• Title/Summary/Keyword: 부분 고정도

Search Result 932, Processing Time 0.028 seconds

A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge (고정형쐐기(Physical Wedge)와 동적쐐기(Dynamic Wedge)의 조사야 주변 선량에 관한 연구)

  • Min, Je-Soon;Na, Kyung-Soo;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.77-82
    • /
    • 2007
  • Purpose: This study investigates peripheral dose from physical wedge and dynamic wedge system on a multileaf collimator (MLC) equipment linear accelerator. Materials and Methods: Measurments were performed using a 2D array ion chamber and solid water phantom for a 10$\times$10 cm, source-surface distance (SSD) 90 cm, 6 and 15 MV photon beam at depths of 0.5 cm, 5 cm through dmax. Measurments of peripheral dose at 0.5 cm and 5 cm depths were performed from 1 cm to 5 cm outside of fields for the dynamic wedge and physical wedge 15$^\circ$, 45$^\circ$. Dose profiles normalized to dose at the maximum depth. Results: At 6 MV photon beam, the average peripheral dose of dynamic wedge were lower by 1.4% and 0.1%. At 15 MV photon beam, the peripheral dose of dynamic wedge were lower by maximum 1.6%. Conclusion: This study showed that dynamic wedge can reduce scattered dose of clinical organ close to the field edge and reduced treatment time. The wedge systems produce significantly different peripheral dose that should be considered in properly choosing a wedge system for clinical use.

  • PDF

Pattern of partial discharge for stator windings fault of high voltage motor (고압전동기 고정자권선 결함 부분방전패턴)

  • Park, Jae-Jun;Kim Hee-Dong
    • The Journal of Information Technology
    • /
    • v.7 no.1
    • /
    • pp.155-161
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[kV] and 6.67[kV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box. Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

Fixed-point Error Optimization of AC-3 Decoding Algorithm (AC-3 복호화 알고리듬의 고정 소수점 오차 최적화)

  • 이근섭
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.08a
    • /
    • pp.438-441
    • /
    • 1998
  • 최근 미국 내 표준안으로서 많이 사용되고 있는 AC-3 오디오 알고리듬은 그 복잡성으로 인하여 실시간 구현을 위해선 프로세서로 구현하는 것이 적합하다. AC-3 복호화 알고리듬은 많은 부분이 실수연산으로 이루어져 있으므로 소수점을 고려한 연산이 필요한데, 프로세서로 구현할 때는 적은 비용과 빠른 속도로 실수연산을 수행하기 위해서 부동소수점보다는 고정소수점 연산이 유리하다. 그러나 고정소수점 연산시 발생하는 유한 단어길이 효과로 인하여 양자화 오차가 발생하므로 복호화된 오디오 신호의 음질저하를 최소화하기 위해서는 최적화가 필요하다. 본 논문에서는 AC-3 복호화 알고리듬의 부분별 양자화 오차를 분석하고 그 결과 가장 많은 오차를 발생시키는 역 TDAC 변환의 오차를 최적화하였다. Fast TDAC 변환이 FFT로 이루어져 있으므로 고정 소수점 연산시 오차가 적은 FFT 구조를 제안하였다. 제안된 구조를 사용하여 AC-3 고정소수점 복호화기를 C 언어를 사용하여 구현하였으며, AC-3 부동소수점 복호화기와 최종 PCM을 비교하여 그 성능을 평가하였다.

  • PDF

Microstrip Line Sensor of Partial Discharge for Rotating Machine (회전기내 부분방전 검출을 위한 마이크로스트립 라인 센서)

  • Chae Soo-Jeong;Kim Yong-Joo;Kang No-Weon;Kang Dong-Sik;Jung Hyun-Kyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.81-84
    • /
    • 2003
  • 부분방전시험은 고전압 고정자 권선의 절연상태를 검사, 평가 할 수 있는 중요한 수단이다. 전동기와 발전기에서 일어나는 절연 악화의 징후로써 부분방전이 발생되며 이러한 부분방전 신호를 검출하기 위한 센서로 SSC(Stator Slot Couple)를 사용한다. 하지만 현재 사용되고 있는 대부분의 SSC의 경우 설계에 있어 특성 임피던스가 실제구조에서 정확히 고려되지 않는 경향이 있다. 실제로 고정자 슬롯에 부착된 마이크로스트립 센서의 특성 임피던스는 정확히 50옴으로 정합 되지 않으며 이것은 센서의 성능에 중요한 영향을 미치게 된다. 그러므로 본 논문에서는 부분방전 센서의 성능을 개선시키기 위해 결합 전송선로(Coupled transmission line)를 이용한 임피던스 정합회로를 제안하고자 한다. 제안된 센서의 성능을 입증하기 위하여 고정자 슬롯에 설치된 기존의 SSC와 임피던스 정합회로를 부착한 센서를 시뮬레이션 한 후 비교 분석하였다. 결과적으로 제안된 정합 회로는 광대역 임피던스 정합 특성을 가지며 임피던스 부정합때문에 일어나는 기존 SSC의 성능 악화를 개선할 수 있었다.

  • PDF

A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge (고정형 쐐기(Physical wedge)와 동적 쐐기(Dynamic wedge)의 조사야 주변 선량에 관한 연구)

  • Ko, Shin-Gwan;Min, Je-Soon;Na, Kyung-Soo;Lee, Je-Hee;Park, Heung-Deuk;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.407-413
    • /
    • 2008
  • Measurements of the peripheral dose were performed using a 2D array ion chamber and solid water phantom for a $10{\times}10cm$, source-surface distance (SSD) 90cm, 6 and 15MV photon beam at depths of 0.5cm, 5cm through $d_{max}$. Measurements of peripheral dose at 0.5cm and 5cm depths were performed from 1cm to 5cm outside of fields for the dynamic wedge and physical wedge $15^{\circ}$, $45^{\circ}$. For 6MV photon beam, the average peripheral dose of dynamic wedge were lower by 1.4% and 0.1% than that of physical wedge For 15MV photon beam, the peripheral dose of dynamic wedge were lower by maximum 1.6% that of physical wedge. The results showed that dynamic wedge can reduce scattered dose of clinical organ close to the field edge. The wedge systems produce different peripheral dose that should be considered in properly choosing a wedge system for clinical use.

  • PDF

Assessment of Insulation Condition in 13.8 kV Generator Stator Windings (13.8 kV급 발전기 고정자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1624-1625
    • /
    • 2011
  • 35년 이상 동안 운전된 2대의 가스터빈 발전기(70 MVA, 13.8 kV) 고정자 권선의 절연상태를 평가하기 위해 정지중 절연진단 시험을 수행하였다. 성극지수, 교류전류, 유전정접 및 부분방전 크기 등을 측정한 결과 모두 양호하여 절연상태가 매우 건전하게 평가되었다. 유전정접이 서서히 증가하는 전압이 부분방전 개시전압과 거의 일치하며, 이 전압은 다시 제1차 전류 급증점 보다는 3 kV정도 낮게 분석되었다. 그리고 발전기 고정자 권선의 부분방전 패턴은 내부방전으로 분석되었다.

  • PDF

Area-Efficient Squarer and Fixed-Width Squarer Design (저면적 제곱기 및 고정길이 제곱기의 설계)

  • Cho, Kyung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.3
    • /
    • pp.42-47
    • /
    • 2011
  • The partial product matrix (PPM) of a parallel squarer is symmetric. To reduce the depth of PPM, it can be folded, shifted and rearranged. In this paper, we present an area-efficient squarer design method using new partial product rearrangement. Also, a fixed-width squarer design method of the proposed squarer is presented. By simulations, it is shown that the proposed squarers lead to up to 17% reduction in area, 10% reduction in propagation delay and 10% reduction in power consumption compared with previous squarers. By using the proposed fixed-width squarers, the area, propagation delay and power consumption can be further reduced up to 30%, 16% and 28%, respectively.

Effective Length Factors for Continuous Compression Members (연속 압축재의 유효길이 계수)

  • Choi, An-Ki;Song, Sang-Yong;Lee, Soo-Gon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.219-226
    • /
    • 2003
  • 보 유사법을 이용하여 연속 압축재의 유효길이 계수를 각 경간별로 결정하는 방법을 제안한다. 제안하는 보 유사법은 4가지 단계로 요약할수 있는데 그 첫 단계는 주어진 압축재를 이것과 동일한 단면성능 및 경간을 갖는 연속보로 치환하는 것이다. 제 2단계에서는 연속보 각 경간의 중앙에 가상 집중 횡하중을 작용시킨 후 이로 인한 지점들에서의 재단 moment를 계산한다. 이때 각 경간중앙의 가상 집중 횡하중 방향은 좌굴 mode를 고려하여 교호로 바뀌도록 한다. 제 3단계에서는 또 하나의 제안식과 재단 모멘트를 이용하여 Kinney의 부분 고정도를 결정한다. 최종단계에서는 부분 고정도를 이용하여 유효길이를 각 경간별로 산정 한다. 제안한 방법은 다 경간 압축재에서 어느 경간이 맨 먼저 좌굴을 일으키는지 또한 이때의 임계하중은 어떤 값을 갖는지를 예측하게 한다.

  • PDF

Insulation Characteristic of Stator Winding for Large Capacity Hydorgenerator (대용량 수력발전기 고정자권선의 절연특성고찰)

  • Oh, Bong-Keun;Lee, Kwang-Ho;Kim, Hyun-Il;Byun, Doo-Gyoon;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2042-2043
    • /
    • 2008
  • 수력발전기의 운전중 신뢰성 및 장기 사용된 발전기의 경우 노후도 평가를 위한 지표로 고정자권선의 물리적 절연상태를 평가하는 방법이 일반적으로 이용되고 있다. 시험방법은 크게 부분방전 특성을 검출하는 운전중(On-line) 진단기법과 정지중(Off-line) 진단기법이 있다. 운전중 진단기법은 발전기의 정지없이 상시 상태를 감시할 수 있는 장점이 있으므로 활용도가 증가되고 있고 정지중 진단기법은 고정자권선 절연상태를 정밀하게 평가할 수 있는 잘 알려진 시험법으로 권선의 절연상태를 모니터링하여 운영자에게 고장징후를 알려주고, 예측보전이 가능하도록 도움을 주고 있다. 이 논문에서는 장기간 운영된 대용량 수력발전기의 정지중 절연진단기법(성극지수, 교류전류, 유전정접, 부분방전) 결과의 통계적 추이변화 고찰을 통하여 대용량 수력발전기 고정자 권선의 신뢰성평가를 실시하였다.

  • PDF

Measurement of compressive and tensile strain in concrete structure with FBG sensor fixture (광섬유격자센서의 콘크리트구조물에의 고정과 압축 및 인장 변형의 측정)

  • Kim, Ki-Soo;Kim, Young-Jin;Moon, Dae-Jung;Kim, Seong-Woon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.149-152
    • /
    • 2008
  • FBG sensor system is applied to the concrete lining structure in Taegu subway. Near the structure, the power cable tunnel construction started. We wanted to measure the deformation of the structure due to the construction by the FBG sensor. The applied sensor has the gauge length of 1 meter to overcome the inhomogeneity of the concrete material with enough length. In order to fix tightly to the structure, the partially stripped parts of the sensor glued to the package and slip phenomenon between fiber and acrylate jacket was prevented. Prestrain of the sensor was imposed by controlling the two fixed points with bolts and nuts in order to measure compressive strain as well as tensile strain. The behavior of subway lining structure could be monitored very well

  • PDF