• Title/Summary/Keyword: 부식성 수질

Search Result 52, Processing Time 0.031 seconds

The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America (상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황)

  • Kim, Minhee;Hyun, Seunghun;Lee, Won-Seok;Loretta, Y. Li
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Modified indirect evaluation method for deterioration assessment of drinking water pipes (상수도 노후도 평가를 위한 수정 간접평가법)

  • Kwon, Hyuk Jaea
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.697-703
    • /
    • 2023
  • In this study, a modified indirect evaluation method was developed to predict the deterioration level of water pipes. The accuracy of the modified method was verified by comparing it with the direct method. The weights of index were adjusted by reducing the weight of water quality corrosion, soil corrosion, lay depth and road type according to the importance of the existing evaluation factors and adding the weight of pipe thickness. In the results, the weight of pipe thickness was determined to be 0.1530. Comparing with the direct evaluation method, the accuracy of the modified indirect evaluation method increased by 31.03% compared to the indirect evaluation method. The modified indirect evaluation method will be able to select relatively old pipes more accurately and efficiently than the existing indirect evaluation method when prioritizing the improvement of old water pipes.

Introduction of Corrosion Index System for Stability of Drinking Water Quality (음용수질의 안정성을 위한 부식지수제도의 도입)

  • Kim, Yeong-Kwan;Kim, Jin-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

Prediction of Water Quality Effect of Watershed Runoff Change in Doam Reservoir (유역유출 변화에 따른 도암댐 저수지 수질 영향 예측)

  • Noh, Hee Jin;Kim, Jung Min;Kim, Young Do;Kang, Boo Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.975-985
    • /
    • 2013
  • In this research, the integrated modeling system by coupling of a watershed model, a reservoir model, and a river model has been constructed in Doam reservoir watershed. Because of domestic climate characteristics, it is inevitable to construct the dam for control of flood, water use, and power production due to the heavy rain in the summer. Especially, when the dam is constructed on the stream for these kinds of purpose, it is necessary to consider this region as one watershed and also to make the integrated system for simulation and management. In this study, SWAT model was constructed for watershed modeling and EFDC-WASP model was constructed for simulating the hydrodynamic and water quality of the reservoir and the downstream in Doam dam watershed. Also, the water quality improvement equipment for demonstration was applied in the upstream part of Doam reservoir, which shows the applicability of the developed integrated modeling system.

Research on Improvement of Lake Water Quality Using Artificial Floating Island (호소 수질 개선을 위한 인공식물섬 장치 개발 연구)

  • Kim, Tae-Hoon;Ahn, Tae-Woong;Jung, Jae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.263-270
    • /
    • 2010
  • This is a research on development of water purification equipment called artificial floating island (=AFI) for the stagnant water area which can secure exuberant landscape and water-friendility. The equipment devised in this study is designed to make up the weakness of conventional AFIs and improves the removal efficiency of pollutants using the mixture of media and plants. The air compressor positioned at the inlet releases air with inflow continuously, the water pump at the outlet sprays as a form of fountain with causing a disturbance on stable water column, then, both of them contribute improvement of water quality over a large area. We applied Bio-stone as a media in this system and performed an experiment of pre-efficiency test, and we concluded that the higher pollutants concentration of inflow, the higher removal efficiency we obtained. At the result of lab-scale experiment, in the case of high-concentration inflow, in the removal efficiency of SS is 62.2%, BOD is 50.2%, COD is 55.1%, T-N is 31.6%, T-P is 38.4%. In addition, to evaluate the field application, we set up the facilities in Sin-gal lake located in Yongin-Si Gyeonggi-Do, and researched on the removal efficiency of outflow relative to the inflow. As a result, SS is 53.5%, BOD is 32.8%, COD is 36.9%, T-N is 22.6%, T-N is 33.2%.

A Study on the Floating Island for Water Quality Improvement of a Reservoir (저수지 수질개선을 위한 인공식물섬 조성에 관한 연구)

  • Lee, Kwang-Sik;Jang, Jeong-Ryeol;Kim, Young-Kyeong;Park, Byung-Heun
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.77-82
    • /
    • 1999
  • Three floating islands have been constructed for water quality improvement for a polluted irrigation reservoir. Each floating island consists of 10 segments. Each segment hay an area of $16m^2$(4×4m) and is made of wood frames and floats(polystyrene foam). We planted three species of aquatic macrophytes(Typha angustifolia, Zizania latifolia, and Phragmites australis) in floating island on June, 1998. They grew very well without death. We would like to evaluate Phragmites australis is the most suitable aquatic macrophyte that could be planted in a floating island because it maintained the best balance of its root and shoot among them. During their grown period, net primary productivity of Typha angustifolia was $962gDM/m^2$, Zizania latifolia was $1,115gDM/m^2$, and Phragmites australis was $523gDM/m^2$. From these data, it would be estimated to 5.0Kg uptake of nitrogen by aquatic macrophytes and phosphorus 0.8Kg in 3 floating islands. The floating islands worked well as a habitat of fish and prawns. Many kinds of insect lived on the floating islands. The floating island has not only the function of water quality treatment but also several advantages: improvement of landscape and species diversity; low cost of maintenance; low technology; unnecessary of energy; less susceptible to variations in pollutant loading. It could be evaluated a good measure of water quality improvement for an irrigation reservoir. However, it should be intensively studied to develop more light, strong, durable and low-priced frames for efficient floating islands.

  • PDF

Effect of Change in Hydrological Environment by Climate Change on River Water Quality in Nam River Watershed (기후변화에 따른 남강유역의 수문환경의 변화가 하천수질에 미치는 영향)

  • Kang, Ji Yoon;Kim, Young Do;Kang, Boo Sik
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.873-884
    • /
    • 2013
  • In Korea, the rainfall is concentrated in summer under the influence of monsoon climate. Thus, even a small climate change can be significant problems in water resources. As a result, a lot of attention has been focused on climate changes and a number of researches have been conducted in a manner commensurate with the attention to the climate change. This study is intended to forecast the changes in the flow and water quality of the Nam river resulting from the future climate changes in the Nam river basin using a watershed and water quality model. An SWAT model, as a watershed hydrologic model, was established after estimating a climate scenario using an artificial neural network method, and the established model was verified and adjusted using date from the Ministry of Environment to evaluate the applicability of the model. As a consequence, $R^2$ showed more than 0.7 in the simulation test, which satisfies the minimum required level. Results from the SWAT model and the future Namgang dam discharge calculated by HEC-ResSIM is used as input date for QUALKO. The results showed a huge variation in BOD depending on the annual flow of the river, which recorded a maximum difference of 2 mg/L between a rainy season and a dry season. It can be deduced that because rainfall and the runoff of a basin significantly account for the water quality of a river, higher water concentrations are recorded in a dry season in which the flow is not as much as that in a rainy season. It also can be said that water should be reserved in advance to secure water in the Nam river downstream for a dry season and be controlled in an effective and efficient manner to provide better water quality.

Body Residue-based Approach as an Alternative of the External Concentration-based Approach for the Ecological Risk Assessment (외부환경농도에 기반한 생태위해성 평가방법의 대안으로서 생체잔류량 접근법)

  • Lee Jong-Hyeon
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.2 s.53
    • /
    • pp.185-195
    • /
    • 2006
  • 환경오염물질로부터 수생태계 보호를 위한 표준적인 평가 및 관리 수단인 수질환경기준은 오염물질의 독성작용이 일어나는 표적기관에서의 오염물질의 농도에 대한 대체측정치로서 환경 내 오염물질의 농도를 이용해 왔다. 이러한 '외부환경농도에 기반한 접근방법'은 표적기관에서의 독성물질의 농도가 생물체내 농도에 비례하고, 결국 외부환경농도에도 비례할 것이라고 가정한다. 따라서 환경오염물질의 생물이용도나 생물축적 양상의 차이 때문에 고유 독성치를 비교 평가하는데 한계가 있다. 이와 달리 '생물체내 농도에 기반한 접근방법(이하 생체잔류량 접근법)'은 환경오염물질의 생물이용도나 종 특이적 생물축적 양상과 관련된 불확실성을 제거하고, 환경오염물질 고유의 독성을 비교 평가할 수 있게 해준다. 특히 생체잔류량 접근법을 독성동태학 및 독성역학 모델과 함께 사용하는 경우는 실제 현장에서 일어나는 복잡한 노출조건에서의 독성영향을 예측하는데 활용할 수 있다. '생체잔류량 접근법'은 독성기작별 임계잔류량(Critical Body Residue)을 결정함으로써 생물모니터링의 결과를 해석하는데 적용되고 있다. 또한 생태위해성평가를 위해서 필요한 '무영향예측농도(Predicted No-effect Concentration, PNEC)를 예측하기 위한 방법으로 생체 내 잔류량에 기반해서 농도-시간-반응관계를 기술하고, 예측할 수 있는 새로운 유형의 독성역학 및 독성동태학 모델을 제시하고, 생체내 '무영향농도(No Effect Concentration, NEC)'를 추정하게 해 준다. 특히 생체내 NEC는 '무영향관찰농도(No Observed Effect Concentration, NOEC)'와 '영향농도(Effect Concentration, EC)'처럼 분산분석이나 회귀분석모델과 같은 통계적 모델에 기반해서, 농도-반응관계만을 기술할 뿐인 기존 독성모델을 대체할 대안으로 최근에 OECD와 ISO에 의해서 추천되었다.분석을 시행한 결과 인지기능 장애정도 및 MMSEK 점수 증가에 따른 사망위험도는 어느 모형에서도 인지기능 장애정도가 사망에 미치는 위험도는 통계적으로 유의하지 않았다(표 6, 표 7). 이상 본 연구는 농촌지역 노인들에서 인지기능 장애정도가 사망에 미치는 영향을 알아보고자 하였지만, 인지기능 장애정도가 사망에 미치는 영향을 통계적으로 유의하게 고찰하지 못하였다.의한 차이를 보였다. (P<0.05, P<0.001) 5. Excelco로 부식처리된 도재가 5% HF 용액으로 부식처리된 도재보다 부식정도가 더 현저하였다.은 제언을 하고자 한다. 먼저, 학교급식에 대한 식단 작성 시 학생들이 학교에서 제공되기 원하는 식단에 대한 의견을 받고 그 의견에 대한 결과를 게시하여 학생들이 제공되기 원하는 식단을 급식 시 제공하여 학생들이 식단선택에 동참할 수 있는 기회를 주는 것이 바람직하겠다. 또한 영양사는 학급의 반대표와의 정기적인 모임을 가짐으로서 학생들의 불만사항 및 개선 요구사항에대해 서로 의견을 교환하여 설문지조사가 아닌 직접적인 대화를 하여 문제점을 파악하고자 하는 적극적인 자세가 필요하겠다. 특히 아침식사의 결식 빈도가 높았고 이는 급식성과에 부정적인 영향을 줄 뿐 아니라 학교에서 제공하는 음식의 섭취정도에도 영향을 주고 있으므로 학생들에게 학부모와 전담교사 및 학교영양사는 학생들에게 이상적인 아침식사에 대한 교육은 물론이고 아침식사를 실천할 수 있도록 다양한 방안에 대해 함께 연구해야 하겠다. 정부차원에서 학교급식에 아침식사 프로그램을 도입할 수 있는 방안을 연구하고, 아침을 결식하는 학생이 학교에서 수업시작 하기 전에 간단한 식사를 할 수 있는 정책 도입이 필요하다acid의 생성량(生成量)을 측정(測定)하였는데 periodate의 소비량(消費量)은 1.23 mole, formic acid의 생성량(生成量)은 0.78 mole이다.한 경우도 비교적 많이 먹고 있었다(24.3%). 남 여

Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment (공동주택 지하저수조의 수질변화 및 부식성 특성)

  • JunYoung, Jang;JooWon, Kim;YuHoon, Hwang;KiPal, Kim;HyunSang, Shin;ByungRan, Lim
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.