• Title/Summary/Keyword: 봉합부의 연속성

Search Result 7, Processing Time 0.02 seconds

Arthroscopic Repair of Traumatic Subscapularis Tendon Tear (외상성 견갑하건 파열의 관절경하 봉합술)

  • Cho, Su-Hyun;Cho, Hyung-Lae;Ku, Jung-Hoei;Hwang, Tae-Hyok;Park, Man-Jun;Choi, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Purpose: Rotator cuff tears involving the subscapularis are less common than those involving the superior and posterior rotator cuff. The purpose of the present study was to report the clinical results of repair of isolated traumatic tears of the subscapularis tendon. Materials and Methods: Fifteen patients (13 males, 2 females; mean age 46.2 years; range 35 to 52) with unilateral ruptures of the subscapularis tendon after trauma who underwent arthroscopic repair between February 2003 and October 2008 were reviewed retrospectively. All the cases were isolated tears of the subscapularis without the involvement of any other rotator cuff tendon and were followed for at least two years (mean 28 months). The entire subscapularis was involved in 9 cases and the tear was localized to the upper two thirds in 6 cases. The preoperative and postoperative status of patients with isolated subscapularis tears were analyzed using the Constant Score, American Shoulder and Elbow Society Index (ASES Index) and postoperative integrity was determined through magnetic resonance imaging. Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up. The constant shoulder score improved from 41.5 to 81.3 points (P<0.05) compared to before surgery and ASES index improved from 46.4 to 89.6 points (P<0.05) postoperatively. Thirteen patients (87%) were satisfied with the result of the treatment. The total tears were significantly more improved by surgery than the partial tears. In 12 of 15 patients (80%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 13 months postoperatively. The postoperative score was significantly lower for the patients with a failed repair than it was for those with an intact repair (P<0.05). Conclusion: Repair of traumatic isolated subscapularis tears through arthroscopic techniques effectively restores patient function with regard to pain, mobility, strength and postoperative tendon integrity. The postoperative integrity of the repair correlates with the functional results and the total tears were more improved by surgery than the partial tears, but future studies may be needed.

  • PDF

The results of arthroscopic repair according to the delamination of rotator cuff (회전근 개 판분리 파열에 따른 관절경하 회전근 개 봉합술의 결과)

  • Ku, Jung Hoei;Cho, Hyung Lae;Park, Man Jun;Kim, Jeong Cheol
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Purpose: We evaluated the clinical outcome after arthroscopic repair in full thickness rotator cuff tears with and without delamination. Materials and Methods: From March 2006 to October 2008, we included 48 consecutive shoulders (31 males, 17 females; mean age 57.6 years; 45~68) who had arthroscopic double row repair for fullthickness tears of the rotator cuff. Mean rotator cuff tear size was 2.8 cm (range: 1.2~3.6) and the techniques of tendon-to-bone fixation varied according to the presence of delamination; separate row fixations of bursal and articular layer were used in delaminated tear. The mean follow-up was 26 months (range: 18~33) and functional and structural results were evaluated by American Shoulder and Elbow Surgeons (ASES), University of California at Los Angeles (UCLA) scale, isokinetic strength testing and magnetic resonance imaging (MRI) obtained mean 8 months (range:6~13) postoperatively. The patterns of delamination, age, sex, symptom duration, size of tear, satisfaction rate, retear rate ware compared and significance was set at p values < 0.05. Results: Postoperative functional shoulder score improved significantly in 44 shoulders (91.7%). Delamination was observed in 15 shoulders (31%) and it extended proximally and posteriorly in the majority of shoulders, and the articular layer was thicker (8/15, 53%) and more retracted (9/15, 60%) compared with the superficial bursal layer. Final follow up functional shoulder scores showed no differences between non-delaminated and delaminated tears and the presence of delamination had no correlations with sex, symptom duration, tear size and satisfaction rate, however, older age had more delaminated tears (p=0.041). Follow up MRI in 29 shoulders revealed that fourteen (48%) shoulders had complete healing; nine (31%), partial healing; six (21%), complete retear but the half of the retear group showed favorable clinical results. 79% (15/19) in non-delaminated tear and 80% (8/10) in delaminated tear were judged as healed tendon on MRI and double-layer double row repairs in delaminated tears resulted in nearly same rate of structural integrity of single-layer double row repairs (p=0.165). Conclusion: The incidence of delamination in our series was 31% and older age had more delaminated tears. Sex, symptom duration, preoperative size of the tear, functional results and satisfaction rate had no significant correlations with the presence of delamination. Nearly the same postoperative structural integrity was noted in both delaminated and non-delaminated tears.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF

An Unusual Delayed Pseudoaneurysm That Originated from a Bypass Suture Site and It Was Revealed to Be an Organizing Thrombus 7 Years an Extraanatomic Bypass - A case report - (외해부학적 우회술 7년 뒤에 발생되어 기질성 혈전으로 밝혀진 우회술 봉합 부위에서 야기된 드문 양상의 지연성 가성동맥류 - 1예 보고 -)

  • Lee, Woo-Surng;Kim, Yo-Han;Chee, Hyun-Keun;Hwang, Jae-Joon;Kim, Jun-Seok;Lee, Song-Am
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.532-536
    • /
    • 2009
  • Bypass surgery is performed for insuring continuity of a blood supply that is restricted due to obstruction of the native blood supply. Two types of surgery are commonly carried out: one is anatomic bypass and the other is extraanatomic bypass. Especially, extraanatomic bypass surgery is performed in patients who are a high risk for performing anatomical bypass surgery. The risk factors for anatomical bypass surgery are old age, infection, previous surgery and trauma. A 96-year-old patient underwent extraanatomic bypass surgery from the right femoral artery to the left femoral artery due to total occlusion of the left iliac artery, and 7 years after that operation, a pseudoaneurysm abruptly and spontaneously appeared from the bypass suture site without any predisposing factor. The lesion was revealed to be an organizing thrombus.

Surgical Treatment of Main Pulmonary Artery Aneurysm with Patent Ductus Arteriosus -A Case Report- (동맥관개존증에 동반된 주폐동맥류의 수술치험 - 수술치험 1례)

  • 김대식;이성주;권오우;김창회;채성수;오성철
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1270-1275
    • /
    • 1996
  • Pulmonary artery aneurysms are extremely rare conditions usually associated with congenital cardiac defects that cause increased pulmonary blood flow and pulmonary hypertension. The prognosis of pulmonary artery aneurysms is fatal due to the potential for rupture of the aneurysm and the underlying severe pulmonary hypertension. A 40-year old woman was admitted to our hospital with headache following traffic accident. On admission a continuous murmur was heard over the 2nd to 3rd intercostal space along left sternal border and a calcified cystic mass at left hilar portion was incidentally discoverd on chest reontgenogram. Cardiac catherization was diagnostic of a left to right shunt at main pulmoanry artery level and pulmonary hypertension. Pulmonary angiogram demonstrated a large aneurysm of main pulmonary artery extending into proximal left pulmonary artery. The pulmonary artery aneurysm associated with patent ductus arteriosus was diagnosed definitively and the patient was underwent resection of pulmonary artery aneurysm, closure of PDA and Dacron prosthetic graft replacement under cardiopulmonary bypass. The postoperative course was uneventful and the patient was discharged without any problem.

  • PDF

Cosmetic Thoracic Sympathectomy for Palmar Hyperhidrosis using 2mm Thoracoscopic Instruments (다한증 환자에서 2 mm 흉강경 기구를 이용한 미용적 교감신경절제술)

  • 성숙환;최용수;조광리;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.525-530
    • /
    • 1998
  • Thoracoscopic thoracic sympathectomy for primary palmar hyperhidrosis has been known to be effective and to have cosmetic merits compared to conventional open sympathectomy. In spite of its cosmetic advantages over thoracotomy, VATS using 5 mm or 10 mm instruments still has the problem of operative wound as well as pain on trocar sites. Recently, 2 mm thoracoscopic instruments have been used. The purpose of this study was to examine the results of thoracoscopic sympathectomy for palmar hyperhidrosis with 2 mm thoracoscopic instruments. From January 1997 to April 1997, 46 patients underwent bilateral thoracoscopic sympathectomy with 2mm instruments at Seoul National University Hospital. T-2 ganglion was carefully dissected and resected out in all patients. In one patient, the lower third of T-1 ganglion was inadvertently resected together with T-2 ganglion due to poor anatomical localization. In 4 patients who also complained of excessive axillary sweating, T-3 ganglion was resected as well. The instruments were removed without leaving any chest drain after reexpansion of the lung. Trocar sites were approximated with sterile tapes. All patients were relieved of excessive sweating in their upper extremities immediately after the operation. Nine patients(19.6%) showed incomplete reexpansion of the lung, and two of them required needle aspiration. Complications related to the surgical procedures, such as Horner's syndrome, hemothorax, and brachial plexus injury, were not detected in any cases. Most patientsdid not complaine of pain. All patients were discharged from the hospital on the day of operation. Despite a narrow operative viewfield, thoracic sympathectomy with 2 mm thoracoscopic instruments can be performed without increasing any severe complications. We recommend 2 mm instruments for thoracoscopic sympathectomy because they make as the more cosmetic, less painful, and equally effective compared to thoracoscopic sympathectomy using 5 mm or greater instruments.

  • PDF