• Title/Summary/Keyword: 부분 고정도

Search Result 932, Processing Time 0.025 seconds

Noise Elimination Algorithm for Detecting Partial Discharge of Generator Stator Winding Considering Relation of Periphery Signals (고압 회전기 고정자 권선의 부분방전 계측 시 주변 신호 관계를 고려한 노이즈 제거기법)

  • Shin, Hee-Sang;Cho, Sung-Min;Kang, Chul;Kang, Dong-Sik;Cho, Kuk-Hee;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.17-24
    • /
    • 2008
  • Recently, the importance of supplying the reliable electric power is increasing. therefore, the importance of diagnosis of power equipments is increasing also. Breaking insulation of stator windings is major cause of faults in high voltage generators. On-line PD (Partial Discharge) detection using Capacitive Coupler at stator windings is used widely to diagnose high voltage generator. However, precise PD(Partial Discharge) detection is impossible if detected signals are mixed with PD and noise signal. In this paper, we analyze detected signals using Capacitive Coupler at 13[kV] hydroelectric generator stator winding and suggest not hardware method but noise elimination algorithm for detecting PD of generator stator winding considering relation of periphery signals.

다수의 부품으로 구성된 직렬형 시스템의 부분적 고정충격 수명검사에 관한 최적계획

  • 박희창
    • Communications for Statistical Applications and Methods
    • /
    • v.2 no.2
    • /
    • pp.395-403
    • /
    • 1995
  • 본 논문에서는 서로 독립인 다수의 부품으로 구성된 질렬형 시스템의 부분적 고정충격 수명검사에 관한 최적 검사계획에 관하여 고찰하였다. 시스템을 구성하고 있는 부품의 수명이 서로 독립인 지수분포를 따른는 것으로 가정하여 각 부품을 고장류과 가속인자의 최우추정량을 구하였다. 또한 각 부품의 고장률과 가속인자에 관한 최우추정량의 일반화 점근분산의 합과 각 부품의 가속인자에 관한 최우추정량의 점근 분산의 합을 구하여 이를 최소가 되게 하는 최적 표본할당비율을 구하였다.

  • PDF

삼천포 수역 죽방렴 어장의 구조와 유향유속

  • 강경미;전용호;신현옥;류청로;황보규
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.10a
    • /
    • pp.59-60
    • /
    • 2001
  • 함정그물은 어살류와 낙망류로 나뉜다. 그 중 죽방렴은 고정목을 설치하여 어획하는 어구로서 어살류에 속한다. 죽방렴은 유속이 매우 빠른 남해안 협수로에서 이루어지는 어업으로, 날개와 발통 두 부분으로 구성된 어구이다. 어구의 구조는 해저에 돌을 쌓아올려 그 위에 고정목을 박아 V자형 날개를 설치하고, V자의 꼭지점에 해당하는 곳에 발통을 설치한다. 과거에는 발통 부분을 대나무로 엮어서 만들었기 때문에 죽방렴이라 했으나, 현재는 대나무 대신 망목 크기가 작은 그물을 발통 내부에 둘러싼다. (중략)

  • PDF

Design of Partial Discharge Sensor using Transmission Line Theory in Rotating Machine (전송선로 이론을 이용한 회전기내 부분방전 검출 센서 해석 및 설계)

  • Heo, Chang-Geun;Kang, Dong-Sik;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.49-51
    • /
    • 2004
  • 고전압 기기의 절연물 내부에서 부분방전 현상이 발생되면 절연파괴로 진전된다. 회전기기가 운전중인 상태에서 on-line 부분방전시험은 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단으로서 이러한 부분방전시험을 통하여 회전기기 시스템의 사고예방을 위한 진단을 할 수 있다. 부분방전 펄스는 10MHz $\sim$ 1GHz의 대역폭을 갖는 것으로 알려져 있으며, 이러한 고주파 대역의 전자파 에너지의 효과적인 검출을 위한 센서 중 하나로 웨이브가이드 구조의 고주파 검출센서가 존재한다. 기존의 전자기적 에너지를 검출하는 SSC (Stator Slot Coupler)센서를 한쪽 포트를 가지는 마이크로스트립센서 형태로 사용할 경우 접지면이 도체전체로 씌워져 있고 임피던스 정합을 위한 50옴의 칩저항이 신호라인과 접지사이 루프를 형성하여 기기 운전시 기기의 성능에 영향을 미칠 수 있는 단점을 가지고 있다. 이 단점을 보완하기 위해서 본 논문에서는 회전기내 부분방전 펄스의 전자기적 에너지를 검출할 수 있는 2선 평행 전송선로 라인을 응용한 부분방전 검출 센서를 제안하였고 시뮬레이션을 통해 성능을 입증하였다. 제안된 센서의 성능을 입증하기 위하여 2선 평행 전송선로 타입의 센서와 기존의 SSC (Stator Slot Coupler) 센서를 약간 변형시킨 마이크로 스트립 센서를 고정자 슬롯의 Wedge 부착한 후 두 센서 비교 분석하였다. 결과적으로 제안된 센서는 기존 SSC 타입의 마이크로스트립 센서에 비하여 더 간단한 형상을 가지며 운전 중 기기의 성능에 영향을 덜 미치는 효과를 얻을 수 있었다.

  • PDF

Ultrastructural Study on the Ependymal Cells of the Read-Irradiated Rats (방사선이 뇌실막세포의 미세구조에 미치는 영향)

  • Ahn, E-Tay;Cho, Hwee-Dong;Kim, Jin-Gook;Park, Kyung-Ho;Ko, Jeong-Sik
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.11-23
    • /
    • 1999
  • Ultrastructure of the ependymal cells of X-irradiated rats on their head were studied. Rats weighing $200\sim250gm$ were X-irradiated on their head and neck areas. Total exposures were 3,000 rads or 6,000 rads depending on experimental groups. And irradiated rats were sacrificed on 6 hours, 2 days and 6 days following the radiation exposures. Animals were perfused through the heart with 1% glutaraldehyde-1% paraformaldehyde solution, under ether-anesthesia. The tissues from the wall of lateral ventricles were fixed in the 2% osmium tetroxide solution. The results observed with electron microscope were as follow: 1. In 6 hours group, many ependymal cells were swelled, luminal portions of cytoplasms of some cells protruded into the ventricular lumen, and many cilia were lost or irregularly altered. 2. In 2 days group, ependymal cells were swelled more severely and subependymal edema were pronounced. 3. Protruded cytoplasm contained usually basal bodies of cilia, groups of mitochondria, endoplasmic reticula , etc. 4. Following X-irradiations, some protruded masses contained neural elements including the axon terminals with dense core vesicles. Axons and axon terminals were also found in the enlarged intercellular spaces among ependymal cells. From the above results, the heavy irradiation on the head area of the rat induced alteration of the ependymal cells lining the lateral ventricle. Hence the ependymal functions of selective barrier, protective barrier, and metabolic barrier could be altered following X-irradiation on the head.

  • PDF

Friction Characteristics on Interface Between Reinforcement and Sand by Direct Shear Test Methods (전단시험방법에 따른 토목섬유/모래 접촉면에서의 마찰특성)

  • Ju, Jae-Woo;Park, Jong-Beom;Chang, Yong-Chai
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 2003
  • The most important part in the earth reinforcement is the interface between soil and the reinforcement. Shear strength and shear behavior in this interface make a great role relating to the reinforcement effect. This paper presents 2 kinds of direct shear test methods. one is the strain free shear test, called 'free method', that is performed by the free condition of allowing tensile strain. The other is the strain fix shear test, called 'fixed method', that is performed by the fixed condition of not allowing tensile strain. Two reinforcements were used such as nonwoven geotextile and geogrid. That is, interfaces are composed of geogrid/sand and geotextile/sand. From the test results it shows us that the fixed method had a greater friction angle and a smaller peak shear strain than those of the free method. Residual stress of the fixed method was bigger than that of the free method but the residual stress ratio was vice versa.

  • PDF

블록화된 $2^{n-k}$ 부분실시법의 최적 디자인 선택에 관한 연구

  • 김공순;배종성
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.2
    • /
    • pp.393-401
    • /
    • 1997
  • 블록화한 $2^{n-k}$부분실시법에서 총 실헙횟수를 32회로 고정할때, 요인수가 ${6\leqq}n{\leqq10}$인 경우 가능한 모든 요인들간의 조합에 대해서 독립 생성자와 블록생성자를 구하고 이들 각 요인과 블록생성자로 구성된 디자인의 단어길이구조를 구하였다. 그리고 최소길이 방법으로 구한 최적의 부분실디자인을 Soren(1994a)의 방법에 따라 블록화하였다. Brownlee등(1948)의 최소길이 성질을 블록화한 부분실디자인에 확장시키고, 블록화한 부분실디자인은 확장된 최소길이 성질을 만족하는 최적의 디자인임을 보였다.

  • PDF

Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report (하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고)

  • Kee, Wonjin;Park, Jae-Ho;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.176-181
    • /
    • 2019
  • Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may be lowered due to patient's discomfort and damage of the abutment. Recently, it has been reported that the unilateral posterior extension partial denture is used as a bilateral posterior extension partial denture using implant fixed prostheses as abutments. In this case, by using implant surveyed crown prostheses, bilateral posterior extension partial denture is fabricated in site that is predicted to have a poor prognosis. This resulted in improved support, maintenance, and stabilization of the removable partial denture, which were economically beneficial to patient and satisfied with use.

가동보의 홍수재해 절감효과에 관한 연구

  • Kim, Phil-Shik;Kim, Sun-Joo;Shim, Jae-Hoon;Park, Hyun-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.808-812
    • /
    • 2010
  • 본 연구에서는 경상남도 마산시의 광려천을 대상으로 미공병단의 HEC-RAS 모형을 선정하여기 설치된 고정보가 있는 하천(ScenarioI), 가동보가 있는 하천(ScenarioII), 시간이 흘러 토사 퇴적이 이루어진 상태의 고정보(ScenarioIII)가 있는 하천 일 때 3개의 하천 단면을 설계하여 하천흐름에 미치는 영향을 분석하고 가동보로 개량시 홍수재해 절감 효과를 분석하였다. 홍수량에 따른 수위분석 결과 ScenarioI, ScenarioIII에서는 수위가 상승하여 여유고 기준을 초과하는 부분이 나타나며, 가동보를 도복했을 경우인 ScenarioII에서는 여유고 기준을 초과하는 부분 없어 가동보의 도복 효과로 홍수시 고정보보다 홍수재해 절감 효과가 있는 것으로 나타났다.

  • PDF

인공구조물의 밀도분포 파악을 위한 고정밀중력탐사

  • Im, Hyeong-Rae;Park, Yeong-Su;Im, Mu-Taek;Gu, Seong-Bon;Gwon, Byeong-Du;O, Seok-Hun
    • 한국지구과학회:학술대회논문집
    • /
    • 2005.02a
    • /
    • pp.147-152
    • /
    • 2005
  • 인공구조물인 댐체의 밀도 분포를 밝히기 위하여 사력댐에서 고정밀중력탐사를 수행하였다. 얻어지는 중력이상값이 매우 작은 양이므로 정밀한 지형보정을 위하여 삼각요소법을 도입하였다. 역산을 위해서도 댐체의 모양을 그대로 반영할 수 있도록 임의 다면체로 구성하였고, 글로벌 역산인 ASA를 이용하여 해석하였다. 해석결과는 댐의 코어 부분과 모래와 암석으로 채워진 부분이 명확히 구분되었고, 댐의 중앙부에 상대적인 저밀도가 존재하는 수평적인 밀도 변화도 확인할 수 있었다.

  • PDF