• Title/Summary/Keyword: 복합단열

Search Result 128, Processing Time 0.028 seconds

Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes (단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향)

  • HyungYong Ji;Dong-Yeol Chung;Seuk Cheun Choi;Joeng-Yeol Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • An optimized design of the transportation insulated box must be considered to control the thermal damage in order to maintain the fresh condition for temperature-sensitive medicine and frozen food safety. The inside temperature of the insulated box is a natural convection enclosure state, thermal stratification naturally occurs as time passes in case of with outside heat load. The latent heat material (LHM) placement inside the box maintains the target temperature of the product for temperature fluctuations during transport, and LHM application is a common and efficient method. In this work, inside temperature stratification in an insulated box depending on the LHM pack position is numerically simulated and experimented. The insulated box is made up of vacuum insulation panel (VIP), and LHM modules are placed over six faces inside the box, with the same weight. The temperature curves for 72 hrs as experiment results clearly show the temperature stratification in the upper, middle, and lower at the LHM melting time region. However, the temperature stratification state is uniformly changed in accordance with the condition of the upper and lower placement weight of the LHM pack. And also, the temperature uniformity by changed placement weight of LHM has an effect on maintaining time for target air temperature inside the box. These results provide information on the optimized design of the insulated box with LHM.

Insulation Performance Evaluation of the Curtain Wall Anchoring Unit by 3D Heat Transfer Simulation and Life Cycle Cost Analysis (3차원 전열해석 및 생애비용 분석을 통한 커튼월 앵커링 유닛의 단열성능 향상 방안 평가)

  • Kang, Seung-Hee;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.63-70
    • /
    • 2003
  • It is very important to improve the insulation performance of curtain wall anchoring unit since it is composed of materials with high thermal conductivity, such as aluminium, steel and so on. This study aims to evaluate the heating energy performance and economical efficiency of various alternatives which are different in position and material of insulation. As results, alternative of inserting the urethane washer & pad and coating the anchoring unit with urethane foam can improve the heating energy performance and L.C.C(Life Cycle Cost) by 6.33% and 0.95%, respectively, as compared with the existing case.

카본 페놀 복합재료의 내열특성 연구(I)

  • Lee, Hyung-Sik;Jung, Sam-Tae;Yoon, Nam-Gyun;Ye, Byung-Han;Jung, Bal
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.23-29
    • /
    • 1995
  • Fafbric 4종, 수지2종과 상용화된 프리프레그 2종에 대한 내열특성에 관하여 비교 연구 하였다. Fabric의 특성은 알려진 바와 같이 PAN계 카본 fabric의 경우 내삭마성은 우수하나 단열성능이 떨어지고, Rayon계의 경우는 그 반대이다. 공정성면에서는 rayon spun yarn으로 제직한 경우가 가장 우수한 것으로 나타났다. Spun PAM으로 제직한 경우는 직조후 탄화공정을 채택함으로써. 노즐재료로서 PAN계 탄소섬유의 사용을 가능하게 하였지만 즉 공정성은 좋으나 단열성 및 내삭마성 모두가 떨어졌다. F940수지의 경우는 SC1008과 페놀수지의 화학적특성은 다소 차이가 있으나 물리적특성이나 열적특성은 거의 유사한 것으로 나타났다. 프리프레그의 제조는 각수지와 Fabric의 조건에 맞게 R/C, V/C를 조정하여 코팅하였다. 토오치 테스트등 결과들을 종합해보면 전체적인 노즐재료로서의 성능은 아직은 Rayon계 카본이 우수한것으로 판단할수 있으나, 보다 정확한 평가를 위해서는 실제 노즐 테스트가 필요하다.

  • PDF

Deflection Characteristics of Permanent Formwork Using Multi-layer Insulation (다층형 단열재를 사용한 영구거푸집의 처짐 특성)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.130-131
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. In addition, the conventional styrofoam insulating material has a problem that the thickness of the heat insulating material to achieve a standard heat permeability is rapidly increased. Due to the thick insulation, there is a high risk of spreading vulnerable structures such as fire due to lack of space between buildings. On the other hand, the method of using the insulation as a formwork is known to be excellent cost saving effect through the reduction of the formwork usage and the simplification of the external insulation work. In order to solve this problem, this study aims to fabricate a multi-layered insulator that combines high-performance phenolic foam insulation and styrofoam insulation and evaluate the deflection characteristics for use as formwork.

  • PDF

Relation Between Fracture Frequency and Hydraulic Characteristics of Granite in Busan Area (부산지역 화강암의 단열빈도와 수리적 특성의 상관성)

  • 함세영;김문수;류상민;이병대;옥수석
    • The Journal of Engineering Geology
    • /
    • v.11 no.3
    • /
    • pp.279-294
    • /
    • 2001
  • When constructing subsurface structures and drilling wells, the precise hydraulic parameters must be obtained for operating safety and for developing enough quantity of groundwater, respectively. In this study we conducted water injection test at different depths on six boreholes drilled in the granite of Mt. Geumjeong. Hydraulic conductivity was calculated using Moye and Hvorslev methods. The relation between hydraulic conductivity and fracture frequency data obtained from acoustic televiewer and core log was analyzed. From the result, though the correlation coefficient between the hydraulic conductivity and the fracture frequency from acoustic televiewer data is higher than that between the hydraulic conductivity and the fracture frequency from core log data on most of the test holes, the correlation coefficient between the hydraulic conductivity and the fracture frequency from the televiewer data is lower than 0.5. This suggests that the hydraulic conductivity of granite in the study area is influenced not only by the fracture frequency but also by various factors of fracture network such as fracture aperture and length, interconnectivity of fractures, fracture orientation and angle, filling material and so on.

  • PDF

A Study on the Environmental Effects of the Carbon Composite /Insulation Rubber Interfaces (탄소계 복합재와 내열 고무 경계면의 환경 노화에 따른 특성 연구)

  • 윤영주;박병열;박현목;정상기
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.34-34
    • /
    • 1998
  • 일반 항공기 및 상용 복합 구조재의 경우에는 내부에 결함이 생길 경우 유지 및 보수가 용이하나 복합재 압력 용기의 경우에는 다양한 환경 변화를 겪게 되며 또한 유지 및 보수가 힘들다는 제약 조건이 있으므로 단열재로 사용되는 인슈레이션 고무와 FRP간의 접착, 가황 고무와 미가황 고무 사이의 접착 등 여러 가지 이종 재질들 간의 접착이 매우 중요한 변수가 될 뿐만 아니라 압력 용기의 전체적인 성능에도 상당한 영향을 미치게 된다. 이러한 시스템들은 제작 조건에 따라 결함이 발생하는 빈도가 차이가 나며 특히 가혹한 환경 조건하에서도 내구성을 보여야 하므로 본 실험에서는 다양한 환경 조건, 성형 조건을 가지는 FRP/고무, 고무/고무 접착 시스템의 계면 접착력을 측정한 후 이로부터 환경 노화에 저항성이 강한 최적의 접착제 및 접착 조건 등을 확립하고자 하였다.

  • PDF

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

Silica Aerogel Blanket Processing Technologies for Use as a Widespread Thermal Insulation Material (범용 단열재로 활용하기 위한 실리카 에어로젤 블랭킷의 처리 기술)

  • Jae-Wook Choi;Young Su Cho;Dong Jin Suh
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.237-243
    • /
    • 2023
  • Aerogel is the most excellent insulation material known to date, but it is inflexible and has very low strength. A blanket containing aerogel in a nonwoven fabric or fiber is currently the most practical form. However, aerogel blankets are not yet widely used because they cannot avoid dust generation when handled, lack flexibility, and can possibly deform. In this study, vacuum treatment, surface treatment, and composite materialization technology were applied to solve this problem, and some prototypes were also made. If an aerogel blanket is wrapped in an aluminum sheet, sealed at the four ends, and vacuumed, it can become a material with better insulation than the blanket itself. An aerogel molded body can be made by coating the aerogel blanket with resin and treating the surface. If the aerogel blanket is multi-packed and laminated with resin or fiber in multiple layers to make it a composite material, it can be used as a flexible insulation material. In particular, this composite material, which utilizes a Teflon membrane with controlled pores, is breathable and waterproof, so it can be used for clothing. Prototypes of insoles for winter boots and outdoor roll mats were also produced using aerogel blanket resin and fiber composites. These prototypes showed low thermal conductivity of less than 20 mW m-1K-1, with good flexibility and durability.

A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion (압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구)

  • Jung, Yun Jin;Kwon, Young Bong;Kwak, Myong Keun;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.543-551
    • /
    • 2006
  • Cold-formed steel studs that are being used as load-bearing members of wall panels for steel houses have a problem with their insulation due to the heat bridging of their web. Some additional thermal insulating materials should be used. To solve this problem, the new-concept hybrid stud, which consists of a galvanized steel sheet (t = 1.0 m - 12.0 m) and a GFRP panel (t = 4.0-6.0 mm), has recently been developed. An investigation on the structural behavior and the strength capacity of this new hybrid stud has been conducted so that it can be used in load-bearing wall panels of residential buildings. This paper describes the axial compression-torsion test results of the hybrid studs under both axial compression and torsion using ATTM. The main factors of the test were the stud length, the magnitude of the initial compressive force, and the loading method of the monotonic or cyclic loading. The torsion was applied increasingly while the initial compression was kept constant to the failure of the hybrid section. The advanced analysis results obtained form the finite element procedure that considered the material properties of the high-strength galvanized steel and the GFRP were compared with the test results for verification.

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.