• Title/Summary/Keyword: 복합 치아종

Search Result 38, Processing Time 0.022 seconds

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

Research on Natural Medicine for Wellness and Oral Health (웰니스 및 구강질환억제를 위한 천연물 유래물질 연구)

  • Park, Hae-Ryoung;Hong, Suk-Jin
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.357-363
    • /
    • 2015
  • This study investigated the antioxidant and anti-inflammatory effects of Galla Rhois (Rhus verniciflua) on LPS (lipopolysaccharide)-stimulated human osteoblastic cells (MG-63). The aim of this study was to evaluate the LPS induced nitric oxide (NO) production and antioxidant radical in human osteoblast-like MG-63 cells. Therefore, the present work indicate that Galla Rhois extracts may be an ideal candidate for further research into their use for dental caries prevention component as well as, natural plant-based products. This suggested that 80% methanol and hexane extracts of Galla Rhois were inhibited NO generation and 1,1-diphenyl-2-pirylhydrazyl (DPPH) radical. Therefore, 80% methanol and hexane extracts of Galla Rhois may be utilized as a good source of protection against inflammation and oxidative stress. This study is intended to pursue wellness convergence in quality of life in the excavations in natural ingredients to create a variety of oral products with fewer side effects, cheap oral products for the dental treatment.

Effect of the additional application of a resin layer on dentin bonding using single-step adhesives (중간층 레진 적용이 단일 접착과정 상아질 접착제의 접착에 미치는 영향)

  • Choi, Seung-Mo;Park, Sang-Hyuk;Choi, Kyung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.313-326
    • /
    • 2007
  • The purpose of this study was to prove that an intermediate resin layer (IRL) oan increase the bond strength to dentin by reducing the permeability of single-step adhesives. Flat dentin surfaces were created on buccal and lingual side of freshly extracted third molar using a low-speed diamond saw under copious water flow. Approximately 2.0 mm thick axially sectioned dentin slice was abraded with wet #600 SiC paper. Three single-step self-etch adhesives; Adper Prompt L-Pop (3M ESPE, St Paul, MN, USA), One-Up Bond F (Tokuyama Corp, Tokyo, Japan) and Xeno III (Dentsply, Konstanz, Germany) were used in this study. Each adhesive groups were again subdivided into ten groups by; whether IRL was used or not; whether adhesives were cured with light before application or IRL or not; the mode of composite application. The results of this study were as follows; 1. Bond strength of single-step adhesives increased by an additional coating of intermediate resin layer, and this increasement was statistically signigicant when self-cured composite was used (p < 0.001). 2. When using IRL, there were no difference on bond strengths regardless the curing procedure of single-step adhesives. 3. There were no significant difference on bond strengths between usage of AB2 or SM as an IRL. 4. The thickness of Hybrid layer was correlated with the acidity of adhesive used, and the nanoleakage represented by silver deposits and grains was examined within hybrid and adhesive layer in most of single-step adhesives. 5. Neither thickness of hybrid layer nor nanoleakage were related to bond strength.

EFFECT OF CALCIUM HYDROXIDE ON BOND STRENGTH OF DENTIN BONDING SYSTEMS (수산화칼슘 적용에 따른 상아질 접착제의 접착강도 변화에 관한 연구)

  • Park, No-Hoon;Park, Sang-Hyuk;Choi, Gi-Woon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.198-207
    • /
    • 2007
  • The purpose of this study was to investigate the effect of calcium hydroxide on dentin bonding strength of various dentin bonding systems as a function of time in composite resin restoration. Dentin adhesives used in this study were Scotchbond Multipurpose, Single Bond, SE Bond and Prompt L-Pop. Flat dentin surfaces adjacent to pulp chamber were created, then $Ca(OH)_2$ and saline were mixed and applied on dentin surface of experimental group, then IRM was used to cover the mixture on dentin surface and the specimens were stored at $36.5^{\circ}C$ for experiment period (7 days, 30 days). After removing IRM and $Ca(OH)_2$, each dentin adhesives were treated on dentin surfaces. Composite resin (Z-250, 3M) was placed with S mm height and was light-cured for 20 seconds. After stored in distilled water for 24 hours, each dentin-composite bonded spicemen was embedded in epoxy resin and sectioned into $1.0\times1.0mm^2$ cross section composite-dentin beams. Specimen was mounted on zig of Universal testing machine and ${\mu}TBS$ test was performed. SEM analysis was performed to examine the fractured surfaces. The results suggested that applying calcium hydroxide did not show significant difference in dentin bonding strength.

A MORPHOMETRIC STUDY ON THE PRIMARY MOLARS AND PREFORMED STAINLESS STEEL CROWN (유구치 치관 및 기성금속관의 크기에 관한 계측학적 연구)

  • Choi, Ji-Eun;Cheong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.355-362
    • /
    • 2001
  • Data derived from odontometric studies are useful in many areas. Especially crown diameter of primary teeth is important in not only anthropology but also clinical dentistry. The purposes of this study were to compare diameters of primary molars of Korean children with those of preformed stainless steel crown, and examine racial characteristics of primary molars of Korean children. The mesiodistal and buccolingual diameters of primary molars were measured on dental casts taken from 235 children(male 105, female 131), with digital calipers. And the data were compared with those of preformed stainless steel crowns. The results were as follows; 1. No significant difference was observed between the right and left members of antimeric teeth and all primary molars of male were larger than those of female. 2. The diameters of primary molars of Korean are smaller than those of Austrailian aborigines and there was significant difference between diameters of primary molars of Korean and those of other populations. 3. There were size differences between diameters of maxillary, mandibular first molar and preformed stainless steel crown than other primary molars, relatively.

  • PDF

A STUDY ON THE SIZE OF THE PERMANENT TEETH (영구치의 치아크기에 관한 연구)

  • Baik, Byeong-Ju;Park, Jeong-Yeol;Kim, Jae-Gon;Lee, Doo-Cheol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.502-509
    • /
    • 2003
  • After 800 students of Chonbuk National University was examined, 86 people (male : 43, female : 43, mean age : 22.2 years old) was selected as a group of normal occlusion. From their gypsum cast, this conclusion was obtained. 1. Intra-observer measurement errors in buccolingual diameter, maxillary lateral incisors have somewhat bigger errors. In mesiodistal diameter, maxillary first molars and maxillary second molar have bigger numerical value. Mean errors of measurement are 0.051mm at buccolingual diameter of crown and 0.083mm at mesiodistal diameter. 2. Fluctuating asymmetry is 0.030 average in buccolingual diameter, and 0.037 average in mesiodistal diameter. Statistically there are no big differences. 3. Male has longer buccolingual diameter than female in every permanent teeth. Teeth which have statistical difference in buccolingual diameter are maxillary lateral incisor, maxillary canine, maxillary second molar, mandibular central incisor, mandibular canine, mandibular second premolar, and mandibular first molar. In mesiodistal diameter maxillary central incisor, maxillary canine, and mandibular first molar have statistically difference. 4. Tooth which has the biggest difference depending on gender is maxillary lateral incisor in buccolingual diameter and mandibular canine in mesiodistal diameter. 5. Both sexes have similar crown index. Male has bigger value of crown module measurement and crown area measurement in every tooth. Crown area considered as size of tooth from occlusal surface was bigger in male than in female statistically except some teeth, maxillary first premolar, mandibular lateral incisor, first premolar and second premolar.

  • PDF

Color and surface change of teeth restoration result of treatment of fruit extracts (과일추출물 처리에 따른 치아수복물의 색조 및 표면변화)

  • Choi, Eun Jung;Kim, Mi-Jin;Kim, Min-Ji;Park, Min-Ji;Shim, So-Yeon;Oh, Su-Jin;Lee, Ah-Min;Yang, Seok-Jun;Kang, Kyung-hee
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.449-457
    • /
    • 2016
  • At this study, we select five colorful and high-acid fruits: grape, lemon, orange, grapefruit and kiwi, and we made a composite resin specimen and dipped into fruit juice in order to figure out influence that affects on surface corrosion and coloring. We dipped resin specimen into fruit juice by three-day and seven-day interval at $37^{\circ}C$. Control group used the resin that was not dipped into fruit juice. For surface change according to the time, it was observed by using scanning electron microscopy, and it was measured by using spectrophotometer for change of coloring degree. As a result of surface change of resin by using scanning electron microscopy, furrow size between surface particles increased, and rectangular rod-shape structure was emerged, and small prominent particles on bumps disappeared. As a result of coloring degree of resin by measuring spectrophotometer, a difference between experimental group appears with the darkest brightness in the case where it is dipped into grape extracts.

CHEMICAL DEGRADATION OF LIGHT-CURED DENTAL COMPOSITE RESINS (수종 치과용 광중합형 복합레진의 화학적 분해)

  • Yang, Kuy-Ho;Choi, Nam-Ki;Park, Mi-Ran;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.403-411
    • /
    • 2001
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Unifil(GC, Japan), Palfique(Tokuyama Japan). Definite$Degussa-H\ddot{u}ls$ AG, Germany). Revolution(Kerr, U.S.A.). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. The mass loss of Unifil was 3.21%, it was the highest of materials. But, there was no significant difference among the materials. 2. The degree of degradation layer depth was $107.69\sim47.40{\mu}m$, the sequence of the degree pf degradation layer depth was in descending order by Unifil, Palfique, Revolution, Definite. There was significant difference among the materials except Palfique and Definite. 3. The Si loss of Paltique was 8940.0ppm, it was the highest. There was significant difference among the materials, except Revolution and Definite(p<0.05). 4. The correlation coefficient between mass loss and degradation depth was relatively high(r = 0.06, p<0.05). 5. There was no significant coefficient correlation between Si loss and mass loss, and/or the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler. Above results suggested that the hydrolytic degradation is considered as evaluation factor of composite resins.

  • PDF

생의학 의용을 위한 마이크로 웨이브 대기압 플라즈마 장비

  • Gang, Seong-Gil;Lee, Jae-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.259-260
    • /
    • 2011
  • 대기압 플라즈마는 멸균과 살균, 지혈, 피부재생, 치아 미백 등 여러 의학 분야를 대상으로 그 효과를 나타내고 있으며, 플라즈마 장비를 만들어 내기 위해 부피가 큰 진공 장비가 필요하지 않다는 점에서 대기압 플라즈마는 그 활용과 효과에 있어 큰 기대를 받고 있다. 대기압에서 플라즈마는 다양한 주파수를 이용하여 만들어져 왔으며, 본 연구실에서 연구하고 있는 수백 MHz-수 GHz 대역의 파워를 사용하는 플라즈마의 경우 대기압 플라즈마를 의학 분야에 사용할 때 만족해야 할 조건들에 만족하는 특성을 보여준다. 기존의 고주파를 사용하는 장비의 경우 추가적인 Matching 장비로 인해 플라즈마를 만들기 위해 큰 장비와 높은 파워가 필요한 단점이 있었다. 하지만 이 마이크로웨이브 장비는 전송선 이론을 기반으로 장비 자체가 구조적인 Matching이 이루어 지도록 설계되었다(그림 1). 즉, 추가적인 Matching 장비의 필요 없이 외부에서 파워를 주는 것만으로 플라즈마를 발생 시킬 수 있으며, 50% 이상의 파워 효율을 보여준다. 또한 그 크기도 손에 쥐고 사용할 수 있을 볼펜 정도의 크기이며, 3W의 정도의 저 전력으로 플라즈마를 발생 시켰다. 높은 에너지를 가지는 전자들은 공급되는 기체뿐만 아니라, 주변 공기와의 반응하여 여러 응용분야에 적합한 활성 종을 다량 만들어내게 된다. 본 연구실의 강점인 플라즈마 시뮬레이션으로 얻은 결과에서 주파수가 올라 갈수록 높은 에너지를 가지는 전자들이 많아지는 것을 보여준다. 그리고 발생시킨 플라즈마의 광학 특성에서도 생의학 분야에 적합한 많은 활성 종들이 발생 되는 것을 확인하였다. 일반적으로 의학 분야에 사용되는 플라즈마의 경우 플라즈마에서 발생하는 열에 의한 피해를 최소화 하는 것이 중요하다. 마이크로웨이브 플라즈마의 경우, 그 플라즈마의 온도가 50$50^{\circ}$C 미만으로 의학 분야에 사용하기 적합하다. 또한 구동 주파수가 올라갈수록 플라즈마를 유지하는데 필요한 전압이 상대적으로 낮아지게 되는데, 이는 전기적 쇼크 등 플라즈마 의용에서 발생하는 안전성 문제에 있어서도 마이크로 웨이브 장비가 좋은 점이다. 본 플라즈마 장비를 구동하기 위한 손바닥 크기 정도의 소형의 전용 파워 장치를 개발함으로써 저전력 소형 플라즈마 장치를 개발하는 것을 목표로 하고 있다. 마이크로 웨이브 장비는 여러 가지 분야에서 그 효과를 검증 받았다. 혈액 응고 실험에서 30초 정도의 짧은 처리만으로도 자연 응고에 비해 탁월한 지혈 효과를 보여줬다 (그림 2). 충치를 발생시키는 대표적인 구강균인 S.mutans의 살균 실험에서 Ti02와의 복합적인 처리를 통해 30초 미만의 처리로 처리하지 않은 것에 비해 10-6 만큼의 줄어드는 살균 효과를 보여줬다. 뿐만 아니라 치아의 미백에 있어서도 탁월한 효과를 나타냈다. 현재 본연구실에서는 마이크로 웨이브 장비의 기본적인 구조를 응용하여, 좀더 넓은 영역을 처리할 수 있는 대면적 마이크로 웨이브 장비를 위한 연구를 수행 중이다.

  • PDF

EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN (수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향)

  • Kim, Hak-Geun;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. $32\%$ phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D, dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with $1mm^2$ cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P<0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P<0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P<0.05).