrix, show much better col·lesion resistance compared with that of 76.5%Pd-11.6%Cu-7.2%Ga alloys.

  • PDF

Effect of Si on the Corrosion Properties of Mg-Li-Al Light Alloy (경량화 Mg-Li-Al합금의 내식성에 미치는 Si의 영향)

  • 김순호
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.52-57
    • /
    • 1998
  • Effect of Si in the electrochemical corrosion characteristics of Mg-Li-Al light alloy has been investigated by means of potentiodynamic polarization study. The elecrochemical behaviors were evaluated in 003% NaCl solution and the solution buffered with KH$_{2}PO_{5}{\cdot}$NaOH at room temperature. It was found that the addition of very small quantity of Si (0.48 wt%) in Mg-Li-Al light alloy increased corrosion rates and amount of corrosion products and decreated the pitting resistance of the alloy. From the results it was concluded that Si which is added to increase the strength of Mg-Li-Al alloy is harmful to corrosion properties of the alloy.

  • PDF

Fundamental Study on Cathodic Protection and Material Development as Erosion-Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구(2))

  • Lee, Jin Yeol;Im, U Jo;O, In Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.92-92
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

Fundamental Study on Cathodic Protection and Material Development as Erosion - Control Methods of Oceanic Centrifugal Pump(2) (해상용 원심펌프 임펠러의 침식억제법으로 음극방식 및 재료개발에 관한 기초연구 (2))

  • 이진열;임우조;오인호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.24-31
    • /
    • 1996
  • Recently, with the rapid development in the oceanic systems such as the oceanic structures and vessel, there occurs much interest in the impingement erosion-corrosion. In this paper, Cu-metal was tested by using of erosion apparatus with water-jet type and was investigated under the behaviour of impingement erosion-corrosion according to various environmental conditions, and the properties of Cu-metal were evaluated through the measurement by weight loss, weight loss rate, protective efficiency. The results were compared with those obtained using Cu-metal applied to cathodic protection and Cu-alloys added to Zn or Al-metal. As a basis of those results, the best protective efficiencies could be taken as using cathodic protection method and Cu-alloy with Al & Zn material addings, and will be suggested as the fundamental data of the anti-impingement erosion-corrosion on Cu-metal of impeller material for oceanic centrifugal pump.

  • PDF

Effect of the Corrosive Solution Conditions and Scan Rate to the Electrochemical Corrosion on the AISI 304 Stainless Steel (부식액의 조건 및 주사 속도가 AISI 304 스테인리스강의 전기화학적 부식에 미치는 영향)

  • 나은영;백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.5
    • /
    • pp.535-541
    • /
    • 1997
  • The effect of concentration of each solution( HCI, $H_2SO_4$ and $HNO_3$), scan rate and polished surface condition on the corrosion of AISI 304 Stainless Steel were investigated, utilizing the Method ASTM G5 - 87. It can be concluded that: 1) For the same concentration(i.e. 1N) of each solution the corrosion rate is the highest in HCI and lowest in $HNO_3$. Also, the difference of values of $i_{cirt}$ generated for each solution is significant. 2) As the concentration of the solution $H_2SO_4$ is increased (O.5N, 1N, 2N) the values of $E_{cor}$ $i_{crit}$ and $i_{p}$ are increased. 3) In case of existence of SCN ion of O.OlN, the values of iCTIt and ip generated are approximately 100 times and 1.4 times higher respectively, than in the case of non - existence of $SCN^{-}$. However the existence of $SCN^{-}$ doesn't affect the value of $E_{cor}$ and $E_{p}$. 4) The values of $i_{crit}$ and $i_{p}$ are increased due to the increase of scan rate. But the values of $E_{cor}$ and $E_{p}$ do not depend on the scan rate. 5) The $i_{p}$ value depends greatly on oxygen in the solution, but the changes in values of $E_{cor}$ $i_{crit}$ and $E_{b}$ due to the oxygen are insignificant. 6) If a component is polished using #400, #600 and #800 wet polish paper, the effect of surface condition on variations of values of $i_{crit}$ and $i_{p}$ is slightly significant.

  • PDF

Convergence Study on FTO Film Etchant (FTO 필름 식각액에 관한 융합연구)

  • Han, Doo-Hee;Yang, Ui-Dong
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.43-48
    • /
    • 2018
  • An etchant capable of forming a circuit in an FTO film that can replace ITO, which depends on full imports, was prepared. The etching solution is composed of 1 to 30% by weight of fluoride, 1 to 20% by weight of acid, 0.5 to 5% by weight of surfactant, 5 to 20% by weight of solvent, 0.5 to 10% by weight of corrosion inhibitor and the balance of water. This etchant can be etched using a dry film, thereby reducing the cost, and is free from bubbles and residue of the etchant. The characteristics of the etchant were etched in a time of 2 minute with a 100 nm thick FTO, and the etchant temperature was maintained at $50^{\circ}C$. An undercut of -0.00364% was obtained when put into a 2 minute etching solution. No harmful substances such as Cd, Pb, Hg and Cr components were measured. The use of FTO in Korea where rare earths do not exist can achieve localization and import substitution effect.

THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES (차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구)

  • Yang, Won-Kyung;Ra, Yoon-Sik;Lee , Young-Kyoo;Son, Ho-Hyun;Kim, Mi-Ri
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.121-127
    • /
    • 2005
  • A variety files made of stainless steel (S-S) or nickel-titanium (Ni-Ti) are used during endodontic treatment. The purpose of tt)is study was to evaluate the corrosion susceptibility of S-S and Ni-Ti endodontic files. Three brands of files were used for this study: $K-flex^{(R)}$ S-S files (Maillefer, USA), $Profile^{(R)}$ Ni-Ti files (Maillefer, USA), $K-3^{(R)}$ Ni-Ti files (SybronEndo. USA). 120 files of each brands (21mm, ISO size $\#20$) were divided into 12 groups according to 1) sterilization methods using Autoclave or Ethylene Oxide (E-O) gas, 2) Irrigation solutions using $5.25\%$ NaOCl or Saline, 3) the number of sterilization (1, 5, 10 times), After above procedures, each of the files was inspected by three examiners with a light microscope and camera at X25. Each file was judged and ranked according to the following criteria: 0;, no corrosion, 1; mild corrosion, 2; moderate corrosion, and 3; severe corrosion. The files of high score were examined under the Scanning Electron Microscope. Data were statistically analyzed with the Kruskal-Wallis test (p < 0.05). Most of the ten time-autoclaved files had showed mild to moderate corrosion. But, one or five time-autoclaved files did not show corrosive surface. NaOCl treatment and E-O gas sterilization did not influence on corrosion. There was a significant difference in corrosion susceptibility between sterilization methods and the number of autoclaving. However, there was no significant difference between brands and file materials.