• Title/Summary/Keyword: 봉합

Search Result 1,076, Processing Time 0.025 seconds

Postoperative Evaluation of Congenital Atrial Septal Defect in Adult (성인 심방중격결손증의 술후평가)

  • Kim, Ae-Jung;Jo, Jung-Gu;Gu, Ja-Hong;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.386-392
    • /
    • 1996
  • Preoperative and postoperative evaluation was done in 60 adult patients above 20 years of age among 152 patients, who had operation for the congenital atrial septal defect from January 1984 to June 1993 in the Department of Thoracic and Cardiovascular Surgery, Chonbuk National University Hospital. Anatomically, the secundum type defect was present In 58 cases and the other two were ostium primum type defect. The defect were closed directly in 45 cases and with patches in 15 cases. Preopera ive EKG findings revealed regular sinus rhythm in 81%, arrhythmia 19%, RVH 32%, RAD 30%, Postoperative findings were regular sinus rhythm in 76%, arrhythmia 24%, RVH 25%. RAD 25%. In hemodynamic data, the mean SPAP in patients over 40 years old was 41.91 $\pm$ 14.33mmHg compared to 31.46 $\pm$ 13.77 mmHg in patients under 40 years old, and the difference between the two groups was stastistically significant. And then the patients were classified into two groups (group A sinus group, and group B : arrhythmia group) according to their preoperative rhythm. The patients in group B were older, had greater value of mean SPAP and Rp/Rs. Mean Qp/qs was higher in group A. But the difference between two groups about the mean Qp/qs and Rp/Rs was not significant. Postoperative complications such as arrhythmia, pneumothorax or hemothorax occurred in 7 cases, but there was no operative mortality. The functional improvement were remarkable in half of the patients who underwent surgery.

  • PDF

Coronary Artery Bypass Surgery with Radial Artery -Early Results (요골동맥을 이용한 관상동맥우회술 -조기성적)

  • 나찬영;이영탁;박국양;이해영;김욱성;박?현;홍민수;심재천;권오춘
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.275-281
    • /
    • 1997
  • The radial artery as a graft for myocardial revascularization was introduced by Carpentier in the early 1970s. Mid-term results were unfortunately discoura ing, and the clinical experience with this graft was interrupted. At the end of the 1980s, these authors reproposed the same arterial conduit with more satisfying results, because of improved technique and pharmacological management of the graft. Between October 1994 and July 1995, 36 patients underwent myocardial revascularization with a radial artery graft in Seiong General Hospital. Left internal mammary artery was concomitantly used as a pedicled Vift in 34 patients. Fifteen patients (42%) had a complete arterial waft revascularization. A total of 12) distal anastomoses were performed (average 3.4 per patient), including 36 left internal mammary artery wafts (two sequential in 2 patients), and 23 saphenous vein grafts. The remaining 64 distal anastomoses were perFormed with radial artery grafts (mean 1.8 per patient). The radial arteries were anastomosed to the circumflex (n=38), diagonal (n= 18), right coronary(n=G), and left anterior descending coronary artery(n=2). The percent ge of radial artery graft anastomoses (64) to the total anastomoses(123) was 52%. The radial artery was used as a single graft in 10 patients, as a sequential graft in 25 patients, and two grafts in 1 patient. Twenty patients underwent associated procedures coronary endarterectomy (14), coronary artery patch angioplasty (4), mitral valve repair (1), and repair of ventricular septal rupture (1). One patient died of low cardiac output syndrome and the others had no perioperative myocardial infarction. There are no ischemic and functional complications in the arm or hand aftcr removal of the radial artery. Only 1 patient required reexploration of the am, for the hematoma evacuation, and 2 patients complained transient thumb dysesthesia of the side of the havested arm. This dysesthesia improved within one month. Postoperative angiovaphic controls were obtained in 11 patients(31%) postoperative 79 to 210 days (mean 126 days). The patency rate were as follows : left internal mammary artery (100%), saphcnous vein (100%), and radial artery(95%). We concluded that the radial artery is useful alternative graft, but long term clinical and angiographic studies are required to derterminc whether wider application is warranted.

  • PDF

The Surgical Treatment of Atrial Fibrillation in Patients Undergoing Simultaneous Open Heart Surgery (심장세동의 수술요법)

  • Kim, Gi-Bong;Lee, Chang-Ha;Son, Dae-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.287-292
    • /
    • 1997
  • .Itrial fibrillation is one of the most common cardiac arrhythmias requiring treatment. About 60% of patients with mitral valvular disease have atrial fibrillation and one third of patients with atrial fibrillation may have the past history of thromboembolic events. Between April 1994 and June 1995, 20 patients with organic heart diseases combined with atrial fibrillation underwent open heart surgery including Cox-maze 111 procedure. There were 6 men and 14 women with an average age of 48 years (range, 31 to 66 years). Nineteen patients had valvular heart diseases and 1 ventricular septal defEct (VSD). Mean duration of atrial fibrillation was 36 months (:42 months) (range, 1 to 132 months). T e past medical history of thromboembolic events was positive in 7 patients (35%) and left atrial thrombus was detected in 9 patients (45%). The concomitant procedures were mitral valve replacement (MVR) and aortic valve replacement (AVR) in 5 patients, MVR in 4, MVd and tricuspid annuloplasty(TAP) in 4, mitral valvuloplasty(Mln) in 3, Mln and Tln in 1, MIW and coronary artery bypass surgery in 1, AVR in 1, and patch closure of VSD in 1. Mean aortic cross-clamping time was 175 minutes (range, 116 to 270 minutes). Atrial fibrillation recurred in 16 patients (80%) during the early postoperative period, but, recurrent atrial fibrillation was converted to regular rhythm at postoperative forty-first day in average. There was no early or late death in this series of 20 patients and postoperative complications were inappropriate tachycardia in 5 patients (25%), low cardiac output syndrome in 3 (15%), aggravated hemiplegic in 1, and acute renal failure in 1. Mean follow-up interval of patient was 16.5 months (range, 10.5 to 24 months) and all patients are currently in regular rhythm. Seventeen patients (85%) are in sinus rhythm and 3 (15%) in junctional rhythm. Right atrial contraction was detected in 95% of patients and left atrial contraction in 63% on postoperative transthoracic echocardiogram. The surgical treatment of atrial fibrillation concomitant with open heart surgery is warranted in the recent clinical setting of improved myocardial protection technique, considering the untoward side-effects of atrial fibrillation.

  • PDF

Emergency Coronary Artery Bypass Operation for Card iogen ic Shock (심인성 쇼크에 대한 응급 관상동맥 우회술)

  • 김응중;이원용
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.966-972
    • /
    • 1997
  • Between June 1994 to August 1996, 13 patients underwent emergency coronary artery bypass operations. There were 3 males and 10 females and ages ranged from 56 to 80 years with the mean of 65.5 years. The indications for emergency operations were cardiogenic shock in 12 cases and intractable polymorphic VT(ve'ntricular tachycardia) in 1 case. The causes of cardiogenic shock were acute evolving infarction in 6 cases, PTCA failure in 4 cases, acute myocardial infarction in 1 case, and post-AMI VSR(ventricular septal rupture) in 1 case. Pive out of 13 patients could go to operating room within 2 hours. However, the operations were delayed from 3 to 10 hours in 8 patients due to non-medical causes. In 12 patients, 37 distal anastomoses were constructed with only 3 LITA's(left internal thoracic arteries) and 34 saphenous veins. In a patient with post-AMI VSR, VSR repair was added. In a patient with intractable VT and critical sten sis limited to left main coronary artery, left main coronary angioplasty was performed. Pive patients died after operation with the operative mortality of 38.5%. Three patients died in the operating room due to LV pump failure, one patient died due to intractable ventricular tachycardia on postoperative second day, and one patient died on postoperative 7th day due to multi-organ failure with complications of mediastinal bleeding, low cardiac output syndrome, ARF, and lower extremity ischemia due to IABP. In 8 survived patients, 3 major complications (mediastinitis, PMI, UGI bleeding) developed but eventually recovered. We think that the aggressive approach to critically ill patients will salvage some of such patients and the most important factor for patient salvage is early surgical intervention before irreversible damage occurs.

  • PDF

Development of New Device to Improve Sucess Rate of Maze Procedure with Radiofrequency Energy (고주파에너지를 이용한 미로술식의 성적향상을 위한 새로운 기구의 개발)

  • 박남희;유양기;이재원
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2004
  • Background: The sinus conversion rate after the maze procedure in chronic atrial fibrillation using radiofrequency energy is lower than with either conventional 'cut and saw' technique or cryothermia. The creation of incomplete transmural lesions due to poor tissue-catheter contact is thought to be the main cause. To address this problem, the current study was aimed to evaluate the effectiveness of a specially constructed compression device designed to enhance tissue catheter contact during unipolar radiofrequency catheter ablation. Material and Method: Circum-ferential right auricular epicardial lesions were created with a linear radiofrequency catheter in 10 anesthetized pigs. A device specially designed to increase contact by compression of the catheter to the atrial wall was used in 5 pigs (study group). This device was not used in the control group (5 pigs). Conduction block across the right auricular lesion was assessed by pacing, and the transmurality of the lesions were confirmed by microscopic examination. Result: Conduction block was observed in a total of 8 pigs; 5 in study group and 3 in control group. Transmural injury was confirmed microscopically by the accumulation of acute inflammatory cells and loss of elastic fibers in the endocardium. In two pigs with failed conduction block, microscopic examination of the endocardium appeared normal. Conclusion: Failed radiofrequency ablation is strongly related to non-transmural energy delivery. The specially constructed compression device in the current study was successful in creating firm tissue-catheter contact and thereby generating transmural lesions during unipolar radiofrequency ablation.

Assessment of the Quality of Esophago-gastric Anastomosis by Endoscopic Examination -Cervical Versus Intrathoracic Anastomosis- (내시경을 통한 식도-위 문합술의 질 평가-경부와 흉부 문합의 비교-)

  • Shim, Jae-Hoon;Kim, Hyun-Koo;Baek, Man-Jong;Kim, Hark-Jei;Choi, Young-Ho
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.920-926
    • /
    • 2006
  • Background: Mortality and morbidity of anastomotic complications after esophagectomy have gradually decreased in recent years. However, swallowing difficulties and reflux symptoms after esophagogastrostomy continue to be a burden jeopardizing the quality of life. In the present study, we evaluated the quality of esophagogastrostomy by analyzing anastomotic stenosis and reflux esophagitis. Material and Method: A retrospective analysis was made in 74 patients who underwent esophagogastrostomy after esophagectomy by one surgeon between January 1995 and December 2004. 53 patients of them received endoscopic examination during follow-up($29{\pm}23.6$ months, range $5{\sim}111$ months). Reflux esophagitis and stenosis at anastomostic site were analyzed according to the techniques and locations of esophagogastrostomy. Result: The median age at the time of repair was $60.3{\pm}8.87$ years(range $39{\sim}81$ years). 23 patients received a hand-sewn esophagogastric anastomosis and 30 patients a circular stapled one. There was no significant statistical difference in terms of anastomotic stenosis(p=0.64) and reflux esophagitis(p=0.41) between the two groups. Cervical anastomosis was peformed in 26 patients and intrathoracic anastomosis in 27 patients. No significant statistical difference in anastomotic stenosis between the two groups was found(p=0.44), but reflux esophagitis was noted in 3 patients in the cervical anastomosis group and 14 patients in the intrathoracic anastomosis group(p=0.003). Conclusion: Cervical anastomosis was supposed to have a better quality of esophagogastrostomy by lowering the risk of reflux esophagitis. In the future, the comprehensive study including a patient's subjective symptom and Barrett's metaplasia should be performed in larger cases.

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

Transaortic Mitral Commissuroplasty with a Bentall Procedure or Artic Valve Replacement (대동맥 판막 치환술과 벤탈 수술 환자에서 대동맥 근부를 통한 승모판막 교련 성형술)

  • Kim, Si-Wook;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.727-732
    • /
    • 2007
  • Background: The reciptents of aortic valve replacement or a Bentall operation usually display various degrees of mitral regurgitation. When deciding whether or not to correct the mitral regurgitation, one must consider its severity, underlying causes and operative risk. Recently, the operation method for correcting the concomitant mitral regurgitation has been done through aortic root to reduce the operation time and the cardiac trauma. We report our experiences that transaortic mitral valve commissuroplasty done with aortic valve replacement or a Bentall operation has been a simple, less invasive, effective method in the operative management of mitral valve regurgitation without significant organic changes. Material and Method: Between June 2002 and June 2005, twenty patients under-went mitral valve commissuroplasty via the aortic root with aortic valve replacement (n=14) or a Bentall operation (n=7). The mitral valve regurgitation of the patients didn't exceed a moderate (grade 2) degree and there was no significant organic disease. The preoperative diagnosis of MR was established by TTE and intraoperative TEE, and the patients were followed postoperatively by TTE. The operative technique was a simple anterolateral commissuroplasty of the mitral valve with a single mattress suture via the transaortic annular approach after excision of the aortic valve leaflets. Result: The mean patient age was 56.2 years and 65% (n=13) were male. The preoperative MR was mild (grade 1) in 9 (45%), mild to moderate in 8 (40%), and moderate (grade 2) in 3 (15%) patients. There were no operative mortalities. The MR improved in all patients (p=0.002) and the left ventricular ejection fraction (LV EF) improved in 14 (70%) patients (p=0.005). The mean cross-clamp time for the patients who under- went aortic valve replacement with transaortic mitral repair was $62.1{\pm}13.9 min$ and this was $137.5{\pm}7.2 min$ for the patients who underwent a Bentall operation with transaortic mitral repair. Conclusion: For selected patients without significant mitral organic disease, transaortic mitral valve commissuroplasty combined with aortic valve replacement or a Bentall operation may be a feasible, effective method without adding significant aortic cross clamping time and more cardiotomy.

Closure of Atrial Septal Defects through a Video-assisted Mini-thoracotomy (흉강경하 최소절개를 이용한 심방중격결손의 폐쇄)

  • Min, Ho-Ki;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo-Won;Choi, Seon-Uoo;Park, Seung-Woo;Min, Sun-Kyung;Lee, Jae-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.568-572
    • /
    • 2008
  • Background: Minimally invasive surgery is currently popular, but this has been applied very sparingly to cardiac surgery because of some limitations. Our study evaluated the safety and efficacy of atrial septal defect (ASD) closure through a video-assisted mini-thoracotomy. Material and Method: Fifteen patients were analyzed. Their mean age was $31{\pm}6$ years. The mean ASD size was $24{\pm}5mm$ and there were 3 cases of significant tricuspid regurgitation. The working window was made through the right 4th intercostal space via a $4{\sim}5cm$ inframammary skin incision, CPB was conducted with performing peripheral cannulation. After cardioplegic arrest, the ASDs were closed with a patch (n=11) or direct sutures (n=4), and the procedures were assisted by using a thoracoscope. There were 3 cases of tricuspid repair and 1 case of mitral valve repair. The mean CPB time and aortic occlusion time were $160{\pm}47\;and\;70{\pm}26 $minutes, respectively. Result: There was no mortality, but there were 3 minor complications (one pneumothorax, one wound dehiscence and one arrhythmia). The mean hospital stay was $5.9{\pm}1.8$ days. The mean follow-up duration was $10.7{\pm}6.4$ months. The follow-up echocardiogram noted no residual ASD or significant tricuspid regurgitation. Three patients suffered from pain or numbness. Conclusion: This study showed satisfactory clinical and cosmetic results. Although the operative time is still too long, more experience and specialized equipment would make this technique a good option for treating ASD.