• Title/Summary/Keyword: 복수열

Search Result 91, Processing Time 0.033 seconds

DUI DUO SHU in LEE SANG HYUK's IKSAN and DOUBLE SEQUENCES of PARTIAL SUMS (이상혁(李尙爀)(익산(翼算))의 퇴타술과 부분합 복수열)

  • Han, Yong-Hyeon
    • Journal for History of Mathematics
    • /
    • v.20 no.3
    • /
    • pp.1-16
    • /
    • 2007
  • In order to generalize theory of series in Iksan(翼算), we introduce a concept of double sequence of partial sums and elementary double sequence of partial sums, which play a dominant role in the study of double sequences of partial sums. We introduce a concept of finitely generated double sequence of partial sums and find a necessary and sufficient condition for those double sequences. Finally we prove a multiplication theorem for tetrahedral numbers and for 4 dimensional tetrahedral numbers.

  • PDF

Three Dimensional CFD Analysis for the Condenser of the Fossile Power Plant (화력발전소 복수기 3차원 열유동 모사)

  • 이진욱;민동호;김범신
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.601-604
    • /
    • 2003
  • 본 연구의 목표는 현재 복수기의 운전상황을 반영한 열유동 해석을 수행하여 저압터빈후드 온도의 좌우 편차가 발생하는 원인을 분석하는 것이다. 그러나 실제 복수기가 기하학적 형상이 복잡하고, 운전조건의 명확한 설정이 어려우며, 또한 수치해석에도 포함되는 오차 등을 고려하면, 단순히 현재의 운전조건 만을 반영한 해석에 의하여서는 원인의 규명이 어렵게 된다.(중략)

  • PDF

영광1호기 원자로 냉각재 평균 온도 조정에 따른 터빈 사이클 열성능 변화 분석

  • Choi, Kwang-Hui;Hong, Seung-Yeol;Park, Bu-Seong;Kim, Yu
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.532-537
    • /
    • 1996
  • 영광 1호기의 일차계통인 원자로 냉각재 평균온도( $T_{avg}$)를 적정값으로 미세조정하여 운전할 때, 2차계통 주요 운전변수인 주증기압력이 상승하고 터빈출력이 상승함을 발견하여 이에 대한 터빈사이클 열성능 변화를 발전소 전체 열평형 계산에 의해 정량적으로 파악하고, 그 원인을 열역학 2법칙에서의 엔트로피개념을 이용한 유용에너지의 최대값인 엑서지이론을 적용하여 분석하고자하였다. 분석 결과 열평형 계산에서는 전체 열량의 대부분인 63.2%가 복수기에서 손실되는 것으로 나타나는 반면, 열역학 제2법칙의 엑서지를 이용한 분석에서는 비가역손실이 주로 터빈(전체 엑서지의 12.7%)에서 일어나고 그 다음이 복수기(5.7%), 급수가열기(2.1%) 그리고 1,2단 재열기 (1.0%)의 순으로 전체 사이클에서 일어나며, 주증기 압력이 상승할 때 터빈 출력이 상승하는 주원인은 주증기의 유용성(엑서지)이 크게 증가하는 것에 비해 터빈사이클에서의 비가역손실은 적게 증가하기 때문으로 나타났다.다.

  • PDF

Multi-view content for Digital Broadcasting (디지털 방송 환경에서 복수시점 콘텐츠의 설계 및 구현)

  • Ahn, Byoung-Kyu;Jung, Moon-Ryul;Kim, Wook-Joong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.213-217
    • /
    • 2005
  • 본 논문에서는 DVB-MHP 방송규약의 범위 내에서 복수시점 콘텐츠를 제작하고 구현하는 데 필요한 방법을 기술한다. 복수시점 콘텐츠는 파노라마 정지영상과 다시점 비디오 영상 등을 Java Xlet 을 통해서 TV 화면 상에서 적절한 시간에 나타나게 한다. 이것은 기존의 방송 콘텐츠와는 달리 시청자에게 보다 다양한 시점들을 제공하고 몰입감을 향상시킬 수 있는 장점이 있다. 또한 이러한 복수시점 콘텐츠를 쉽게 구현할 수 있도록 하기위해, 기존 방송 규약에 정의되지 않은 새로운 API 를 제안한다.

  • PDF

Inhibition of Con A-induced Iymphocyte proliferation by peritoneal exudate of Toxoplasma gondii-infected mice (톡소포자충 감염 마우스 복수액에 의한 Con A 유도 림프구 증식 억제효과)

  • 남호우;최원영
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.3
    • /
    • pp.195-200
    • /
    • 1995
  • The presence of biological response modifiers (BRMI-like effect was confirmed in peritoneal exudate (PE) of ToxopLnsmo gondii-infected ICR mice which inhibited Concanavalin A (Con A)-induced peritoneal Iymphocyte (PL) proliferation. During 5 days of PL incubation with $10{\;}\mu\textrm{g}/ml$ Con A with or without PE, 3H-thymidine uptake was measured for the last 24 hrs. Compared to uninduced control, PL proliferated by 7.3-fold with Con A induction_ When PE of infected mice was added, PL proliferation was inhibited by $74.0{\;}{\pm}{\;}11.9%$ whereas inhibition by PE of normal mice was $16.4{\;}{\pm}8.3%$. Inhibitory effect of PE increased exponentially from 3 days up to 4-5 days of survival after the infection. Inhibitory activity of PE was decreased concentration-dependently. Also the inhibition was diminished when the PE was treated with heat of $95^{\circ}C$ for 10 min orprecipitated with 10% trichloroacetic acid (TCA). In SDS-PAGE of PE, many minor bands appeared newly. Heat-labile protein molecule in PE exerted inhibitory activity to Con A- induced Iymphocyte proliferation.

  • PDF

Decreasing the Turbine Power Based on the Number of Circulation Water Pumps in Nuclear Power Plants (순환수펌프의 작동수를 고려한 원전터빈 출력조정)

  • 진수환;명효형;진명길;김성준
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.240-247
    • /
    • 2002
  • 복수기의 원활한 열교환에 필요한 냉각수를 공급하기 위해 순환수펌프는 해수를 끌어들이는 역할을 한다. 각종 해양생물이나 이물질 등으로 인해 순환수펌프의 작동이 멈추는 경우가 간헐적으로 발생하고 있는 데, 이렇게 되면 복수기 튜브 쪽으로 유입되는 순환수 유량은 정상상태보다 줄어들게 된다. 이를 무시하고 원전터빈을 계속 고출력으로 가동시키면 복수기 내부의 전공도가 악화되어 작동이 정지되는 상황을 맞을 수 있으므로 터빈출력을 적정한 수준으로 낮추는 작업이 필요하다. 본 연구는 순환수펌프의 작동수 및 해수온도를 고려하여 터빈의 적정출력을 산정하고 이를 도표화하여 제시하였다. 분석결과를 기존의 운전데이터와 비교검토한 결과 대체로 일치하고 있어 운전조건을 안정적으로 유지하는 데 도움이 될 전망이다.

  • PDF

Phylogenetic study of the section Adonanthe of genus Adonis L. (Ranunculaceae) based on ITS sequences (ITS 염기서열에 의한 복수초속 복수초절(미나리아재비과)의 계통분류학적 연구)

  • Son, Dong Chan;Park, Beom Kyun;Ko, Sung Chul
    • Korean Journal of Plant Taxonomy
    • /
    • v.46 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • DNA sequences of nrITS regions obtained from 49 accessions representing 12 species and one variety within the section Adonanthe of the genus Adonis were analyzed to test the previous intra-sectional classification system and to determine their phylogenetic relationships. The results showed that the seven accessions of A. amurensis Regel et Radde included in the present study did not form a monophyletic group, as some of the accessions showed a close relationship with the Japanese endemic species A. ramosa Franch., which implies that the current species delimitation and identification of A. amurensis is problematic. Adonis pseudoamurensis W. T. Wang, which is frequently misidentified as A. ramosa in Korea, formed a segregated group, which suggests that they should not be considered as conspecific taxa. Accessions from A. shikokuensis Nishikawa et Koji Ito, A. multiflora Nishikawa et Koji Ito, and A. pseudoamurensis formed a clade, but monophyly of each species was not evident. The nrITS data did not support the classification system proposed by Wang, who classified sect. Adonanthe into four series, as most of these were found to be either polyphyletic or paraphyletic.

An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System (지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구)

  • Lim, Hyo-Jae;Kwon, Jeong-Tae;Kim, Chang-Eob;Kong, Hyoung-Jin;Park, Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

Feasibility Study on Modified OTEC (Ocean Thermal Energy Conversion) by Plant Condenser Heat Recovery (발전소 복수기 배열회수 해양온도차 발전설비 적용타당성 검토)

  • Jung, Hoon;Kim, Kyung-Yol;Heo, Gyun-Young
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.22-29
    • /
    • 2010
  • The concept of Ocean Thermal Energy Conversion (OTEC) is simple and various types of OTEC have been proposed and tried. However the location of OTEC is limited because OTEC requires $20^{\circ}C$ of temperature difference as a minimum, so most of OTEC plants were constructed and experimented in tropical oceans. To solve this we proposed the modified OTEC which uses condenser discharged thermal energy of existing fossil or nuclear power plants. We call this system CTEC (Condenser Thermal Energy Conversion) as this system directly uses $32^{\circ}C$ partially saturated steam in condenser instead of $20{\sim}25^{\circ}C$ surface sea water as heat source. Increased temperature difference can improve thermal efficiency of Rankine cycle, but CTEC should be located near existing plant condenser and the length of cold water pipe between CTEC and deep cold sea water also increase. So friction loss also increases. Calculated result shows the change of efficiency, pumping power, net power and other parameters of modeled 7.9 MW CTEC at given condition. The calculated efficiency of CTEC is little larger than that of typical OTEC as expected. By proper location and optimization, CTEC could be considered another competitive renewable energy system.