• Title/Summary/Keyword: 복사강도

Search Result 88, Processing Time 0.02 seconds

Analysis on Infrared Stealth Performance with Emissivity Controlled Aircraft Surface Structure at Various Background (항공기 적외선 스텔스 기술 적용을 위한 다양한 배경조건에서의 방사율 제어구조 성능 분석)

  • Bae, Munjang;Kim, Taehwan;Kim, Taeil;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.455-461
    • /
    • 2016
  • Survivability of an aircraft has been greatly threatened by the development of a weapon system using infrared. Therefore, the infrared stealth technology is a very important technique to improve the survivability of an aircraft. In this study, the infrared signal of an aircraft was analyzed which corresponding to the aircraft surface temperature and environmental conditions with various surface conditions(especially emissivity changed). Based on the analyzed infrared signal, the optimized surface emissivity was suggested to reduce the average contrast radiance and contrast radiant intensity(CRI). In addition, we confirmed that the infrared contrast radiant intensity between the aircraft and the background can be minimized through an appropriately controlled surface emissivity of the aircraft at specific background.

Infrared Signature Analysis on Armored Vehicle Applied with Emissivity Controlled Structure (장갑 차량의 방사율 제어구조 적용에 따른 적외선 신호 분석)

  • Kim, Taeil;Kim, Taehwan;Bae, Ji-Yeul;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2017
  • Due to rapid development of infrared guided weapon, survivability of armored vehicle is severely threatened. Hence, reduction of susceptibility by lowering infrared signature level is essential to enhance survivability of the vehicle. For this purpose, numerical analysis is conducted to analyze time and spatial characteristics of infrared signature of the vehicle when surface emissivity changes in this study. The analysis shows that the emissivity which produces minimum contrast radiant intensity is significantly altered by time and detecting position. Based on the result, it is concluded that the controlled structures which have different emissivity should be adopted at different region of the vehicle to effectively decrease infrared signature level.

Changes of Physical and Mechanical Properties of Firefighter Protective Clothing After Radiant Heat Exposure (노출시간과 열강도에 따른 복사열 노출후의 소방보호복의 물리적 특성과 역학적 특성변화)

  • ;N.Pan;G.Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.853-863
    • /
    • 1999
  • the change of physical properties (thickness, weight, air permeability) and mechanical properties(abrasion resistance breaking load and displacement) of samples were determined after heat exposure by a RPP tester. The effect of exposure time and heat flux intensity on the changes and the relationship between physical properties and mechanical properties were investigated. FR treated cotton Kevlar/PBI and Nomex with different structureal characteristics were chosen for specimens. The changes of physical properties and mechanical properties were calculated based on their initial values before heat exposure. The longer exposure time and the high heat flux intensity the more changes of those properties. Heat flux intensity was more effective on the changes, The showed to be affected by an interplay of shrinkage and pyrolysis products loss. The changes of thickness and abrasion resistance showed to be higher for plain weave fabric and those of air permeabiliyt and breaking load and displacement for twill weave fabric. While FR treated cotton which have high RPP value experienced serious and detrimental changes after heat exposure Kevlar/PBI which has low RPP value showed no high changes. In conclusion it could be confirmed that when total performance of a protective clothing is estimated retention capability of physical and mechanical properties after heat exposure as well as RPP value must be considered.

  • PDF

Carbon Monoxide Emission and Radiation Properties in Ceramic Fiber Radiant Burner (세라믹 화이버 버너의 CO 배출과 복사강도 특성)

  • Jeong, Yong-Ki;Kim, Young-Soo;Lee, Dae-Rae;Yang, Dae-Bong;Ryu, Jung-Wan;Yun, Alexander;Chang, Young-June;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.176-183
    • /
    • 2007
  • An experimental study was performed to investigate the effects of mixing quality, inlet pressure, nozzle diameter on CO emission and radiation characteristics in porous ceramic fiber radiant burners. Observations of combustion characteristics occurring inside the burner system which was insulated fiber mat, were investigated by measuring temperature, CO emission and radiation characteristics. Combustion was achieved at the firing rate of $88{\sim}99$ kcal/hr, inlet pressure of $100{\sim}250$mm$H_2O$. CO emissions were found to be strongly dependent on the operating conditions. There was a tendency that CO concentration increased as the firing rate increases. The reason for rise of CO concentration is that it becomes the relatively rich condition. The fiber burner exhibit significant both spectral intensity peaks in the bands at 2.5${\mu}m$ and 4.0${\mu}m$ relatively, There is a small difference in the variable mixing tube. However spectral intensity increased with the firing rate.

  • PDF

Computational Studies on the Combustion and Thermal Performance of the Coal Fired Utility Boiler : Temperature and Thermal Energy Distribution (석탄화력 보일러 연소열성능 해석 : 온도와 열에너지 분포를 중심으로)

  • Seo, Sang-Il;Park, Ho-Young;Lee, Sung-No
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.157-166
    • /
    • 2009
  • The pulverized coal combustion behavior in the coal fired utility boiler has been investigated with the CFD and process analysis techniques. The used commercial software were CFX and PROATES, and these were coupled each other to get more reliable boundary condition set-up, resulting in more reliable solution. For two cases which were the actual operation condition of A power plant, the calculated values from the coupled CFD and process analysis for thermal energy system were compared with the plant data, and the good agreements were obtained for Case 1 and 2. The calculated temperature distributions on the surface of heat exchangers were compared with the plant data for the steam temperatures across heat exchangers, and these explained the actual operating situation very well. The temperature deviation across the final superheater tube, which was believed to be the main cause of the frequent tube failure, were also explained very well with the calculated distributions of gas temperature and radiation on the plane of the final superheater.

A Case Study on the Plumbing Pipe Burst of Floor Radiant Heating (바닥 복사난방 배관설비에서 배관파열 사례 연구)

  • Jung, Hong-Do;Shin, Youn-Han;Park, Chen-Kwan;Jeong, Hyo-Min;Chung, Han-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.745-749
    • /
    • 2012
  • Heating pipes burst was occurred in the apartment complex that was applied floor radiant heating system. There were two opinions for the cause of the bursted heating pipes that was the flaw during construction and defects in the product and also there were conflicting among them. Officials analyzed it in order to investigate the cause of the rupture. Tensile test results showed different tensile strength between the lower part of heating pipe and the upper part of heating pipes. The lower tensile strength is maintained while the top was not secured. The reason why rupture heating pipes is that flow velocity isn't secured and then the air get stagnant. Stagnant air makes hardening. It is caused rupturing. The proper flow rate was confirmed 0.166 m/sec after experiment. It isn't make stagnant air inside heating pipes.

Measurement of Radiation Intensity of the High-Pressure and Large-Current Arc (고압 대전류 아크의 복사강도 측정)

  • Song, Ki-Dong;Oh, Yeon-Ho;Chong, Jin-Kyo;Cho, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.11
    • /
    • pp.555-563
    • /
    • 2006
  • This paper presents the measured radiation intensity of high-pressure and large-current arc with the current. In order to measure the radiation intensity of large-current arc, a model circuit breaker was specially designed and manufactured and the method using an astronomical telescope was utilized after various measuring methods were investigated. A trigger system was designed and fabricated to coincide the time of desired current with the exposure time of 1ms of the spectroscope. A high-speed camera was used to investigate the shape and behavior of the arc and the captured results have been used to calculate the radiation energy. The calculated arc temperature with Boltzmann plot method using the measured radiation intensity have $18,000{\sim}27,000K$ to the current $4kA{\sim}15kA$. And also, using the calculated arc temperature and the captured arc shape the radiation energy of the current $5kA{\sim}15kA$ were calculated with $8{\times}10^5{\sim}4.0{\times}10^6W/m$ respectively.

Characteristics of LED Signal Lamp Driving by SMPS for Large-scale Traffic Signal (SMPS 구동 대형교통 신호용 LED 신호등의 특성)

  • Shin, Hyun-Yong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.643-648
    • /
    • 2011
  • In this study, SMPS driven LED traffic signal light for Large-scale traffic such as railroad and airport was designed and its electrical and EMI characteristics were measured. The output current of the LED module driven by SMPS was 1.67A for AC and DC input voltage over 10V. The conducted emission measured over 0.15~30MHz frequency range was lower than the allowed quasi-peak and average level, and the radiated noise measured over 30~1000MHz frequency range showed $23.96dB{\mu}V/m$ at 59.96MHz.

Secure Certificates Duplication Method Among Multiple Devices Based on BLE and TCP (BLE 및 TCP 기반 다중 디바이스 간 안전한 인증서 복사 방법)

  • Jo, Sung-Hwan;Han, Gi-Tae
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 2018
  • A certificate is a means to certify users by conducting the identification of the users, the prevention of forgery and alteration, and non-repudiation. Most people use an accredited certificate when they perform a task using online banking, and it is often used for the purpose of proving one's identity in issuing various certificates and making electronic payments in addition to online banking. At this time, the issued certificate exists in a file form on the disk, and it is possible to use the certificate issued in an existing device in a new device only if one copies it from the existing device. However, most certificate duplication methods are a method of duplication, entering an 8-16 digit verification code. This is inconvenient because one should enter the verification code and has a weakness that it is vulnerable to security issues. To solve this weakness, this study proposes a method for enhancing security certificate duplication in a multi-channel using TCP and BLE. The proposed method: 1) shares data can be mutually authenticated, using BLE Advertising data; and 2) encrypts the certificate with a symmetric key algorithm and delivers it after the certification of the device through an ECC-based electronic signature algorithm. As a result of the implementation of the proposed method in a mobile environment, it could defend against sniffing attacks, the area of security vulnerabilities in the existing methods and it was proven that it could increase security strength about $10^{41}$ times in an attempt of decoding through the method of substitution of brute force attack existing method.

Evaluation of the Radiant Heat Effects according to the Change of Wind Velocity in Forest Fire by using WFDS (WFDS를 이용한 풍속에 따른 산림화재 복사열 강도 평가)

  • Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The wildland fire intensity and scale are getting bigger owing to climate change in the world. In the case of domestic, the forest is distributed over approximately 63.7 % of country and the main facilities like a industrial facility or gas facility abuts onto it. Therefore there is potential that the wildland fire is developed to a large-scale disaster. In this study, the effect distances of the radiant heat flux from the crown fire are analysed according to the change of wind velocity. The safety criteria concerning the radiant heat flux to influence on the surrounding were researched to analyse the effect distances. The criteria of radiant heat flux were chosen $5kW/m^2$, $12.5kW/m^2$, $37.5kW/m^2$. WFDS, which is an extension of NIST's Fire Dynamics Simulator, was used to consequence analysis of the forest fire. In order to apply the analysis conditions, it is researched the forest conditions that is generally distributed in domestic region. As the result, the maximum effect distances by radiant heat were showed at the horizontal and vertical direction. When the wind velocity varied from 0 to 10 m/s, the maximum effect distance increased as the wind velocity increases. Interesting point is that the maximum effect distance were shown at the wind velocity of 8 m/s. The maximum effect distance was decreased according as the fuel moisture of trees increase. This study can contribute to analyse quantitative risk about the damage effect of the surrounding facilities caused by wildland fire.