광섬유센서를 이용한 Beam-column 조인트의 하중에 따른 변위 계측 (Monitoring of Beam-Column Joint Using Optical Fiber Sensors)

  • 김기수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.595-601
    • /
    • 2003
  • For monitoring of the civil and building structure, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplicity of one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of beam-column joints of structures. We expect that the fiber optic sensors replace electrical strain gauges. The commercial electric strain gauges show good stability und dominate tile strain measurement market. However, they lack durability and long term stability for continuous monitoring of the structures. In order to apply the strain gauges, we only have to attach them to the surfaces of the structures. In this paper, we investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show nice response to the structural behavior of the joint.

  • PDF

철골보와 철근콘크리트기둥으로 구성된 내부 접합부의 극한전단강도 산정에 관한 연구 (A Study on the Ultimate Shear Strength Estimation of the Interior Joints of Steel Beam and Reinforced Concrete Column)

  • 문상훈;안재혁;박천석
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.57-62
    • /
    • 2006
  • Recent trends in the construction of building frame feature the use of composite steel concrete members. One of such system, RCS(Reinforced Concrete column and Steel beam) system, is known as a type of system to maximize the structural and economic benefits in the most efficient manner. This paper is focusing on an study of ultimate shear strength estimation of the interior beam-column joints of RCS system, with reinforced concrete column and steel beam. Current design methods as well as the majority of the previous researches for ultimate shear strength of the interior beam-column joint of RCS system are not easy to apply actual manner. There is a need to propose the rational macro models based on analytical approach. In this study, design method variables for interior beam-column joints of RCS system is studied assuming shear resistance of steel web panel, diagonal concrete strut mechanism and truss mechanism. Finally, calculated results based on the proposed design model are compared with test data.

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

Band Plate로 연결된 RC기둥-철골보 접합부의 이력거동에 관한 실험연구 (Structural Behavior of the RC Column-Steel Beam Joint with Band Plate)

  • 서수연;이원호;이리형;윤승조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.213-221
    • /
    • 2002
  • This paper presents the experimental result of Reinforced Concrete column-steel beam joint connected by Band Plates(BP). Main parameters in the test are the shape of BP and thickness of plate. Ten interior and exterior RC column-steel beam joint specimens are designed. Cyclic loads are applied to the beam end of eight specimens (four interior specimens and four exterior specimens). To evaluate the cyclic effect, monotonic loads are acted for two specimens. All specimen showed similar failure pattern such as the plate of BP get torn after the large deformation. Even though the specimen with double cross type BP has lower strength than the specimen with single cross type BP, the energy dissipation capacity of the specimen turned out high. Thus, provided the strength of joint with double cross type to be designed to have suitable strength by increasing the thickness of plate, the joint system may show higher seismic capacity.

20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험 (Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db)

  • 김호영;심혜정
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

국내 프리캐스트 콘크리트 건축구조물의 연쇄붕괴저항 성능분석 (Progressive Collapse Resistance Analysis of Precast Concrete Building Structures in Korea)

  • 김성현;강준희;황현종;최하진;강수민
    • 한국전산구조공학회논문집
    • /
    • 제34권6호
    • /
    • pp.417-426
    • /
    • 2021
  • 최근 현장작업을 최소화할 수 있는 PC(Precast Concrete) 건축공법의 적용이 급속하게 활성화되고 있다. 그러나 PC 공법은 시공 중, 특히 부재간 일체화 이전에 구조적 성능을 발휘하기 어렵고 완공 후에도 접합부의 일체성을 확보하기 어려워 연쇄붕괴에 취약하다. PC 건축물에서는 다양한 PC 부재간 접합 상세가 존재하며, 국내외 구조/시공 상세가 현격히 다르다. 그러나 국내 PC 시스템의 시스템과 상세 특성을 반영한 연쇄붕괴에 대한 연구는 매우 미비하다. 따라서, 본 연구에서는 국내에서 주로 사용하는 PC 구조시스템과 접합부 구조/시공 상세를 조사 분석하였다. 이를 기반으로 국내에서 사용되는 전형적인 PC 시스템의 유형을 설정하고 상기 PC 시스템의 연쇄붕괴방지성능을 평가하기 위하여 비선형 유한요소해석을 수행하였다. 해석결과를 바탕으로 국내에서 주로 사용된 PC 구조시스템의 연쇄붕괴방지 성능을 평가하고 구조설계시 고려사항을 제안하였다.

비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준 (Quantitative Damage Index of RC Columns with Non-seismic Details)

  • 김경민;오상훈;최광용;이정한;박병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.11-20
    • /
    • 2013
  • 5층 이하 비내진상세를 가지는 철근콘크리트 건축물의 지진시 긴급 위험도 평가를 위한 부재의 정량적 손상도 평가 기준을 제시하기 위하여 실대형 크기의 철근콘크리트 1층 1경간 골조 실험체의 정적실험을 실시하였다. 실험결과, 실험체는 기둥의 휨항복후 전단파괴에 의하여 파괴되었으며, 기둥과 접합부에 균열, 압괴 등의 손상이 발생한 반면, 보에는 균열 등의 손상이 거의 발생하지 않았다. 이와 같이 비내진상세를 가지며 휨항복후 전단파괴하는 철근콘크리트 기둥의 손상도를 5단계로 분류하고 손상단계별 한계상태를 평가하기 위한 정량적 기준으로서 지진시 상대적으로 측정이 용이한 잔류 층간변형각과 잔류 균열폭을 이용하였다. 손상한계상태의 잔류 층간변형각 및 잔류 균열폭은 실험결과에 따른 손상한계상태의 최대 층간변형각과의 관계에 의하여 결정하였으며, 한계 최대 층간변형각은 실험결과에 의한 부재의 하중-변형 관계 및 손상발생 현황을 바탕으로 결정하였다. 한계 잔류 층간변형각은 해당 최대 층간변형각에 의한 잔류 층간변형각 중의 최대값 이상이 되도록 하였으며, 한계 잔류 균열폭은 해당 최대 층간변형각에 의한 잔류 전단균열폭의 최소값 및 잔류 휨균열폭의 평균값으로 결정하였다. 한편, 본 논문을 통하여 제시한 손상한계상태의 잔류 층간변형각과 잔류 균열폭은 지진으로 동일한 부재 변형이 발생할 경우 내진설계가 실시된 부재를 대상으로 하는 국외 손상도 평가 기준에 의한 값보다 작은 것으로 나타났다.

내민길이를 고려한 $700kg/cm^2$ 고강도 콘크리트 골조의 구조적거동 (The Structural Behavior of $700kg/cm^2$ High Strength Concrete Frames Considering Extension Distances at Joints)

  • 신성우;안종문;윤영수;이승훈
    • 콘크리트학회지
    • /
    • 제6권5호
    • /
    • pp.140-148
    • /
    • 1994
  • R/C 라멘골조에 있어서 수직부재(기둥, 벽등)에 수평부재(보, 슬라브등)의 콘크리트 강도보다 1.4배가 넘는 강도의 콘크리트를 분리타설할 경우 ACI 318R-89 R10.13.1은 수직부재에 타설한 콘크리트가 수평부재로 2ft(60cm)이상의 내민길이를 확보하도록 규정하고 있다. 이에 따라 본 연구는 이규정을 그대로 적용하기에 앞서 실험적인 검증을 통한 구조적인 안전성을 확보하기 위하여 고강도 콘크리트 내민길이, 콘크리트 압축강도 등을 주요변수로 하여 총 6개의 실험체를 제작하여 실험 및 분석하였다. 실험결과 압축강도 및 내민 길이의 증가에 따라 각 실험체의 연성능력은 증가하는 것으로 나타났으며 R/C 라멘골조에 고강도 콘크리트와 보통강도 콘크리트를 분리타설할 경우 균열발생상황, 접합부에서의 거동 등을 고려할 때 고강도 콘크리트의 내민길이는 2h(h=보의 전체춤) 정도를 확보하여야 할 것으로 보여진다.

휨항복 후 부착파괴하는 철근콘크리트 부재의 부착 연성 평가 (Evaluation for Deformability of RC Members Failing in Bond after Flexural Yielding)

  • 최한별;이정윤
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.259-266
    • /
    • 2012
  • 일반적인 내진 설계에서는 구조물의 연성적인 거동을 유도하기 위해서 보-기둥 접합부에 인접한 보에 소성힌지가 발생하도록 한다. 따라서 철근콘크리트 부재의 부착강도와 전단강도가 휨강도보다 큰 값을 가져야 하고, 전단이나 부착파괴가 요구된 연성에 도달하기 이전에 발생하지 않아야 한다. 하지만 전단경간비가 짧은 부재의 경우에는 전단이나 부착 거동의 지배를 받는 경우가 많고, 핀칭 효과로 인해 에너지 소산이 비교적 적게 발생하므로 요구된 연성에 도달하지 못하고 파괴될 수 있다. 이 논문에서는 전단경간비가 짧은 철근콘크리트 부재의 거동 분석과 연성 예측, 특히 부착 연성 능력을 평가하기 위한 방법을 제안하였다. 이것은 반복하중에 의해 저감되는 잠재 전단강도와 잠재부착내력 모델, 그리고 소성힌지 형성에 따른 휨부착응력의 급격한 증대를 도식화하여 나타낼 수 있다. 제안된 해석법은 각 값의 변화 추이를 비교하여 부재의 거동을 파악하고, 부착 거동의 지배를 받는 부재의 경우, 부착내력과 휨부착응력의 값이 만나는 지점까지를 그 부재의 부착 연성으로 평가하는 방법이다. 이 방법은 기존에 수행된 8개의 보, 기둥 시험체를 통해 비교 및 검토하였으며 부재 거동에 대한 예측은 정확히 일치하였으나, 부착 연성 능력에 대해서는 과소평가 되었다. 그 이유는 부재의 부착강도를 실제 부착강도보다 비교적 낮게 예측한 부착강도식에서 찾을 수 있으며, 다른 부착 내력 모델에 대한 부착 연성 평가에 대한 연구가 추후 필요할 것으로 사료된다.

구조모델 개선을 위한 정보기반 하이브리드 모델링 기법 (Information-Based Hybrid Modeling Framework on the Systematic use of Artificial Neural-Networks)

  • 김준희
    • 한국전산구조공학회논문집
    • /
    • 제25권4호
    • /
    • pp.363-372
    • /
    • 2012
  • 본 논문에서는 수학적 구조 모델과 인공신경망 기법을 상호 유기적으로 결합하여 구조물의 거동 데이터로부터 부재모델 또는 재료모델의 정확도를 높이는 정보기반 하이브리드 모델 업데이트 기법을 개발하였다. 유한요소와 같은 수학적 모델을 사용하여 구조물의 거동을 모사하기 위해서는 재료, 부재, 그리고 시스템의 정확한 모델링이 우선하여야 한다. 그러나 재료, 부재의 각 레벨에서의 수학적인 모델은 이상화과정을 거치면서 중요한 특성을 생략하거나, 시스템 구성시 부재간의 상호작용이나 경계조건의 단순화로 인해 유한요소 모델은 실제 구조물의 거동과 차이를 보이게 된다. 본 논문에서 제시된 하이브리드 모델 업데이트 기법은 구조물의 거동과 수학적 모델의 해석결과 차이를 인공신경망 기법을 사용하여 보완함으로써 시스템 모델의 정확도를 높일 수 있다. 이때 시스템의 거동 데이터로부터 부재 또는 재료모델을 개선할 수 있는 데이터를 추출하여 부재 또는 재료모델을 개선한다. 제시된 기법은 보-기둥 접합부의 이력모델을 개선하는 것으로 검증하였으며, 복잡한 거동을 보이는 시스템 모델링에 광범위하게 사용될 수 있다.