• Title/Summary/Keyword: 복사기

Search Result 558, Processing Time 0.021 seconds

A Study of Ozone Occurrence Amount by Copy Machine Use in School and Around of School (학교 내.외 복사기 사용에 따른 오존 발생량 연구)

  • Noh Sun-Jin;Jung Kyung-Sick;Seo Seung-Pyo;Son Bu-Soon;Lee Jong-Wha;Lee Che-Won
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.58-65
    • /
    • 2006
  • This study is measured in at ozone concentrated places in school and outside of school where places that use copy machine and the others do not use one. Library copy room, Search room, Y-Copy, J-copy, R-shop are the places using copy machines and Search room, K-apt, J-billiard hall are the opposite. The measurement was held three times a day-the morning, the afternoon and the evening-once for each at indoor and outdoor. 8 places were lower than domestic ozone concentration standard(0.06ppm). The indoor ozone concentration average was the highest in Search room of school and was the lowest in Library restroom. The outdoor ozone concentration average was the highest in J-billiard hall.

Effects of Surface Roughness on Evaporation Cooling of Single Water Droplet in Radiative Fields (복사장 내에서 충돌면의 표면조도가 단일액적 증발냉각에 미치는 영향)

  • 유갑종;박철우;장충선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.467-474
    • /
    • 2004
  • This paper presents the results of an experimental investigation for the effect of radiant heat on the evaporation cooling of water droplet in the process of fire extinguishing. The experiments are mainly focused on the surface temperature, the surface roughness and the droplet diameter. The range of surface temperature is T$_{s}$ =80-14$0^{\circ}C$, surface roughness is R$_{a}$=0.08-0.64 ${\mu}{\textrm}{m}$ and the droplet diameter is $\Phi$=3.0 mm in the radiation. The results show that the evaporation time is shorter for the larger surface roughness and the volume of droplet increased when the surface roughness is 0.64 ${\mu}{\textrm}{m}$ at the surface temperature 127$^{\circ}C$. When the surface roughness is 0.64 ${\mu}{\textrm}{m}$, the heat flux is larger than the surface roughness is 0.08 ${\mu}{\textrm}{m}$ at the surface temperature 81$^{\circ}C$.>.>.

Development Trend of Japanese Optical Payloads (일본의 광학탑재체(지상/해양 관측용) 개발 경향)

  • Myung, Hwan-Chun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.65-75
    • /
    • 2010
  • In 2014, Japan is scheduled to launch GCOM(Global Change Observation Mission)-C for the global change observation mission, where SGLI(Second-generation Global Imager) is planned for optical multi-channel observation ofa radiation budget and a carbon cycle. Depending on the spectral channels, SGLI consists ofS GLI-VNR(Visible Near IR) and SGLI-IRS(IR Scanning). Their main design schemes are mostly based upon those ofthe previous instruments ever developed in Japan, which is intended to reduce the development risk for the advanced performance. Accordingly, for the better understanding ofSG LI, the paper reviews the history oft he Japanese optical payloads from two different views: VNR and IR. Through the review, a comparison among the Japanese optical instruments is made to distinguish the development trend toward SGLI ofGC OM-C.

  • PDF

Design of Dipole Array Antennas for PCS/IMT-2000 (PCS/IMT-2000을 위한 다이폴 배열 안테나의 설계)

  • 최학윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.873-881
    • /
    • 2002
  • In this paper, the rectangular reflector antenna with 8-dipole array for PCS band (1,750 MHz ~ l,870 MHz) and IMT-2000 band(1,885 MHz ~ 2,200 MHz) is designed and the radiation characteristics are analyzed using the method of moments and HFSS(High Frequency Structure Simulator). To verify the analysis results, rectangular reflector antenna with 8-dipole array is fabricated and the calculated results are compared with the measured results. The measured results show good agreement with the calculated results. As a result of measurements, bandwidth(VSWR< 1.5) of 450 MHz is achieved at PCS and IMT-2000 band and gain is 16 dBi. The designed antenna can be used as the base station antenna for PCS/IMT-2000.

A Case Study on the Plumbing Pipe Burst of Floor Radiant Heating (바닥 복사난방 배관설비에서 배관파열 사례 연구)

  • Jung, Hong-Do;Shin, Youn-Han;Park, Chen-Kwan;Jeong, Hyo-Min;Chung, Han-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.745-749
    • /
    • 2012
  • Heating pipes burst was occurred in the apartment complex that was applied floor radiant heating system. There were two opinions for the cause of the bursted heating pipes that was the flaw during construction and defects in the product and also there were conflicting among them. Officials analyzed it in order to investigate the cause of the rupture. Tensile test results showed different tensile strength between the lower part of heating pipe and the upper part of heating pipes. The lower tensile strength is maintained while the top was not secured. The reason why rupture heating pipes is that flow velocity isn't secured and then the air get stagnant. Stagnant air makes hardening. It is caused rupturing. The proper flow rate was confirmed 0.166 m/sec after experiment. It isn't make stagnant air inside heating pipes.

An Analytic Solution of a Circular Aperture Antenna with a Feed Transition (급전부에 전이 구조가 있는 원형 개구면 안테나의 엄밀한 해석 방법)

  • Lee Haeng-Seon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.982-988
    • /
    • 2005
  • An analytic solution of circular aperture antenna with a feed transition is presented using a hybrid method of generalized scattering matrices and integral transform. The method can give an analytic solution to antennas with integrated filters or mode converters, etc. Scattering matrices and integral transform techniques are combined to accommodate discontinuities connected between an aperture and a feed waveguide, and radiated field from the aperture. The method gives radiation fields as well as return losses of the antenna.

Prediction of Sublimation Drying Time for Carrot in Freeze-Drying (당근의 동결건조에서 승화건조시간 예측연구)

  • Park, Noh-Hyun;Kim, Byung-Sam;Bae, Sin-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.313-320
    • /
    • 1993
  • A sublimation model of the freeze drying process, which accounted for the removal of free water, was presented and used to study the operation conditions of freeze driers for carrot juice. It was found that the shortest drying time was obtained when the condenser temperature and chamber pressure were kept at heir lowest values and the plate temperature was controlled independently so that the scorch and melting constraints were both held throughout the drying period. The effect of sample thickness on the drying time was significant. Optimal policies were investigated experimentally in laboratory freeze dryer.

  • PDF

Design and Fabrication of the GPS Receiving Antenna using Hilbert Curve Fractal Structure (힐버트 커브 프랙탈 구조를 이용한 GPS 수신 안테나 설계 및 제작)

  • Kang, Sang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.125-129
    • /
    • 2014
  • In this paper, design and fabrication of the GPS receiving antenna using Hilbert curve fractal structure was proposed. The size of the antenna was miniaturized by transforming dipole structure into monopole structure because its size increases if Hilbert curve fractal dipole structure is used. To use a Hilbert curve structure, the current directions of the radiator were made oppositely each other. The size of the antenna is $10{\times}10{\times}0.8[mm]$, the line width is 0.25[mm]. The resonant frequency is 1.58[GHz] and its range is 1.52[GHz] ~ 1.65[GHz]. Frequency bandwidth is 130[MHz]. Antenna maximum gain is 3.09[dBi].

MIRIS 우주관측 카메라 Noise Test

  • Park, Yeong-Sik;Lee, Dae-Hui;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Nam, Uk-Won;Park, Jang-Hyeon;Lee, Seung-U;Matsumoto, Toshio;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.126.2-126.2
    • /
    • 2011
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 2012년 하반기 발사예정이다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. x 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. 현재 MIRIS는 비행모델 개발 마무리 단계에 있으며, 검교정 시험, 열-진공 시험, 진동 시험 등을 수행하고 나면 2011년 말 위성 본체와의 조립을 진행할 것이다. 망원경이 복사냉각(Passive Cooling)을 통해 200K 이하로 냉각되면, dewar에 설치된 소형 냉각기를 가동하여 적외선 센서를 90K 정도로 냉각한다. MIRIS 우주관측카메라에는 PICNIC($256{\times}256$ pixel) 센서를 사용하였고, 상온과 냉각된 상태에서의 노이즈 특성을 측정하였다. PICNIC 센서와 dewar내부를 냉각하기 위해 RICOR사의 K-508 micro stirling cooler를 사용하는데, cooler가 동작하면서 전자부에 영향을 주어 주된 잡음으로 나타남을 확인하였다. Cooler에서 발생하는 잡음을 최소화 하기위해 fanout B/D와 LVPS 부분을 개선하였으며, 본 발표에서는 잡음 측정 결과에 대해 논의 하고자 한다.

  • PDF

An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber (복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극)

  • Kim, Young-Min;Park, Seong-Je;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF