Electrochemical characteristics of electric arc sprayed steel using sacrificial anodic wires (희생양극 선재로 아크 용사코팅된 강재의 전기화학적 특성 평가)

  • Park, Il-Cho;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.318-318
    • /
    • 2015
  • 해양환경 하에서 SS400강의 부식 방지를 위하여 Al과 Al-Mg합금 선재를 이용한 아크용사코팅을 실시하였다. 그리고 다양한 전기화학적 실험으로 내식성을 평가하였으며, 실험 후에는 주사전자현미경(SEM)과 3D 현미경을 이용하여 손상된 표면의 형상 및 손상깊이를 상호 비교하였다.

  • PDF

Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete (콘크리트 내부로의 압입공법을 사용한 방청제의 침투깊이 및 농도에 관한 실험적 연구)

  • Cho, Hyeong-Kyu;Yoo, Jo-Hyeong;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.160-168
    • /
    • 2009
  • After steel bar was corroded it removes concrete contaminated, it does steel bar corrosion protection, repairing method and corrosion inhibitor spreading method are difficult to secure corrosion protection performance. Accordingly, in this research before Research and Development to penetrate corrosion inhibitor to high pressure by steel bar position, it measures penetration depth through corrosion inhibitor high pressure penetration experiment and amount of nitrite by position and then it predicts penetration depth in accordance with water-cement ratio, pressure, pressure time and it computed water-cement ratio, pressure, pressure time to be more than 0.6 mol ratio of chloride ion and nitrite to have outstanding corrosion protection performance. As a result of experiment, water-cement ratio gives the biggest influence to penetration of corrosion inhibitor and also the more depth of specimen becomes deep, concentration of penetrated corrosion inhibitor does not equal and becomes low.

An Performance Evaluation of the Post-installed Anchor System According to the Freezing and Thawing of Concrete and the Corrosion of Anchor (콘크리트의 동결융해와 앵커의 부식에 따른 후 설치 앵커시스템의 성능평가)

  • Kwon, Min-Ho;Kim, Jin-Sup;Jung, Woo-Young;Kwon, Sang-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.31-39
    • /
    • 2013
  • In this study, performance of the post-installed anchor system was evaluated with reduced strength of concrete and anchor. One of the post-installed anchors was selected to performance evaluation. Concrete strength was reduced by freeze-thawing test, and the post-installed anchor strength was reduced by corrosion test. The post-installed Anchor was installed in concrete of freezing and thawing and original concrete, and corroded anchor was installed in original concrete only. Anchor diameter and installation depth of the anchor were the variable for each specimen. Performance of post-installed anchor system of each specimen was evaluated by pullout test. Anchor diameter and installation depth of anchor, it may affect the performance of the post-installed anchor system from the experimental test results. Fracture mode of each post-installed anchor system had occurred differently depending on the durability of concrete and anchor. The anchor pullout strength from the experimental test results was used in order to compare with the results of CCD (Concrete Capacity Design) method, and CCD equation was modified. Modified equation was able to predict the anchor pullout strength of post-installed anchor system in Original concrete and freezing and thawing of concrete.

Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Long Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 구조물의 보수재료.공법 성능평가)

  • Kim, Moo-Han;Kim, Gyu-Yong;Cho, Bong-Suk;Kim, Young-Duck;Kim, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • In this study, for the establishment of the performance evaluation methods and the quality control standards of durability recovery method, the quantitative exposure data by long term exposure test under the coast and normal atmosphere is accumulated and analyzed. Investigating and evaluating the result of exposure test during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chloride-ion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of Corrosion of reinforcing bar are chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Therefore, it is considered to be applied as the fundamental data on the performance evaluation and quality control standards of repair material and method through continuous exposure test in the future.

Chloride Diffusion in Hardened Concrete with Concrete Properties and Testing Method (콘크리트 물성 및 시험법에 따른 콘크리트 염화물 확산)

  • Yang Eun-Ik;Kim Myung-Yu;Min Seok-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.261-268
    • /
    • 2004
  • Corrosion of reinforcement is the main cause of damage and early failure of reinforced concrete structures. The corrosion is mainly progressed by the chloride ingress. In this paper, an experimental study is executed to investigate the effect of concrete properties and testing methods on the coefficients of chloride diffusion. Also, it is surveyed the relationship between total chloride and free chloride in concrete. According to this experiment results, W/C ratio and testing method affect chloride diffusion coefficient of concrete. As W/C ratio is increased, diffusion coefficient in concrete is also increased. Diffusion coefficient obtained by each testing method show the different values, respectively. The model equation of diffusion coefficient with W/C ratio is proposed.

Investigation and Evaluation on Performance of Durability for Freeway Concrete Viaducts in Seoul Metropolitan Area (서울시내 위치한 콘크리트 고가차도의 내구성능 조사 및 평가)

  • Lee, Chang-Soo;Yoon, In-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.143-152
    • /
    • 2002
  • The objectives of this paper were to obtain the fundamental data to analyze the causes of deterioration of 39 freeway concrete viaducts in Seoul metropolitan area. To investigate the degree of concrete deterioration, carbonation depth, soluble chloride concentration in hardened concrete and half-cell potentials of reinforcement were measured. The number of structures which carbonation depth penetrates to reinforcement was 25% of total. The model of carbonation .ate was induced to 3.92 $\sqrt{t}$, which was 5% faster than 3.727 $\sqrt{t}$ assumed 60% water-cement ratio, R=1 in that of kishitani. After measuring chloride concentration in concrete, it was concluded that about 24% of all readings on samples from concrete exceed the critical content to minimize the risk of chloride-induced corrosion. About 31% of the freeway viaducts structures had a value lower than -350mV(vs. CSE), so it could conclude that the excessive chloride concentration was the major cause of reinforcement corrosion. Among the structures which measured half-cell potentials less than -350mV, about 50% exceeds the maximum acceptable limit of chloride concentration.

Probabilistic Estimation of Service Life of Box Culvert for Power Transmission Considering Carbonation and Crack Effect (탄산화와 균열을 고려한 전력구 콘크리트 구조물의 확률론적 수명 예측)

  • Woo, Sang-Kyun;Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.30-40
    • /
    • 2014
  • The demand of underground structure such as box culvert for electric power transmission is increasing more and more, and the service life extension of these structures is very important. Recent observations in field and experimental evidences show that even steel in concrete can be corroded by carbonation reaction of cover concrete. Carbonation-induced corrosion in concrete may often occur in a high carbon dioxide environment. In this study, the risk of carbonation of box culverts in our nation was evaluated by measuring the carbonation rate and concrete cover depth in field. Then, the service life due to carbonation at the cover depth was calculated by in situ information and the Monte Carlo simulation in a probabilistic way. Additionally, the accelerated carbonation test for the cracked beam specimen was executed and the crack effect owing to the carbonation process on the service life of box culvert was numerically investigated via Monte Carlo simulation based on the experimental results.

접촉쌍성 AA UMa의 재검토

  • Song, Mi-Hwa;Kim, Cheon-Hwi;U, Su-Wan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.146.2-146.2
    • /
    • 2012
  • 2008년부터 2012년에 걸친 관측기간 동안 총 21일간 관측하여 AA UMa의 BVRI 광도 곡선을 획득하였다. AA UMa의 I 필터 광도 곡선은 이번에 처음으로 얻어진 것이다. 또한 극심시각을 추가적으로 획득하기 위하여 2005 ~ 2008년까지 총 8일간 AA UMa의 극심 부근의 측광관측을 수행하였고, SuperWASP에서 공개하는 AA UMa의 측광 자료를 수집하여 총 31개의 새로운 극심시각을 결정하였다. 우리의 새로운 극심시각을 포함하여 83년 동안의 AA UMa 극심시각을 수집하여 총 250개의 극심시각으로 주기 변화연구를 수행하였다. 그 결과 AA UMa 계는 $3.30{\times}10^{-11}d/yr$의 영년 주기 증가 위에 58.7년의 주기적인 변화가 겹쳐 발생한다. 주기적인 변화의 원인이 제3천체에 의해 발생한다고 가정했을 때 제3천체의 최소 질량은 $0.28M_{\odot}$이다. 이전 연구자의 광도곡선(Meinunger(1976), Wang et al.(1988), Lee et al(2011))을 수집하여 우리의 광도곡선(2008, 2012)과 함께 각각 주기변화가 보정된 통일된 기산점을 사용하여 광도곡선을 분석하였다. 모든 광도곡선에서 0.75 위상에서 밝기가 더 어두워지는 O'Connell effect가 발생하였고, 일부 광도곡선은 부식에서 식의 깊이가 주식보다 깊어지는 시기를 가진다. 이는 스펙트럼 유형이 F0-F5보다 만기형 별에서 흑점이 부식의 깊이에 영향을 주어 주식보다 깊어지는 AC Boo, TY UMa 등에서 보여 지는 특징이다. 우리는 WD 프로그램을 이용하여 광도곡선 중 B-V 색지수 그래프에서 식 이외부분에서 변화가 적고 광도곡선의 O'Connell effect의 크기가 작은 2008 광도곡선으로 광도해를 결정하였다. 전형적인 TY UMa형 별과 같이, 우리의 광도해 역시 W-subtype의 결과를 나타낸다. 결정된 광도해를 다른 광도곡선에도 적용시켜 광도곡선에 나타나는 흑점의 영향을 살펴보았다. 마지막으로 주기 분석 결과와는 달리 제 3천체의 광도는 검출 되지 않았다.

  • PDF

An Experimental Study on the Fundamental Properties and Durability of Sewer Type Restorative Mortar Spread with Antibiotics (항균제를 도포한 하수시설용 단면복구 모르타르의 기초물성 및 내구특성에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Kim, Jae-Hwan;Cho, Bong-Suk;Lee, Dong-Heck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 2006
  • Deterioration of sewer concrete is representative that biochemical corrosion according to the $H_2S$ has growth by inhabit sulfur-oxidzing bacteria because of special environment in sewer. But in case of domestic, fundamentally, sulfur-oxidzing bacteria could moderate development of repair material method is need because of corrosion prevent method is inconsideration with carry out to improve project. In this paper, after development of spread type antibiotic with antibio-metal, antibacterial performance about sulfur-oxidzing bacteria of antibiotic and tested to estimate fundamental properties of bonding strength, abrasion contents, contents of water absorption, contents of air permeability, carbonation depth, chloride ion penetration depth and chemical resistance of spread with antibiotic restorative mortar.

Effect of Ear and Near-side Single Circular Pit Depth and Bulk Stress on Magnetic Flux Leakage at ferromagnetic Pipeline (강자성 배관 외.내부 면의 단일 원형 홈의 깊이와 부피응력이 누설자속에 미치는 영향)

  • Ryu, Kwon-Sang;Park, Young-Tae;Atherton, D.L.;Clapham, L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.263-269
    • /
    • 2003
  • Magnetic flux leakage (MFL) signals were used for corrosion inspection of buried oil and gas pipeline. 3D finite element analysis was used to examine the effects of far and near-side pit depth and tensile stress on MFL signals. Anisotropci materials were used, and the effects of simulated tensile stress on MFL were investigated. The axial and radial MFL signals depended on far and near-side single pit depth and on the bulk stress, but the circumferential MFL signal did not depend on them. The axial and radial MFL signals increased with increasing pit depth and the bulk stress, but the circumferential MFL signal was scarcely changed.