A Study of the Optimum Installation Number of Face Bolts Using Laboratory Tests and Numerical Analysis (실내실험 및 수치해석을 이용한 막장볼트의 최적 타설 개수에 관한 연구)

  • Seo, Kyoung-Won;Kazuo, Nishimurn;Kim, Chang-Young
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.467-475
    • /
    • 2006
  • The use of face bolt method has been increasing abroad recently. Hence, many tests and measurements are being conducted and reported. Also, it is well hewn that determination of the installation number of foe bolts in the design stage is very difficult due to difference of the ground condition and the type of a bolt to be used. First of all, the type, the number, etc. of bolts used in various tunnel construction sites, investigated, are analyzed. The relationship between bolt and ground condition could not be found because bolts have been used with the other support methods in many cases. In the laboratory test and numerical analysis based on the site investigation, the behavior of ground and pipes installed on the tunnel face to support has been examined. Especially, the installed number is focused on. According to the result of tests, the surface settlement and the axial displacement of the face decrease exponentially as the number of installed bolts increases.

Estimation of Safety and Economical Efficiency of Large High Tension Bolted Joints (대직경 고장력볼트 이음부의 안전성 및 경제성 평가)

  • Sung, Ki-Tae;Kyung, Kab-Soo;Lee, Seung-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.97-105
    • /
    • 2009
  • This study was conducted for the purpose of examinating the safety and economical efficiency of large high tension bolted joints. The specimen using F10T-M30 large high strength bolts has been selected and static tensile test has been conducted to evaluate the slip characteristics. In addition, finite element analysis has been carried out to estimate the number of required bolts. As a result, the average slip coefficient of M30 high strength bolts exceeded 0.4 - the standard in highway bridge design specification - and has satisfied the slip strength, which is the same as that of M22 high strength bolts. In addition, if F13T-M22 high strength bolts were applied, the number of required bolts decreased by 21%, and if F10T-M30 high strength bolts were applied, the number of required bolts decreased by 46%, that leads to the conclusion that the economical efficiency in accordance with diametering of high strength bolts was now verified.

The Effect of the Variation of the Number of Bolts on the Rotational Stiffnesses of Double Angle Connections (볼트수의 변화가 더블앵글 접합부의 회전강성에 미치는 영향)

  • Yang, Jae-Geun;Kim, Ho-Keun;Kim, Ki-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.1 s.11
    • /
    • pp.69-75
    • /
    • 2004
  • In the construction of row-rise steel buildings, double angle connection can be considered as one of most effective connection types. Its connection flexibility depends mainly on several parameters such as angle thickness, bolt gage distance, and number of bolts. To establish the effect of the variation of the number of bolts on the moment-rotation relationship, three experimental tests have been conducted in this research. Based on the results of each experimental test, the rotational stiffness of each angle specimen can be calculated by performing regression analysis. Considering the results of regression analysis, we concluded that the more the number of bolts used in double angle connection, the higher the rotational stiffness as one can expected.

  • PDF

Seismic Performance of Beam-to-column Weak-axis Moment Connection of Small-size Steel Structure (소규모 철골조 보-기둥 약축 모멘트 접합부의 내진성능)

  • Lim, Woo-Young;You, Young-Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.169-180
    • /
    • 2017
  • Cyclic loading tests for beam-to-column weak-axis connections were performed to investigate the seismic performance. In this study, the connections were developed to improve the constructability on the basis of investigation for existing small-size steel structures. The primary test parameter is the number of high-tension bolts which are used to connect steel beam and column using exterior and interior flange plates. Test results showed that the number of bolts had a significant effect on the cyclic behavior of beam-column weak-axis connections. From the analysis of test results, it is concluded that more than four bolts in the connections can satisfy the requirements of semi-rigid connection presented in current design codes. All of specimens showed the bearing failure around bolt holes and fracture at the beam flange. However, when the web height and the flange width is relatively small, the number of the bolts used in the connections might be limited. Thus, the additional research in this area is needed.

Development of Numerical Analysis Model for the Behavior Analysis of Bolted Connection (볼트 접합부의 거동 해석을 위한 수치해석 모델 개발)

  • Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.1-9
    • /
    • 2007
  • To analyze the behavior of multiple bolted connection with analytical method, there was a major problem in terms of the number of bolt as two. Multiple bolted connection is wrong in other way, that is impossible to analyze the behavior of connection with various types. So the numerical analysis model was developed to analyze the behavior of connection with various types, and to overcome the limitation of number of bolt. The optimum values for analysis the behavior of multiple bolted connection with numerical methods were obtained as, r=0.35, Kx=137.5, and Ky=257.4. The numerical analysis method was developed in this study showed high efficiency for the existing methods in the behavior analysis of connection.

A Laboratory Test and Numerical Analysis to Determine the Number of Additional Installation of Face Bolts due to the Deviated Bolts from the Horizontal Direction (막장볼트가 수평으로부터 벗어나는 경우 추가해 주어야 하는 본수에 대한 실내실험 및 수치해석)

  • Seo, Kyoung-Won;Lee, Sung-Won;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.345-354
    • /
    • 2006
  • During installation of face bolts, they are often deviated from the designed horizontal direction. In this study, a laboratory test and numerical analysis were conducted to examine the change of support effect by them. Also, the number of bolts to be added for achieving the designed support effect was considered. It was verified in this study that the horizontal installation is more effective. Under the test condition of this study, 1.5 bolts/section should be added in the face of which the installation density was 3 bolts/section when the bolts were installed with $R15^{\circ}$ angle from the horizontal position.

Convolutional Neural Network-based Prediction of Bolt Clamping Force in Initial Bolt Loosening State Using Frequency Response Similarity (초기 볼트풀림 상태의 볼트 체결력 예측을 위한 주파수응답 유사성 기반의 합성곱 신경망)

  • Jea Hyun Lee;Jeong Sam Han
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.221-232
    • /
    • 2023
  • This paper presents a novel convolutional neural network (CNN)-based approach for predicting bolt clamping force in the early bolt loosening state of bolted structures. The approach entails tightening eight bolts with different clamping forces and generating frequency responses, which are then used to create a similarity map. This map quantifies the magnitude and shape similarity between the frequency responses and the initial model in a fully fastened state. Krylov subspace-based model order reduction is employed to efficiently handle the large amount of frequency response data. The CNN model incorporates a regression output layer to predict the clamping forces of the bolts. Its performance is evaluated by training the network by using various amounts of training data and convolutional layers. The input data for the model are derived from the magnitude and shape similarity map obtained from the frequency responses. The results demonstrate the diagnostic potential and effectiveness of the proposed approach in detecting early bolt loosening. Accurate bolt clamping force predictions in the early loosening state can thus be achieved by utilizing the frequency response data and CNN model. The findings afford valuable insights into the application of CNNs for assessing the integrity of bolted structures.

Multi-biometric feature based fuzzy vault (다중 생체 특징 기반 퍼지볼트)

  • Sohn, Ho-Sik;Ro, Yong-Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.1057-1060
    • /
    • 2008
  • 생체 암호 시스템에서 키로 사용하는 인간의 생체 특징은 외부 환경이나 인간적 요소를 포함하고 있기 때문에 항상 같은 개수, 같은 값의 데이터를 얻을 수 없는 불확실성을 가지고 있다. 퍼지볼트 체계 (Fuzzy vault scheme) [1]는 이러한 불확실성을 가지고 있는 데이터의 특성을 효과적으로 반영 할 뿐만 아니라, 등록된 생체 데이터의 보안을 보장해 주는 알고리즘으로서 얼굴, 지문이나 홍채와 같은 단일 생체 특징으로의 적용 방법이 소개되어 왔다 [2,4,5]. 본 논문에서는 퍼지볼트 시스템의 인식 성능을 높이기 위해 이러한 단일 생체 데이터의 불확실성을 보완할 수 있는 다중 생체 특징 (얼굴과 지문) 데이터를 퍼지볼트 체계에 적용하는 방법을 제안하고 실효성을 검증한다.

Real-time Health Monitoring of Pipeline Structures (배관 구조물의 상시 건전성 모니터링)

  • Kim, Ju-Won;Kim, Tae-Heon;Lee, Chang-Gil;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.666-669
    • /
    • 2010
  • 여러 가지 지하시설물 중 국가 주요 자원의 수송망을 책임지는 주요구조물인 수도관, 가스관등의 배관구조물은 접근이 쉽지 않은 지하공간에 복잡하게 연결되어 있어 그 중요성에 비해 유지, 관리, 보수가 쉽지 않았다. 이러한 배관구조물을 균열, 조인트 풀림 등의 손상으로부터 보다 안전하고 효율적으로 관리하기 위하여 상시적 배관구조물 손상진단기법을 연구하였다. 이를 위해 배관 구조물 시험체에 볼트풀림, notch 등과 같은 손상에 대하여 대표적인 압전센서인 PZT와 MFC를 부착하고 임피던스기법 및 유도 초음파기법을 적용하여 볼트풀림개수, notch 손상개수 증가에 따른 출력신호를 반복 계측하였다. 객관적인 평가를 위해 계측된 신호를 신호처리기법인 웨이블렛 변환을 수행하고, RMSD 및 1-CC의 손상지수를 사용하여 구조물손상을 정량화 시켰으며 이를 토대로 구조물의 건전성의 기준이 되는 임계값을 설정함으로서 임피던스와 유도초음파 두 검색기법을 이용한 상시적 배관구조물 건전성 모니터링의 가능성을 살펴보았다.

  • PDF

An Analytical Model for Calculating Initial Stiffnesses of Double Angle Connections (더블앵글 접합부의 초기강성 산정을 위한 해석모델)

  • Yang, Jae-Guen;Kim, Ki-Hwan;Kim, Ho-Keun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.4 s.14
    • /
    • pp.55-63
    • /
    • 2004
  • Double angle connections are commonly used for the construction of the low-rise steel framed buildings. Several experimental tests lave been conducted to investigate the effect of the number of bolts on the rotational stiffness of a double angle connection. Several parameters are obtained by performing regression analysis. An analytical model has been introduced to calculate the initial stiffness of a double angle connection in this research.

  • PDF