• Title/Summary/Keyword: 보행 시 사용

Search Result 229, Processing Time 0.028 seconds

Effects of the Gait Variable While Using Smartphones During Ramp Gait in Young Adults (젊은 성인에서 경사로 보행 시 스마트폰 사용이 보행 변수에 미치는 영향)

  • Yoon, Chae-Hyo;Kim, Bum-Su;Kang, Do-Young;Kim, Yeonseo;Lee, Myoung-Hee
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.261-267
    • /
    • 2021
  • Purpose: This study aimed to investigate changes in gait variables depending on whether a task was performed using a smartphone while walking on a ramp. Methods: The participants of this study were 41 college students attending U University located in Gyeongju City, Gyeongsangbuk-do. In this study, gait variables were measured during ramp gait while using a smartphone to perform a task and during ramp gait without performing such tasks. In other words, four walking conditions were used: 1) walking up a ramp, 2) walking up a ramp while using a smartphone to perform a task, 3) walking down a ramp, and 4) walking down a ramp while using a smart phone to perform a task. Gait variables were measured using a gait analysis tool (Legsys; BioSensics, USA), and stride time, stride length, stride velocity, cadence, and double support were analyzed. The order of measurements was randomized to control for order effects due to repeated measurements. Results: The comparative analysis of gait variables according to the presence or absence of smartphone use during ramp gait showed that there were significant differences in stride time, stride length, and stride velocity during both ramp ascent and ramp descent (p < 0.05). In both ramp ascent and ramp descent, stride time increased when walking using a smartphone, compared to when walking without using a smartphone (p < 0.05). However, in both ramp ascent and ramp descent, stride length and stride velocity were decreased when walking using a smartphone compared to when walking without using a smartphone (p < 0.05). Conclusion: The study results showed that the use of a smartphone during walking can affect safety. Therefore, it is necessary to improve the awareness of risks associated with walking while using a smartphone, and further research needs to be conducted in various environments and with different ramps.

An Electronic Aids for Visually Impaired People (시각장애인을 위한 보조기기 개발)

  • Cho, Hyun-Chul;Kim, Lae-Hyun;Han, Man-Chul;Park, Se-Hyung;Ha, Sung-Do
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.251-255
    • /
    • 2008
  • We have developed an electronic aids, called SmartWand, which can help visually impaired people walk safely and tell them an object's color and environmental brightness SmartWand can inform visually impaired people of the dangerous obstacles around which they can't notice by the white cane such as a large panel with supporting poles on the street. Especially we have lmproved the previous version of SmartWand by reflecting the result of user study.

  • PDF

Study on the Design Optimization to Improve Injection Molding Performance of Plastic Regulator Rail (플라스틱 레귤레이터 레일 성형 최적화연구)

  • Lee, Haeng-Soo;Byun, Hong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5709-5715
    • /
    • 2012
  • Injection molding product is commonly used for reducing the weight of automotive vehicle, and door regulator guide rail with plastic material is also made by injection molding process. In order to improve the injection molding performance of plastic regulator guide rail, optimal molding condition is suggested by numerical simulation and DOE after obtaining the sensitivity of parameters for regulator rail manufacturing on warpage and fill time. Furthermore, multi direct gate method and optimal cooling circuit are introduced to get the uniform temperature distribution and better cooling efficiency in molding product. The effect of the proposed design on the injection molding performance is verified by the test of prototype of plastic regulator guide rail.

Foot pressure analysis of laterally & medially wedged rearfoot insole in gait (보행 시 발 뒤축 내/외측 경사진 안창의 족부압력 분석)

  • Chae Byeong-Gi;Im Wan-Su;Ryu Tae-Beom;Choi Hwa-Sun;Jeong Min-Geun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.208-213
    • /
    • 2006
  • 경사진 안창은 안창의 경사로 발의 자세를 교정함으로써 하지 통증을 완화시키는 데 사용되는 보조치료기구로 내측 경사진 안창(MWI: medially wedged insole)과 외측 경사진 안창(LWI: laterlly wedged insole)으로 나뉜다. 본 연구는 내/외측 경사진 안창이 족부압력에 미치는 영향을 정량적으로 분석하고자 한다. 분석변수는 압력중심(COP: center of pressure)의 궤적 변화, 발바닥 내 세 개 구획에 상대적으로 작용하는 수직 힘(RVF: relative vertical force) 그리고 여덟 개 해부학적 지점의 압력이다. 경사진 안창의 경사조건은 내/외측 각각 $5^{\circ},\;8^{\circ},\;15^{\circ}$이며, 경사가 없는 안창을 포함해 총 일곱 가지 안창이 실험에 사용되었다. 실험참여자로는 20대 성인 남성 10명이 참여하였다. 실험결과 앞발 누름기에서 MWI와 LWI는 모두 COP를 내측으로 이동시키고 외측 압력을 감소시켰다. 뒤축 접지기에서 MWI는 COP를 내측으로 이동 시키고 내측압력을 증가시키는 반면, LWI는 COP를 외측으로 이동시키고 외측압력을 증가시켰다. 그리고 RVF 분석결과 MWI와 LWI는 모두 앞발 부위 힘의 크기를 감소시켰고, LWI만이 발 뒤축 부위 힘의 크기를 증가시켰다.

  • PDF

A Study on the Operational Method of Urban Arterial With U-Turn (U-Turn을 이용한 간선도로 운영방안)

  • 박용진;손한철
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2000
  • U-turns are allowed widely at the intersections by local police department while the left-turn Phases have been gradually Prohibited. However, any strategies for U-turn movements at signalized intersections are unavailable. Therefore, the Purpose of this study is to Propose the efficient operational method of Urban arterial adopting U-turn strategies. Four alternatives are evaluated they are, 1) U-turn movements are allowed at the adjacent intersection with exclusive U-turn lane while the major or the minor approach is Prohibited, 2) U-turn movements are allowed at the adjacent mid-block Pedestrian crossing with exclusive U-turn lane while the major approach is Prohibited. 3) U-turn movements are allowed at the adjacent mid-block Pedestrian crossing with exclusive U-turn lane while the minor approach is prohibited and 4) Comparative one between alternative 3 and 4. From the results of this study, it concludes that the method of U-turn movements allowed at the adjacent mid-block pedestrian crossing with exclusive U-turn lane is the most effective strategy among those alternatives. The strategies of alternative 1 and 4 are Proposed by the boundary based on the major through and left-turn volumes and the minor left-turn volume.

  • PDF

A Comparative Analysis on Changes of Foot Pressure by Shoe Heel Height during Walking (하이힐 굽 높이에 따른 보행 시 족저압 변화 비교 분석)

  • Park, Jong-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.771-778
    • /
    • 2009
  • We aimed to determine the effect of heel height on foot pressure by comparing and analyzing data on foot pressure in shoes with different heel heights. Qn the basis of a previous study, we selected 3cm and 7cm as the shoe heel heights preferred by female college students. We divided 10 female students into forefoot and hindfoot to measure vertical force, maximum pressure, and average pressure. The average pressure on the forefoot was higher and that on the hindfoot was lower in the case of 7cm high-heeled shoes. The maximum pressure on the forefoot was significantly higher in the case of the 7cm heel height (p<.05). The vertical force, maximum pressure, and average pressure on the hindfoot were also significantly higher in the case of the 7cm heel height (p<.05). The results showed that wearing 7cm high-heeled shoes exerted greater maximum pressure on the forefoot and greater vertical force, maximum pressure, and average pressure on the Hndfoot. This leads to increase in confining pressure caused by high pressure distribution over the forefoot and increase in the pressure on the hindfoot, which may cause deformation of toes and heel pain over a long period. Therefore, female college students who wish to wear high heels are recommended to wear 3cm high-heeled shoes rather than 7cm high-heeled shoes.

Development of Ankle Power Assistive Robot using Pneumatic Muscle (공압근육을 사용한 발목근력보조로봇의 개발)

  • Kim, Chang-Soon;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.771-782
    • /
    • 2017
  • This paper describes the development of a wearable robot to assist ankle power for the elderly. Previously developed wearable robots have generally used motors and gears to assist muscle power during walking. However, the combination of motor and reduction gear is heavy and has limitations on the simultaneous control of stiffness and torque due to the friction of the gear reducer unlike human muscles. Therefore, in this study, Mckibben pneumatic muscle, which is lighter, safer, and more powerful than an electric motor with gear, was used to assist ankle joint. Antagonistic actuation using a pair of pneumatic muscles assisted the power of the soleus muscles and tibialis anterior muscles used for the pitching motion of the ankle joint, and the model parameters of the antagonistic actuator were experimentally derived using a muscle test platform. To recognize the wearer's walking intention, foot load and ankle torque were calculated by measuring the pressure and the center of pressure of the foot using force and linear displacement sensors, and the stiffness and the torque of the pneumatic muscle joint were then controlled by the calculated ankle torque and foot load. Finally, the performance of the developed ankle power assistive robot was experimentally verified by measuring EMG signals during walking experiments on a treadmill.

The effects of strength training on the change of ground reaction force for the children with Down syndrome (근력 훈련이 다운증후군 아동의 지면반력의 변화에 미치는 영향)

  • Lim, Bee-Oh;Han, Dong-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.1-16
    • /
    • 2002
  • The purposes of this study were to investigate the effects of strength training on the change of ground reaction force for the children with trisomy 21 Down syndrome. The subjects of this study were consisted of eight elementary school students with Down syndrome who participated in the strength training. The strength training was administered by six items such as squat, leg curl, leg extension, toe raise, sit-ups, and hyperextension. For strengthening muscle, each group also was treated by walking for 8 weeks, three times a week, 10-15RM, 3sets, which was based on the principle of progressive overload. For inquiring the effect of strength training, the ground reaction force variables were measured in two phases : before-training and 8 week-after training. The gait of each subject was acquisition using 2 AMTI force platforms set at 100 frequency. The results of this study were as follows: The pattern of vertical, antero-posterior and medio-lateral forces, trajectory of net COP and the timing ratio of reaching the each events were shown variously. So, it is not easy to explain these variables clearly. As the result of strength training, these variables were changed. However, the results of within subjects differ greatly, there was no difference statistically.

Development of Train Velocity and Location Tracking Algorithm for a Constant Warning Time System (철도건널목 정시간 제어를 위한 열차속도 및 위치추적방식 개발)

  • Oh, Ju-Taek;Kim, Tae-Kwon;Park, Dong-Joo;Shin, Seong-Hoon
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.4 s.82
    • /
    • pp.17-28
    • /
    • 2005
  • About 91.1% of Railway-Highway Crossings (RHC) in Korea use a Constant Distance Warning System(CDWS), while about 8.9% use a Constant Warning Time System(CWTS). The CDWS does not recognize speed differences of approaching trains and provides only waiting times to vehicles and pedestrians based on the highest speed of approaching trains. Under the CDWS, therefore, low speed trains provide unnecessary waiting times at crossings which often generates complains to vehicle drivers and pedestrians and may cause wrong decisions to pass the crossings. The objective of this research is to improve the safety of the RHC by developing accurate a CWTS. In this research a train speed and location detection system was developed with ultra sonic detectors. Locations of the detectors was decided based on the highest speed and the minimum warning time of Saemaul of 160 km/h. To validate the algorithms of the newly developed systems the lab tests were conducted. The results show that the train detection system provides accurate locations of trains and the maximum error between real speeds of trains and those of the system was 0.07m/s.

Implementation of High Efficiency Generators Applicable to Climbing Sticks (등산스틱에 적용 가능한 고효율 발전기 구현)

  • Gul-Won Bang
    • Journal of Industrial Convergence
    • /
    • v.22 no.7
    • /
    • pp.15-21
    • /
    • 2024
  • A hiking stick is generally one of the walking aids that allow hikers to walk while relying on their own bodies when walking. A rechargeable battery must be built into the hiking stick, which is an auxiliary device, in order to perform various functions. A separate power supply is required to charge the rechargeable battery. This study is about a self-generated power supply and develops a power generation device using a screw with higher power generation efficiency than the existing method. It is differentiated from the method suggested in this study by comparing and analyzing it with the existing power generation method, and identifying problems therewith. The screw-type power generation device generates power when the climbing stick comes into contact with the ground and when it is separated from the ground. The built-in power generation device does not require a separate power supply, and it can be used by attaching the role of a mobile phone auxiliary battery and a lighting lamp, and it has the effect of being able to find it through location tracking by embedding a GPS sensor, etc., and using lighting to keep the user safe in emergency situations such as distress. The existing generator with built-in mountain climbing stick is difficult to charge due to very weak current and low practicality, but the generator developed in this research could achieve high efficiency to obtain a sufficient current, so it is possible to charge a battery and practicality.