• Title/Summary/Keyword: 부식성 수질

Search Result 52, Processing Time 0.032 seconds

Assessment of External and Internal Corrosion Growth Rate for Metallic Water Pipes (상수도 금속관의 외면과 내면 부식속도 평가에 관한 연구)

  • Bae, Chulho;Kim, Juhwan;Kim, Jeonghyun;Hong, Seongho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 2008
  • In this study, external and internal pit growth rate model and external non-linear regression corrosion model were proposed by measuring pit depths and evaluating various soil factors known to contribute to the corrosion for metallic water pipes. Average pit depths of external and internal for metallic water pipes were measured 1.38 mm and 2.13 mm, and internal pit growth rate also fasted twice than external pit growth rate. This means the corrosion potential of water quality was higher than soil. The corelation between external corrosion rate and each soil corrosion factor was low. However, proposed external non-linear regression corrosion model considering all soil corrosion factors showed a little higher correlation ($R^2=0.46$) than conventional model.

  • PDF

A Study on Water Quality Prediction for Climate Change Using Watershed Model in Andong Dam Watershed (유역모형을 이용한 기후변화에 따른 안동댐 유역의 미래 수질 예측)

  • Noh, Hee-Jin;Kim, Young-Do;Kang, Boo-Sik;Yi, Hye-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.945-945
    • /
    • 2012
  • 본 연구에서는 낙동강 수계의 안동댐 유역을 대상지역으로 선정하여 미래 기후변화 시나리오에 따른 댐 유역의 수환경 영향을 예측해 보고자 하였다. 특히 미래기후에 대한 수환경 평가는 기후자료를 입력 값으로 요구하는 강우-유출모형을 이용하거나 유량 이외에 유사, 영양물질과 같은 수질인자를 동시에 모의할 수 있는 유역모형을 이용하여 평가하는 것이 일반적이다. 이를 위해 선행연구로 IPCC(Intergovernmental Panel on Climate Change)에서 제공하는 AR4 시나리오의 RCM 자료를 ANN(Artificial Neural Network)기법을 이용하여 안동댐 유역의 총 4개 기상관측소에 대한 과거 20년(1991~2010) 실측자료를 바탕으로 미래 강수 및 습도 그리고 온도에 대해 상세화 하여 미래 기후 시나리오를 생산하였다. 또한 안동댐 유역 단위의 수질을 예측하기 위해 토양과 토지이용 및 토지관리 상태에 따른 수문-수질 모의가 가능한 유역모형인 SWAT(Soil and Water Assessment Tool)을 이용하였다. 과거의 기상자료와 수질자료를 이용하여 유역모델의 검 보정을 실시하였으며 모형의 보정 및 검증결과에 따른 적합성과 상관성을 판단하기 위해 결정계수($R^2$)와 평균제곱근오차(Root Mean Square Error, RMSE)를 사용하였으며, 모형의 효율성 검증으로는 Nash and Sutcliffe(1970)가 제안한 모형효율성계수(NSE)를 사용하였다. 최종적으로 기후 시나리오에 대해서 전망된 지역상세기후를 유역모형의 입력자료로 이용하여 안동댐 유역의 미래수문 및 수질을 예측하고자 하였다.

  • PDF

A study on the corrosion characteristics of carbon steel pipes by phosphate corrosion inhibitor (인산염계 부식억제제에 의한 탄소강관의 부식특성 연구)

  • Woo, Dal-Sik;Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.493-499
    • /
    • 2008
  • This study was performed to estimate the water quality parameters on corrosion such as pH, turbidity, Fe released concentration, corrosion rate by using batch reactor for corrosion control of phosphate corrosion inhibitor in carbon steel pipes. The pH, conductivity, alkalinity, and Ca hardness showed a slight change for dosing the phosphate corrosion inhibitor with carbon steel pipe in batch reactor. The turbidity was about ten times lower with 5 mg $P_2O_5/L$ of the corrosion inhibitor than that without. The Fe released concentration and corrosion rate was decreased by about 12.2, 24 times with 5 mg $P_2O_5/L$ of the corrosion inhibitor than that without. In conclusion, the optimum concentration of the phosphate corrosion inhibitor was found to be 5 mg $P_2O_5/L$. The effect of the corrosion inhibitor was significant for the carbon steel plate samples tested in this study. The corrosion inhibitor can be an effective cure for corrosion and red water problem preventing the service pipe from further corrosion.

몰비지수에 의한 증기발생기 틈새수화학 특성평가

  • 나정원;성기운;조영현;김우철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.369-373
    • /
    • 1998
  • 증기발생기에서 부식에 의한 전열관 손상은 전열관과 관판사이의 틈새에서 대부분 발생되고 이 틈새에서의 수질환경에 좌우된다. 틈새에서는 과열도가 높아 미량의 불순물이 농축되면서 틈새수화학 (crevice chemistry)은 증기발생기 내부수 수화학과는 달라진다. 전열관 손상을 억제하기 위해서는 틈새수질을 적절히 제어하여야 하는데 이는 틈새수화학을 정확히 분석평가할 수 있는 기술을 기반으로 하여야 한다. .기존의 틈새수질을 계산하는 방법으로는 증기발생기 내부수에 비해 틈새에서 화학종들이 얼마나 농축되는지를 가정하는 농축도 (concentration factor) 방법이 있으나 가정에 의한 불확실성으로 인해 틈새수질을 정확히 해석할 수 없었다. 그러나 원전 증기발생기의 잠복불순물 방출시험 자료로부터 틈새수질을 보다 정확히 평가할 수 있는 새로운 개념의 몰비지수(molar ratio index) 방법이 최근 EPRI에서 제시되었고 EPRI 산하의 많은 발전소에서 적용중이다. 본 연구에서는 PWR 원전 증기발생기의 틈새수화학을 평가할 수 있는 기술을 개발하기 위해 잠복불순물 방출시험 자료로부터 틈새에서의 몰비지수를 계산할 수 있는 CRAP (CRevice-chemistry Analysis Program) 전산프로그램을 작성하였다 CRAP를 국내원전에 적용하여 증기발생기 및 그 틈새에서의 수화학을 평가하였다.

  • PDF

Characteristics and Improvement of Tap Water Corrosivity in Korea (국내 수돗물의 부식성 특성 및 개선방안)

  • Kim, Jin-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.731-739
    • /
    • 2011
  • To investigate corrosivity characteristics of tap water in Korea, Langelier index (LI) of 30 multi-regional water treatment plants (WTPs) were evaluated. Weekly LI values of 30 WTPs were all negative, which means tap water in Korea might be very corrosive. Maximum LI decrease through water treatment processes was 0.95 under no additional corrosion control process. Based on the correlation results between LI and tap water qualities, pH and calcium concentration were confirmed as major parameters for LI control. Addition of calcium hydroxide with $CO_{2}$ or calcium hydroxide or sodium hydroxide can be chosen based on water quality. Continuous monitoring of LI and related parameters is recommended in water distribution system.

Improvement of tap water corrosivity by lime and carbon dioxide (액상소석회와 이산화탄소를 이용한 수돗물 부식성 개선)

  • Kim, Jinkeun;Lee, Junghoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.725-733
    • /
    • 2014
  • 16 water treatment plants(WTPs) in Jeju province were investigated to evaluate the corrosivity of tap water. In addition, the impacts of lime and carbon dioxide on LI changes at ES WTP were analyzed. The average of LI in Jeju tap was -1.78 which was similar to that of in-land multi-regional WTPs. The recommended process to improve LI of ES WTP which has high corrosivity(i.e., LI = -2.61) was to combine lime and carbon dioxide with the dosages of 20 mg/L and 5 mg/L respectively to meet LI of -1.0 ~ 0. pH was confirmed to be a major water quality parameter that determined LI based on the correlation results among LI and water quality parameters. Precaution on turbidity increase by lime addition should given to minimize particle breakthrough in the distribution system. Turbidity increase can be controlled by the addition of lime prior to filters.

Conceptual Design of Pretreatment Process for SIES Using Membrane Process (막분리 공정을 이용한 SIES 전처리설비 개념 설계)

  • 이상진;양호연;신상운
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.15-20
    • /
    • 2003
  • During operation process of SIES(Selective ion exchange system) at Kori Unit 2, it was impossible to remove radionuclides such as ion form and Ag-110m, etc., because activated carbon and ion exchange resin of this system are fouled easily by suspended solids and oils in liquid radwaste that was flowed in this system. In this study, an experiment to improve quality of water which was flowed in SIES was performed. and design data of Scale-up pretreatment process were secured. Also, each module design for Microfiltration and Nanofiltration unit of the pretreatment process for SIES was performed.

  • PDF

Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime (액상소석회를 이용한 SWRO 생산수의 부식제어 연구)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Kwak, Myung-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.529-536
    • /
    • 2011
  • In this study, we confirmed that the SWRO(Sea Water Reverse Osmosis) production water has more hard corrosiveness than the tap water by fundamental experiment. According to the result, the target of this study was aimed at developing maintenance and anti-corrosion method. In the early stages of the research, batch tests using mild steel coupons and electrochemical experiments were applied to compare the corrosiveness between SWRO production water and the tap water. After then, two corrosion control methods for SWRO production water were applied. Liquid lime($Ca(OH)_2$) and Carbon Dioxide($CO_2$) were inserted and compared with the combination of liquid lime with phosphate corrosion inhibitor and carbon dioxide. The water qualities were evaluated through LSI(Langelier Saturation Index) and proper injection ratio was deduced by the result. Since then, simulated loop system test were performed to evaluate anti-corrosion effect depending on corrosion inhibitors. Subsequently, carbon steel pipes equipped at the loop system were detached for SEM, EDX and XRD analysis to acquire quantitative and qualitative data of the major corrosion products inside the pipes. In conclusion, the controled groups with anti-corrosion techniques applied were effective by appearing 97.4% and 90.9% of improvements in both case of liquid lime and the liquid lime with a phosphate corrosion Inhibitor. furthermore, major components of scale were iron oxides, on the other hand, protective effect of film formation by calcium carbonate($CaCO_3$) could be confirmed.

Effect of Polyacrylic Acid Concentrations to the SA106 Gr.B and Alloy 690 Materials at the Startup Environments of Secondary Water Chemistry of NPP System (원전 기동시 2차측 수질 환경에서 SA106 Gr.B와 Alloy 690 재료에 미치는 고분자 아크릴산 농도 영향)

  • Gwon, Hyeok-Cheol;Lee, Du-Ho;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.118-119
    • /
    • 2014
  • 원전 운전 중 2차계통 구성재료가 부식되어 철 산화물이 증기발생기 내부로 유입된다. 유입된 철산화물은 고온고압의 환경에서 침적되어 슬러지가 된다. 침적된 슬러지는 증기발생기 전열관 재료에 응력부식균열(SCC)을 일으키는 주원인으로 원전에서는 철 산화물의 유입을 최소화하기 위해 기동전 2차계통을 순환 세정하고 있다. 해외 원전에서는 고분자 아크릴산(Polyacrylic Acid)을 순환세정시 주입함으로써 2차계통 철 산화물 제거 효율을 높인 사례가 있었다. 이에 우리 원전에서도 기동전 순환세정시 고분자 아크릴산을 주입 적용하였다. 고분자 아크릴산 주입 전 필수적으로 이뤄져야할 연구는 고분자 아크릴산이 재료에 미치는 영향평가이다. 본 연구에서는 고분자 아크릴산 농도(1, 10, 100 ppm)에 따라 2차계통 구성재료인 SA106 Gr.B와 Alloy 690의 건전성에 미치는 영향를 수행하였다. 평가방법으로는 전기화학 분극실험, 시편을 침지시켜 실험 전, 후 무게 감량을 이용한 부식률 측정, 표면 상태분석등을 이용하여 종합적으로 평가하였다. 전기화학 분극실험과 부식률 측정결과, 고분자 아크릴산 농도가 높을수록 부식은 증가하였고 고분자 아크릴산 농도 100 ppm일 때 최대 부식률이 0.037 mils로 계산되었다. 이는 부식허용 기준치(5.8 mils)보다는 100배이상 낮았으며 표면분석 결과 고분자 아크릴산으로 인한 pitting 부식은 발생하지 않았다. 이와 같은 결과로 기동시 환경에서 고분자 아크릴산 농도 100 ppm까지는 재료 건전성에 미치는 영향은 거의 없는 것으로 판단된다.

  • PDF

A Study on Development of Water Quality Prediction by Artificial neural network in Watershed of Nam River Using Probability Forecast (확률예보를 이용한 남강유역에서의 수질예측 ANN모형 개발 연구)

  • Jung, Woo Suk;Kim, Young Do;Kang, Boo Sik;Kim, Sung Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.26-26
    • /
    • 2017
  • 우리나라는 하천 및 호수 등 지표수에 대한 수자원 의존도가 매우 높다. 지표수는 태양광에 노출되어 있고, 기온의 영향을 직접 받기 때문에 기후변화에 대해 매우 민감한 수체이다. 기후변화로 인한 이상 저온, 이상 고온, 홍수, 가뭄 등의 자연 현상은 하천, 호수의 물리화학적 및 생태학적 특성을 변화(교란)시키고 있다. 이러한 기상현상에 변동되는 수질특성을 고려하여 기상청 확률기상예보를 구축된 인공신경망 예측모형의 입력인자로 적용하여 수질예보시스템을 개발하고자 하였다. 모형구축은 실제 일어난 기상관측자료와 요인분석을 통해 분류한 수질인자를 반영하여 단위유역별 수질예측을 위한 ANN학습을 실시하였다. 각 단위유역마다 기상요인의 공간적 세밀화 적용을 위해 각각 남강A, 남강B는 산청기상대, 남강C, 남강D는 진주기상대, 남강E는 의령기상대 자료를 이용하였으며, 수질항목은 DO, BOD, COD, TOC, T-P, SS 총 6개로 단위유역 5개에서 총 30개 예측모형 구축을 위한 자료를 수집하였다. 학습된 인공신경망 예측모형에 기상청 확률예보 값을 입력인자로 사용하여 모형평가를 실시하였다. 5개 단위유역 중 상대적으로 유역관리의 시급성을 고려하여 남강댐 하류 단위유역인 남강D, 남강E 인공신경망 모형의 입력자료로 적용하여 평가하였다.

  • PDF