Browse > Article
http://dx.doi.org/10.11112/jksmi.2013.17.5.031

An Performance Evaluation of the Post-installed Anchor System According to the Freezing and Thawing of Concrete and the Corrosion of Anchor  

Kwon, Min-Ho (경상대학교 토목공학과 공학연구원)
Kim, Jin-Sup (경상대학교 토목공학과)
Jung, Woo-Young (강릉원주대학교 토목공학과)
Kwon, Sang-Won (경상대학교 토목공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.17, no.5, 2013 , pp. 31-39 More about this Journal
Abstract
In this study, performance of the post-installed anchor system was evaluated with reduced strength of concrete and anchor. One of the post-installed anchors was selected to performance evaluation. Concrete strength was reduced by freeze-thawing test, and the post-installed anchor strength was reduced by corrosion test. The post-installed Anchor was installed in concrete of freezing and thawing and original concrete, and corroded anchor was installed in original concrete only. Anchor diameter and installation depth of the anchor were the variable for each specimen. Performance of post-installed anchor system of each specimen was evaluated by pullout test. Anchor diameter and installation depth of anchor, it may affect the performance of the post-installed anchor system from the experimental test results. Fracture mode of each post-installed anchor system had occurred differently depending on the durability of concrete and anchor. The anchor pullout strength from the experimental test results was used in order to compare with the results of CCD (Concrete Capacity Design) method, and CCD equation was modified. Modified equation was able to predict the anchor pullout strength of post-installed anchor system in Original concrete and freezing and thawing of concrete.
Keywords
Post-installed anchor; Freeze-thawing test; Corrosion; Pull-out test; Concrete; Set anchor; CCD method;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 ACI Committee 349, "Code Requirements for Nuclear Safety Related Concrete Structures (ACI 349-90)", American Concrete Institute, Detroit.
2 Chung, L., Won, J. H., Cho, S. H., "Structural Performance of Reinforced Concrete Columns due to Corroded Main and Hoop Bars", Architectural Institute of Korea, Vol. 20, No. 3, 2004, pp.3-10 (in Korean).   과학기술학회마을
3 Hwang, H. J., Park, D. C., Oh, S. G., "Durability Life Prediction of Concrete Subjected to Freezing-Thawing and Chloride Attack", The Korea Institute of Building Construction, Vol. 8, No. 2, 2008, pp.97-101 (in Korean).   DOI   ScienceOn
4 Kim, H. U., Jee, N. Y., "Effect of the Rebar Corrosion Rate on Bond Strength in Reinforced Concrete - factors caused by compressive strength and embedded rebar condition", Architectural Institute of Korea, Vol. 21, No. 11, 2005, pp.159-166 (in Korean).   과학기술학회마을
5 Kim, J. S., Kwon, M. H., Seo, H. S., Park, J. H., "Performance Evaluation and Analysis Model for the Post-Installed Anchor", Journal of KOSHAM, Vol. 13, No. 2, Apr. 2013, pp.089-095 (in Korean).   과학기술학회마을   DOI   ScienceOn
6 Kim, S. Y., Seo, S. Y., Kim, K. S., "Tensile Strength of Expansion Anchors installed in Uncracked and Unreinforced Concrete", Architectural Institute of Korea, Vol. 19, No. 11, 2003, pp.83-92 (in Korean).   과학기술학회마을
7 Kim, Y. H., You, S. G., "Evaluation and Application of Pullout Strength of Single Anchor in Plain Concrete According to Edge Distance", Journal of the Korea Institute for Structural Maintenance Inspection, Vol. 8, No. 1, 2004, pp.211-220 (in Korean).
8 Summary of the KCI code, the Korea Concrete Institute, 2012.
9 Oh, S. G., "The Change of Chloride Attack Resistibility of Concrete Damaged Due to Freezing-Thawing", Architectural Institute of Korea, Vol. 25, No. 4, 2009, pp.169-176.   과학기술학회마을
10 Seo, S. Y., Yoon, S. J., Kim, S. S., Yoon, Y. D., "An Experimental Study on the Pull-out Strength of Post-Installed Anchor Bolt", The Regional Association of Architectural Institute of Korea, Vol. 2, No. 1, 2006, pp.359-362 (in Korean).