• Title/Summary/Keyword: 보호피막

Search Result 59, Processing Time 0.022 seconds

A Design for Realtime Monitoring System and Data Analysis Verification TA to Improve the Manufacturing Process Using HW-SW Integrated Framework (HW-SW 통합 프레임워크를 활용한 제조공정 개선을 위한 실시간 모니터링 시스템과 데이터 분석검증 TA설계)

  • Kim, Jae Chun;Jin, Seon A;Park, Young Hee;Noh, Seong Yeo;Lee, Hyun Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.357-370
    • /
    • 2015
  • Massive data occurred in a manufacturing place is able to fulfill very important roll to improve the manufacturing process. Domestic manufacturing business has been making an multilateral effort to react the change of manufacturing circumstance, but it undergoes many difficulties due to technical weakness. Coatings is a type of paint. It protect products by forming a film layer on the products and assigns various properties to those. The research of coatings is one of the fields studied actively in the polymer industry. The importance of the coatings in various industries is more increased. However, the industry still performs a mixing process in dependence on operator's experiences. In this paper, we propose a design for realtime monitoring system and data analysis verification TA to improve the manufacturing process using HW-SW integrated framework. Analysis results from the proposed framework are able to improve the coatings formulation process by collecting more quantitative reference data for work and providing it to work place. In particular, the framework may reduce the deterioration and loss cost which are caused by absence of a standard data as a accurate formulation criteria. It also may suggest a counterplan regarding errors which can be occurred in the future by deriving a standard calibration equation from the analysis using R and Design of Experiments about an error data generated in the mixing step.

Effect of Inflammatory Responses to PLGA Films Incorporated Hesperidin: In vitro and In vivo Results (PLGA/헤스페리딘 함량별 필름에서 염증 완화 효과: In vitro, In vivo 결과)

  • Song, Jeong Eun;Shim, Cho Rok;Lee, Yujung;Ko, Hyun Ah;Yoon, Hyeon;Lee, Dongwon;Khang, Gilson
    • Polymer(Korea)
    • /
    • v.37 no.3
    • /
    • pp.323-331
    • /
    • 2013
  • Hesperidin (Hes) has known to having some functions like protection of blood circulatory system, anti-tumor effect, antioxidant effect and anti-inflammatory effect. The goal of this study is to demonstrate the relationship between Hes and inflammatory through in vitro and in vivo studies using poly(lactic-co-glycolic acid) (PLGA) film including Hes as a tissue engineered scaffold. To confirm the proliferation of cells on fabricated scaffold, cells (RAW 264.7 and NIH/3T3) were seeded on PLGA/Hes film then analyzed with MTT and SEM at 1 and 3 days after seeding. The results from ELISA, RT-PCR, and FACS for anti-oxident and anti-inflammatory effect showed that inflammatory response of PLGA/Hes film decreased more than that of PLGA film. Also, in vivo result confirmed that inflammatory response by implanted PLGA/Hes film decreased more comparing with PLGA film. This is because of anti-inflammatory effect of Hes reducing induced inflammatory cell and accumulation of fibrous capsule. The results showed that PLGA/Hes film's capacity on reducing inflammatory is better than PLGA film because of Hes.

The study on corrosion of the inner area of closed box-girder for unpainted weathering steel bridges (무도장 내후성 강 교량의 밀폐형 박스거더 내부의 부식에 대한 고찰)

  • Ma, Seung-Hwan;Noh, Young-Tai;Jang, Gun-Ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2391-2400
    • /
    • 2015
  • Weather proof steels are used for steel bridges due to its high corrosion resistance under atmospheric conditions. However, instead of forming stabilized rust layers, general rust occurs on weather proof steels under high humidity condition close to seawater or shady places. In Japan, therefore, they perform rust stabilization treatment instead of unpainted treatment due to severe atmospheric conditions. However, most of domestic weather proof steels were constructed unpainted in the form of closed box-girder, which makes the periodical repetition of dry and wet hard to occur. For the steel bridges constructed on the Han river, the evaporation of water, dew condensation due to temperature change, and stagnant water due to rain affect harmfully on the formation of passive film on weather proof steels. Thus, in this research, in order to analyze corrosion properties inside the closed box-girder for the unpainted weather proof steel bridge in the waterworks safety zone, multiple ways of analysis such as observation with eyes, cellophane-tape test, steel thickness measurement, surface corrosion potential measurement, electron microscope analysis, and X-ray diffraction analysis of the rust were performed. As a result, unstable rust layer was observed inside the closed box-girder, and severe corrosion was observed on the top and bottom of the flanges due to the effects of stagnant water caused by rain, dew condensation, and de-icing materials.

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS (EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구)

  • Yoon, Chang-Bok;Park, Jang hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.87-95
    • /
    • 2020
  • As an experimental study on the corrosion behavior of steel materials to which ATMS method using EIS was applied in concrete, immersion of Ca(OH)2 saturated aqueous solution and NaCl aqueous solution simulating the environment inside concrete The corrosion behavior was tested. The equivalent circuit was derived through the analysis of the Nyquist plot, and the interfacial resistance and the polarization resistance of the Ca(OH)2 aqueous solution were compared, and Al ATMS was the best interfacial resistance and Zn ATMS was the best polarization resistance. After burying ATMS steel material of cement mortar, the initial immersion impedance measurement value was the highest in the Zn ATMS test body in the impedance measurement by the immersion time by immersing it in the NaCl aqueous solution. Al ATMS test piece has the highest impedance and is highly reliable. This is because Al, which has a high ionization tendency, is continuously oxidized in a strong alkaline environment to form a film and protect the steel from permeation of chlorine ions.

Using ultrasound infrared thermography to detect defects in lap joint Friction stir welding (초음파 적외선 열화상을 이용한 마찰교반용접부의 결함 검출)

  • Park, Hee-Sang;Choi, Man-Young;Park, Jung-Hak;Lee, Young-Ho;Choi, Won-Young;Ko, Jun-Bin;Choi, Won-Doo
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.67-67
    • /
    • 2009
  • 알루미늄 합금 재질은 무게의 경량화와 기계적강도가 우수하며 다른 비철금속에 비하여 값이 저렴한 장점이 있다. 현재 산업현장에서 활용하는 가장 흔한 접합법으로 TIG, RSW 등과 같은 용융 용접법을 현재는 많이 사용 하고 있지만 열전도도가 높아 열 확산이 빠르고, 이에 따라 모재의 팽창이 일어나 열변형을 유발하며, 산화피막은 그 내부에 함유된 결정수가 아크용접 중 분해되어 수소를 방출함으로 기공이 발생하여 부도체로 저항용접시 전도성을 방해하는 등의 문제를 발생시킨다. 또한 철에 비해 4배정도 큰 전기전도율에 따라 저항용접시 대전류를 사용해야 하는 등의 문제점이 발생하고 있다. 이와 같은 알루미늄 합금의 용융용접 과정에서 발생하는 단점을 극복하는 기술로 고상접합 방법인 마찰교반용접법(Friction Stir Welding)이 활용되고 있다. FSW는 1991년 영국의 TWI에서 개발된 최신 용접법으로 모재를 용융점 아래에서 고상용접시키는 방법으로 용융에 따른 열변형과 흄가스(hume gas)와 스패터(spatter)를 억제시켜 주는 친환경적인 용접법이다. 이러한 마찰교반용접의 기술은 그동안 특허에 따른 로열티가 산업현장에서 사용하는데 문제가 되었으나 특허보호 기간인 20년이 1년정도의 기간밖에 남지 않은 상황에서 그 사용은 날로 증가하리라 본다. 이러한 마찰교반용접부의 결함을 평가하는 방법에는 UT, RT 등이 활용되고 있으나 얇은 박판에서의 결함검출은 용이하지 않다. 이리한 문제점을 해결하기위하여 초음파 가진을 이용한 적외선 열화상 검출 기법을 이용하여 마찰교반용접부의 결함 검출 가능성을 연구하였다. 20kHz의 주파수를 400Watt로 가진시켜 겹치기(lap joint) 마찰교반용접이된 A6061-T6의 용접부에 초음파를 입사하였을 때 발생하는 열을 적외선 열화상 카메라를 이용하여 측정함으로써 마찰교반겹치기 용접부의 결함 검출에 활용하였다. 용접부에 초음파를 입사하였을 때 부분적으로 온도차이가 발생하였고, 그에 따른 열화상을 검출 할 수 있었다. 이러한 열화상과 실제 시험편의 용접부의 강도를 평가하기 위하여 인장시험을 하였다. 그 결과 초음파 적외선 열화상 검출에서 발열부위가 나타난 부분이 인장시험에서 낮은 인장강도를 보였다.

  • PDF

Characteristics of OCP of Reinforced Concrete Using Socket-type Electrodes during Periodic Salt Damage Test (주기적 염해 시험에 따른 소켓 타입 전극을 활용한 철근 콘크리트의 OCP 특성)

  • Lee, Sang-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.28-36
    • /
    • 2021
  • It is known that buried rebars inside concrete structures are protected from corrosion due to passive layer. It is very important to delay the timing of corrosion or evaluate a detection of corrosion initiation for the purpose of cost-beneficiary service life of a structure. In this study, corrosion monitoring was performed on concrete specimens considering 3 levels of cover depth(60 mm, 45 mm, and 30 mm), W/C(water to cement) ratio(40.0%, 50.0%, and 60.0%) and chloride concentration(0.0%, 3.5%, and 7.0%). OCP(Open Circuit Potential) was measured using agar-based socket type sensors. The OCP measurement showed the consistent behavior where the potential was reduced in wet conditions and it was partially recovered in dry conditions. In the case of 30 mm of cover depth for most W/C ratio cases, the lowest OCP value was measured and rapid OCP recovery was evaluated in increasing cover depth from 30 mm to 45 mm, since cover depth was an effective protection against chloride ion ingress. As the chloride concentration increased, the effect on the cover depth tended to be more dominant than the that of W/C ratio. After additional monitoring and physical evaluation of chloride concentration after specimen dismantling, the proposed system can be improved with increasing reliability of the corrosion monitoring.

The Slow Strain Rate Dependence of Zircaloy-4 Cladding Tube in Iodine Atmosphere (I) (요드분위기에서 지르칼로이 피복재의 저변형율속도 의존성(I))

  • Choi, Y.;Kang, Y.H.;Ryu, W.S.;Rim, C.S.
    • Nuclear Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.211-215
    • /
    • 1985
  • The effects of temperature and strain rate on the I-SCC behaviors of Zircaloy-4 were investigated by constant load test at 30$0^{\circ}C$ and constant elongation rate test at 300, 350 and 40$0^{\circ}C$ in 3.34mg $I_2$/㎤. The results showed that I-SCC susceptibility increased as the strain rate decreased or the temperature increased. The empirical relation between the stress and the time to failure at 30$0^{\circ}C$ was given by 1/ $t_{f}$∝exp (0.3$\sigma$/$\sigma$$_{UTS}$-31.5) When the I-SCC susceptibility was expressed by the ratio of fracture energy in iodine atmosphere to that in the inert atmosphere, severe I-SCC susceptibility was found near 7.6$\times$10$^{-6}$ sec at 30$0^{\circ}C$ and the maximum point of I-SCC susceptibility tended to shift to the higher strain rate with increasing the temperature. The quasi-cleavage fracture was observed in I-SCC fracture surface. From these results, it was certain that the film repture step was involved as an important process in the I-SCC mechanism of Zircaloy-4.4.

  • PDF

Electron Microscopic Study on the Rabbit Inferior Lacrimal Glands (토끼 아래눈물샘의 미세구조에 관한 전자현미경적 연구)

  • Park, Young-Hee;Ahn, E-Tay;Ko, Jeong-Sik;Park, Dae-Kyoon;Kim, Myeong-Soo;Park, Kyung-Ho
    • Applied Microscopy
    • /
    • v.37 no.1
    • /
    • pp.23-33
    • /
    • 2007
  • The lacrimal gland are compound tubule-acinar glands. The main lacrimal function is the production of the aqueous layer, the thickest and major constituent of the precorneal tear film. The lacrimal gland also has an important function in the defense system of the ocular surface, forming a part of the conjunctival-associated hymphoid tissue. The ultrastructural characteristics of the lacrimal gland of the rabbit were described. The lacrimal tissues of rabbits were processed through the conventional techniques for transmission electron microscopy. The secretory portions consisted of three cell types: 1. Serous cells with electron dense secretory granules. 2. Seromucous cells containing variable moderately electron dense secretory granules with flocculent material. 3. Mucous rolls containing mucous secretory granules. The serous cells were situated at the basal portion of acini, and they contained electron dense granules of variable densities and sizes. The seromucous cells contained a few protein secretory granules and more mucous secretory granules. The mucous cells contained even fewer protein secretory granules and exclusively mucous secretory granules. The epithelium of the intralobular ducts showed secretory granules, junctional complexes, and large basolateral intercellular spaces with lateral folds. These study might be helpful in determining inter-relationships, similarities and differences among the orbital glands of various physiological or pathological conditions.