• Title/Summary/Keyword: 부력식

Search Result 91, Processing Time 0.032 seconds

Flame Length Characteristic for Varying Nozzle Diameter to Develop Oxy-Fuel Combustor (순 산소 연소기 개발을 위한 노즐직경변화에 따른 화염길이 특성)

  • Kim Ho-Keun;Kim Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.861-867
    • /
    • 2005
  • In order to develop oxy-fuel combustor, the Flame length characteristic of $CH_4$ with oxidizer of air and oxygen has been experimentally investigated for tile nozzle diameters of 1.6mm, 2.7mm, 4.4mm and 7.7mm. The structure of $CH_4$ flame with oxidizer of oxygen was sharp in contrast with the $CH_4$ flame with oxidizer of air. The stability of $CH_4$ flame with oxidizer of oxygen was higher than $CH_4$ flame with oxidizer of air. In all $CH_4$ flames with oxidizer of air and oxygen, the flame length were dependent on the flowrate in laminar flame regime, and in turbulent flame dependent on the initial jet diameter. Using correlation equation of Delichatsios, the flame length has been expected exactly for $CH_4$ flame with oxidizer of air, but underestimated for $CH_4$ flame with oxidizer of oxygen. This paper proposed correlation equation of $CH_4$ flame with oxidizer of oxygen.

A Study on the Integration Control System Development for Smoke Control (연기제어를 위한 통합제어시스템 개발에 관한 연구)

  • Lee, Dong-Myung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.15-20
    • /
    • 2006
  • This study developed integration control system that improve efficiency and give flexibility of smoke control system and can improve prevention of disasters performance. The reliable each kind sensor and of integration control system was developed by establishing the specifications, algorithms and constructing engineering data. More correct and reliable control function of optimization can be obtained by the central control from integration control system rather than the existent individual control. This sees to do to impose flexibility to smoke control system. Also, this will provide the basics of integration control system and ability security of smoke control system and can construct smoke control system of performance based.

Study on the Improvement of Stow Net Fishing Technigue and the Enlargement of Fishing Groung to the Distant Waters 2 . Model Experiment on the Newly Designed Gear (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 2 . 새로 설계된 어구의 모형실험 -)

  • Lee, Byeong-Gi;Kim, Jin-Geon;Lee, Ju-Hui
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.1
    • /
    • pp.6-11
    • /
    • 1989
  • Some distinctive defects in the conventional stow net were examined and presented in the previous report of this series. To find out the more effective gear by correcting the defects, the authors carried out another experiment by using a newly designed gear. 1. Special features of the newly designed gear are: (1) stretched width of front end on top, bottom and side panel are decreased 20%, on the other hand, the frank of the panels are increased 10% compared with the conventional gear. Front end of top and bottom panels are bias cutten up to 20% of the length of panels. (2) Length of the head rope and ground rope are shortened 6% by changing of the shape of the top and bottom panels. (3) Lacing lines are attached to four longitudinal seaming lines with suitable hanging ratio. (4) Stretched height of the shearing device were shortened 17%, and the buoyancy on top of the device were increased 20%. (5) Length of the biforked pendants were arranged to be shorter on top-most and bottom-most ones, and loner on middle ones. 2. The observed result can be expressed as (1) Wrinkles in the front end of top panels are removed and fringe line of panels become smooth. (2) Opening height of mouth is observed 3% higher than that of the conventional gear. (3) Opening width is 1.5 to 1.6 times wider than that of the conventional gear. (4) Hydrodynamic resistance is decreased 10%-17%.

  • PDF

Parametric Study on Effect of Floating Breakwater for Offshore Photovoltaic System in Waves (해상태양광 구조물용 부유식 방파제의 파랑저감성능 평가)

  • Kim, Hyun-Sung;Kim, Byoung Wan;Lee, Kangsu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2022
  • There has been an increasing number of studies on photovoltaic energy generation system in an offshore site with the largest energy generation efficiency, as increasing the researches and developments of renewable energies for use of offshore space and resources to replace existing fossil fuels and resolve environmental challenges. For installation and operation of floating photovoltaic systems in an offshore site with harsher environmental conditions, a stiffness of structural members comprising the total system must be reinforced to inland water spaces as dams, reservoirs etc., which have relatively weak condition. However, there are various limitations for the reinforcement of structural stiffness of the system, including producible size, total mass of the system, economic efficiency, etc. Thus, in this study, a floating breakwater is considered for reducing wave loads on the system and minimizing the reinforcement of the structural members. Wave reduction performances of floating breakwaters are evaluated, considering size and distance to the system. The wave loads on the system are evaluated using the higher-order boundary element method (HOBEM), considering the multi-body effect of buoys. Stresses on structural members are assessed by coupled analyses using the finite element method (FEM), considering the wave loads and hydrodynamic characteristics. As the maximum stresses on each of the cases are reviewed and compared, the effect of floating breakwater for floating photovoltaic system is checked, and it is confirmed that the size of breakwater has a significant effect on structural responses of the system.

Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field (해남 농경지에서의 자유 수면 증발 관측과 해석)

  • Han Jin-Su;Lee Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Class A evaporation pan has been used throughout the world to measure free water evaporation mainly by manual observation once a day. In this study, a new automatic water level measurement method is used for understanding of free water evaporation and numerical analysis. This new technique measures the weight of buoyancy bar in water, and does not need calibration because it is not affected by water density change with water temperature. Field observations of evaporation were made near Haenam Meteorological Station over paddy field located in southwestern Korea from 20 April to 30 May 2004 and the data from ten clear days (16 - 25 May) were used for this analysis. The observed total evaporation was about 50.7mm during this period whereas the estimated from an empirical equation was 50.4mm. As expected, the pan evaporation is well correlated with wind speed and the vapor pressure deficit between the water surface and the air.

Analytical Study on the Pullout Resistance Characteristics of Bored Pile (매입말뚝의 인발저항특성에 관한 연구)

  • Park, Jong-Bae;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.281-289
    • /
    • 2016
  • Structural experiment result showed that PHC(d=600mm) Pile used as a common compression member could resist 83.6 ~ 91.6 tonf of ultimate tension force, if the adhesion of P.C. bar of PHC pile to the concrete foundation is strengthened. Considering a proper safety factor to ultimate tension strength, PHC pile can substitute the anti-floating anchor, or reduce the number of anchors. For this purpose, pullout resistance behavior of a Bored pile embedded in real ground as well as structural tension strength of PHC pile must be evaluated. This study performed the static pullout tests to evaluate the pullout behavior of bored pile, and compared the test results with design value of side resistance. To evaluate the pullout resistance easily, static pullout test results were compared with dynamic loading test results using PDA. As a result, cement paste of the bored pile was hardened which is after 15 days, LH side resistance design value corresponded well to the Static pullout test results, also to the side resistance evaluated by dynamic loading test.

Experiment of Air Bubble Movement (Air Bubble 거동 특성 실험)

  • Kim, Seong Goo;Lee, Hyo Sang;Chang, Hyung Joon;Park, Ki Soon;Lee, Ho Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.512-512
    • /
    • 2017
  • 날로 심각해지는 해수 오염, 유류사고, 해파리에 의한 인명피해 및 발전소의 경제적 피해사고, 해양 쓰레기 등과 같은 해양 환경 문제가 발생하고 있다. 이러한 해양환경문제를 해결하기위해 생물학적 방법과 물리적 방법이 있으나 생물학적 방법은 개체군과 종류의 변화로 그 적용이 어려운 실정이고, 물리적 방법은 지속적인 제거를 위한 비용적인 문제와 인부 및 자원봉사자의 안전문제가 발생한다. 따라서 에어버블을 이용한 각종 친환경적 방법이 주목받고 있다. 본 연구에서는 에어버블 차단막의 차단율을 증가시키기 위해 현장조건 내에서 에어버블의 거동특성에 대한 실험을 하였다. 실험을 위해 회류식 개수로 에어버블 거동실험장치를 제작하였다. 실험장치는 길이 8.1m, 높이 1.2m, 폭 0.7m이며, 두께 10mm의 투명 아크릴를 사용하여 에어버블의 거동을 관찰 할 수 있게하였다. 대형펌프를 사용하여 물이 회류함을 통해 흐름유속을 만들어 현장조건을 고려하였다. 에어버블을 분사하기 위해 압축공기 저장탱크와 연결된 분사구가 있으며, 노즐의 크기(0.5mm~1.0mm)로 분사량을 조절하고 분사압은 별도의 조절장치를 이용하여 0~5bar 범위의 분사압 조절을 가능하게 하였다. 초고속 카메라와 3축유속계를 사용하여 에어버블의 이동경로, 유속 및 에어버블의 거동을 측정하였다. 실험을 통한 구간별 에어버블의 거동 분석 결과, 상승속도는 분사구에서 분출되는 구간인 0~0.8m 에서는 상승속도가 증가하고, 0.8~1.2m구간에서는 속도가 다시 상승하는 경향을 확인하였다. 이는 수표면에 가까워질수록 수압이 작아져서 에어버블의 크기가 커짐에 따라 부력이 커짐으로 판단된다. 같은 이유로 분사량이 많을수록 상승속도도 같이 증가되는 것으로 나타났다. 유속에 따른 거동은 유속을 0.1m/s~0.5m/s로 조정하여 유속별 에어버블이 수표면까지 도달하는 거리, 속도 및 이동경로를 분석하였다. 유속과 에어버블이 수표면까지 도달하는 거리는 비례하여 증가하는 것을 확인하였다. 실험결과를 바탕으로 조건에 따른 에어버블 거동 경험식을 도출하였다. 본 실험은 회류식 개수로 에어버블 거동실험장치를 활용하여 에어버블 거동 경험식을 제시하였으며, 이를 바탕으로 에어버블 차단막 기술 개발을 위한 기초자료로 이용될 수 있을 것이다.

  • PDF

Backflow Flow Analysis of Street Inlet drain using Fluent Model (빗물받이 연결관 역류 흐름 해석을 위한 Fluent 모형 적용)

  • Lee, Min Sung;Kim, Jung Soo;Yoo, In Gi;Yoo, Kyu Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.245-245
    • /
    • 2022
  • 최근 국내 기후변화에 따른 국지성 집중호우로 인한 시간당 강우량의 증가로 도로부 유출량의 증가와 배수관거에서의 내수배제 불량에 따른 도심지 내수침수 피해가 증가함에 따라 이를 해결하기 위한 우수유출저감시설이 설치되고 있다. 그러나 대단위의 지하 저류시설의 지속적인 설치는 과밀화된 도심지에서 설치 지하공간의 구조적인 한계 및 적정 설치 위치의 미확보 등의 다양한 문제가 발생하여 저류시설의 침수저감 효과에 대한 추가적이고 새로운 저류시설에 대한 연구가 필요한 실정이다. 이에 내수 침수 저감 및 배수 능력 향상을 위한 도로 배수시설과 연계된 도로 측구부 저류시스템 구축이 필요하다. 이를 위해 역류 방지 및 노면수 저류 빗물받이에 적용되는 부력식 역류차단장치를 개발하였으며, 역류차단장치의 최적 형상 개발을 위해서 기존 빗물받이 연결관과의 통수능 비교 및 분석이 필요한 실정이다. 따라서 본 연구에서는 기존 빗물받이 연결관 및 연결관 내에 역류차단장치가 적용된 역류차단 빗물받이의 흐름분석을 위해 Fluent 모형을 이용하여 3차원 수치모의를 수행하였다. 수치모의 구성으로는 전체 형상을 40×50cm의 빗물받이 유입부와 50×50cm의 빗물받이로 결정하고 격자는 빗물받이 내부의 복잡한 3차원 흐름을 모의하기 위해 1.2~2mm 크기로 생성하였다. 다상유동 해석을 위해 VOF(Volume of Fluid)방법을 적용하였고, 수치해석 방법으로는 비정상류, 난류 모형으로는 SST k-𝜔모형을 적용하였다. 해석조건으로는 김정수(2021) 등이 제시한 4차선 기준 설계빈도별(5~30년) 빗물받이 유입유량을 산정하여 빗물받이 유입조건으로 선정하였으며, 빗물받이와 연결관에서의 통수능력 분석 조건으로는 빗물받이에 기존 연결관이 부착된 조건과 연결관 내에 역류차단장치가 설치되어 역류차단장치가 개방된 조건에서의 통수능을 비교하였으며, 역류상황을 가정한 연결관에서의 통수능을 비교하기 위하여 역류차단장치의 개폐정도를 15도(통수단면 33%감소) 닫힌 상태 및 30도(통수단면 67% 감소) 닫힌 상태 조건을 대상으로 빗물받이와 연결관에서의 흐름을 모의하였다. 수치모의 결과 역류차단장치의 계폐조건에 상관없이 5년 빈도유입량 조건에서는 완전 배수가 되었으며, 개폐조건 15도에서는 10년 빈도의 유입량에서는 완전 배수가 되었으나 20년 빈도 이상의 유입량 조건에서 빗물받이 유입부로의 역류가 발생하였으며, 개폐조건 30도에서는 5년 빈도 이상 유입량 조건에서 빗물받이 유입부로 역류가 발생하는 것으로 나타났다. 특히, 30년 빈도 이상의 유입량부터는 빗물받이 연결관 내에 역류차단장치 개페조건과 관계없이 빗물받이 유입부로의 역류로 인한 도로 침수가 발생하기 때문에 유휴공간인 도로 측구부를 저류공간으로 활용할 수 있는 도로 측구부 저류시스템의 구축은 필수적이라고 판단되며, 유량 조건에 따른 빗물받이 내부 와 흐름과 유출부에서의 유속 변화 특성을 확인하였다. 그러므로 측구 저류조 개발 형상과 연결한 3차원 흐름의 구현 및 분석에 Fluent 모형의 적용이 가능하다고 판단된다.

  • PDF

Structural Performance Evaluation of Floating PV Power Generation Structure System (수상 부유식 태양광발전 구조물의 구조적 성능 평가)

  • Choi, Jin Woo;Seo, Su Hong;Joo, Hyung Joong;Yoon, Soon Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1353-1362
    • /
    • 2014
  • In recent years, numerous environmental problems associated with the excessive use of fossil fuel are taking place. For an alternative energy resource, the importance of renewable energy and the demands of facilities to generate renewable energy are continuously rising. To satisfy such demands, a large number of photovoltaic energy generation structures are constructed and planned with large scale. However, because these facility zones are mostly constructed on land, some troubles are occurred such as rising of construction cost due to the cost of land use, environmental devastation, etc. To solve such problems, the floating type photovoltaic energy generation system using FRP members have been developed in Korea. FRP members are recently available in civil engineering applications due to many advantages such as high strength, corrosion resistance, light weight, etc. and they are suitable to fabricate the floating structures because of their material properties. In this study, the analytical and experimental investigations to evaluate the structural performance of floating PV generation structure and SMC FRP vertical member which is used to fabricate the structure were conducted. The static and dynamic performances of floating PV generation structure are evaluated through the FE analysis and the experiment, respectively. Moreover, the structural safety evaluation and buckling analysis of SMC FRP vertical compression member are also conducted by the FE analysis, and the structural behavior of SMC FRP member under compression and pullout is investigated by the experiments. From this study, it was found that the structural system composed of pultruded FRP and SMC FRP members are safe enough to resist externally applied loads.

Effects of Double-diffusive Convection on the Mass Transport of Copper Ions in a Horizontal Porous Layer (수평 다공성유체층에서 이온의 물질전달에 대한 이중확산대류 효과)

  • Yoon Do-Young;Kim Min Chan;Choi Chang Kyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.98-105
    • /
    • 1999
  • In the present study, buoyant force and its stabilizing effects in an electrostatic field were examined systematically in order to reduce the effect of natural convection with thermal stratification in a horizontal fluid-saturated porous layer. The correlation of ionic mass transport induced by double-diffusive convection in a horizontal porous layer has been derived theoretically. And the theoretical model was examined by electrochemical experiments. The theoretical correlation for mass transport which is satisfying Forchheimer's flow equation and based on the micro-turbulence model is derived as a function of soltual Darcy-Rayleigh number, thermal Darcy-Rayleigh number and Lewis number. In the experiment, the mass transport of copper ions in $CuSO_4-H_2SO_4$ solution is measured by electrochemical technique. By assembling theoretical correlation and experimental results, the mass transport correlation induced by double-diffusive convection is proposed as $$Sh=\frac{0.03054(Rs_D-LeRa_D)^{1/2}}{1-3.8788(Rs_D-LeRa_D)^{-1/10}}$$ The present correlation looks flirty reasonable with comparing experimental results, and very promising for the applications of its prototype into various systems involving heat transfer as well as mass transfer, in order to control the effects of natural convection effectively.