• Title/Summary/Keyword: 복합형 열화 환경

Search Result 7, Processing Time 0.018 seconds

Effect of Combined Environmental Factors on Degradation Behavior of Carbon Fiber/Epoxy Composites (복합적인 환경인자의 영향에 따른 탄소섬유/에폭시 복합재의 열화 특성)

  • Hwang, Young-Eun;Lee, Gil-Hyung;Yoon, Sung-Ho
    • Composites Research
    • /
    • v.22 no.5
    • /
    • pp.37-42
    • /
    • 2009
  • Thermal analysis properties and chemical structure of carbon fiber/epoxy composites under environmental exposure were examined using an accelerated aging tester which can simulate real weather conditions such as temperature, moisture and ultraviolet. The composite specimens were exposed to combined environmental factors up to 3000 hours. Thermal analysis properties and chemical structure of the composites were evaluated with various exposure times through Modulated DSC and FTIR. According to the results of Modulated DSC, the glass transition temperature increased as exposure time increased due to the formation of network structures in the composites. Also endotherm peaks of enthalpy relaxation related to physical aging that can affect the properties of the composites were observed as exposure time increased. From the results of FTIR, it was found that the location of the peaks was little affected by exposure time, but the intensity of the peaks slightly decreased as exposure time increased due to the curing reaction in the epoxy group.

Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint (지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법)

  • Oh, Kyu-Hwan;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.

Performance Analysis of FH/MFSK System against Combined Jammer using Jammer Side Information over Rayleigh Fading Channel (레일리 페이딩 채널환경에서 재머 상태 정보를 이용한 복합재머에 대한 FH/MFSK의 성능 분석)

  • 이동형;손종원;김용로;유흥균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.8B
    • /
    • pp.1183-1188
    • /
    • 2001
  • 잡음 재밍과 톤 재밍의 혼합 재밍이 존재하는 Rayleigh 페이딩 환경에서 재머상태정보(JSI)를 이용한 FH/MFSK 시스템의 성능 향상을 분석하였다. 송신 신호와 재머 성분은 각각 Rayleigh 페이딩 환경의 영향을 받으며, 재머상태 정보는 잡음 잡음의 전력이나 톤 재밍의 크기 및 전력을 알 수 있다고 가정하였다. 분석 결과, JSI를 이용한 시스템이 잡음성 재밍의 비율 변동에 관계없이 JSI를 고려하지 않는 시스템보다 성능 향상을 얻을 수 있다. $E_{s}$ /$J_{o}$ =10[dB]인 Rayleigh 페이딩환경에서 JSI가 없는 시스템의 경우, 잡음재밍이 비율에 관계없이 최대의 성능 열화값을 갖는 톤 재밍의 비율은 0.1이나, JSI를 이용한 시스템은 다른 값을 가지게 되어, 잡음성 재밍과 톤 재밍의 적절한 비율이 시스템의 성능저하에 최대로 영향을 끼칠 수 있음을 알 수 있다.

  • PDF

Material Life Cycle Assessment on Mg2NiHx-5 wt% CaO Hydrogen Storage Composites (Mg2NiHx-5 wt% CaO 수소 저장 복합재료의 물질전과정평가)

  • Shin, Hyo-Won;Hwang, June-Hyeon;Kim, Eun-A;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.107-114
    • /
    • 2021
  • Material Life Cycle Assessment (MLCA) was performed to analyze the environmental impact characteristics of the Mg2NiHx-5 wt% CaO hydrogen storage composites' manufacturing process. The MLCA was carried out by Gabi software. It was based on Eco-Indicator 99' (EI99) and CML 2001 methodology. The Mg2NiHx-5 wt% CaO composites were synthesized by Hydrogen Induced Mechanical Alloying (HIMA). The metallurgical, thermochemical characteristics of the composites were analyzed by using X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), specific surface area analysis (Bruner-Emmett-Teller, BET), and thermogravimetric analysis (TGA). As a result of the CML 2001 methodology, the environmental impact was 78% for Global Warming Potential (GWP) and 22% for Eutrophication Potential (ETP). In addition, as a result of applying the EI 99' methodology, the acidification was the highest at 43%, and the ecotoxicity was 31%. Accordingly, the amount of electricity used in the manufacturing process may have an absolute effect on environmental pollution. Also, it is judged that the leading cause of Mg2NiHx-5 wt% CaO is the addition of CaO. Ultimately, it is necessary to research environmental factors by optimizing the process, shortening the manufacturing process time, and exploring eco-friendly alternative materials.

Study on the Estimation of Long Life Cycle and Reliability Tests for Epoxy Insulation Busway System (에폭시 박막 절연형 버스웨이 시스템의 장기 수명 및 신뢰성 평가에 관한 연구)

  • Jang, Dong-Uk;Park, Seong-Hee;Lee, Kang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.261-268
    • /
    • 2018
  • The use of electric cable was limited due to the installation time and large space as the increase of power demand and load quantity in side line. In order to solve these problems, the application of busway system which can supply the large current was increasing. But it was lack of methods of performance tests to evaluate the reliability and results of test for busway system. In this paper, we presented items to evaluate the reliability test for epoxy coated busway system with reference to IEC 61349-6. In addition, we proposed items to evaluate the reliability and long term life cycle test for the epoxy coated busway system. The combined acceleration deterioration test that reflects actual conditions of the survey as much as possible was conducted considering both thermal and electrical stresses. The deterioration condition was selected to satisfy fifty years life expectation and the insulation performance verification test of the busway system confirmed the long term life prediction. Furthermore, as test items for reliability assessment of compliance with the environment for the use of temperature, humidity and load current where busway system was installed, thermal overload test, water immersion test, cold shock temperature test and thermal cycle test were performed. And we examined changes in characteristics and abnormality after tests. From results, the test items presented to evaluate performance and reliability of the epoxy insulated busway system were confirmed to be appropriate in this paper, and the performance of the product was also confirmed to be excellent for reliability tests.

Prediction of Ultimate Strength and Strain of Concrete Columns Retrofitted by FRP Using Adaptive Neuro-Fuzzy Inference System (FRP로 보강된 콘크리트 부재의 압축응력-변형률 예측을 위한 뉴로퍼지모델의 적용)

  • Park, Tae-Won;Na, Ung-Jin;Kwon, Sung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • Aging and severe environments are major causes of damage in reinforced concrete (RC) structures such as buildings and bridges. Deterioration such as concrete cracks, corrosion of steel, and deformation of structural members can significantly degrade the structural performance and safety. Therefore, effective and easy-to-use methods are desired for repairing and strengthening such concrete structures. Various methods for strengthening and rehabilitation of RC structures have been developed in the past several decades. Recently, FRP composite materials have emerged as a cost-effective alternative to the conventional materials for repairing, strengthening, and retrofitting deteriorating/deficient concrete structures, by externally bonding FRP laminates to concrete structural members. The main purpose of this study is to investigate the effectiveness of adaptive neuro-fuzzy inference system (ANFIS) in predicting behavior of circular type concrete column retrofitted with FRP. To construct training and testing dataset, experiment results for the specimens which have different retrofit profile are used. Retrofit ratio, strength of existing concrete, thickness, number of layer, stiffness, ultimate strength of fiber and size of specimens are selected as input parameters to predict strength, strain, and stiffness of post-yielding modulus. These proposed ANFIS models show reliable increased accuracy in predicting constitutive properties of concrete retrofitted by FRP, compared to the constitutive models suggested by other researchers.